Datasheet - ZQ N

Similar documents
Datasheet - ZQ Pull-wire emergency stop switches / ZQ 700

Technical data. Contact material: with double break or 2 NC contacts Switching system: A IEC snap action with positive break NC contacts

Datasheet - PROTECT-IE-02

Datasheet - BN 20-RZ. Ordering details. Approval. Global Properties :52:27h. Magnetic reed switch / BN 20.

Safety switches with slotted hole lever

FM series position switches

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

Position switches FM series

Components for safety applications

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

Operating instructions Fail-safe delay timer AZS About this document. Content

Specifications. Safety Ratings. Standards. Safety Classification

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil

LR Position Switches TECHNICAL DATASHEET

LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

Electromechanical pressure and vacuum switches 0

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF

Control stations and enclosures Pendant control stations, for control circuits Double insulated or metal, types XAC-B and XAC-M

Contents. Han Hv ES / Han Hv E Technical characteristics Han Hv ES Technical characteristics Han Hv E Han 3 Hv ES

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

Type CP-S, CP-C & CP-A Switch mode

Technical Data. General specifications. Rated operating distance s n 3 mm

Pendant control stations 6

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Online data sheet UE48-2OS2D2 UE48-2OS SAFETY RELAYS

Control Stations ø 22

Local control stations for Zone 1 and Zone 21. Features. Description

Measuring current transformers of the W, W series

Operator Heads: ø 22mm

Characteristics 5 TeSys k contactors and reversing contactors

Sensors Inductive proximity switches Capacitive proximity switches Optoelectronic proximity switches Magnetic switches

Modular equipment. Presentation, standards. Standard contactors TeSys GC

and signalling units Ø 22 1 Harmony XB7 Monolithic pushbuttons, switches and pilot lights

RXG21BD interface plug-in relay - Zelio RXG - 2 C/O standard - 24V DC - 5A - with LTB

Complete units: Mushroom heads ø 22mm

Technical features table for miniature circuit-breakers SH 200 Series

Online data sheet UE48-3OS2D2 UE48-3OS SAFETY RELAYS

Complete units: Push-buttons ø 22mm

NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC

Signal Beacon - LED Series 6162

02/11/2015

Position switches FR series

NS..S contactor relays - with spring terminals AC operated

Resistance Thermometers Model Series TR7X0, Sheathed Design

Through and Ground Conductor Terminal Blocks 290 Series

Online data sheet UE45-3S13D33 UE45-3S1 SAFETY RELAYS

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts

(1,5 modules per pole)

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module

Han High Temp. Description. Design overview. Han High Temp connectors remain robust and reliable for their entire lifespan!

Power supply CP-D 24/4.2 Primary switch mode power supply

DISCONNECT SWITCHES. UL Listed CSA Certified

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Complete units: Selector switches ø 22mm

Online data sheet UE43-3AR3D2 UE43-3AR SAFETY RELAYS

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Detecting Devices. 8/2 Introduction

Installation / Monitoring Technique

02/11/2015

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

02/11/2015

MICRO SWITCH Key-Operated Safety Interlock Switch GK Series Issue 1. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS DIFFERENTIATION

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

Current / residual current and voltage transformers. Current / residual current and voltage transformers

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Heavy Duty Push-pull / RS422 / speed switch. RoHS 2/22. Magnetic field proof. XXXX e

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

PLATINUM SENSORS FOR MEASURING TEMPERATURES UP TO 400 C 28.11a

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

PSR-SCP- 24DC/ESD/5X1/1X2/300

Subject to changes 11/2003 Page 1/7

Emergency Stops. Shut down all machine functions! Protect machine during breakdown! Meet emergency stop regulations!

Cable Glands, Metal, for shielded EMC Cables CG.EM.*.*.*

Liquid level monitoring relay CM-ENS.2x

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

3 - Protection components Circuit-breakers

5/2 Introduction. Unequipped Distribution Boards 5/4 Modular distribution boards 5/5 Add-on parts

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole

TeSys circuit-breakers Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7

Power supply CP-E 24/2.5

Data sheet. W-Series WDU 4 BL

Data sheet. W-Series WDU 10

02/11/2015

Data sheet. W-Series WDU 2.5

Power supply CP-E 24/0.75

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Data sheet... W-Series WDU 2.5

Data sheet. W-Series WDU 2.5 RT

Separate units: Blocks

Power supply CP-E 24/20.0

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

ORIGINAL INSTRUCTIONS

Power supply CP-E 24/2.5

Electrical height adjustment. ... easy & reliable. Multilift II telescope Multilift II. Synchron

Pendant control stations 6

Operator Heads: ø 22mm

Transcription:

20.07.2016-17:41:15h Datasheet - ZQ 900-13N Pull-wire emergency stop switches / ZQ 900 Preferred typ Metal enclosure one-side operation / wire up to 75 m long Release push button Position indicator Robust design Large wiring compartment Twisting of towing eye not possible External watertight collar wire pull and breakage detection 3 cable entries M 20 x 1.5 (Minor differences between the printed image and the original product may exist!) Ordering details Product type description ZQ 900-13N Article number 101184476 EAN code 4030661332819 ecl@ss 27-37-12-90 Approval Approval TÜV USA/CAN CCC Classification Standards EN ISO 13849-1 B10d Opener (NC) 100.000 Mission time 20 Years notice

Global Properties Product name ZQ 900 Standards IEC/EN 60947-5-1, IEC/EN 60947-5-5, EN ISO 13850 Compliance with the Directives (Y/N) Yes Materials - Material of the housings zinc die-cast - Material of the cover Plastic, thermoplastic - Material of the contacts Silver Housing coating painted Weight 1276 g Emergency-Stop button (Y/N) Yes Mechanical data Design of electrical connection Screw connection Cable section - Min. Cable section 0,75 mm² - Max. Cable section 2.5 mm² Mechanical life > 1.000.000 operations notice All indications about the cable section are including the conductor ferrules. Indicator lamp (Y/N) optional Length of wire max. 75 m Ambient conditions Ambient temperature - Min. environmental temperature 25 C - Max. environmental temperature +70 C Protection class IP65 to IEC/EN 60529 Electrical data Design of control element Switching principle Number of auxiliary contacts Number of safety contacts Rated impulse withstand voltage Uimp Rated insulation voltage Ui Thermal test current Ithe Normally open contact (NO), Opener (NC) Snap switch element 1 piece 3 piece 6 kv 500 V Utilisation category AC-15: 230 V / 4 A, DC-13: 24 V / 1 A Max. fuse rating 6 A 6 A gg D-fuse Dimensions Dimensions of the sensor - Width of sensor 71.5 mm - Height of sensor 220.3 mm up 236.3 mm - Length of sensor 97.2 mm notice

For lengths of over 10 m, intermediate wire supports must be installed every 3 to 5 m. Recommended cable lengths for pull-wire Emergency-Stop switches in relation to the range of ambient temperature. The screwed G24-M20 indicator lamp must be ordered separately, see accessories. As the thimbles are subject to deformation in case of wire pull, the wire should be pulled several times after fitting. After that, the wire must be re-tensioned using the eyebolt or the tensioner. Indication legend A = Position indicator B = Emergency-Stop button C = reset button 1 = Wire rope 2 = Eyebolt 3 = nut 4 = Wire clamp 5 = Tensioning jack 6 = Wire thimble 7 = shackle 8 = rope tensioner Diagram Note Diagram positive break NC contact active no active Normally-open contact Normally-closed contact Ordering suffix The applicable ordering suffix is added at the end of the part number of the safety switch. Order example: ZQ 900-13N-2828...-2828 reduced spring force ("65 N) max. Length of wire 10 m Ordering code ZQ 900-(1)(2) (1) 11 1 Normally open contact (NO) / 1 Opener (NC) 13 1 Normally open contact (NO) / 3 Opener (NC) 22 2 Normally open contact (NO) / 2 Opener (NC) 02 2 Opener (NC) 04 4 Opener (NC)

(2) without N without Emergency-Stop button with Emergency-Stop button Documents Operating instructions and Declaration of conformity (es) 355 kb, 31.03.2014 Code: mrl_zq900_es Operating instructions and Declaration of conformity (en) 358 kb, 26.01.2016 Code: mrl_zq900_en Operating instructions and Declaration of conformity (de) 341 kb, 26.01.2016 Code: mrl_zq900_de Operating instructions and Declaration of conformity (it) 355 kb, 04.02.2014 Code: mrl_zq900_it Operating instructions and Declaration of conformity (fr) 359 kb, 31.03.2014 Code: mrl_zq900_fr Operating instructions and Declaration of conformity (cs) 406 kb, 28.07.2015 Code: mrl_zq900_cs Operating instructions and Declaration of conformity (pt) 360 kb, 25.01.2016 Code: mrl_zq900_pt Operating instructions and Declaration of conformity (nl) 354 kb, 31.03.2014 Code: mrl_zq900_nl Operating instructions and Declaration of conformity (jp) 1 MB, 07.01.2011 Code: mrl_zq900_jp Operating instructions and Declaration of conformity (pl) 396 kb, 31.03.2014 Code: mrl_zq900_pl BG-test certificate (de, en) 295 kb, 26.11.2007 Code: z_zq9p01 Brochure (it) 391 kb, 09.06.2006 Code: b_900p05 Brochure (fr) 415 kb, 26.07.2007 Code: b_900p03 Brochure (pt) 391 kb, 12.09.2006 Code: b_900p10 Brochure (es) 391 kb, 09.06.2006 Code: b_900p09 Brochure (en) 389 kb, 09.06.2006 Code: b_900p02 Brochure (de) 390 kb, 09.06.2006

Code: b_900p01 CCC certification (en) 881 kb, 27.04.2016 Code: q_zq9p02 CCC certification (en) 881 kb, 27.04.2016 Code: q_zq9p02 CCC certification (cn) 869 kb, 27.04.2016 Code: q_zq9p03 CCC certification (cn) 869 kb, 27.04.2016 Code: q_zq9p03 EAC certification (ru) 844 kb, 05.10.2015 Code: q_6037p17_ru Images Dimensional drawing (basic component) Characteristic curve Operating principle

Operating principle Operating principle System components Accessories 101162986 - Eyebolt BM 8 x 70 101084928 - Eyebolt BM 10 x 40 101203477 - Wire clamp 3 mm NIRO 101203478 - Wire clamp 5 mm NIRO 101190917 - Duplex wire clamp 3 mm NIRO for Wire rope Ø 3 mm

101196043 - Egg-shaped wire clamp GR 3 for Wire rope Ø 3 mm 101203472 - WIRE THIMBLE 3 mm NIRO for Wire rope Ø 3 mm to DIN 6899 101203476 - WIRE THIMBLE 5 mm NIRO for Wire rope Ø 5 mm to DIN 6899 101192433 - PULLEY for Wire rope Ø 3 mm To guide the wire rope where the path is not a straight line 101087930 - TENSIONING JACK M6 For exact adjustment of the tension of the wire rope to DIN 1480 101186696 - TENSION SPRING RZ-2041 To maintain the reaction force 101186490 - SHACKLE NIRO Shackle for fixing the wire rope to the eyebolt 101078670 - WIRE ROPE 5 mm Ø 5 mm total Steel core Ø 3 mm Quantity: Meter

103003628 - WIRE UNIT COMPLETE 5 m 103003629 - WIRE UNIT COMPLETE 10 m 103003865 - WIRE UNIT COMPLETE 15 m 103003866 - WIRE UNIT COMPLETE 20 m 103003630 - WIRE UNIT COMPLETE 30 m 103003867 - WIRE UNIT COMPLETE 40 m 103003631 - WIRE UNIT COMPLETE 50 m 101186704 - rope tensioner S 900 Smooth adjustment Only one tool Antiskid Time-saving

Ergonomic No risk of injury 101150877 - Indicator lamp G24-M20 red LED and green LED To be screwed in cable entries M 20 x 1.5 white lens (clear) 101186263 - Indicator lamp G24-M20 Orange amber LED, white lens (clear) To be screwed in cable entries M 20 x 1.5 101193805 - MP ZQ/TQ900-441/75 Mounting plate set for ZQ 900 / TQ 900 103006011 - ACC-CGLD-M20-MS cable gland M20 Metal film 103006009 - ACC-BPL-M20-MS Locking screw M20 Metal film K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am 20.07.2016-17:41:17h Kasbase 3.2.4.F.64I