Single-Pole, Normally Closed OptoMOS Relay Parameter Rating Units Load Voltage 6 V P Load Current A rms / A DC On-Resistance (max).6 LED Current to Operate 2 ma Features A Load Current.6 Max On-Resistance 2mA Control Current 37V rms Input/Output Isolation Low Drive Power Requirements (TTL/CMOS Compatible) No Moving Parts High Reliability Arc-Free With No Snubbing Circuits No EMI/RFI Generation Machine Insertable, Wave Solderable Small 6-Pin Package Tape & Reel, Surface Mount Version Available Applications Sensor Circuitry Instrumentation Multiplexers Data Acquisition Electronic Switching I/O Subsystems Meters (gas, oil, electric and water) Medical Equipment-Patient/Equipment Isolation Security Aerospace Industrial Controls Description is a single-pole normally closed (-Form-B) solid state relay that uses optically coupled technology to provide an enhanced 37V rms isolation barrier between the input and the output of the relay. The efficient MOSFET switches use IXYS Integrated Circuits Division's patented OptoMOS architecture. The optically coupled output is controlled by a highly efficient GaAlAs infrared LED. Approvals UL Recognized Component: File E7627 CSA Certified Component: Certificate 7739 EN/IEC 69- Certified Component: TUV Certificate B 9 7 494 4 Ordering Information Part # S STR Pin Configuration Description 6-Lead DIP (/Tube) 6-Lead Surface Mount (/Tube) 6-Lead Surface Mount (/Reel) + Control 6 Load 2 Control Do Not Use 3 Do Not Use 4 Load + Control 2 Control 3 Do Not Use DC Only Configuration 6 4 + Load Load Switching Characteristics of Normally Closed Devices Form-B I LOAD % t off 9% t on Pb e3 DS--R2 www.ixysic.com
Absolute Maximum Ratings @ 2ºC Parameter Ratings Units Blocking Voltage 6 V P Reverse Input Voltage V Input Control Current ma Peak (ms) A Input Power Dissipation mw Total Power Dissipation 2 8 mw Isolation Voltage, Input to Output 37 V rms ESD Rating, Human Body Model 8 kv Operational Temperature -4 to +8 C Storage Temperature -4 to +2 C Derate linearly.33 mw / ºC 2 Derate linearly 6.67 mw / ºC Absolute Maximum Ratings are stress ratings. Stresses in excess of these ratings can cause permanent damage to the device. Functional operation of the device at conditions beyond those indicated in the operational sections of this data sheet is not implied. Electrical Characteristics @ 2ºC Parameter Conditions Symbol Min Typ Max Units Output Characteristics Load Current, Continuous - - A =ma I rms / A DC DC Configuration, Continuous L - - 2 A DC Peak =ma, t < ms I LPK - - ± A P =ma, I L =A -.39.6 R DC Configuration I ON F =ma, I L =2A -..2 On-Resistance Switching Speeds Turn-On t on -.63 3 =ma, V L =V Turn-Off t off -. 3 ms Off-State Leakage Current =2mA, V L =6V I LEAK - - A Output Capacitance =2mA, V L =V, f=mhz C OUT - 2 - pf Input Characteristics Input Control Current to Activate I L =A -.22 2 ma Input Control Current to Deactivate -..2 - ma Input Voltage Drop =ma V F.9.2.4 V Reverse Input Current V R =V I R - - A Common Characteristics Capacitance, Input to Output - C I/O - 3 - pf Measurement taken within second of on-time. R2 2 www.ixysic.com
PERFORMANCE DATA* (@2ºC Unless Otherwise Noted) 3 Typical LED Forward Voltage Drop (N=) 2 Typical Turn-On Time (N=, =ma) 2 Typical Turn-Off Time (N=, =ma) 2 2 2.22.22.23.23.24.24.2 LED Forward Voltage (V).4.7.6.63.66.69.72 Turn-On Time (ms).2.3.4..6.7.8.9 Turn-Off Time (ms) 2 Typical for Switch Operation (N=, I L =A) 2 Typical On-Resistance Distribution =A) 2 Typical Blocking Voltage Distribution (N=, =2mA) 2 2.2.2.22.23.24.2.26 LED Current (ma).38.384.387.39.393.396.399 On -Resistance ( ) 69 7 73 7 77 79 8 Blocking Voltage (V P ) LED Forward Voltage (V).6..4 LED Forward Voltage.3 =ma.2 =2mA =ma. =ma =2mA. Turn-On Time (ms).64.638.636.634.632.63.628.626 Typical Turn-On Time vs. LED Forward Current =ma).624.622.62 2 3 4 LED Forward Current (ma) Turn-Off Time (ms) 8 7 6 4 3 2 Typical Turn-Off Time vs. LED Forward Current =ma) 2 3 4 LED Forward Current (ma) LED Current (ma).32.28.24.2.6 Typical for Switch Operation =ma).2 Turn-On Time (ms).9.8.7.6. Typical Turn-On Time =ma, I L =ma).4 Turn-Off Time (ms) 2.6 2.4 2.2 2..8.6.4 Typical Turn-Off Time =ma, I L =ma).2 *The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. R2 www.ixysic.com 3
PERFORMANCE DATA* (@2ºC Unless Otherwise Noted) Typical On-Resistance =ma, I L =ma).48. Typical Load Current vs. Load Voltage =ma) Maximum Load Current =ma). On-Resistance ( ).44.4.36.32.. -...9.8.7.6.28 -. -.4 -.3 -.2 -....2.3.4 Load Voltage (V). Typical On-Resistance DC-Only Configuration =ma, I L =A).2 2. Load Current vs. Load Voltage DC-Only Configuration =ma) Maximum Load Current DC-Only Configuration =ma) 2.2 On Resistance ( )...9.8... 2..8.6.4.2.7......2.2 Load Voltage (V). Blocking Voltage (V P ) Typical Blocking Voltage =2mA) 8 8 79 78 77 76 7 74 73 Leakage Current ( A)..8.6.4.2 Typical Leakage Current =2mA, V L =6V). Output Capacitence (pf) 4 4 3 3 2 2 Output Capacitance vs. Load Voltage =2mA, f=mhz). Load Voltage (V) Energy Rating Curve.. 4. 4. 3. 3. 2. 2... s s ms ms ms s s s Time *The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. R2 4 www.ixysic.com
Manufacturing Information Moisture Sensitivity All plastic encapsulated semiconductor packages are susceptible to moisture ingression. IXYS Integrated Circuits Division classified all of its plastic encapsulated devices for moisture sensitivity according to the latest version of the joint industry standard, IPC/JEDEC J-STD-2, in force at the time of product evaluation. We test all of our products to the maximum conditions set forth in the standard, and guarantee proper operation of our devices when handled according to the limitations and information in that standard as well as to any limitations set forth in the information or standards referenced below. Failure to adhere to the warnings or limitations as established by the listed specifications could result in reduced product performance, reduction of operable life, and/or reduction of overall reliability. This product carries a Moisture Sensitivity Level (MSL) rating as shown below, and should be handled according to the requirements of the latest version of the joint industry standard IPC/JEDEC J-STD-33. Device Moisture Sensitivity Level (MSL) Rating / S MSL ESD Sensitivity This product is ESD Sensitive, and should be handled according to the industry standard JESD-62. Reflow Profile This product has a maximum body temperature and time rating as shown below. All other guidelines of J-STD-2 must be observed. Device / S Maximum Temperature x Time 2ºC for 3 seconds Board Wash IXYS Integrated Circuits Division recommends the use of no-clean flux formulations. However, board washing to remove flux residue is acceptable. Since IXYS Integrated Circuits Division employs the use of silicone coating as an optical waveguide in many of its optically isolated products, the use of a short drying bake could be necessary if a wash is used after solder reflow processes. Chlorine- or Fluorine-based solvents or fluxes should not be used. Cleaning methods that employ ultrasonic energy should not be used. Pb e3 R2 www.ixysic.com
Mechanical Dimensions 8.382 ±.38 (.33 ±.) 2.4 ±.27 (. ±.) Pin.6 ±.24 (.6 ±.) 6.3 ±.27 (.2 ±.) 7.62 ±.24 (.3 ±.) 7.239 TYP (.28 TYP) 9.44 ±.8 (.36 ±.2).24 ±.27 (. ±.) 6 -.8 DIA. (6 -.3 DIA.) 6.3 ±.27 (.2 ±.) PCB Hole Pattern 2.4 ±.27 (. ±.).8 ±.27 (.2 ±.) 7.62 ±.27 (.3 ±.) 3.32 ±. (.3 ±.2).47 ±.76 (.8 ±.3) 4.64 TYP (.6 TYP) Dimensions mm (inches) S 8.382 ±.38 (.33 ±.) 2.4 ±.27 (. ±.).63 ±.27 (.2 ±.) PCB Land Pattern 2.4 (.) 9.24 ±.8 (.37 ±.2) Pin 3.32 ±. (.3 ±.2).47 ±.76 (.8 ±.3).6 ±.24 (.6 ±.) 6.3 ±.27 (.2 ±.) 7.62 ±.24 (.3 ±.).24 ±.27 (. ±.).6 (.649).6 (.2) 8.9 (.33) 4.44 ±.24 (.7 ±.).6 ±.24 (.6 ±.) Dimensions mm (inches) R2 6 www.ixysic.com
STR Tape & Reel 33.2 Dia (3. Dia) Top Cover Tape Thickness.2 Max (.4 Max) W=6. (.63) B =. (.398) Embossed Carrier Embossment K = 4.9 (.9) K = 3.8 (.) P = 2. (.472) User Direction of Feed A =. (.398) Dimensions mm (inches) NOTES:. All dimensions carry tolerances of EIA Standard 48-2 2. The tape complies with all Notes for constant dimensions listed on page of EIA-48-2 For additional information please visit our website at: www.ixysic.com IXYS Integrated Circuits Division makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make changes to specifications and product descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in IXYS Integrated Circuits Division s Standard Terms and Conditions of Sale, IXYS Integrated Circuits Division assumes no liability whatsoever, and disclaims any express or implied warranty, relating to its products including, but not limited to, the implied warranty of merchantability, fitness for a particular purpose, or infringement of any intellectual property right. The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other applications intended to support or sustain life, or where malfunction of IXYS Integrated Circuits Division s product may result in direct physical harm, injury, or death to a person or severe property or environmental damage. IXYS Integrated Circuits Division reserves the right to discontinue or make changes to its products at any time without notice. 7 Specification: DS--R2 Copyright 22, IXYS Integrated Circuits Division OptoMOS is a registered trademark of IXYS Integrated Circuits Division All rights reserved. Printed in USA. 2/22/22