Mitigation of Voltage Sag and Swell Using Distributed Power Flow Controller

Similar documents
Power Quality Improvement And Mitigation Of Voltage Sag And Current Swell Using Distributed Power Flow Controller

Enhancement of Power Quality in Multi Feeders by using MC-DPFC

SIMULATION OF DISTRIBUTED POWER FLOW CONTROLLER FACTS DEVICE IN VOLTAGE SAG AND SWELL MITIGATION

Power Quality Enhancement and Mitigation of Voltage Sag using DPFC

MITIGATION OF VOLTAGE SAG AND SWELL FOR POWER QUALITY IMPROVEMENT USING DISTRIBUTED POWER FLOW CONTROLLER

Performance Of Distributed Power Flow Controller (DPFC) Under Fault Condition

Modeling and Analysis of DPFC to Improve Power Quality

A Fuzzy based MC-DPFC for Enhancement of Power Quality in Transmission Line

Mitigation of Voltage Sag and Swell by Ant Colony Optimization Technique using DPFC

Power Control Scheme of D-Statcom

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

Compensation of Distribution Feeder Loading With Power Factor Correction by Using D-STATCOM

Designing Of Distributed Power-Flow Controller

Direct and Indirect Control Strategies of DSTATCOM Power Factor Controller

Mitigation of Voltage Sag/Swell Using UPQC

Harmonic Immunity And Power Factor Correction By Instantaneous Power Control Of D-STATCOM

Enhancement of Power Quality Using Advanced Series Active Power Filters

Power Quality Improvement in Distribution System Using D-STATCOM

ISSN Vol.07,Issue.21, December-2015, Pages:

Implementation of D-STACTOM for Improvement of Power Quality in Radial Distribution System

IJCSIET--International Journal of Computer Science information and Engg., Technologies ISSN

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

A NOVEL APPROACH ON INSTANTANEOUS POWER CONTROL OF D-STATCOM WITH CONSIDERATION OF POWER FACTOR CORRECTION

Simulation and Comparison of DVR and DSTATCOM Used For Voltage Sag Mitigation at Distribution Side

Improvement of Power Quality in Distribution System using D-STATCOM With PI and PID Controller

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

SIMULATION OF D-STATCOM AND DVR IN POWER SYSTEMS

OVERVIEW OF SVC AND STATCOM FOR INSTANTANEOUS POWER CONTROL AND POWER FACTOR IMPROVEMENT

Harmonics Reduction and Power Quality Improvement by using Multilevel DPFC

Mitigation of Fault in the Distribution System by using Flexible Distributed Static Compensator (FD-STATCOM)

PSPWM Control Strategy and SRF Method of Cascaded H-Bridge MLI based DSTATCOM for Enhancement of Power Quality

IJESR/Nov 2012/ Volume-2/Issue-11/Article No-21/ ISSN International Journal of Engineering & Science Research

29 Level H- Bridge VSC for HVDC Application

Modeling and Simulation of SRF and P-Q based Control DSTATCOM

STATCOM WITH POD CONTROLLER FOR REACTIVE POWER COMPENSATION Vijai Jairaj 1, Vishnu.J 2 and Sreenath.N.R 3

Mitigation of Voltage Sag, Swell and Load Hamonics by the Combined Opertation of Series APF and Solar System

Simulation of Multi Converter Unified Power Quality Conditioner for Two Feeder Distribution System

Power Quality Improvement in Fourteen Bus System using UPQC

A Control Scheme for Dual Unified Power Quality Conditioner to Improve Power Quality

Improvement of Voltage Profile using D- STATCOM Simulation under sag and swell condition

Improvement of Power Quality Using Hybrid Active Power Filter in Three- Phase Three- Wire System Applied to Induction Drive

Unit Vector Theory based Unified Power Quality Conditioner for Power Quality Improvement

Mitigation of Faults in the Distribution System by Distributed Static Compensator (DSTATCOM)

ISSN Vol.04,Issue.16, October-2016, Pages:

Power Quality and the Need for Compensation

Voltage Flicker Compensation using STATCOM to Improve Power Quality

Cascaded H-Bridge Five Level Inverter for Harmonics Mitigation and Reactive Power Control

Power Quality enhancement of a distribution line with DSTATCOM

SIMULATION OF DSTATCOM FOR POWER FACTOR IMPROVEMENT

Design and Simulation of DVR Used For Voltage Sag Mitigation at Distribution Side

Application of Distribution Static Synchronous Compensator in Electrical Distribution System

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

A Modified Control Method For A Dual Unified Power Quality Conditioner

An Advanced Full-Bridge Three Level DC-DC Converter with Voltage Balancing Control Technique for Wind Power Systems

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

Interline Power Quality Conditioner for Power Quality Improvement

Power System Stability Enhancement Using Static Synchronous Series Compensator (SSSC)

Power angle control of UPQC to compensate load reactive power and voltage sag /swells

International Journal of Scientific & Engineering Research, Volume 6, Issue 8, August ISSN

ANALYSIS OF UNIFIED POWER QUALITY CONDITIONER DURING VOLTAGE SAG AND SWELL CONDITIONS

Performance of DVR under various Fault conditions in Electrical Distribution System

Synchronous Reference Frame Theory (SRF) along with PI Controller Based Dynamic Voltage Restorer

Improvement of System Reliability & Power Transfer Capability using Distributed Power- Flow Controller (DPFC)

Stability Enhancement for Transmission Lines using Static Synchronous Series Compensator

Voltage Sags in Distribution Systems with Induction Motor Loads Fed by Power Converters and Voltage Mitigation using DVR and D-STATCOM

A Novel Approach to Simultaneous Voltage Sag/Swell and Load Reactive Power Compensations Using UPQC

Shunt Active Power Filter based on SRF theory and Hysteresis Band Current Controller under different Load conditions

Mitigating Voltage Sag Using Dynamic Voltage Restorer

Ripple Reduction Using Seven-Level Shunt Active Power Filter for High-Power Drives

Development and Simulation of Dynamic Voltage Restorer for Voltage SAG Mitigation using Matrix Converter

Designing and Control of Converters used in DPFC for Mitigation of Voltage Sag and Swell In Transmission Line

Voltage Improvement Using SHUNT FACTs Devices: STATCOM

A Voltage Controlled D-STATCOM for Power Quality Improvement with DVR

Volume I Issue VI 2012 September-2012 ISSN

SOLAR POWERED REACTIVE POWER COMPENSATION IN SINGLE-PHASE OPERATION OF MICROGRID

Simulation of D-STATCOM for Power Quality Improvement With Fuzzy Based Phase Locked Loop Control Strategy

Bhavin Gondaliya 1st Head, Electrical Engineering Department Dr. Subhash Technical Campus, Junagadh, Gujarat (India)

ISSN: Page 20. International Journal of Engineering Trends and Technology- Volume2Issue3-2011

ISSN Vol.04,Issue.08, July-2016, Pages:

Design of Unified Power Quality Conditioner (UPQC) Connected To Three Phase Four Wire System

Enhancement of Power Quality in Distribution System Using D-Statcom for Different Faults

Design Strategy for Optimum Rating Selection of Interline D-STATCOM

Enhancement of Power Quality in Distribution System Using D-Statcom

Power Quality Improvement using Hysteresis Voltage Control of DVR

CHAPTER 5 DESIGN OF DSTATCOM CONTROLLER FOR COMPENSATING UNBALANCES

Power-Quality Improvement with a Voltage-Controlled DSTATCOM

A VOLTAGE SAG/SWELL ALONG WITH LOAD REACTIVE POWER COMPENSATION BY USING SERIES INVERTER of UPQC-S

Manjeet Baniwal 1, U.Venkata Reddy 2, Gaurav Kumar Jha 3

Protection from Voltage Sags and Swells by Using FACTS Controller

REDUCTION OF THD IN POWER SYSTEMS USING STATCOM

Mitigation of Voltage Sag and Swell using Distribution Static Synchronous Compensator (DSTATCOM)

Selective Harmonic Elimination Using Three Phase Shunt Active Power Filter

ISSN Vol.03,Issue.11, December-2015, Pages:

POWER QUALITY IMPROVEMENT BY USING ACTIVE POWER FILTERS

Improvement of Power Quality using Unified Power Quality Conditioner with Distributed Generation

DIGITAL SIMULATION OF MULTILEVEL INVERTER BASED STATCOM

Harmonics Elimination Using Shunt Active Filter

Analysis and modeling of thyristor controlled series capacitor for the reduction of voltage sag Manisha Chadar

CHAPTER 4 POWER QUALITY AND VAR COMPENSATION IN DISTRIBUTION SYSTEMS

SIMULATION RESULTS OF EIGHT BUS SYSTEM USING PUSH-PULL INVERTER BASED STATCOM

Transcription:

Mitigation of Voltage Sag and Swell Using Distributed Power Flow Controller P.Rajasekhar 1, Ch.Narayana 2 Assistant Professor, Dept. of EEE S.V.P.C.E.T Puttur, chittore, Andhra Pradesh India 1 P.G Student, Dept.of EEE, M.Tech (E.P.S) S.V.P.C.E.T Puttur, chittore Andhra Pradesh India 2 ABSTRACT: Modern power utilities have to respond to a number of challenges such as growth of electricity demand especially in non-linear loads in power grids; consequently,that higher power quality should be considered. In this paper, DPFC which is similar to unified power flow controller (UPFC) in structure, which is used to mitigate the voltage sag and swell as a power quality issue. Unlike UPFC, the common dc-link in DPFC, between the shunt and series converter devices should be eliminated and three-phase series converter is divided to several single-phase series distributed converters through the power transmission line. And also to detect the voltage sags and find out the three single-phase reference voltages of DPFC, the synchronous reference frame method is proposed. Application of DPFC in power quality enhancement is simulated in Mat lab/simulink environment which show the effectiveness of the proposed structure KEYWORDS: FACTS, power quality, sag and swell mitigation, distributed power flow controller. I. INTRODUCTION Recent developments in the electric utility industry are encouraging the entry of power quality issue [1]. Extending from the generation units to the utility customers, power quality is a measure of how the elements affect the system as a whole [2]. From customer point of view, the power quality issue is concerned about current, voltage or frequency deviation which results in power failure [3]. To solve the power quality problem in such a situation, the power electronic devices such as flexible alternating-current transmission system (FACTS) and custom power devices (DVR) which are used in transmission and distribution control, respectively, should be developed [4], [5], [6]. The impact of transient parameters in majority of transmission lines problems such as sag (voltage dip), swell (over voltage) and interruption, are also considerable [1]. To mitigate the mentioned power quality problems, the utilization of FACTS devices such as power flow controller (UPFC) and synchronous static compensator (STAT-COM) can be helpful [7], [8]. In [9], the distributed power flow controller (DPFC) is presented which has a similar configuration to UPFC structure. As shown in Fig. 1, the DPFC is composed of a single shunt converter and multiple independent series converters which is used to balance the line parameters, such as line impedance, transmission angle and bus voltage magnitude [9], [10]. To detect the voltage sags and determine the three single-phase reference voltages of DPFC, the SRF method is also proposed as a detection and determination method. The work in this paper is organized as follows: the DPFC operation principle is debated in Section II. In Section III, the control strategy of DPFC based on SRF method is proposed. The impact of DPFC in power quality enhancement is investigated in Section IV. Finally, the case study and its simulation results are analyzed in the last part of this work. II. DPFC STRUCTURE The basic issues in DPFC principle are DC-link elimination and using 3 rd -harmonic current to active power exchange. In the following subsections, the DPFC basic concepts are explained. A. Eliminate DC-Link and Power Exchange Within the DPFC, the transmission line is used as a connection between shunt converter output and AC port of series converters, instead of using DC-link for power exchange between converters. The method of power exchange in DPFC is based on power theory of non-sinusoidal components [9]. Non-sinusoidal voltage and current can be presented as the sum of sinusoidal components at different frequencies. It is the main result of Fourier analysis. The Copyright to IJAREEIE www.ijareeie.com 11227

product of voltage and current components provides the active power. Since the integral of some terms with different frequencies are zero, so the active power equation is as follow: p V i I i cos i, (1) i 1 Where V i and I i are the voltage and current at the i th harmonic frequency, respectively, and φi is the angle between the voltage and current at the same frequency. Equation. 1 expresses the active powers at different frequencies are independent from each others. Thus, the converter can absorb the active power in one frequency and generates output power in another frequency. Assume the DPFC is located in transmission line of a two-bus system; therefore, the power supply generates the active power and the shunt converter absorbs it in fundamental frequency of current. Meanwhile, the third harmonic component is trapped in Y- transformer. Output terminal of the shunt converter injects the third harmonic current into the neutral of -Y transformer. Consequently, the harmonic current flows through the transmission line. This harmonic current controls the dc voltage of series capacitors. Fig. 2 illustrates how the active power is exchanged between the shunt and series converters in the DPFC. Fig. 1.The DPFC structure.. B. The DPFC Advantages Fig. 2. Active power exchange between DPFC converters. The DPFC in comparison with UPFC has some advantages, as follows: 1) High control capability. The DPFC can control all parameters of transmission network: line impedance, transmission angle and bus voltage magnitude. 2) High reliability. The series converters redundancy increases the DPFC reliability during converters operation [10]. It means, if one of series converters fails, the others can continue to work. 3) Low cost. The single-phase converters rating, in comparison with three-phase converters is very low. Furthermore, the series Copyright to IJAREEIE www.ijareeie.com 11228

converters, in this configuration, no need to any voltage isolation to connect in line. We can use the single turn transformers for series converters hanging. To explore the feasibility of the DPFC, a case study which is to use DPFC to replace UPFC of the Korea electric power corporation (KEPCO) is investigated. To achieve the same control capability as the UPFC, the DPFC construction requires less material [9]. III. DPFC CONTROL BASED ON SRF METHOD The DPFC has three control strategies: central controller, series control and shunt control, as shown in Fig. 3. A. Central Control This controller manages all the series and shunt controllers and sends reference signals to both of them. B. Series Control Each single-phase converter has its own series control through the line. This controller inputs are series capacitor voltages, line current and series voltage reference in dq-frame. Any series controller has one low-pass and one 3rd-pass filter to create fundamental and third harmonic current respectively. Two single-phase phase lock loop (PLL) are used to take frequency and phase information from network [11]. The simulated diagram of series controller is shown in Fig. 4 C. Shunt Control The shunt converter includes a three-phase converter which is back-to-back connected to a single-phase converter Fig.3.DPFC Control Structure. Fig. 4. The series control structure. Copyright to IJAREEIE www.ijareeie.com 11229

Fig. 5. The shunt control configuration: (a) for fundamental frequency (b) for third-harmonic frequency The three-phase converter absorbs active power from grid at fundamental frequency and controls the dc voltage of capacitor between this converter and single-phase one. The shunt control structure block diagram is shown in Fig. 5. D. Proposed Detection and Determination Methods To detect the voltage sags and determine the three single phase reference voltages of DPFC, the SRF method is introduced as a detection and determination method. The line-to-neutral voltages of grid in the pre-sag state are convicted from abc coordinate system to SRF (dq0) as the first step of this method. Then, the dq0 values of actual and reference line-neutral grid voltages are compared which the existence of the difference between them is representation of voltage sag and considered as the dq0 values of DPFC desired injected voltages. V ref V dpfc,d grid ref V (2),d grid,d Fig.6.simulated model of the DPFC Copyright to IJAREEIE www.ijareeie.com 11230

IV. IV. POWER QUALITY ENHANCEMENT V dpfc ref,q V grid ref,q V grid,q, (3) The reference dq- component of DPFC desired injected voltages in the SRF, respectively. This modeling has been developed using Mat lab/simulink environment as shown in Fig. 6. The system is simulated with a three-phase source connected to a non-linear load. The simulation parameters are listed in Table 1. The supply is connected to load through the parallel transmission lines including the transmission line 1 and 2. The parallel transmission lines have same length. The DPFC is incorporated in transmission line 2. For analyzing dynamic performance, the inductive and capacitive loads are connected. The fault should be connected near the load to receive transient analysis. The shunt three-phase converter is connected to the transmission line 2 in parallel through a Y- three-phase transformer, and series converters are distributed through this line. V. SIMULATION RESULTS The case study, considering sag/swell condition is implemented in single machine infinite bus system and analyzed results are as follows. To analyze voltage dip, a three-phase fault near the system load, as shown in Fig. 6 is created. The time duration for this fault is 0.5 seconds (500-1000 ms). The three-phase fault causes observable voltage sag during this time, as shown in Fig. 7. The voltage sag value is about 0.5 per unit. The DPFC can compensate the load voltage sag effectively. The voltage sag mitigation with DPFC is shown in Fig. 8. After creating three-phase fault, Fig. 9 depicts the load current swell around 1.1 per unit. The fault time duration is 0.5 seconds. In this case, after implementation of the DPFC, the load current magnitude is comparatively come down. The current swell mitigation for this case can be observed from Fig. 10. The load voltage harmonic analysis, using fast Fourier transform (FFT) of power GUI window by Simulink, as shown in Fig. 11. It can be seen, after DPFC implementation in system, the odd harmonics are reduced within acceptable limits and total harmonic distortion (THD) of load voltage is minimized. Fig. 7. Three-phase load voltage sag waveform. Fig. 8. Mitigation of three-phase load voltage sag with DPFC. Copyright to IJAREEIE www.ijareeie.com 11231

Fig. 9. Three-phase load current swell waveform. Fig. 10. Mitigation of load current swell with DPFC. Fig. 11. The load voltage THD. VI. CONCLUSION The power quality enhancement of the power transmission systems is an vital issue in power industry. In his study, the application of DPFC as a new FACTS device, in the voltage sag and swell mitigation of a system composed of a threephase source connected to a non-linear load through the parallel transmission lines is simulated in Matlab/Simulink environment. The voltage dip is analyzed by implementing a three-phase fault close to the system load. To detect the voltage sags and determine the three single phase reference voltages of DPFC, the SRF method is used as a detection and determination method. The obtained simulation results show the effectiveness of DPFC in power quality enhancement, especially in sag and swell mitigation. Copyright to IJAREEIE www.ijareeie.com 11232

TABLE I : THE SIMULATED SYSTEM PARAMETERS. Parameters Three phase source Rated voltage Rated power/frequency values 230 [kv] 100[mW]/60[HZ] X/R 3 Short circuit capacity Transmission line Resistance Inductance/Capacitance reactance Length of transmission line 11000[MW] 0.012 [p.u./km] 0.12/0.12[p.u./km] 100 [km] REFERENCES 1. J. Faiz, G. H. Shahgholian, and M. Torabian, Design and simulation of UPFC or enhancement of power quality in transmission lines, IEEE International Conference on Power System Technology, vol. 24, no. 4, 2010. 2. E. Emanuel and J. A. McNeill, Electric power quality, Annu. Rev. Energy Environ, 1997. 3. N. R. Patne and K. L. Thakre Factor affecting characteristics of voltage sag due to fault in the power system, Serbian Journal of Electrical engineering. vol. 5, no.1, 2008. 4. J. R. Enslin, Unified approach to power quality mitigation, in Proc. IEEE Int. Symp. Industrial Electronics (ISIE 98), vol. 1, 1998. 5. B. Singh, K. Al-Haddad, and A. Chandra, A review of active filters for power quality improvement, IEEE Trans. Ind. Electron. vol. 46, no. 5, pp. 960 971, 1999. 6. M. A. Hannan and A. Mohamed, member IEEE, PSCAD/EMTDC simulation of unified series- shunt compensator for power quality improvement, IEEE Transactions on Power Delivery, vol. 20, no. 2, 2005. 7. L. Olimpo and E. Acha, Modeling and analysis of custom power systems by PSCAD/EMTDC, IEEE Trans. Power Delivery, vol. 17, no.1, pp. 266 272, 2002. 8. P. Pohjanheimo and E. Lakervi, Steady state modeling of custom power components in power distribution networks, in Proc. IEEE Power Engineering Society Winter Meeting, vol. 4, Jan, pp. 2949 2954, 2000. BIOGRAPHY. P. Rajasekhar was born in 1986. He received B.Tech in Electrical and Electronics Engineering from JNTU, Hyderabad, AP in 2008. He received M.Tech in Electrical Power Engineering from JNTU Ananthapur, AP in2011. He is working as Assistant Professor in BITIT, Hindupur, AP. His research interests include Power Electronics Drives and Power Engineering application CH.Narayana he received the B.Tech (Electrical and Electronics Engineering) degree from the S.V. University, Tirupathi in 2011 and pursuing the M.Tech (Electrical power system) from Jawaharlal Nehru Technological University, Anantapur. His area of interest in the field of power systems and Electric Drives. Copyright to IJAREEIE www.ijareeie.com 11233