10Gb/s SFP+ Optical Transceiver Module AO+-CXXXX-R80. 10GBASE-ZR/ZW, up to 80km SM Fiber Link

Similar documents
10Gb/s SFP+ Optical Transceiver Module 10GBASE-SR/SW

SFP-10G-M 10G Ethernet SFP+ Transceiver

10Gb/s CWDM SFP+ Optical Transceiver TR-LXxxL-N00

10Gb/s SFP+ BX LC DDMI Optical module Tx:1330nm/Rx:1270nm 10km transmission distance

10Gb/s SFP+ BiDi Optical Transceiver. TR-DXxxI-V00, 20Km SMF Application. 10GBASE-LR/LW Bi-directional, LC connector

This 1310 nm DFB 10Gigabit SFP+ transceiver is designed to transmit and receive optical data over single mode optical fiber for link length 10km.

T A S A 1 E B 1 F A Q

T A S A 1 N A

QFX-SFP-10GE-SR (10G BASE-SR SFP+) Datasheet

T A S A 1 E H

T A S - A 5 J H 1 - P A Q

EMPOWERFIBER 10Gbps 300m SFP+ Optical Transceiver EPP SRC

Specification. Small Form Factor Pluggable 28 Duplex / Single TX / Single RX LC Receptacle SFP28. Optical Transceivers 24 Gigabit SDI.

T A S A 1 N H 1 P 1 1

SO-SFP28-LR. SFP28, 25GBASE-LR, 1310nm, SM, DDM, 10km OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION DATASHEET 4.1

T A S A 5 N B 1 F A H

T A S - A 5 U B 1 - F 1 1

10Gb/s DWDM XFP Optical Transceiver AOX-DXX-R40

SO-QSFP28-4xSFP28-AOCxM

Femrice 70KM CWDM SFP+ Optical Transceiver FS-CWDM-F70

1550nm SFP+ Optical Transceiver, 40km

80KM DWDM SFP+ Optical Transceiver

10Gb/s XFP Tunable Optical Transceiver XFP-1080-DTZR. Preliminary Datasheet

LEG. 10Gbps SFP+ Transceiver

70~80km CWDM XFP Optical Transceiver

Features: Applications: Description:

10G SFP+ ER 1550nm 40km Optical Transceiver GPP ERC

10Gbps 40km Range SFP+ CWDM Optical Transceiver

APSB53123xxL20. Product Features. Applications. General. 1.25Gb/s BiDi SFP Transceiver

SHPP-10G-DT Gb/s Tunable SFP+ Transceiver Hot Pluggable, Duplex LC, +3.3V, 50GHz ITU Grid, Single mode, 80km, 0~70 C

10Gbps 1550nm 80KM SFP+ Optical Transceiver

GIGALIGHT 80km 1550nm SFP+ Optical Transceiver GPP ZRC

10Gbps 1550nm 80KM SFP+ Optical Transceiver 10Gbps 850nm 300M SFP+ Optical Transceiver

XBR C. 8Gbs SFP+ Transceiver

DATASHEET 4.1. SFP+, 10GBase-ZR, Multirate Gbps, C Tunable, DWDM, C-Band, 50GHz, 22dB, 80km, ind. temp.

SFP-1020-WA/B 10Gbps SFP+ Bi-Directional Transceiver, 20km Reach 1270/1330nm TX / 1330/1270 nm RX

XFP DWDM 10G 80Km ZR SLXFD-10XX-ZR

SFP-1040-Cxx 40Km SFP+ CWDM Optical Transceiver

SFP-1080-Cxx 80Km SFP+ CWDM Optical Transceiver

DATASHEET 4.3. SFP+, 10GBase-LR, 1310nm, SM, DDM, 70km, RX sensitivity -22 dbm, Ind.temp.

FSPC-xx12-40D. 1.25G SFP CWDM 1470nm~1610nm 40km Optical Transceiver

DWDM SFP+ Series DWDM EML

10Gb/s 850nm Multimode SFP+ Transceiver

EMPOWERFIBER 70km~80km 1550nm SFP+ Optical Transceiver EPP ZRC

10Gb/s DWDM Single-mode SFP+ Transceiver

10G CWDM SFP+ 40km ER Transceiver Hot Pluggable, Duplex LC, +3.3V, 1470~1610nm CWDM EML, DDMI PSFP10-1C41SF-XX

SFP-10G-SR-LEG. 10Gbs SFP+ Transceiver

SFP-10G-LR-TX. Product Features. Applications. Product Selection. Cisco Compatible 10GBase-LR SFP TurboX

GLC-GE-100FX-LEG. 155Mbps SFP Transceiver

Features Gigabit Ethernet

GLC-LH-SM-TX. Product Features. Applications. General. Cisco Compatible 1000BASE-LX/LH SFP TurboX

GLC-SX-MM-LEG. 1.25Gbps SFP Transceiver

JD061A-C. 1.25Gbps SFP Transceiver

1550nm 40km SFP+ Transceiver

Specifications. (Tc=-5 to 70 and Vcc= 3.14 to 3.46V) Nominal Wavelength λ nm Side Mode Suppression Ratio. Receiver

10Gb/s SFP+, Hot Pluggable, Duplex LC, +3.3V, 1310nm, Multi Mode, 220m FP-LD Optical Transceiver PSFP MF

GLC-LH-SMD-AO. 1.25Gbps SFP Transceiver

GBP-XXXX192-L2C 10Gbps SFP+ Bi-Directional Transceiver, 20km Reach 1270/1330nm TX / 1330/1270 nm RX

TPP3XGDS0x000E2G 850nm SFP+ Transceiver

10GBase LR-Lite SFP+ Optical Transceivers (I-Temp)

SFP+ Series SFP-10G-SR

1550nm 40km SFP+ Transceivers

Specifications. (Tc=-5 to 70 and Vcc= 3.14 to 3.46V)

10Gbps XFP Optical Transceiver

Part Number Ordering Information

GLC-LH-SM-LEG-5PK. 1.25Gbps SFP Transceiver

(Tc=-5 to 70 and Vcc= 3.14 to 3.46V)

10G SFP+ CWDM 20km Transceiver Hot Pluggable, Duplex LC, +3.3V, 1270~1350nm CWDM DFB, DDMI PSFP-2C41SF-XX

Applications: Description:

LEG. 10Gbs SFP+ Transceiver

SFP-ZX-SM Gbps SFP Optical Transceiver, 80km Reach

Part Number Operating temperature DDMI. APSCxx123CXL80 Commercial No. APSCxx123CDL80 Commercial Yes. APSCxx123IXL80 Industrial No

Applications: DWDM Networks SONET OC-192/SDH STM-64 10GBASE-ER/EW Ethernet 40km 10G Fiber Channel. Description:

EMPOWERFIBER 80km DWDM XFP Optical Transceiver EXD-XX192-08C

Data Sheet. 10Gb DWDM XFP Transceiver, 80km Hot Pluggable, Duplex LC, DWDM EML-LD, APD Receiver SM, PXFP-0D71SF-XX Issue: November 2010

SFP-1000BASE-LX-LEG. 1.25Gbps SFP Transceiver

Applications: Description:

10Gb/s CWDM SFP+ 20Km RT-P10LCM-C00-xx. Optical Transceiver

PRODUCT FEATURES APPLICATIONS. Pin Assignment: 1 Gigabit Long-Wavelength SFP Transceiver SFP-SX-MM

XTBxxA-20LY 10 Gbps SFP+ Bi-Directional Transceiver, 20 km Reach

Part Number Operating temperature DDMI. APS31123CXL2 Commercial No. APS31123CDL2 Commercial Yes. APS31123IXL2 Industrial No

DWDM SFP 4.25Gb/s Transceiver 30Km Hot Pluggable, Duplex LC, 3.3v C Band 100-GHz DWDM DFB-LD PDSFP-96-1XX12-22F

10GBASE-LR/LW SFP MSA SFF-8472 SFF-8431 SFF-8432 Compliant

10Gb/s 80km 1550nm APD SFP+ Optical Transceiver GTR2SP1Z

Part Number Wavelength Operating Case temperature. APCSP23B33CDL10 Tx-1270 / Rx-1330 Commercial. APCSP32B33CDL10 Tx-1330 / Rx-1270 Commercial

10Gb/s 300m SFP+ Transceiver

PRODUCT SPECIFICATION

AA C 1000BASE-CWDM, Small Form-factor Pluggable (SFP), 1.25Gb/s data rate, 1590nm wavelength, 70Km reach

XFP DWDM 10G 40Km ER SLXFD-10XX-ER

6Gbps SFP+ Optical Transceiver,10 Km (OP3B10D ) Hot Pluggable, Duplex LC, +3.3V 1310nm DFB-LD. Features

Part Number Transmitter Output Power Receiver Sensitivity Reach Temp DDM RoHS

1.25Gb/s SFP Transceiver P/N: MO-C-S31123CDL20. Product Features. Applications. General. Regulatory Compliance. Up to 1.

10Gb/s 10Km CDR SFP+ 1310nm Transceivers

40G-QSFP-ER4-LEG. 40Gbase QSFP+ Transceiver

DATA SHEET: Transceivers

XTS31U-10Lx. 10 G Ethernet 10 km SFP+ Transceiver 10GBASE-LR/10GBASE-LW. XTS31U-10Lx 10 G 10 km SFP+ Transceiver. Applications.

CWDM SFP 1.25G 40KM LC Duplex

DWDM SFP Series. Laser

Part Number Operating Case temperature DDMI. ESD to the Electrical PINs: compatible with MIL-STD-883 Method 3015

PT0-M3-4D33Q-I. Product Overview. Absolute Maximum Ratings.

Transcription:

10Gb/s SFP+ Optical Transceiver Module AO+-CXXXX-R80 10GBASE-ZR/ZW, up to 80km SM Fiber Link Features 10Gb/s serial optical interface compliant to 802.3ae 10GBASE-ZR/ZW Electrical interface compliant to SFF-8431 specifications 2-wire interface for management specifications compliant with SFF 8472 agreement Operating case temperature: 0 to 70 C All-metal housing for superior EMI performance Low power consumption, less than1.8 w Advanced firmware allow customer system encryption information to be stored in transceiver Cost effective SFP+ solution, enables higher port densities and greater bandwidth Applications 10GBASE-ZR/ZW 10GBASE-ZRZ/W + FEC 10G Storage system RoHS compliant Figure1: Application in System July, 2011 1 Rev1.7

1. GENERAL DESCRIPTION This cooled EML laser based 10Gigabit SFP+ transceiver is designed to transmit and receive optical data over single mode optical fiber for link length up to 70km. The SFP+ ZR CWDM module electrical interface is compliant to SFI electrical specifications. The transmitter input and receiver output impedance is 100 Ohms differential. Data lines are internally AC coupled. The module provides differential termination and reduce differential to common mode conversion for quality signal termination and low EMI. SFI typically operates over 200 mm of improved FR4 material or up to about 150mm of standard FR4 with one connector. The transmitter converts 10Gbit/s serial PECL or CML electrical data into serial optical data compliant with the 10GBASE-ZR standard. An open collector compatible Transmit Disable (Tx_Dis) is provided. Logic 1 or no connection on this pin will disable the laser from transmitting. Logic 0 on this pin provides normal operation. The transmitter has an internal automatic power control loop (APC) to ensure constant optical power output across supply voltage and temperature variations. An open collector compatible Transmit Fault (Tx_Fault) is provided. TX_Fault is module output contact that when high, indicates that the module transmitter has detected a fault condition related to laser operation or safety. The TX_Fault output contact is an open drain/collector and shall be pulled up to the Vcc_Host in the host with a resistor in the range 4.7-10 kω. TX_Disable is a module input contact. When TX_Disable is asserted high or left open, the SFP+ module transmitter output shall be turned off. This contact shall be pulled up to VccT with a 4.7 kω to 10 kω resistor The receiver converts 10Gbit/s serial optical data into serial PECL/CML electrical data. An open collector compatible LOS is provided. Rx_LOS high indicates an optical signal level below specified spec. The Rx_LOS contact is an open drain/collector output and shall be pulled up to Vcc_Host in the host with a resistor 4.7-10 kω, or with an active termination. Power supply filtering is recommended for both the transmitter and receiver. The Rx_LOS signal is intended as a preliminary indication to the system in which the SFP+ is installed that the received signal strength is below the specified range. Such an indication typically points to non-installed cables, broken cables, or a July, 2011 2 Rev1.7

disabled, failing or a powered off transmitter at the far end of the cable. 2. PROPOSED APPLICATION SCHEMATICS July, 2011 3 Rev1.7

3. PIN DEFINITION The SFP+ modules are hot-pluggable. Hot pluggable refers to plugging in or unplugging a module while the host board is powered. The SFP+ host connector is a 0.8 mm pitch 20 position right angle improved connector specified by SFF-8083, or stacked connector with equivalent with equivalent electrical performance. Host PCB contact assignment is shown in Figure 3 and contact definitions are given in Table 1. SFP+ module contacts mates with the host in the order of ground, power, followed by signal as illustrated by Figure 4 and the contact sequence order listed in Table 1. Figure 3: Module Interface to Host Figure 4: Module Contact Assignment July, 2011 4 Rev1.7

PIN Logic Symbol Name / Description Note 1 VeeT Module Transmitter Ground 1 2 LVTTL-O TX_Fault Module Transmitter Fault 3 LVTTL-I TX_Dis Transmitter Disable; Turns off transmitter laser output 4 LVTTL-I SCL 2-Wire Serial Interface Clock 2 5 LVTTL-I/O SDA 2-Wire Serial Interface Data Line 2 6 MOD_DEF0 Module Definition, Grounded in the module 7 LVTTL-I RS0 Receiver Rate Select 8 LVTTL-O RX_LOS Receiver Loss of Signal Indication Active High 9 LVTTL-I RS1 Transmitter Rate Select 10 VeeR Module Receiver Ground 1 11 VeeR Module Receiver Ground 1 12 CML-O RD- Receiver Inverted Data Output 13 CML-O RD+ Receiver Data Output 14 VeeR Module Receiver Ground 1 15 VccR Module Receiver 3.3 V Supply 16 VccT Module Receiver 3.3 V Supply 17 VeeT Module Transmitter Ground 1 18 CML-I TD- Transmitter Inverted Data Input 19 CML-I TD+ Receiver Non-Inverted Data Output 20 VeeT Module Transmitter Ground 1 Table 1: SFP+ Module PIN Definition Note: 1. Module ground pins GND are isolated from the module case. 2. Shall be pulled up with 4.7K-10Kohms to a voltage between 3.15V and 3.45V on the host board. July, 2011 5 Rev1.7

4. TRANSCEIVER BLOCK DIAGRAM Figure 5: Module Block Diagram 5. ABSOLUTE MAXIMUM RATING These values represent the damage threshold of the module. Stress in excess of any of the individual Absolute Maximum Ratings can cause immediate catastrophic damage to the module even if all other parameters are within Recommended Operating Conditions. Parameters Symbol Min. Max. Unit Power Supply Voltage V CC 0 3.6 V Storage Temperature Tc -40 85 C Operating Case Tc 0 70 C Temperature Relative Humidity RH 5 95 % RX Input Average Power Pmax - 0 dbm Table 2: Absolute Maximum Rating July, 2011 6 Rev1.7

6. RECOMMENDED OPERATING ENVIRONMENT Recommended Operating Environment specifies parameters for which the electrical and optical characteristics hold unless otherwise noted. Parameters Symbol Min. Typical Max Unit Power Supply Voltage V CC 3.135 3.3 3.465 V Power Supply Current Icc - 400 600 ma Operating Case Temperature T C 0 25 70 C Table 3: Recommended Operating Environment 7. OPTICAL CHARACTERISTICS The following optical characteristics are defined over the Recommended Operating Environment unless otherwise specified. Transmitter Optical Interface Parameter Symbol Min Typical Max Unit Note Operating Data Rate - 9.95 11.30 Gb/s 1 Output Center Wavelength λ Per ordering info nm SMSR SMSR 35 - db Average Output Power Po 0 +4 dbm 2 Disabled Power Poff - -30 dbm 2 Extinction Ratio ER 9.0 10 - db 2 Eye Mask 1(SONET/SDH) GR-253-CORE/ITU-T G.691 2 Eye Mask 2 (10G Ethernet) IEEE802.3ae 3 Center wavelength stability λd -6.5 6.5 nm Spectral Width (-20dB FW20 0.25 nm July, 2011 7 Rev1.7

from Peak) Relative Intensity Noise RIN - -130 db/hz Dispersion Penalty DP 2 db Receiver Optical Interface Parameter Symbol Min Typical Max Unit Note Operating Data Rate 9.95 11.30 Gb/s 1 Input Center Wavelength lrc 1250 1620 nm Overload Rovl -7.0 - dbm Minimum Sensitivity Pmin - - -24.0 dbm 2 LOS Assert LOSA -35 dbm LOS Deassert LOSD -28 dbm LOS Hysteresis LOSH 0.5 db Optical Return Loss ORL 27 - db Jitter Tolerance JTL GR-253-CORE/ITU-T G.783 Table 4: Optical Characteristics Notes: 1. Average optical power shall be measured using the methods specified in TIA/EIA- 455-95. 2. Receiver sensitivity is informative. Stressed receiver sensitivity shall be measured with conformance test signal for BER =1x 10-12. 3. Path penalty is intended as the power penalty of the interface between back-toback and the maximum applied dispersion. July, 2011 8 Rev1.7

8. DIGITAL DIAGNOSTIC FUNCTIONS The following digital diagnostic characteristics are defined over the Recommended Operating Environment unless otherwise specified. It is compliant to SFF8472 Rev10.2 with internal calibration mode. For external calibration mode please contact our sales stuff. Parameter Symbol Min. Max Unit Notes Over Temperature monitor DMI_Temp -3.0 3.0 degc operating absolute error temp Laser power monitor DMI_TX -3.0 3.0 db absolute error RX power monitor absolute error DMI_RX -3 3 db -7dBm to -24dBm Supply voltage monitor absolute error DMI_VCC -0.1 0.1 V Bias current monitor DMI_Ibias -10% 10% ma Full operating range Table 5: Digital diagnostic specification table July, 2011 9 Rev1.7

9. ELECTRICAL CHARACTERISTICS The following electrical characteristics are defined over the Recommended Operating Environment unless otherwise specified. Parameter Symbol Min. Typical Max Unit Notes Data Rate 9.95 10.3125 11.3 Gbps NRZ Power Consumption - 1300 1800 mw Transmitter Single Ended Output Voltage Tolerance -0.3-4 V Common mode voltage tolerance 15 - - mv Tx Input Diff Voltage VI 180 700 mv Tx Fault VoL -0.3 0.4 V At 0.7mA Data Dependent Input Jitter DDJ 0.1 UI Data Input Total Jitter TJ 0.28 UI Receiver Single Ended Output Voltage Tolerance -0.3-4 V Rx Output Diff Voltage Vo 300 850 mv Rx Output Rise and 20% to Tr/Tf 30 ps Fall Time 80% Total Jitter TJ 0.7 UI Deterministic Jitter DJ 0.42 UI Table 6: Electrical Characteristics July, 2011 10 Rev1.7

10. CONTROL AND STATUS I/O TIMING CHARACTERISTICS Timing characteristics of control and status I/O are included in Table 8, which is also defined in SFF-8431. Parameter Symbol Min Max Unit Condition TX_Disable assert time t_off 10 Us Timing from rising edge of TX_Disable to when the optical output falls below 10% of nominal TX_Disable negate time t_on 1 ms Timing from falling edge of TX_Disable to when the modulated optical output rises above 90% of nominal Time to initialize Including reset of t_init 300 ms From power on or negation of TX Fault using TX Disable TX_Fault TX_fault assert time TX_fault 100 us From occurrence of fault to assertion of TX_fault TX Disable to reset t_reset 10 us Time TX_Disable must be held high to reset TX_fault Los assert time t_loss_o n 100 us Time from LOS state to Rx_Los assert Los Deassert Time t_loss_o ff 100 us Time from non_ LOS state to Rx_Los deassert Rate-Select Change Time t_ratese l 10 us Time from rising or falling edge of Rate Select input until receiver bandwidth is in conformance with appropriate specification July, 2011 11 Rev1.7

Serial ID Clock Rate f_serial_ clock 100 khz Table 7: Timing Characteristics 11. MECHANICAL Comply with SFF-8432 rev. 5.0, the improved Pluggable form factor specification. Figure 6: Module Mechanical Size 12. ESD This transceiver is specified as ESD threshold 1kV for SFI pins and 2kV for all others electrical input pins, tested per MIL-STD-883, Method 3015.4 /JESD22-A114-A (HBM). However, normal ESD precautions are still required during the handling of this module. This transceiver is shipped in ESD protective packaging. It should be removed from the packaging and handled only in an ESD protected environment. July, 2011 12 Rev1.7

13. LASER SAFTY This is a Class 1 Laser Product according to IEC 60825-1:2007. This product complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated (June 24, 2007) 13. Ordering Information Part Number Product Description AO+-CXXXX-R80 10Gbps,CWDM SFP+ XXXXnm 80km, 0 C to 70 C ITU grid wavelengths and frequencies are represented by the CWDM channel code xx field in the part number: Channel Code (xx) Wavelength (nm) Frequency (THz) 47 1471 203.80 49 1491 201.07 51 1511 198.41 53 1531 195.82 55 1551 193.29 57 1571 190.83 59 1591 188.43 61 1611 180.49 AscentOptics reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Edition: Apr. 2009 Published by Ascent Optics Co.,Ltd. Copyright Ascent Optics All Rights Reserved. E-mail: sales@ascentoptics.com Web : http://www.ascentoptics.com July, 2011 13 Rev1.7