Radiocontrol F. Floor Heating Controller Radio control system for floor heating

Similar documents
Thermostat P. Thermostats Electronic room thermostat with clock for thermal actuators

PRODUCT CATALOGUE TEMPERATURE CONTROL Grässlin products for individual control of temperature

INSTAT 868 Radio Frequency Single-Room Controls

Control solutions Biofloor

SERVICE-MANUAL ROOM TEMPERATURE CONTROLLER NEA 230V / 24V. Construction Automotive Industry

TA-Slider 160. Actuators Digitally confi gurable proportional push actuator 160/200 N

LK Wireless Room Control Cq

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

NRT 105: Electronic fan-coil controller, equiflex

AHC-XP. Dewpoint-guided Power Controller for Glass and Handrail Heaters. Front view. Characteristics

Radio controllers. Innovation combined with skill and tradition. Intelligent solutions. for all living spaces. Radio-controlled regulation

43.019/1. NRT 300: Electronic controller for air-conditioning (heating/cooling) Sauter Components

OPERATING INSTRUCTIONS ARE ON PAGE 5. SECTION 2 Technical Data Transmitter Unit. RVHT 2 MULTI-FIT Programmable R/F Thermostat-Pair SECTION 1

WAGO Application: Plastic Technology Center (SKZ) in Würzburg, Germany

Communicative heating controller

NRT 300: Electronic air-conditioning controller, heating/cooling, equiflex

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes

Self-learning Room Temperature Controller Receiver

Wireless Room Thermostat Installation and Operation Y6630D1007

ORDERING CODE Z-WAVE FREQUENCY COUNTRY/REGION

Wireless multizone receiver RDE-MZ6

200 RTH OFF ON IN OUT ALARM RESET

EUROSTER 2026/2026TX

JUMO ecotrans Lf 03 Microprocessor Transmitter / Switching Device for conductivity or resistivity and temperature

Room Temperature Controllers. for heating and cooling systems

RAMSES 784 HF Set 1. Bedienungsanleitung Uhrenthermostat 1. Operating Instructions Clockthermostat 14. Mode d emploi Thermostat à horloge 26

CM927 WIRELESS PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

JUMO Wtrans Receiver with Wireless Data Transmission

Wireless Control Systems

Technical data. Functional safety related parameters MTTF d. Transfer characteristics. Time delay before availability. Standard conformity

Ultrasonic level transmitter, non-contact

Universal Controller

Room Temperature Controllers. for heating and cooling systems

EIB/KNX Switch Actuators. User manual

JUMO Wtrans probe RTD temperature probe with wireless transmission of the measured values

R7426A. MicroniK 200 TEMPERATURE CONTROLLER WITH AND WITHOUT REAL-TIME CLOCK

02/11/2015

02/11/2015

TLC3-BCR-U Series Thermostat

Fan Coil Actuator FCA 2

Overview of types. Technical data

* _Ver.1* GP8 Radio CPL Radio DRIVER Energy manager

Digital Electronic Thermostat With RF

SRC-110 Series Zone Controllers with Modbus RTU

WIRELESS CONTROL UNIT FOR CONTROL OF ELECTRIC HEATING DEVICES (WITHIN ONE ROOM)

B850 Boiler House Energy Monitor

Instruction. INFOCAL 8 Energy calculator. 1.0 Table of contents. 2.0 Safety notes and product information

Sauter Components

Infocal 9 Energy calculator

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

Electronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03

Electric thrust actuator. Electric thrust actuator ARI-PREMIO -Plus 2G. 2,2-5 kn. Electric thrust actuator. ARI-PREMIO -Plus 2G kn.

Preset counters, electronic

Smart Power Relay E I...

Digital indicator for panel mounting With multi-function input Model DI25

Room Temperature Controllers. for heating and cooling systems

Proud Partners with MOBATime

CS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL

Room Temperature Controllers. for heating and cooling systems

Interface EKC 366 REFRIGERATION AND AIR CONDITIONING. Manual

Digital flowmeter for continuous flow measurement

DIN Rail Time & Twilight Switches

theben Fan Coil Actuator FCA 1 Fan Coil Actuator FCA 1 FCA Version: Jan-08 (Subject to change) Page 1 of 77

Operating Instructions

UNICONT. PMG-400 Universal controller and display unit USER'S AND PROGRAMMING MANUAL 1. pmg4111a0600p_01 1 / 24. ST edition

Pulse Scaler for DIN Rail Attachment

STR-LCF. Security Advice Caution. Notes on Disposal. Electronic Fan Coil Thermostat (Flush mounting) Datasheet. Application

DeltaSol MX. Certifi ed for the North American market! CONTROL TECHNOLOGY. incl.

FX10 Standard Programmable Electronic controller for HVAC and refrigeration applications. Features and Benefits

User Instructions For TopTronic RS-10

Wireless valve actuator for bidirectional EnOcean communication. The SAB05 combines with message server and enocean transmitter.

Multifunctional counter tico 772/773/774

Microprocessor Based Multistage Temperature Controller & Two Channel 365 Day Time Switch. Made in Australia 100% Australian Owned Company

Universal process controller econtrol

Room Temperature Controller

02/11/2015

Instruction. SONOMETER 1100 Ultrasonic compact energy meter. 1.0 Table of contents. 2.0 Safety notes and product information

Digimax 210. Programmable Thermostat. User Guide

Universal process controller econtrol

Sunways Solar Inverters NT 2500, NT 3000, NT 3700, NT 4200 and NT 5000 AC output: 2.5 to 5.0 kw

QFM21... Duct sensors. Symaro. for relative humidity and temperature

100 h; (min. 70 h at 40 C); 200 days (typ.) with optional battery module Memory Number of memory modules (optional)

Intelligent Compact Controller

The CM Range. Clearly different

Remote Switching Unit nivotester FTL 320

INFOCAL 8 Energy calculator

B850 Boiler House Energy Monitor

Room Temperature Controllers. for heating and cooling systems

Digital flowmeter for continuous flow measurement

Installation Guide. ECL Comfort 310, application A Table of Contents

Technical data. General specifications V DC No-load supply current I 0. typ. 50 ma Power consumption P 0

Universal process controller econtrol

Level Transmitter / Controller / Indicator. 3-in-1 package that is simple to install and use. With expanded ranges and improved chemical resistance.

Room air quality sensors

LST400 Ultrasonic level / open channel flow transmitter

RCMS460 and RCMS490 Series

Power amplifier for thermic valve actuators

Relay (R1) 003. Balancing Valve. Slab Pump (P1) Max. 4 pipe diameters apart. Injection Pump (P2) 150 No 24V only. Power. Off.

DENISON HYDRAULICS Proportional Pressure Control Valves

11 VA Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque (nominal torque) Motor Spring return

Transcription:

Radiocontrol F Floor Heating Controller Radio control system for floor heating

IMI HEIMEIER / Floor Heating Control / Radiocontrol F Radiocontrol F The Radiocontrol F radio control system for controlling floor heating systems in individual rooms consists of a microprocessor-controlled central unit and an appropriate number of room transmitters. No cables are required between the room transmitters and central unit. Key features > > Floor heating control without expensive cabling > > Flexible positioning of room transmitters > > Simple installation > > Room transmitter and central unit with and without digital timer > > High transmission security through 868 Mhz radio frequency > > High control accuracy through fuzzy control with PWM > > Removable cover for timer setting > > Backlit display > > 8-channel operation with fieldstrength indication and child safety Technical description Room transmitter without timer Room transmitter designs come with or without operating mode switches. They are electronic fuzzy controllers with integrated sensors. The temperature range can be adjusted between 5 C and 30 C. The room transmitter version with operating mode switch enables you to select day, set-back or automatic mode, or to switch off. In automatic mode, a time-dependent room temperature reduction (approx. 4 K) is activated by a timer integrated into the central unit. Room transmitter with digital timer The room transmitter with digital timer offers 4-key menu operation. The display shows actual room temperature, time, and operating conditions. There is a built-in real-time clock with automatic summer/winter time settings that can be programmed for weekly or daily schedules. Three time programs can be preset and changed if desired. The temperature range can be set between 5 C and 32 C. Through the self-learning heating curve the set temperature is reached at the selected time. Central unit The following versions are available: with 6 output channels with 8 output channels and timer. The cover over the timer can be removed for setting the timer. The display is backlit during mains operation and includes fieldstrength display and child protection. The integrated antenna in the central unit receives the radio signals from the room transmitters. Thermal actuators can be connected to the output channels. The room transmitters can be assigned to one or, in the case of the version featuring 8 output channels, several output channels. An LED is assigned to each output channel to act as an operational status indicator. 2

Construction Radiocontrol F 1. Setting adjuster 2. Button for initial operation or party function 3. Heating/cooling changeover switch 4. Display for room transmitter timer 5. Up/down key for setting 6. Battery compartment 7. Key for operating mode etc. 8. Display for 8-channel timer 9. Connection for cover with timer 10. Connecting terminals for output channels A. Room transmitter with operating mode switch B. Room transmitter with digital timer C. 8-channel central unit with timer D. 6-channel central unit Application The Radiocontrol F system is used in conjunction with twopoint actuators (e.g. EMOtec or EMO T) mounted on a heating circuit manifold, for the purpose of controlling individual room temperatures in floor, wall or ceiling-based heating or cooling systems. It is particularly suitable for upgrading existing floor heating systems, but it is also usable in new buildings because of its flexibly positionable room transmitters and central control unit. With Radiocontrol F the system can be controlled without the need for complex and time-consuming cabling or drilling work. For buildings in which centrally controlled temperature reduction of the overall heating system is not possible or is limited because of varying utilisation periods, the following possibilities are available: Central time-dependent individual room control by the central unit with a digital 8-channel weekly timer. Decentralised dependent individual room control by the room transmitter with a digital timer. An output channel can be used to control a pump. Another output channel can be used for the heating control. Sample application Planning information: Avoid shielding by metal objects, mirrors, thermal insulation glazing, shielding plaster, etc. 1. Room transmitter 2. Central unit 3. Heating circuit manifold with actuators, e.g. EMOtec or EMO T 4. Boiler 3

IMI HEIMEIER / Floor Heating Control / Radiocontrol F Function The room transmitter compares the measured room air temperature (xi) with the set value (xs). If the room air temperature (xi) is less than the set value (xs), the room transmitter issues a demand for heat. If the set value is exceeded, the heat demand is cancelled. The corresponding signal is sent to the receiver in the central unit via radio transmission (868 MHz). Room transmitters with operating mode selector and digital timer can also be changed over to a two-point output signal. For room transmitters with digital timer, the room temperature is maintained between 7 C and 32 C at the preset times. The central unit converts the signals from the room transmitters into fuzzy output signals by means of pulse-width modulation (PWM). These signals are then transmitted to the thermal actuators via switched relay outputs. The central units allow the use of 230 V no-current closed (NC) or no-current open (NO) thermal actuators. One channel can be used for pump control. The 6-channel central unit allows NC and NO actuator models to be used at the same time. 24 V actuators can also be used in conjunction with an external transformer. If radio transmission fails to initiate, the LED for the relevant output channel on the central unit flashes. If it is absent for longer than 10 seconds, an audible signal will be emitted (this can be switched off). In the case of the central unit with integrated 8-channel timer, the room temperature is allowed to fall by approx 4 K at specified times. The room transmitter with an operating mode switch can be internally adjusted for a reduction of 2 K. A total of 6 factory programmed time profiles are available. All profiles can be changed individually. The Radiocontrol F-System can also be set for cooling control, see Technical Data. With the 8-Channel central unit, extra dewpoint sensors, a Hygrostat, or a central temperature reduction control can be incorporated. Function diagrams for operating mode Heating with actuator in no-current closed design with PWM (pulse-width modulation) output signal Key controller Progression of operation time (Key controller) in relation to temperature. *) stroke **) room temperature 4

Connection diagrams Radiocontrol F system with 6-channel central unit Room transmitter; use A) - without switch clock (Art.-No.: 1640-00/01.500) with switch clock (Art.-No.: 1640-02.500) B) - in master / slave mode C) - as self-sufficient room transmitter Room 1 Room 2 Room 3 Room 4 Room 5 Room 6 ----- Channel 1----- ----- Channel 2----- - Channel 3- - Channel 4- - Channel 5- - Channel 6- Please observe instructions Second voltage connection - in total of all I > 2A - SELV - EMO T/tec 24V Attention: Remove BR4/5 EMO T/tec type 230V NC and/or NO: Max. 60 pieces per central unit - max. 10 pieces per output channel; alternative EMO T/tec type 24V max. 24 pieces - 4 pieces/channel - in connection SELV-Trafo 24V AC to terminals 7/8 A) All Channels without timer setting, alternative with/ without BA-switch; B) in master/slave mode: Channel 1 as master, channels 2-6 as slave; C) All other channels without timer setting Radiocontrol F / Central unit, 6-channel and EMO T/tec type 230V NC/NO, channel 6 with pump logic; alternative channel 6 with EMO Radiocontrol F system with 8-channel central unit and timer Room transmitter; use A) - by using the internal time profile, max. 6 various (Art.-No.: 1640-00/01.500) B) - in master / slave mode; e.g. channel-master 5, -slaves 6...8 (Art.-No.: 1640-02.500) Room 1 Room 2 Room 3 Room 4 Room 5 Room 6 (Channel 1/2) (Channel 3/4) (Channel 5) (Channel 5) (Channel 5) (Channel 5) Channel (Room) 7 ans / or Channel (Room) 8 Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Channel 7 Channel 8 Channel 7 potential-free* Channel 8 potential-free* Please observe instructions EMO T/tec type 230 V NC or NO: Max. 15 pieces per central unit / max. 10 pieces per output channel Radiocontrol F / Central unit, 8-channel with clock and actuator EMO T / EMOtec type 230 V NC or NO; alternative channel 7 with control output for oil-/ gas-boiler and / or channel 8 with pump logic 5

IMI HEIMEIER / Floor Heating Control / Radiocontrol F Technical data Room transmitter with/without operating mode switch with digital timer (OMS) Battery, Type / Service life: 2 x Micro 1.5 V, AAA - Alkaline / about 3 years 2 x Mignon 1.5 V, AA - Alkaline / about 2 years Transmission frequency, modulation / aerial: 868,95 MHz, frequency modulation / internal 868,95 MHz, frequency modulation / internal - Range; Transmission interval 100 m free space or 1 Ceiling or 3 Walls; max every 10 min. 100 m free space or 1 Ceiling or 3 Walls; max every 10 min. - Interference resistance; reference retention Automatically-generated address with check process; after battery change Automatically-generated address with check process; after battery change Clock function (preset) Real time with auto. S/W time changeover - Time programme, screen / power reserve 7 Days 5:2 Days/ 24 hours, 1 min / captive - Number Switching programs / times 3 preset (resettable), 2-4 or 6/Days Temperature setting range: 5 C - 30 C (analogue, only for daily operation) 5 C - 32 C (digital, in 0.1 K - steps) - set-back mode (OM heating) by about -4 K (or -2 K, int. Jumper with Type 5 C - 32 C (digital) OMS) - with OM cooling (increase) by about -4 K (or -2 K, int. Jumper with Type 5 C - 32 C (digital) OMS) Control behavior(factory setting): PWM, cycling time 10 min. (total in/out time) PWM, cycling time 10 min. (total in/out time) - Control behavior selectable 2-Point (int. Jumper), only with Type OMS 2-Point (selectable via menu) Temperature sensor / Valve protection NTC-Sensor, internal / switch on with Type NTC-Sensor, internal / switch off, variable OMS Operating modes: Heating or Cooling (Cooling only Type OMS) Heating or Cooling - Operating mode switch Day / Night / Automatic / Off (only Type OMS) By key / LCD in menu Indication: Training mode, Battery low [LED red] Temperature, time, battery and heating status special function Timer 1 15 Hours. (party function): Optimum start, vacation / party timer Protection type, class / permissible air humidity: IP30 as in EN 60529, III (#) as in EN 60730 / max 93 %, non-condensing IP30 as in EN 60529, III (#) as in EN 60730 / max 93 %, non-condensing CE-Certification (NS,EMV / RF): CE as in DIN EN 60730-1, 2...9 / EN 300 220-2, ETSI 301 489-3) CE as in DIN EN 60730-1, 2...9 / EN 300 220-2, ETSI 301 489-3) Storage / ambient temperature in operation: -25 C to +70 C / -25 C to +40 C -25 C to +70 C / -25 C to +40 C Housing, colour, dimensions [mm]: ABS, white (RAL9010), 75 x 75 x 29 ABS, white (RAL9010), 75 x 75 x 29 Fitting: Wall-fixing or flush box Wall-fixing or flush box 6

Central unit 6-channel 8-channel, with timer Operating voltage / frequency: 230 V AC (+10% / -15%), 50/60 Hz 230 V AC (+10% / -15%), 50/60 Hz - power consumption / fuse 3 VA / external 4 VA / fine-wire fuse internal, 4A lag - network connection / length Plug-in ready (EUROplug leads 2 x 0.75 mm²), min 75 cm Plug-in ready (EUROplug leads 2 x 0.75 mm²), min 75 cm Receiving frequency / Antenna: 868.95 MHz, coded for assigned room transmitter / internal 868.95 MHz, coded for assigned room transmitter / internal - Reference retention; behaviour with interference unlimited; channel emergency mode and optoacoustic alarm in event of controller failure unlimited; channel emergency mode and optoacoustic alarm in event of controller failure Number / Function - keyboard: 7 / Start-up, Test; Special function 5 / Start-up, Test; Special function Number / Function - LEDs: 7 / Channel status, Test; Special function; Network 9 / Channel status, Test; Special function; Network Number of output channels: max 6 Channels (= Room transmitter) Max 8 Channels (= Room transmitter) - with pump connected max 5 (Channel 1 to 5; Channel 6 for Pump) Max 7 (Channel 1 to 7; Channel 8 for Pump) - and with heating control connected Max 6 (K.1-6; K.7=Heating; K.8=Pump) - 1 Room transmitter for multiple Channels No (but central unit can be cascaded) Yes (=multiple heating circuits per room transmitter) Relay - output channels: Channel 1-6: Changeover contact Channel 1-6: closing contact, Channel 7-8: Changeover contact - Switching voltage, current ( - current) max 250 V AC, max 6(2) A ( I </= 10(2) A) 230 V AC, max 4(2) A ( I </= 4(2) A) Indication of I (permissible total current) with I > 2 A: 230 V on Kl.7/8 supply Type fine-wire fuse noted with exchange - Number Actuator Type EMO T/tec Total 60.; max 10. per channel Total 15; max 10 per channel - Channel heating, without in / out delay Changeover contact, pot free; max 250 V AC / 4(2) A - Channel pump, with in / out delay Changeover contact; max 250 V AC / 6(2) A Changeover contact, pot free; max 250 V AC / 4(2) A Indication to connect pump / heating With cascading see instructions ext. 230 V used for Heating / Pump Timer (function only with OMS Heating): preset 8-Channel real-time clock - Time profile, preset, resettable 6, div. use; all freely settable - switching distance / accuracy Time base 10 min. / about +/-2 s. per day - switching S/W time / power reserve automatic / about 4 years (int battery) - Programming, stopped / display Remove cover (int battery) / backlit Special function: Activation by terminal assignment or channel or timer keys Activation by terminal assignment or channel or timer keys - Select function type EMO T/tec Types NC and/or NO can be used only Type NC or NO can be used - EMO T/tec: Type 24V (SELV-transformer Total 24; max 4 per Channel - necessary) - changeover of operating mode Cooling by special key-sequence activation Changeover - terminals (external 230 V) Option with cooling function Single spaces can be excepted - Connection dew-point monitoring ext dew-point sensor(s) or Hygrostat - Connection - central set-back function ext 230 V, eg telephone relay, timer - holiday function, can be activated Set-back temperature for max 200 days - Valve, pump protection connectible Factory setting = off; on: daily 10:00 Type and class of protection / permissible humidity: IP40 as in EN 60529, II (Q-Z) as EN 60730 / max 95 %, non-condensing IP40 as in EN 60529, II (Q-Z) as in EN 60730 / max 95 %, non-condensing CE-Certification (NS and EMV): CE as in DIN EN 60730-1 CE as in DIN EN 60730-1 Ambient and storage temperatures: 0 C to +50 C in operation, -20 C to +60 C 0 C to +50 C in operation, -20 C to +60 C Housing, colour / weight: Hard PVC, cream-white RAL9001 / about 530 ABS, white as in RAL9016 / about 850 g g Dimensions (with top rail): 450 mm x 57 mm x 52 mm 310 mm x 90 mm x 65 mm Fitting: Wall mounting of top rail (enclosed) in heatingcircuit manifold; any mounting position Wall mounting of top rail (enclosed) in heatingcircuit manifold; any mounting position 7

IMI HEIMEIER / Floor Heating Control / Radiocontrol F Articles Room transmitter Type EAN Article No with digital timer, incl. battery 4024052763511 1640-02.500 without operating mode switch, incl. battery 4024052556915 1640-01.500 with operating mode switch, incl. battery 4024052556816 1640-00.500 6-channel central unit EAN Article No 4024052557011 1641-00.000 8-channel central unit with timer EAN Article No 4024052557110 1642-00.000 8

Accessories EMOtec Two-point thermal actuator for floor heating systems. With position indicator in NC version. Suitable for all IMI Heimeier thermostatic valve bodies. For technical data, please refer to the EMOtec datasheet. Type EAN Article No 230 V Currentless closed (NC) 4024052460359 1807-00.500 Currentless open (NO) 4024052490752 1809-00.500 24 V Currentless closed (NC) 4024052460458 1827-00.500 Currentless open (NO) 4024052491551 1829-00.500 Connecting to other brands Adapter for mounting EMOtec or EMO T on valve bodies or heating circuit manifolds from other manufacturers. Threads M 30 x 1.5 according to factory standard. Manufacturer EAN Article No Danfoss RA 4024052297016 9702-24.700 Danfoss RAV 4024052300112 9800-24.700 Danfoss RAVL 4024052295913 9700-24.700 Vaillant (Ø 30 mm) 4024052296019 9700-27.700 TA (M28x1,5) 4024052336418 9701-28.700 Herz 4024052296316 9700-30.700 Markaryd 4024052296514 9700-41.700 Comap 4024052296712 9700-55.700 Oventrop (M30x1,0) 4024052428519 9700-10.700 Giacomini 4024052429714 9700-33.700 Ista 4024052511419 9700-36.700 Uponor (Velta) 4024052448111 9700-34.700 - Euro-/compact distributor or return valve 17 Uponor (Velta) - Provario distributor 4024052510917 9701-34.700 Distance plate For installing the room thermostat onto UP boxes. White RAL 9010. 83 mm x 83 mm x 8 mm (W x H x D). EAN Article No 4024052408719 1936-00.433 9

IMI HEIMEIER / Floor Heating Control / Radiocontrol F Dimensions Room transmitter, with digital timer room transmitter, with and without operating mode switch 137 31,3 75 28,5 27,1 25,5 4 96,5 Ø60 6-channel central unit 2,2 50,2 40 97,5 252 452 2,5 57 4,3 8-channel central unit with timer 3 65 46 118 100 310 7 90 10

11

IMI HEIMEIER / Floor Heating Control / Radiocontrol F The products, texts, photographs, graphics and diagrams in this document may be subject to alteration by IMI Hydronic Engineering without prior notice or reasons being given. For the most up to date information about our products and specifications, please visit www.imi-hydronic.com. 2400-18.483 Radiocontrol F ed.2 10.2017