Voltage Sag and Swell Mitigation Using Dynamic Voltage Restore (DVR)

Similar documents
Power Quality Improvement by DVR

MITIGATION OF VOLTAGE SAGS/SWELLS USING DYNAMIC VOLTAGE RESTORER (DVR)

Simulation and Comparison of DVR and DSTATCOM Used For Voltage Sag Mitigation at Distribution Side

ISSN Vol.07,Issue.21, December-2015, Pages:

Protection from Voltage Sags and Swells by Using FACTS Controller

Analysis, Modeling and Simulation of Dynamic Voltage Restorer (DVR)for Compensation of Voltage for sag-swell Disturbances

Power Quality enhancement of a distribution line with DSTATCOM

Application of Dynamic Voltage Restorer for Voltage Balancing with ASD Load Using DQO Transformation

Design Strategy for Optimum Rating Selection of Interline D-STATCOM

Enhancement of Power Quality in Distribution System Using D-Statcom for Different Faults

Investigation of Dynamic Voltage Restorer for Compensation of Voltage Sag and Swell

Design and Simulation of DVR Used For Voltage Sag Mitigation at Distribution Side

Analysis and modeling of thyristor controlled series capacitor for the reduction of voltage sag Manisha Chadar

Mitigating Voltage Sag Using Dynamic Voltage Restorer

SUPERCONDUCTING MAGNETIC ENERGY

Harmonic Reduction in Five Level Inverter Based Dynamic Voltage Restorer

Mitigation of Voltage Sag and Swell using Distribution Static Synchronous Compensator (DSTATCOM)

CHAPTER 4 PV-UPQC BASED HARMONICS REDUCTION IN POWER DISTRIBUTION SYSTEMS

CHAPTER 5 DESIGN OF DSTATCOM CONTROLLER FOR COMPENSATING UNBALANCES

Modelling of Dynamic Voltage Restorer for Mitigation of Voltage Sag and Swell Using Phase Locked Loop

Improvement of Voltage Profile using D- STATCOM Simulation under sag and swell condition

Improvement of Power Quality in Distribution System using D-STATCOM With PI and PID Controller

A CONTROL TECHNIQUE FOR INSTANT MITIGATION OF VOLTAGE SAG/SWELL BY DYNAMIC VOLTAGE RESTORER

II. RESEARCH METHODOLOGY

Design of Dynamic Voltage Restorer for three phase network as steady state device in the Distribution System

Design Requirements for a Dynamic Voltage Restorer for Voltage Sags Mitigation in Low Voltage Distribution System

ENHANCEMENT OF POWER QUALITY BY INJECTING SERIES VOLTAGE USING DVR

Literature Review for Shunt Active Power Filters

Unit.2-Voltage Sag. D.Maharajan Ph.D Assistant Professor Department of Electrical and Electronics Engg., SRM University, Chennai-203

Simulation and Implementation of DVR for Voltage Sag Compensation

International Journal of Advance Engineering and Research Development CONTROL OF REDUCED-RATING DYNAMIC VOLTAGE RESTORER

Synchronous Reference Frame Theory (SRF) along with PI Controller Based Dynamic Voltage Restorer

Adaptive ANN based STATCOM and DVR for optimal integration of wind energy with grid using permanent magnet synchronous generator

A Novel Approach to Simultaneous Voltage Sag/Swell and Load Reactive Power Compensations Using UPQC

MITIGATION OF VOLTAGE SAG IN A DFIG BASED WIND TURBINE USING DVR

Multi level DVR with Energy Storage System for Power Quality Improvement

ISSN Vol.03,Issue.11, December-2015, Pages:

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

Mitigation of voltage disturbances (Sag/Swell) utilizing dynamic voltage restorer (DVR)

Z-SOURCE INVERTER BASED DVR FOR VOLTAGE SAG/SWELL MITIGATION

SIMULATION OF D-STATCOM IN POWER SYSTEM

Modelling And Analysis of DVR With SEPIC Converter And Supercapacitor

Modelling and Simulation of SVM Based DVR System for Voltage Sag Mitigation

CHAPTER 5 CONTROL SYSTEM DESIGN FOR UPFC

Sag/Swell Compensation and Displacement Factor Improvement using IDVR in Distribution Network

Improvement of Dynamic Voltage Restorer (DVR) Using Proportional Integral (PI)Controller for Mitigation of Voltage Sag

A Versatile Control Scheme for UPQC for Power Quality Improvement using fuzzy controller

STATCOM WITH POD CONTROLLER FOR REACTIVE POWER COMPENSATION Vijai Jairaj 1, Vishnu.J 2 and Sreenath.N.R 3

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

Mitigation of Voltage Sag and Swell Using Dynamic Voltage Restorer

Performance of DVR under various Fault conditions in Electrical Distribution System

New Direct Torque Control of DFIG under Balanced and Unbalanced Grid Voltage

Application of Distribution Static Synchronous Compensator in Electrical Distribution System

A DYNAMIC VOLTAGE RESTORER (DVR) BASED MITIGATION SCHEME FOR VOLTAGE SAG AND SWELL

Mitigation of voltage sag by using AC-AC PWM converter Shalini Bajpai Jabalpur Engineering College, M.P., India

Stability Enhancement for Transmission Lines using Static Synchronous Series Compensator

ICCCES Application of D-STATCOM for load compensation with non-stiff sources

Simulation of a Dynamic Voltage Restorer to Compensate Voltage Sag for Improving Power Quality

Compensation of Different Types of Voltage Sags in Low Voltage Distribution System Using Dynamic Voltage Restorer

Volume I Issue VI 2012 September-2012 ISSN

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

CHAPTER 4 POWER QUALITY AND VAR COMPENSATION IN DISTRIBUTION SYSTEMS

A Voltage Controlled D-STATCOM for Power Quality Improvement with DVR

DRIVE FRONT END HARMONIC COMPENSATOR BASED ON ACTIVE RECTIFIER WITH LCL FILTER

Chapter -3 ANALYSIS OF HVDC SYSTEM MODEL. Basically the HVDC transmission consists in the basic case of two

Power Quality Improvement using Hysteresis Voltage Control of DVR

Design Requirements for a Dynamic Series Compensator for Voltage Sags Mitigation in Low Voltage Distribution System

SIMULATION OF D-STATCOM AND DVR IN POWER SYSTEMS

COMPENSATION OF VOLTAGE SAG USING LEVEL SHIFTED CARRIER PULSE WIDTH MODULATED ASYMMETRIC CASCADED MLI BASED DVR SYSTEM G.Boobalan 1 and N.

Power Quality and the Need for Compensation

SUPER CONDUCTING MAGNETIC ENERGY SYSTEM WITH DVR FOR VOLTAGE QUALITY IMPROVEMENT USING PSO BASED SIMPLE ABC FRAME THEORY

Ghazanfar Shahgholian *, Reza Askari. Electrical Engineering Department, Najafabad Branch, Islamic Azad University, Isfahan, Iran

Optimum placement of capacitor in distribution system using a DVR with ANN Technique

OVERVIEW OF DVR FOR POWER QUALITY IMPROVEMENT

Voltage Quality Enhancement in an Isolated Power System through Series Compensator

Application of Fuzzy Logic Controller in Shunt Active Power Filter

Mitigation of voltage sags/swells unbalanced in low voltage distribution systems

Improvement Voltage Sag And Swell Under Various Abnormal Condition Using Series Compensation

Self-Tuning PI Control of Dynamic Voltage Restorer Using Fuzzy Logic

Power Control Scheme of D-Statcom

Power Conditioning Equipment for Improvement of Power Quality in Distribution Systems M. Weinhold R. Zurowski T. Mangold L. Voss

INTERLINE UNIFIED POWER QUALITY CONDITIONER: DESIGN AND SIMULATION

Performance of DVR & Distribution STATCOM in Power Systems

A REVIEW PAPER ON REGULATION TECHNIQUE FOR VOLTAGE SAG AND SWELL USING DVR

Load Compensation at a Reduced DC Link Voltage by Using DSTATCOM with Non-Stiff Source

ITEE Journal. Information Technology & Electrical Engineering International Journal of Information Technology and Electrical Engineering

Enhancement of Voltage Stability & reactive Power Control of Distribution System Using Facts Devices

Voltage Sag and Mitigation Using Dynamic Voltage Restorer (DVR) System

A Voltage Controlled DSTATCOM using Hybrid Renewable Energy DC Link VSI for Power Quality Improvement

Cascaded H-Bridge Five Level Inverter for Harmonics Mitigation and Reactive Power Control

Voltage Sags in Distribution Systems with Induction Motor Loads Fed by Power Converters and Voltage Mitigation using DVR and D-STATCOM

A Power Control Scheme for UPQC for Power Quality Improvement

OVERVIEW OF SVC AND STATCOM FOR INSTANTANEOUS POWER CONTROL AND POWER FACTOR IMPROVEMENT

Auxiliary DC Voltage

MODELING AND ANALYSIS OF IMPEDANCE NETWORK VOLTAGE SOURCE CONVERTER FED TO INDUSTRIAL DRIVES

A VOLTAGE SAG/SWELL ALONG WITH LOAD REACTIVE POWER COMPENSATION BY USING SERIES INVERTER of UPQC-S

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

MAHALAKSHMI ENGINEERING COLLEGE TIRUCHIRAPALLI

Fundamentals of Power Electronics

Power Quality Improvement in Distribution System Using D-STATCOM

Transcription:

Voltage Sag and Swell Mitigation Using Dynamic Voltage Restore (DVR) Mr. A. S. Patil Mr. S. K. Patil Department of Electrical Engg. Department of Electrical Engg. I. C. R. E. Gargoti I. C. R. E. Gargoti ajitpatil03@gmail.com sarjerao75@rediffmail.com Abstract The dynamic voltage restorer (DVR) is one of the modern devices used in distribution systems to protect consumers against sudden changes in voltage amplitude. In this paper, emergency control in distribution systems is discussed by using DVR control strategy. Also, the multi-loop Controller using the Posicast and P + Resonant controllers is proposed in order to improve the transient response and eliminate the steady-state error in DVR response, respectively. The proposed algorithm is applied to some disturbances in load voltage caused by induction motors starting, and a three-phase short circuit fault, Double line to Ground faults, Single line to ground faults. Keywords -- Dynamic voltage restorer (DVR), emergency control, voltage sag, voltage swell. I. INTRODUCTION The dynamic voltage restorer (DVR) is a series voltage controller which is connected in series with the protected load as shown in Figure 1. Usually the connection is made via a transformer, but configurations with direct connection via power electronics also exist. The resulting voltage at the load bus bar equals the sum of the grid voltage and the injected voltage from the DVR. The converter generates the reactive power needed while the active power is taken from the energy storage. The energy storage can be different depending on the needs of compensating. The DVR often has limitations on the depth and duration of the voltage dip that it can compensate. Therefore right sized has to be used in order to achieve the desired protection. Options available for energy storage during voltage dips are conventional capacitors for very short durations but deep, batteries for longer but less severe magnitude Drops and super capacitors in between. There are also other combinations and configurations used in practice. There are configurations, which can work without any energy storage, and they inject a lagging voltage with the load current. Fig. 1. Typical DVR connected distribution system There are also different approaches on what to inject to obtain the most powerful solution. The main advantage with this method is that a single DVR can be installed to protect a whole plant (a few MVA) as well as Single loads. Because of the fast switches, usually IGBT s, voltage compensation can be achieved in less than half a cycle. Disadvantages are that it is relatively expensive and it only mitigates voltage dips from outside the site. The cost of a DVR mainly depends on the power rating and the energy storage capacity. It is used to improve the power quality condition in the transmission as well as in distribution line. DVR is basically a power electronic device comprising of an inverter, energy storage device and a LC filter at the output of inverter [1]. This basic structure may have coupling transformer to couple 1

it with transmission or distribution line. In a transmission line, it is used to improve maximum transmissible power, voltage stability, and transient stability and damp the power oscillations. In distribution system it is used to mitigate sag and also used as an active filter for harmonic compensation. II. BASIC OPERATIONAL PRINCIPLE OF DVR The DVR system shown in Fig. 1, controls the load voltage by injecting an appropriate voltage phasor in series with the system using the injection series transformer. In most of the sag compensation techniques, it is necessary that during compensation, the DVR injects some active power to the system. Therefore, the capacity of the storage unit can be a limiting factor in compensation, especially during long-term voltage sags. The phasor diagram in Fig. 2, shows the electrical conditions during voltage sag, where, for clarity, only one phase is shown. Voltages,, and are the source-side voltage, the load- side voltage, and the DVR injected voltage, respectively. Also, the operators I,,, and are the load current, the load power factor angle, the source phase voltage angle, and the voltage phase advance angle, respectively [24]. It should be noted that in addition to the in-phase injection technique, another technique, namely the phase advance voltage compensation technique is also used [24]. One of the advantages of this method over the in-phase method is that less active power should be transferred from the storage unit to the distribution system. This results in compensation for deeper sags or sags with longer duration. Due to the existence of semiconductor switches in the DVR inverter, this piece of equipment is nonlinear. However, the state equations can be linearized using linearization techniques. The dynamic characteristic of the DVR is influenced by the filter and the load. Although the modeling of the filter (that usually is a simple LC circuit) is easy to do, the load modeling is not as simple because the load can vary from a linear time invariant one to a nonlinear time-variant one. In this paper, the simulations are performed with two types of loads: 1) a constant power load 2) a motor load. As Fig. 3 shows, the load voltage is regulated by the DVR through injecting. For simplicity, the bypass switch shown in Fig. 1 is not presented in this figure. Here, it is assumed that the load has a resistance and an inductance. The DVR harmonic filter has an inductance of, a resistance of, and a capacitance of. Also, the DVR injection transformer has a combined winding resistance of, a leakage inductance of, and turns ratio of The Posicast controller is used in order to improve the tran- sient response. Fig. 4 shows a typical control block diagram of the DVR. The Posicast controller is used in order to improve the tran- sient response. Fig. 4 shows a typical control block diagram of the DVR. Note that because in real situations, we are dealing with multiple feeders connected to a common bus, namely the FIG. 2. DVR USING PRESAGE VOLTAGE Fig. 3. Distribution system with the DVR. 2

Fig. 4. Open-loop control using the Posicast controller. Point of Common Coupling (PCC), from now on, and will be replaced with and, respectively, to make a generalized sense. As shown in the figure, in the open-loop control, the voltage on the source side of the DVR is compared with a load side reference voltage so that the necessary injection voltage is derived. A simple method to continue is to feed the error signal into the PWM inverter of the DVR. But the problem with this is that the transient oscillations initiated at the start instant from the voltage sag could not be damped sufficiently. To improve the damping, as shown in Fig. 4, the Posicast controller can be used just before transferring the signal to the PWM inverter of the DVR. The transfer function of the controller can be described as follows: ensuring fast dynamic tracking through the feedforward path and a second degree of freedom for the independent tuning of the system disturbance compensation through the feedback path [12]. The feedback path consists of an outer voltage loop and a fast inner current loop. To eliminate the steady-state voltage tracking error, a computationally less intensive P+Resonant compensator is added to the outer voltage loop. The ideal P+Resonant compensator can be mathematically expressed as where and are gain constants and is the controller resonant frequency. Theoretically, the resonant controller compensates by introducing an infinite gain at the resonant frequency of 50 Hz (Fig. 6) to force the steady-state voltage error to zero. The ideal resonant controller, however, acts like a network with an infinite quality factor, which is not realizable in practice. A more practical (nonideal) compensator is therefore used here, and is expressed as 1+P(S) = 1+(δ/(1+δ))[-1+e(Td/2) ----- (1) Then, according to (2) and the definitions of damping and the delay time in the control literature, and are derived as follows: The Posicast controller works by pole elimination, and proper regulation of its parameters is necessary. For this reason, it is sensitive to inaccurate information of the system damping res- onance frequency. To decrease this sensitivity, as is shown in Fig. 5, the open-loop controller can be converted to a closed- loop controller by adding a multiloop feedback path parallel to the existing feedforward path. Inclusion of a feedforward and a feedback path is commonly referred to as two-degrees-of- freedom (2-DOF) control in the literature. As the name im- plies, 2-DOF control provides a DOF for where and are the step response overshoot and the period of damped response signal, respectively. It should be noted that the Posicast controller has limited high-frequency gain; hence, low sensitivity to noise. To find the appropriate values of and, first the DVR model will be derived according to Fig. 3, as follows: where is the compensator cutoff frequency which is 1 rad/s in this application [12]. Plotting the frequency response of (5), as in Fig. 6, it is noted that the resonant peak now has a finite gain of 40 db which is 3

sat- isfactorily high for eliminating the voltage tracking error [12]. In addition, a wider bandwidth is observed around the resonant frequency, which minimizes the sensitivity of the compensator to slight utility frequency variations. At other harmonic frequen- cies, the response of the nonideal controller is comparable to that of the ideal one. III. PROPOSED MULTIFUNCTIONAL DVR In addition to the aforementioned capabilities of DVR, it can be used in the medium-voltage level (as in Fig. 7) to protect a group of consumers when the cause of disturbance is in the downstream of the DVR s feeder and the large fault current passes through the DVR itself. In this case, the equipment can limit the fault current and protect the loads in parallel feeders until the breaker works and disconnects the faulted feeder. The large fault current will cause the PCC voltage to drop and the loads on the other feeders connected to this bus will be affected. Furthermore, if not controlled properly, the DVR might also contribute to this PCC voltage sag in the process of compensating the missing voltage, hence further worsening the fault situation [11]. IV. SIMULATION RESULTS rated at 6000 kvar. As is typically done, In this part, the proposed DVR topology and control algorithm will be used for emergency control during the voltage sag. The three-phase short circuit and the start of a three-phase large induction motor will be considered as the cause of distortion in the simulations. A. UNDER STUDY TEST SYSTEM In this paper, the IEEE standard 13-bus balanced industrial system will be used as the test system. The one-line diagram of this system is shown in Fig. 9. The plant is fed from a utility supply at 69 kv and the local plant distribution system operates at 13.8 kv. The local (in-plant) generator is represented as a simple Thevenin equivalent. The internal voltage, determined from the converged power-flow solution, is kv. The equivalent impedance is the sub transient impedance which is. The plant power factor correction capacitors are CASE I THREE PHASE SHORT CIRCUIT The first case is three phase short circuit. The three phase short circuit is applied on bus name 26: FDR: G. The fault duration is from 205 millisecond to 285 millisecond. At this time the breaker works and the faulty line is separated from the system. The separated line is between 03 : mill : 1bus and 26 : FDR : G bus. At time t = 305 millisecond the fault is cleared. At time t = 310 millisecond the faulted line is rejoined to the system by the breaker. The results are given in figure below: CASE II DOUBLE LINE TO GROUND FAULT The Second case is Double Line to ground fault. The LLG fault is applied on bus name 6: FDR: H. The fault duration is from 205 millisecond to 285 millisecond. At this time the breaker works and the faulty line is separated from the system. The separated line is between 03 : mill : 1bus and 6 : FDR : H bus. At time t = 305 millisecond the fault is cleared. At time t 4

= 310 millisecond the faulted line is rejoined to the system by the breaker. The results are given in figure below Fig. 5. Simulation Result of Three Phase Short Circuit CASE III SINGLE LINE TO GROUND FAULT The third case is Single Line to ground fault. The LG fault is applied on bus name 6: FDR: H. The fault duration is from 205 millisecond to 285 millisecond. At this time the breaker works and the faulty line is separated from the system. The separated line is between 03 : mill : 1bus and 6 : FDR : H bus. At time t = 305 millisecond the fault is cleared. At time t = 310 millisecond the faulted line is rejoined to the system by the breaker. The results are given in figure below: Fig. 6. Simulation Result of Double Line to Ground Fault V. CONCLUSION This paper presents the solution for the one major power quality problem i.e. voltage sag. For this purpose a custom power device dynamic voltage restorer is used in distribution system. In this thesis, a multifunctional Dynamic Voltage Restorer is proposed. In first part the hysteresis voltage control technique is used to generate the switching pulses for the inverter of DVR. One another closed-loop control system is used for its control to improve the damping of the DVR response. Also, for further improving the transient response and eliminating the steady-state error, the Posicast and P+Resonant controllers are used. The Posicast controller and proportional resonant controller are designed in Matlab software by using the transfer function. As the second function of this DVR, using the flux-charge model, the equipment is controlled so that it limits the downstream fault currents and protects the PCC voltage during these faults by acting as variable impedance. The 13 bus IEEE balanced industrial distribution system is used as a test system to check the performance of dynamic voltage restorer to compensate the missing voltage. The test system is designed in MATLAB software.. VI. REFERENCES [1] Rosli Omar, Nasrudin Abd Rahim, (2009) New Control Technique Applied in Dynamic Voltage Restorer for Voltage Sag Mitigation, IEEE [2] C. Benachaiba and B. Ferdi, (2008) Voltage quality improvement using DVR, Electrical Power Quali ty and Utilization, Journal, vol. XIV, no. 1. [3] S.Deepa and Dr. S. Rajapandian, (2010) Implementation of Dynamic Voltage Restorer for 5

Voltage Sag Mitigation International Journal of Engineering Science and Technology Vol. 2(10), 5825-5830 [4] H. Kim, (2002) Minimal Energy Control for A Dynamic Voltage Restorer, Power Conversion Conference, PCC Osaka, Vol. 2, pp. 428-433 [5] A. Ghosh and G. Ledwich, Power Quality Enhancement Using Custom Power Devices Kluwer Academic Publishers, 2002 [6] Y. W. Li, D. M. Vilathgamuwa, P. C. Loh, and F. Blaabjerg, A dual functional medium voltage level DVR to limit downstream fault currents, IEEE Trans. Power Electronics, vol. 22, no. 4, pp. 1330 1340, Jul. 2007.. 46th ISTE Annual National Convention & National Conference 2017 6