Data sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft

Similar documents
Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft

Data sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations

NETWORK CONNECTIVITY SYSTEMS

Data sheet Patch cord Cat.6 A AWG m yellow

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4

COPPER + LWL RAW CABLES

Data sheet Connection line M12 jack straight - RJ45 plug straight 4-pole, D-coded 2.0 m

OpDAT Universalkabel 1x4 OM4 - biegeunempfindlich, Klasse. Principle diagram

Data sheet OpDAT breakout cable 24x1 OM4 - bend insensitive

Information technology. Generic cabling systems, General requirements

Data sheet OpDAT connection cable 2x1 OS2 - bend insensitive

MULTIMEDIA CABLE H6091ZHB

Data sheet C6 A RJ45 field plug pro

H155A02. Product Description. Product Specifications. Technical Specifications. Application. Bend Radius. CCB-Sub-Crush Resistance.

Category 6 UTP EuroClass C ca Cables

Data sheet E-DAT Industry RJ45 field plug insert Cat.6 Class E A

Category 6 A F/FTP Euroclass C ca Cables

Data sheet E-DAT Industry RJ45 plug black Cat.6 Class E A

Detailed Specifications & Technical Data

Install & Go Cat.8 S/FTP Trunk Cable Assembly Description

Data sheet C5 RJ45 field plug pro 2P PROFINET

Data sheet. M12 field plug X-coded, straight. Illustrations P/N MNF881A EAN Product specification. Page 1/

OPENETICS. P/N E-DAT Industry RJ45 field plug insert Cat.6A. Specialist Manufacturer Voice Data Security.

Data sheet Cable connector class F A

Data sheet C6 A RJ45 field plug pro 360

Data sheet. C5 RJ45 field plug pro 2P 360 PROFINET. Illustrations P/N 130E405042PE EAN Product specification. Page 1/

Install & Go Cat.8 STP Trunk Cable Assembly Description

Data sheet. M12 Jack X-coded IP67, field assembly. Illustrations P/N MMF881A315 EAN Product specification. Page 1/

C400-UMUM-100. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

Data sheet C6 A RJ45 field plug pro 360

Data sheet. E-DAT modul 3 port AP Cat.6A, pure white. Illustrations P/N E EAN Product specification. Page 1/

Data sheet E-DAT modul 2 port AP Cat.6 A, pearl white

Data sheet C6 A RJ45 field plug pro 360

Data sheet C6 A modul K 180 jack - Keystone style

Data sheet E-DAT Industry RJ45 field plug black Cat.6 Class E A

CUSTOM DESIGN COAXIAL CABLES BY SICAB

Detailed Specifications & Technical Data

Install & Go SMARTen (Cat.6A) STP Trunk Cable Assembly General

PRODUCT INFORMATION UNITRONIC BUS PB

C195-SMQM-3M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

Data sheet C6 A modul K 90 jack - keystone style

C400-TMTM-30-X. Jumper Assembly Sample Label. Product Classification. General Specifications. Electrical Specifications

Data sheet. E-DAT modul Cat.6A 8(8) jack, T568B. Illustrations P/N I-B1 EAN Product specification. Page 1/

Detailed Specifications & Technical Data

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

GameChanger Cable. Unshielded Twisted Pair Riser Rated - CMR PRYWB (legacy part no)

Detailed Specifications & Technical Data

AVA5-50FX. Product Classification. Standards And Qualifications. Construction Materials. Dimensions. Electrical Specifications

Detailed Specifications & Technical Data

DB EN valid from: Application SERVO LK SMS FX8PLUS SIGNAL

Cables for data transmission in industrial automation

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s

Addison. Profibus SK Indoor + Outdoor BUS CABLE. Application: Construction:

RG58 Coaxial Cable: 2) Approval:

Cabling systems for LAN Office, LAN Home, LAN Industry, Access Networks, MAN, WAN and SAN. 10 GBit. ELine, MegaLine, FLine, GigaLine

Multimedia Specials DATA CABLES FOR INDUSTRIAL, BUILDING & BROADCAST APPLICATIONS INDUSTRIAL COMMUNICATION BUILDING MANAGEMENT SYSTEMS

C400-NMTM-1M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

C240-NFSM-3M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation.

UNIRAIL D RS485 and BUS cables

Detailed Specifications & Technical Data

Caledonian. Profibus L2 Indoor BUS CABLE. Application: Construction:

CAT 5e UTP Cable: NETSET BOX [305m], indoor

Electrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a.

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified

Selection table for flat & ribbon cables

Contents. Category7 SSTP Solid Indoor Cable - Page 03

Copyright June Nexans


K20 & L120 LSZH Armoured F/FTP Cat6 Cables

ATBTK-MF-4G. Product Classification. Mechanical Specifications. Dimensions. Regulatory Compliance/Certifications.

UTP Cat 5e cable (200 MHz) (PVC sheath)

UC DATA CABLES - CAT 5,6, 7 & 8

Fireproof Cables (Fire Resistant LSOH Sheathed Cables) КИФнг(A)-HF for RS485

Understanding and Inspecting THE DIGITAL BUS. by Jim Sparks

CAT. 5e U/UTP 4x2x24AWG/1 CCA DOUBLE SHEATH


EXCELLENT ELECTRICAL PERFORMANCES

Connection technology for wireless communication systems

ACR (Attenuation to Crosstalk Ratio) ACR-F. Alien Crosstalk. Attenuation (signal attenuation, conductor attenuation)

Servo Cable Selection

Cables for Data Transmission in Industrial Automation. Fieldbus Cables Copper Cables Fibre Optic Cables

A M E R A O W E R I N G Y S T E M S

Field Instrument Cable. Electrical Noise

Cables and connectors for demanding connectivity solutions. LOW LOSS RF COAX CABLES single screen 75 Ω double screen 75 Ω

Part Number: 7953A Cat 6 600V DataTuff, (4 pr) 23 AW G Solid BC, PP/PVC/PVC, Foil Shld, CMR, CMX-Outdoor

INDUSTRIAL DATA LAND. The best solution for the industrial automation.

TPE-INSULATED CABLES TPE-INSULATED CABLES. Products. TPE - Cables HEW-KABEL/CDT

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Coaxial Cables Coax Serie. HF Steckverbinder für Mobilfunk-Anwendungen. in Bulk Rings or on Cable Drums

SAC-3P- 5,0-PUR/M12FR SH

RADIALL DETAIL SPECIFICATION FOR SHF COAXIAL CABLE

Speedflex. Halogen free coaxial cables.

Nexans Industrial Solutions PRODUCT CATALOG

Composite Data, Audio, Video, Security and Control Cables Banana Peel Jacketless Cables Category 5e

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking

50 Ohm COAXES EUROPE. Quality in. 50 Ohm COAXES. WIRELESS Low Loss RG/U MIL-C-17

Ship and Offhsore. Approved cables for ship- and offshoreindustry

Transcription:

Page 1/7 Illustrations Principle diagram Product specification 10 GBit installation cable, duplex installation cable Cat.7A AWG 22 S/FTP with wires shielded in pairs 2x4 pairs (PiMF) pair shield: plastic foil with aluminum coating overall shield: tinned copper braid outer diameter 7.6 / 16.0 mm color of the cable jacket: blue coupling attenuation not less than 85 db applicable standards: EN 50173-1:2011-09; ISO/IEC 11801 Ed.2.2:2011-06; EN 50288-9-1 and IEC 61156-5 cable jacket: LSHF-FR (LSOH-FR) flame-retardant to IEC 60332-1/-2; IEC 60332-3-24; IEC 60754-1/-2 and IEC 64-1/-2 fire behaviour: Class Dca s2 d2 acc. EN 50399 Shipping Units: sold by meter on drum 1640 ft (500 m) on drum *The indication of fire protection classification is currently for your information only and becomes binding only after the assignment of the DoP number.

Page 2/7 General Data Design Installation cables Shielding shielded Transmission technology Copper Cable Type S/FTP Number of twisting elements 2x4 Twisting element Pair Color coding fiber/ wire(s) Color white/orange, orange, white/green, green, white/brown, brown, white/blue, blue blue Cable length (m) 500.00 m Cable length (ft) 1640.42 ft Weight 124.00 kg/km Transmission characteristics Category (ISO) 7A Transmission rate up to 10 GBit IEEE 802.3an Transmission values (nominal) see table Connections/interfaces Termination data, solid wire (min. - max.) Conductor cross section, solid wire AWG 22/1 Conductor diameter, solid wire (bare copper) 0.62 mm Conductor diameter, solid wire (bare copper) 0.024 in. Core diameter (min. - max.) Core diameter (conductor with insulation) Core diameter (conductor with insulation) Cable sheath diameter (min. - max.) Cable sheath diameter Cable sheath diameter Copper index 1.5 mm 0.059 in. 7.8 / 16.4 mm 0.276 in. 61.0 kg/km

Page 3/7 Electrical characteristics Loop resistance max. 116 Ohm/km Transfer impedance 1 MHz max. 5 mohm/m Transfer impedance 10 MHz max. 5 mohm/m Transfer impedance 30 MHz max. 8 mohm/m Characteristic impedance 1- MHz +/-5 Ohm Coupling attenuation min. 85 db Capacitance at 800 Hz Nom 43 nf/km Nominal velocity of propagation ca.76 % Delay skew max. 15 ns/ m Dielectric strength conductor-conductor (primarily) 0 V DC Dielectric strength conductor-conductor (secondary) 0 V DC Dielectric strength conductor-shield 0 V DC Segregation classification D Mechanical characteristics Tensile force 240 N Fire load 0.36 kwh/m Fire load 1300 MJ/km Bending radius without load min. 35 mm Bending radius with load min. 70 mm Materials and material properties Material - Conductor Cu (copper) Material - Conductor Insulation Foam-Skin Polyethylen Material - Cable jacket LSHF-FR (LSOH-FR) Material - Pair shield plastic film Material - Pair shield finish Al (Aluminium) Material - Main shield Cu (copper) braid Material - Main shield finish Sn (tin) Flame retardancy yes

Page 4/7 Environmental conditions Temperature (min. - max.) Temperature - Storage C -20-60 C Temperature - Storage F -4-140 F Temperature - Operating C -20-60 C Temperature - Operating F -4-140 F Temperature - Installation C 0-50 C Temperature - Installation F 32-122 F Approvals RoHS compliant The product meets the following standards Generic cabling systems General requirements ISO/IEC 11801 Ed.2.2: 2011-06 DIN EN 50173-1: 2011-09 Multi-element metallic cables used in analogue and digital communication and control Common test methods for cables under fire conditions Fire behaviour - class DIN EN 50288-9-1 Prüfung der vertikalen Flammenausbreitung an einer Ader, einer isolierten Leitung oder einem Kabel Prüfung der vertikalen Flammenausbreitung an einer kleinen Ader, einer kleinen isolierten Leitung Prüfung der vertikalen Flammenausbreitung von vertikal angeordneten Bündeln von Kabeln & isolierten Leitungen Measurement of smoke density of cables burning IEC 60332-1 Determination of the halogen acid gas content IEC 60754-1 Determination of acidity (by measuring the ph value) and conductivity IEC 60754-2 Klasse Dca s2 d2 nach EN 50399* IEC 60332-2 IEC 60332-3-24 IEC 64

Page 5/7 Classifications ETIM 5.0 EC000830 ETIM 6.0 EC000830 Packing details Type of packaging meter / drum

Page 6/7 Accessories Designation 140302-01-E Jokari dismantle tool

Page 7/7 Transmission values (nominal) Powered by TCPDF (www.tcpdf.org) as per Cat. 7A (at 20 C) FREQ MHz Attenuation (db/m) NEXT db min. PS-NEXT (db) ACR (db/ m) PS-ACR (db/ m) ELFEXT (db/ m) PS-ELFEXT (db/ m) Return loss (db) 1.0 4.0 10.0.0 250.0 500.0 600.0 862.0 0.0 1200.0 1.7 3.4 5.3 16.9 27 40 42 53 56 62 98 96 92 90 85 95 93 89 87 82 101 98 86 76 58 54 39 34 23 98 97 95 83 73 55 51 36 31 20 109 107 105 93 83 70 65 57 54 46 106 104 102 90 80 67 62 54 51 43 26 30 33 33 28 26 25 24 23 21