ENS31 Automatic Isolation Unit Product Description

Similar documents
ENS26 Automatic Isolation Unit Product Description

Installation and start up instructions. Detection of vector shift. Detection of over- and underfrequency. Generator disconnection on mains failure

Instruction manual SMART 96-2 / WG-2 ph

Technical data. Functional safety related parameters MTTF d. Transfer characteristics. Time delay before availability. Standard conformity

Operating Instruction

Description of CERTO controller Standard

EN 50178, IEC

TEST REPORT DIN V VDE V :2006 Automatic disconnecting device

Power supply CP-E 24/2.5

Rotational speed controller

Brief description of KR 15 controllers

Power supply CP-E 24/20.0

Electrical devices may only be mounted and connected by electrically skilled persons.

Documentation. Measurement and Control. Type: ELT-GP2

MINI-PS AC/24DC/1.3

Operating Instructions

Power supply CP-D 12/2.1

Industrial motor controller for brushed DC motors 12 VDC

MultiMeter-Pocket CAT III 1000 V

VOLTAGE OPTIMIZATION FOR INDUSTRY, TRADE, BUSINESS AND LOCAL NETWORKS

Excitation Systems THYRIPART. Compound-Excitation System for Synchronous Generators. Power Generation

Instruction manual SMART 96-2 / WG-2 LF

Power supply CP-E 24/0.75

EY-EM 527: Remote I/O module, ecolink527

ECM3 EARTH CONTINUITY RELAY

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

! "! # $ % & ' ( ) " * % +, # # -. / ( ! " ! # $ % &

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

Power supply CP-T 24/20.0 Primary switch mode power supply

Instruction Manual TABLE OF CONTENTS 1 PRINCIPLE OF OPERATION Limitations INSTALLATION Mains connection...

Digital Electronic Thermostat With RF

Excitation Systems RG3 - T4. Transistorized Excitation Systems for Synchronous Generators. Power Generation

Orbital GFI Inverter Series

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Power supply CP-E 24/2.5

Power supply CP-D 24/4.2 Primary switch mode power supply

NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC

KNX Powerline PL 110. KNX Association

MINI-PS AC/2X15DC/1

Excitation Systems. Service Generators SIPOL. Transistorized Excitation Systems for Synchronous Generators. Power Generation

Power supply CP-T 48/20.0 Primary switch mode power supply

3B SCIENTIFIC PHYSICS

Power supply CP-D 24/1.3

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

Installation and Operating Instructions. Power IT Power Factor Controller RVC

CM-IWM.11 Insulation monitoring relay

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

Power supply CP-T 48/5.0 Primary switch mode power supply

Power supply CP-T 24/10.0 Primary switch mode power supply

MAVOWATT 4 Multifunction Power Meter

Power supply CP-T 24/40.0 Primary switch mode power supply


ABB i-bus. KNX Weather Station WS/S Product Manual

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

QUINT-PS-24DC/24DC/10

ISOMETER IRDH575. Approvals

TECHNICAL INFORMATION edition 1.02 FOR TRANSISTOR-FOUR-QUADRANT SERVO-AMPLIFIER SERIES MTR /5-15

3B SCIENTIFIC PHYSICS

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Operating Manual * * Differential pressure transmitter. Table of Contents. 1 Safety guidelines. 1.1 General Information

ecotrans Lf 01/02 Transmitter / Switching Device for Conductivity Type B Operating Instructions 02.07/

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Sunways Solar Inverters NT 2500, NT 3000, NT 3700, NT 4200 and NT 5000 AC output: 2.5 to 5.0 kw

Datasheet - PROTECT-IE-02

Documentation. Content. Measurement and Control. Type: ELT-GP1. 1. Installation instructions 2. Data sheets 3. Declarations of conformity

Three-phase monitoring relay

METRATESTER 5+ Tester for DIN VDE /6.15

Industrial motor controller for brushed DC motors 24 VDC

AC CURRENT GENERATOR POC-6000 (current from 0 to 1000 ARMS)

AMU-214 Auxiliary Monitor Unit Operations Manual

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

EPA104/254. User Manual.

Operating Manual Series Load Pins

WD series DIN Rail or Screw Mounted Protective Relays

TECHNICAL DATA SHEET. Safety and function tester GLP1-g. Standard model GLP1-g ELECTRICAL SPECIFICATION

Aggravation with voltage?

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Three-phase monitoring relay CM-PVE

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

R180. AVRs. Installation and maintenance

ELECTRICIAN S THEORY EXAMINATION 17 November 2012 QUESTION AND ANSWER BOOKLET

QUINT-PS/ 3AC/24DC/10

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

Connection Impact Assessment Application

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

Industrial motor controller for brushed DC motors 24 VDC

DPA74/154 AUDAC PROFESSIONAL AUDIO EQUIPMENT. DPA74/154 Quad Channel Class-D Amplifier. User Manual & Installation Guide

1 Safety instructions. 2 Device components. 3 Function. KNX Heating actuator 6gang RMD 230 V. Order-No. :

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

Protection and safety SQZ3 phase and sequence relay

Synchroniser Relay SYN-7

Temperature controller, 4-channel

GTT 25A - 40A - 60A - 90A - 120A POWER SOLID STATE RELAYS WITH ANALOG CONTROL

JUMO ecotrans Lf 03 Microprocessor Transmitter / Switching Device for conductivity or resistivity and temperature

Switching power supplies CP range, Linear power supplies CP-L range. Content

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

E N G I N E E R I N G M A N U A L

Transcription:

ENS31 Automatic Isolation Unit Product Description Issue 09/2005

UfE Umweltfreundliche Energieanlagen GmbH Joachim-Jungius-Straße 9 D 18059 Rostock Tel.: +49 3 81 / 405 97 05 Fax: +49 3 81 / 405 97 03 E-mail: post@ufegmbh.de web: www.ufegmbh.de If you have any queries and need to contact UfE GmbH, always have the serial number close to hand in order to make reference to it. We do not claim the documentation is free of errors and mistakes. Please inform UfE GmbH of any errors found in the documentation. Copyright This Product Description is the copyright of UfE GmbH. This manual is intended for the customers and project planner. It contains instructions and information which must not be copied, distributed or transferred by technical data methods nor used for the purpose of competition, either as an entirety or as extracts, without the necessary authorisation. Contravention could lead to prosecution and obligation to pay damages. All rights reserved, particularly in the case of patent application or other registrations. We reserve the right to make technical modifications without notice. The ENS31 isolation unit and the measuring method are protected by patent. Page 2 of 20 Product Description ENS31 Version: A.02

Table of Contents 1 Purpose of the Product...4 2 System Description...5 2.1 Principles of functioning...5 2.2 LCD displays and LEDs...6 2.3 Connections...7 3 Behaviour of the Isolation Unit...8 3.1 General information...8 3.2 Fluctuations in the mains power supply...8 3.3 Deviation of the mains power frequency...9 3.4 Impedance jumps...9 3.5 Influence of isolation units on each other...10 3.6 Optimised impedance measurement process...10 3.7 Automatic calibration of the impedance measurement.11 3.8 Automatic adaptation of switching thresholds to the mains power conditions...12 3.9 Automatic synchronisation / limitation of signal strength in the case of frequent use of the ENS...13 4 Installation...14 4.1 Mechanical installation...14 4.1.1 Transport and unpacking...14 4.1.2 Conditions for installation...14 4.1.3 Preparing the electrical/meter cabinet...15 4.1.4 Mounting on the top hat rail...15 4.2 Electrical connections...16 4.2.1 Basic configuration...16 4.2.2 Demands of the switching elements...16 4.2.3 Circuitry...17 5 Advantages for the Customer...19 6 Technical Data...20 Version: A.02 Product Description ENS31 Page 3 of 20

Chapter 1 Purpose of the Product 1 Purpose of the Product The automatic, three-phase isolation unit is an automatic switching unit used to connect decentralised power generators safely to the public electricity supply. The ENS31 isolation unit has been conceived as an independent unit for monitoring 3-phase power feeding systems. It prevents uncontrolled island effects following failure or shutdown of the public electricity supply. The ENS31 complies with DIN VDE 0126-1-1 and is approved as a substitute for manual isolation devices up to a 30 kw feeding power. By implementing this automatic isolation unit, it is possible to dispense with a manual isolation unit which must be accessible to the public electricity supply authorities at all times. The feeding systems can be: photovoltaic systems, small hydroelectric power stations, block-type thermal power stations, fuel cells, small wind energy plants. Page 4 of 20 Product Description ENS31 Version: A.02

Chapter 2 System Description 2 System Description 2.1 Principles of functioning The ENS31 automatic isolation unit continually monitors overvoltage and undervoltage frequency deviation impedance jumps in the public electricity supply. In the event of faults in the mains supply, the ENS31 interrupts the feeding of electricity in the mains to prevent island effects. The contact-based disconnection is initiated by externally provided contactors with positively driven NC contacts. These contactors are controlled in two channels by the ENS31 via relays Rel1 and Rel2. Request for the switching status of the external contactors occurs via two acknowledgement inputs. After switching on, Contactor 1 is activated first and Contactor 2 is only enabled after reaching and testing the switching status. The ENS31 cannot be switched on without the acknowledgement inputs being correctly wired. The safety functions are executed in a 3-channel system, whereby each channel measures the mains voltage, mains frequency, mains impedance and the voltage of another channel independently. The channels monitor each other mutually (refer to the error protection in accordance with DIN VDE 0126) to increase error protection. Therefore, recurrent tests can be dispensed with. Further information on the principles of functioning is available on our Internet site at www.ufegmbh.de. Version: A.02 Product Description ENS31 Page 5 of 20

Chapter 2 System Description 2.2 LCD display and LEDs The following indicators are mounted on the front side of the ENS31: X XXXXX A B C D A) LCD The unit and mains power status is shown on a 2-line LC display. Each line can display 16 characters. B to D) LEDs In addition to the LCD, the unit and mains power status are also indicated by three LEDs (red, green, yellow) (B = L1, C = L2, D = L3). The meaning of the indicators is described in the Operating Manual. Page 6 of 20 Product Description ENS31 Version: A.02

Chapter 2 System Description 2.3 Connections The following connections are provided at the top edge of the ENS31: <RELAIS 1 2 3 4 <KONTAKTE 1 2 <NETZ N L1 L2 L3 A B C A B C 4 connection terminals for contactor control, potential-free, 2 connection terminals to connect positively driven auxiliary contacts, 4 connection terminals to connect three phases and the neutral conductor. The connection of the unit is described in the Installation Manual. Version: A.02 Product Description ENS31 Page 7 of 20

Chapter 3 Behaviour of the Isolation Unit 3 Behaviour of the Isolation Unit 3.1 General information The ENS31 monitors the mains power supply and prevents uncontrolled island effects developing in the event of a power failure or the mains being switched off. It reacts to fluctuations in: voltage, frequency, impedance of each individual phase. The default settings can be changed, if necessary. The ENS manufacturer must be informed of these requirements, however, prior to configuration. 3.2 Fluctuations in the mains power supply The threshold values for the mains power supply are set as follows: Fluctuation Threshold value Test interval Overvoltage 300 V Every 20 ms (fast shutdown) Overvoltage 264 V Every 200 ms Undervoltage 130 V Every 20 ms (fast shutdown) Undervoltage 184 V Every 200 ms Disconnection from the mains is also triggered when the 10-minute average value of the mains supply exceeds the setpoint value of 230 V by more than 10% (testing the mains quality). Page 8 of 20 Product Description ENS31 Version: A.02

Chapter 3 Behaviour of the Isolation Unit 3.3 Deviation of the mains power frequency The testing of the frequency of the public electricity supply is completed by all three channels independent of each other via a protective resistor directly in the mains power supply. The threshold values for the mains frequency are set as follows: Fluctuation Threshold value Test interval Overfrequency 50.2 Hz Every 200 ms Underfrequency 47.5 Hz Every 200 ms Channel 1 also measures the phase position between the outer conductors. In the event of a phase difference in excess of 30 degrees, the feeding point is disconnected from the power supply. If the rate of change of the frequency (RoCoF) exceeds 1 Hz/s, disconnection from the supply is also triggered. 3.4 Impedance jumps All three channels measure the mains impedance. The time-dependent change of voltage near the crossover (phase shift), caused by test signals, with various voltage values forms the basis for calculating the mains impedance. All the impedances measured in one second are used to establish an average value. The number of measuring pulses is dependent on the number of ENS connected in the network. Depending on the power characteristics, the triggering threshold for an impedance jump is adapted between 1 ohm and 0.2 ohm. A threshold of 0.5 ohm is set ex works. The automatic adaptation of the switching threshold is described in Section 3.8. Version: A.02 Product Description ENS31 Page 9 of 20

Chapter 3 Behaviour of the Isolation Unit 3.5 Influence of isolation units on each other When isolation units of the type ENS31 are used, they can be implemented in dense proximity in the public electricity supply without it leading to operational problems. Even in the case of long network spurs and a mains supply subject to frequent faults, unproblematic operation can be guaranteed. The ENS31 automatically adapts to these difficult power supply conditions. To achieve this, the following processes are integrated in the ENS31: optimised impedance measurement process, automatic calibration of the measured impedance change, automatic adaptation of switching thresholds to frequent fluctuations and interference levels automatic synchronisation and limitation of signal strength in the case of frequent use of the ENS 3.6 Optimised impedance measurement process The optimised impedance measurement process improves the resolution and interference resistance of the impedance measurement on a large scale. Centralised ripple control signals and frequency converters hardly influence measurements. An island effect is recognised by a sudden increase in the mains power impedance. phase shift measured by the ENS test signal ENS average voltage supply island formation local power supply Page 10 of 20 Product Description ENS31 Version: A.02

Chapter 3 Behaviour of the Isolation Unit 3.7 Automatic calibration of the impedance measurement A precision resistor in the ENS performs an automatic, continuous calibration of the impedance measurements and, at the same time, a continuous, automatic self-test. Manual calibration is no longer necessary. To complete the calibration, the precision resistor is electronically bridged several times per second and the resulting impedance changes used as a reference for the calibration. ENS mains Version: A.02 Product Description ENS31 Page 11 of 20

Chapter 3 Behaviour of the Isolation Unit 3.8 Automatic adaptation of switching thresholds to the mains power conditions A distinction can be made between an overreaction of the ENS and an uncontrolled island effect. In the case of an overreaction by the ENS, the power supply remains available after disconnection of the feeding point from the mains. If an overreaction is detected, the switching threshold for the next shutdown is adapted to a value which is a little above the current threshold value that has lead to a shutdown. Before the switching threshold is adapted to a less sensitive value, the ENS31 switches off briefly in order to check whether the power supply is still available. The threshold is only changed to a less sensitive value when it is recognised that the situation does not concern an uncontrolled island effect. In the case of stable, undisturbed mains supply feeding points, the switching threshold is slowly set to a value (i.e. over several days) which is about double that of the recurrent fluctuations which occurred (safety clearance). As a result of this automatic adaptation to the mains power conditions, safety is considerably increased without limiting the availability of the system. If the interference level repeatedly exceeds the switching threshold, the switching threshold is incremented and the slow adaptation begins again from the start. switching threshold interference level Page 12 of 20 Product Description ENS31 Version: A.02

Chapter 3 Behaviour of the Isolation Unit 3.9 Automatic synchronisation / limitation of signal strength in the case of frequent use of the ENS A team of parallel connected ENS units at the same feeding point generate a joint, stronger test signal through synchronisation. This enables even higher measuring accuracy. Faulty triggering is practically zero and operation is more stable. The parallel connected ENS units generate a decentral test tone. As the number of ENS devices increases, more and more enter a passive operating state. They only generate a few signals themselves and use the jointly generated test signal as a pilot tone which can be measured at the mains power connection point. ENS ENS local power supply ENS Version: A.02 Product Description ENS31 Page 13 of 20

Chapter 4 Installation 4 Installation Danger This chapter only serves for informative purposes. The actual installation must be performed according to the instructions in the Installation Manual enclosed. 4.1 Mechanical installation 4.1.1 Transport and unpacking When transporting the ENS31 isolation unit, pay attention that it is always protected against contact with dirt and damage through impacts and setting down too hard. Remove the ENS31 from the transport packaging and pull off the protective foil, if necessary. After transport and before installation, check that the ENS31 isolation unit is in a perfect condition. 4.1.2 Conditions for installation The ENS31 is intended for installation on a top hat rail in an electrical cabinet or in a meter cabinet. It cannot be installed anywhere. The cabinet must be sufficiently large to house the ENS31, providing the necessary contactors, protect the unit from moisture, dust, dirt and heat. If there is not enough space in the cabinets available, a separate electrical cabinet must be mounted to accommodate the ENS31 and contactors. Attention Never position the electrical cabinet containing the ENS31 above or in the vicinity of a heater. Ensure sufficient ventilation. The ENS31 should be mounted as near as possible to the mains power outlet and as far as possible from the electricity feeding source. These measures reduce the effect of the voltage increase by the current source. Page 14 of 20 Product Description ENS31 Version: A.02

X XXXXX Chapter 4 Installation 4.1.3 Preparing the electrical/meter cabinet Determine the installation position of the ENS31 on the top hat rail. Saw a cut-out in the cabinet cover at the installation position of the ENS31 so that you can see the ENS31 and its indicators (LCD and LEDs) without opening the cabinet. The cut-out must have the following dimensions: 219 mm 74 mm 4.1.4 Mounting on the top hat rail Set the isolation unit with its top housing holder (A) on the top hat rail and turn it downwards against the top hat rail (B). Use a little force to press on the bottom housing section until the housing holder engages in the top hat rail A B Version: A.02 Product Description ENS31 Page 15 of 20

Chapter 4 Installation 4.2 Electrical connections 4.2.1 Basic configuration The switching elements of the automatic isolating device (e.g. contactors) are not enclosed with the unit and must be brought by the installation technician. The technician decides on the switching elements most suitable. Danger The installation technician must ensure that the power generator is only connected to the mains via the two switching elements assigned to the ENS. Risk of accident! The ENS31 must be protected by pre-fuses in the mains feed circuit (min. 6 A, max. 25 A). Observe the circuit diagram. 4.2.2 Demands of the switching elements Two contactors with positively driven auxiliary contacts are required for mains disconnection. The acknowledgement contacts must be connected in the correct sequence (refer to circuit diagram). The contactors must be designed for the nominal output of the current inverter or the system at AC3. The decisive factor for dimensioning is the phase with the highest load. Page 16 of 20 Product Description ENS31 Version: A.02

Chapter 4 Installation 4.2.3 Circuitry Check that the mains power lines and power feed lines are not conducting electricity. Switch the power generator (feeder), ENS31 and contactors as follows: FEEDER 1 3 5 -K10.1 A1 2 4 6 21 -K10.1 A2 22 21 -K10.2 22 1 3 5 A1 2 4 6 A2 -K10.2 N L1 L2 L3 MAINS *** min. 6 A max. 25 A R1R2R3R4 RELAY UfE - ENS31 K1 K2 CONTACTS N L1 L2 L3 MAINS The additional pre-fuse (*) is only necessary if the direct mains power fuse protection exceeds 25 A. Version: A.02 Product Description ENS31 Page 17 of 20

Chapter 4 Installation The terminals on the ENS31 are arranged as follows: relay contacts mains Attention The ground conductor should always bypass the unit. The neutral conductor MUST be connected to the ENS31 otherwise the unit may be damaged. If the ENS31 is switched on and off by means of a system control unit, the L1 connection of the ENS31 can be switched by means of a relay. When switching on via L1, the delay until the contactors are activated can be up to 30 seconds because the ENS31 must test the power feed conditions again. Page 18 of 20 Product Description ENS31 Version: A.02

Chapter 5 Advantages for the Customer 5 Advantages for the Customer Customers have the following advantages: simple connection, easy installation, high degree of safety through monitoring voltage, frequency and impedance jumps, high degree of reliability through automatic, continuous calibration of the impedance measurement, continuous automatic self-test of the isolation unit, replaces the isolation unit provided by the public electricity supplier which must be permanently accessible, avoids inadvertent triggering through automatic adaptation of switching thresholds to the mains supply conditions, minimum energy consumption, minimum heating up, automatic, maintenance-free operation without recurrent tests, automatic synchronisation and limitation of signal strength following frequent use (several ENSs in local mains power supply). Version: A.02 Product Description ENS31 Page 19 of 20

Chapter 6 Technical Data 6 Technical Data Switched power (max.) Own consumption Housing Overall dimensions (W x H x D) Cut-out dimensions (W x H) Ambient conditions Dependent on the contactors assigned 3.5 W Plastic, suitable for assembly on the top hat rail 220 mm x 111 mm x 80 mm 220 mm x 73 mm - 20 C to + 40 C, 10 to 90 % relative humidity, non-condensating Nominal current of power feeder According to max. switching power of the contactors The unit disconnects the mains under the following defined conditions (complying with standard DIN VDE 0126): Overvoltage > 300 V (response time 0.02 s) (fast shutdown) Overvoltage > 264 V (response time 0.2 s) Overvoltage (average) Undervoltage (fast shutdown) 230 V + 10% over 10 minutes < 130 V (response time 0.02 s) Undervoltage < 185 V (response time 0.2 s) Frequency deviation + 0,2 Hz / -2,5 Hz (response time 0.2 s) Impedance jump detection > 0.5 Ohm (response time 0.5 s) Page 20 of 20 Product Description ENS31 Version: A.02