A Multilevel Diode Clamped SVPWM Based Interline Dynamic Voltage Restorer with Sag & Swell Limiting Function

Similar documents
Simulation of Interline Dynamic Voltage Restorer for Sag/Swell Compensation and Power factor Improvement in Hybrid Electric System

IMPROVING THE COMPENSATION CAPACITY OF INTERLINE DYNAMIC VOLTAGE RESTORER

Comparative Study of Sag & Swell Mitigation by a Novel Multi Level DVR with Wavelets

INTERLINE UNIFIED POWER QUALITY CONDITIONER: DESIGN AND SIMULATION

Sag/Swell Compensation and Displacement Factor Improvement using IDVR in Distribution Network

Mitigating Voltage Sag Using Dynamic Voltage Restorer

COMPENSATION OF VOLTAGE SAG USING LEVEL SHIFTED CARRIER PULSE WIDTH MODULATED ASYMMETRIC CASCADED MLI BASED DVR SYSTEM G.Boobalan 1 and N.

Power Quality Improvement of Unified Power Quality Conditioner Using Reference Signal Generation Method

Power Quality Improvement by DVR

Simulation of Multi Converter Unified Power Quality Conditioner for Two Feeder Distribution System

Improvement of Power Quality Using a Hybrid Interline UPQC

Multi level DVR with Energy Storage System for Power Quality Improvement

Voltage Quality Enhancement in an Isolated Power System through Series Compensator

GRID CONNECTED HYBRID SYSTEM WITH SEPIC CONVERTER AND INVERTER FOR POWER QUALITY COMPENSATION

Kalman Filter Based Unified Power Quality Conditioner for Output Regulation

Development and Simulation of Dynamic Voltage Restorer for Voltage SAG Mitigation using Matrix Converter

Power-Quality Improvement with a Voltage-Controlled DSTATCOM

Design Strategy for Optimum Rating Selection of Interline D-STATCOM

Design of Interline Dynamic Voltage Restorer for Voltage Sag Compensation

Design of Dynamic Voltage Restorer for three phase network as steady state device in the Distribution System

VOLTAGE SAG COMPENSATION USING UNIFIED POWER FLOWER CONTROLLER IN MV POWER SYSTEM USING FUZZY CONTROLLER

ISSN Vol.07,Issue.21, December-2015, Pages:

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

Power Quality Improvement in Fourteen Bus System using UPQC

A Novel Cascaded Multilevel Inverter Using A Single DC Source

Power Quality Improvement by Simultaneous Controlling of Active and Reactive Powers in UPQC-S

Power Quality Improvement By Using DSTATCOM Controller

Phase Shift Modulation of a Single Dc Source Cascaded H-Bridge Multilevel Inverter for Capacitor Voltage Regulation with Equal Power Distribution

B.Tech Academic Projects EEE (Simulation)

Multifunctional Dynamic Voltage Restorer Using Matrix Converter Resmi. S, Reshmi. V, Joffie Jacob Amal Jyothi College of Engineering, Kanjirappally

Voltage Sag and Mitigation Using Dynamic Voltage Restorer (DVR) System

Compensation for Voltage and Current in Multifeeder System Using MC-UPQC

A NOVEL APPROACH TO ENHANCE THE POWER QUALITY USING CMLI BASED CUSTOM POWER DEVICES

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

Five Level Output Generation for Hybrid Neutral Point Clamped Inverter using Sampled Amplitude Space Vector PWM

Interline Power Quality Conditioner for Power Quality Improvement

Z-SOURCE INVERTER BASED DVR FOR VOLTAGE SAG/SWELL MITIGATION

A Versatile Control Scheme for UPQC for Power Quality Improvement using fuzzy controller

Reduction of Voltage Imbalance in a Two Feeder Distribution System Using Iupqc

A Modified Control Method For A Dual Unified Power Quality Conditioner

Effective Algorithm for Reducing DC Link Neutral Point Voltage and Total Harmonic Distortion for Five Level Inverter

Simulation and Implementation of DVR for Voltage Sag Compensation

Harmonic Reduction in Five Level Inverter Based Dynamic Voltage Restorer

Dynamic Modeling and Simulation of Unified Power Quality Conditioner

CONTROL OF VOLTAGE SAG/SWELL IN THREE PHASE DISTRIBUTION LINE

IJCSIET--International Journal of Computer Science information and Engg., Technologies ISSN

SIMULATION OF A SPACE VECTOR PWM CONTROLLER FOR A THREE-LEVEL VOLTAGE-FED INVERTER MOTOR DRIVE

LOAD REACTIVE POWER COMPENSATION BY USING SERIES INVERTER OF UPQC

Manjeet Baniwal 1, U.Venkata Reddy 2, Gaurav Kumar Jha 3

FUZZY LOGIC CONTROL BASED DYNAMIC VOLTAGE RESTORER FOR POWER QUALITY IMPROVEMENT IN DISTRIBUTION SYSTEM

Transformerless Grid-Connected Inverters for Photovoltaic Modules: A Review

SUPER CONDUCTING MAGNETIC ENERGY SYSTEM WITH DVR FOR VOLTAGE QUALITY IMPROVEMENT USING PSO BASED SIMPLE ABC FRAME THEORY

UPQC for Improvement Power Quality.

Mitigation of Voltage Sag/Swell Using UPQC

Design and Control of Interline Unified Power Quality Conditioner for Power Quality Disturbances

Design Of An Integrated Dynamic Voltage Restorer-Ultracapacitor For Improving The Power Quality Of The Distribution Grid

Downloaded from

Design and Simulation of DVR Used For Voltage Sag Mitigation at Distribution Side

SUPERCONDUCTING MAGNETIC ENERGY

A Voltage Controlled D-STATCOM for Power Quality Improvement with DVR

SIMULATION AND COMPARISON OF SPWM AND SVPWM CONTROL FOR TWO LEVEL UPQC

Ripple Reduction Using Seven-Level Shunt Active Power Filter for High-Power Drives

Study & Comparison of Various Topologies of Dynamic Voltage Restorer & Its type: a Review

Simulation And Comparison Of Space Vector Pulse Width Modulation For Three Phase Voltage Source Inverter

IJSTE - International Journal of Science Technology & Engineering Volume 2 Issue 12 June 2016 ISSN (online): X

Power Quality Improvement Using Cascaded Multilevel Statcom with Dc Voltage Control

Power Quality Improvement By Using CHB Inverter Based DVR

Analysis & Function of Unified Power Quality Conditioner for Power Quality Improvement of Distributed Network

Voltage Sags in Distribution Systems with Induction Motor Loads Fed by Power Converters and Voltage Mitigation using DVR and D-STATCOM

SINGLE PHASE THIRTY ONE LEVEL INVERTER USING EIGHT SWITCHES TOWARDS THD REDUCTION

Design and Simulation of Dynamic Voltage Restorer (DVR) Using Sinusoidal Pulse Width Modulation (SPWM)

Reduction of Power Electronic Devices with a New Basic Unit for a Cascaded Multilevel Inverter fed Induction Motor

Performance of DVR under various Fault conditions in Electrical Distribution System

Mitigation of Fault in the Distribution System by using Flexible Distributed Static Compensator (FD-STATCOM)

Mitigation of Voltage Sag/Swell by Using Battery Energy Storage DVR for Induction Motor Drive Applications

Sampled Reference Frame Algorithm Based on Space Vector Pulse Width Modulation for Five Level Cascaded H-Bridge Inverter

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

ISSN Vol.03,Issue.11, December-2015, Pages:

Svpwm Technique to Eliminate Harmonics and Power Factor Improvement Using Hybrid Power Filter and By Using Dsp Tms 320lf2407

Modified Three-Phase Four-Wire UPQC Topology with Reduced DC-Link Voltage Rating

Compare Stability Management in Power System Using 48- Pulse Inverter, D-STATCOM and Space Vector Modulation Based STATCOM

Simulation and Comparison of DVR and DSTATCOM Used For Voltage Sag Mitigation at Distribution Side

Speed Control of Induction Motor using Multilevel Inverter

INTERNATIONAL JOURNAL OF PROFESSIONAL ENGINEERING STUDIES Volume V /Issue 4 /AUG 2015

Multilevel Inverter Based Statcom For Power System Load Balancing System

Bhavin Gondaliya 1st Head, Electrical Engineering Department Dr. Subhash Technical Campus, Junagadh, Gujarat (India)

PSPWM Control Strategy and SRF Method of Cascaded H-Bridge MLI based DSTATCOM for Enhancement of Power Quality

Analysis of Voltage Source Inverters using Space Vector PWM for Induction Motor Drive

ANALYSIS OF SYNCHRONOUS-REFERENCE-FRAME-BASED CONTROL METHOD FOR UPQC UNDER UNBALANCED AND DISTORTED LOAD CONDITIONS Salava Nagaraju* 1

Design Requirements for a Dynamic Voltage Restorer for Voltage Sags Mitigation in Low Voltage Distribution System

Multiconverter Unified Power-Quality Conditioning System: MC-UPQC T.Charan Singh, L.Kishore, T.Sripal Reddy

COMPARATIVE STUDY ON CARRIER OVERLAPPING PWM STRATEGIES FOR THREE PHASE FIVE LEVEL DIODE CLAMPED AND CASCADED INVERTERS

Improvement of Voltage Profile using D- STATCOM Simulation under sag and swell condition

MITIGATION OF VOLTAGE SAGS/SWELLS USING DYNAMIC VOLTAGE RESTORER (DVR)

Power Quality Improvement using Hysteresis Voltage Control of DVR

Literature Survey: Multilevel Voltage Source Inverter With Optimized Convention Of Bidirectional Switches

ISSN Vol.07,Issue.11, August-2015, Pages:

Design of Hybrid Active Filter for Power Quality Improvement of Electrical Distribution System Using Fuzzy Logic Controller

Unified Power Quality Conditioner (UPQC) in Alleviation of Power Quality Issues

Mitigation of voltage sag by using AC-AC PWM converter Shalini Bajpai Jabalpur Engineering College, M.P., India

Transcription:

International Journal of Electronics Engineering Research. ISSN 0975-6450 Volume 9, Number 5 (2017) pp. 751-760 Research India Publications http://www.ripublication.com A Multilevel Diode Clamped SVPWM Based Interline Dynamic Voltage Restorer with Sag & Swell Limiting Function G. Devadasu #1, Dr. M. Sushama *2 # Department of EEE, CMR College of Engineering & Technology, * Department of EEE, JNTUH University Hyderabad, TS, India. Abstract An interline dynamic voltage restorer (IDVR) is a new device for sag mitigation which is made of several dynamic voltage restorers (DVRs) with a common dc link, where each SVPWM based DVR is connected in series with a distribution feeder. During the sag period, active power can be transferred from a feeder to another one and voltage sags & swell with long durations can be mitigated. IDVR compensation capacity, however, depends greatly on the load power factor, and a higher load power factor causes lower performance of IDVR. To overcome this limitation, a new idea is presented in this paper which enables reducing the load power factor under sag & swell conditions and, therefore, the compensation capacity is increased. The proposed IDVR employs diode clamped multilevel converters with SVPWM to inject ac voltage with lower total harmonic distortion and eliminates the necessity to low-frequency isolation transformers in one side. Keywords: Sag, swell, Mitigation, fuzzy logic, DVR,IDVR and SVPWM I. INTRODUCTION The American "sag" and the British "dip" are both names for a decrease in voltage to between 10 and 90% of nominal voltage for one-half cycle to one minute Sags account for the vast majority of power problems experienced by end users. They can be generated both internally and externally from an end users facility.

752 G. Devadasu and Dr. M. Sushama External causes of sags primarily come from the utility transmission and distribution network. Sags coming from the utility have a variety of cause including lightning, animal and human activity, and normal and abnormal utility equipment operation. Sags generated on the transmission or distribution system can travel hundreds of miles thereby affecting thousands of customers during a single event. Sometimes externally caused sags can be generated by other customers nearby. The starting of large electrical loads or switching off shunt capacitor banks can generate a sag large enough to affect a local area. If the end user is already subject to chronic under voltage, then even a relatively small amplitude sag can have detrimental effects. Sags caused internally to an end user's facility are typically generated by the starting of large electrical loads such as motors or magnets. The large inrush of current required to starts these types of loads depresses the voltage level available to other equipment that share the same electrical system. As with externally caused sags, ones generated internally will be magnified by chronic under voltage. A swell is the opposite of sag - an increase in voltage above 110% of nominal for onehalf cycle to one minute. Although swells occur infrequently when compared to sags, they can cause equipment malfunction and premature wear. Swells can be caused by shutting off loads or switching capacitor banks on. II SPACE VECTOR PULSE WIDTH MODULATION A different approach to SPWM is based on the space vector representation of voltages in the d, q plane. The d, q components are found by Park transform, where the total power, as well as the impedance, remains unchanged. Fig: space vector shows 8 space vectors in according to 8 switching positions of inverter, V* is the phase-to-center voltage which is obtained by proper selection of adjacent vectors V1 and V2. Fig 1: Inverter output voltage space vector

A Multilevel Diode Clamped SVPWM Based Interline Dynamic Voltage 753 Fig 2 : Determination of Switching times The reference space vector V* is given by Equation (1), where T1, T2 are the intervals of application of vector V1 and V2 respectively, and zero vectors V0 and V7 are selected for T0. V* Tz = V1 *T1 + V2 *T2 + V0 *(T0/2) + V7 *(T0/2).(4) Fig. below shows that the inverter switching state for the period T1 for vector V1 and for vector V2, resulting switching patterns of each phase of inverter are shown in Fig. pulse pattern of space vector PWM. Fig 3 : Inverter switching state for (a)v1, (b) V2 Fig 4: Pulse pattern of Space vector PWM

754 G. Devadasu and Dr. M. Sushama COMPARISON In above Fig:- comparison, U is the phase to- center voltage containing the triple order harmonics that are generated by space vector PWM, and U1 is the sinusoidal reference voltage. But the triple order harmonics are not appeared in the phase-tophase voltage as well. This leads to the higher modulation index compared to the SPWM. COMPARISON OF SPWM AND SPACE VECTOR PWM As mentioned above, SPWM only reaches to 78 percent of square wave operation, but the amplitude of maximum possible voltage is 90 percent of square-wave in the case of space vector PWM. The maximum phase-to-center voltage by sinusoidal and space vector Fig 5 : Space vector PWM matlab module

A Multilevel Diode Clamped SVPWM Based Interline Dynamic Voltage 755 PWM are respectively Vmax = Vdc/2 : Sinusoidal PWM Vmax = Vdc/ 3 : Space Vector PWM Where, Vdc is DC-Link voltage. This means that Space Vector PWM can produce about 15 percent higher than Sinusoidal PWM in output voltage. SVM PWM TECHNIQUE: The Pulse Width modulation technique permits to obtain three phase system voltages, which can be applied to the controlled output. Space Vector Modulation (SVM) principle differs from other PWM processes in the fact that all three drive signals for the inverter will be created simultaneously. The implementation of SVM process in digital systems necessitates less operation time and also less program memory. The SVM algorithm is based on the principle of the space vector u*, which describes all three output voltages ua, ub and uc :

756 G. Devadasu and Dr. M. Sushama u* = 2/3. ( ua + a. ub + a2. uc ) (5) Where a = -1/2 + j. v3/2 We can distinguish six sectors limited by eight discrete vectors u0 u7 (fig:- inverter output voltage space vector), which correspond to the 23 = 8 possible switching states of the power switches of the inverter. III SPACE VECTOR MODULATION The amplitude of u0 and u7 equals 0. The other vectors u1 u6 have the same amplitude and are 60 degrees shifted. By varying the relative on-switching time Tc of the different vectors, the space vector u* and also the output voltages ua, ub and uc can be varied and is defined as: ua = Re ( u* ) ub = Re ( u*. a-1) uc = Re ( u*. a-2) (6) During a switching period Tc and considering for example the first sector, the vectors u0, u1 and u2 will be switched on alternatively. Definition of the Space vector Depending on the switching times t0, t1 and t2 the space vector u* is defined as: u* = 1/Tc. ( t0. u0 + t1. u1 + t2. u2 ) u* = t0. u0 + t1. u1 + t2. u2 u* = t1. u1 + t2. u2.. (7)

A Multilevel Diode Clamped SVPWM Based Interline Dynamic Voltage 757 Where t0 + t1 + t2 = Tc and t0 + t1 + t2 = 1 t0, t1 and t2 are the relative values of the on switching times. They are defined as: t1 = m. cos (a + p/6) t2 = m. sin a t0 = 1 - t1 - t2 Their values are implemented in a table for a modulation factor m = 1. Then it will be easy to calculate the space vector u* and the output voltages ua, ub and uc. The voltage vector u* can be provided directly by the optimal vector control laws w1, vsa and vsb. In order to generate the phase voltages ua, ub and uc corresponding to the desired voltage vector u* the following SVM strategy is proposed. Device connected Power factor T.H.D Compensated voltage Without compensator 0.62 25.5 0v 0v With 2 level DVR 0.69 10.2 264v 2.3A With 3 level DVR 0.72 6.5 464v 2.3A With 5 level DVR 0.74 4.6 764v 2.3A With 2 level STATCOM 0.69 17.8 264v 6.5A With 3 level STATCOM 0.72 10.9 264v 7.2A With 5 level STATCOM 0.76 6.1 264v 10.3A With level MC-UPQC 0.83 2.2 864v 15. 3A Compensated current

758 G. Devadasu and Dr. M. Sushama IV SIMULATION MODEL & RESULTS Fig 6: Multi level SVPWM based Compensator Fig 7: Multi level voltages Fig 8: Current at the load

A Multilevel Diode Clamped SVPWM Based Interline Dynamic Voltage 759 Fig 9: Analysis by wavelets V CONCLUSION In this paper, a new configuration has been proposed which not only improves the compensation capacity of the IDVR at high power factors, but also increases the performance of the compensator to mitigate deep sags at fairly moderate power factors. These advantages were achieved by decreasing the load power factor during the sag condition. In this technique, the source voltages are sensed continuously and when the voltage sag is detected, the shunt reactance s are switched into the circuit and decrease the load power factors to improve IDVR performance. Finally, the simulation and practical results on the CHB-based IDVR confirmed the effectiveness of the proposed configuration and control scheme. REFERENCES [1] P. F. Comesana, D. F. Freijedo, J. D. Gandoy, O. Lopez, A. G. Yepes, and J. Malvar, Mitigation of voltage sags, imbalances and harmonics in sensitive industrial loads by means of a series power line conditioner, Elect. Power Syst. Res., vol. 84, pp. 20 30, 2012. [2] A. Felce, S. A. C. A. Inelectra, G. Matas, and Y. Da Silva, Voltage sag analysis and solution for an industrial plant with embedded induction motors, in Proc. IEEE Ind. Appl. Soc. Conf. Annu. Meeting., 2004, vol. 4, pp. 2573 2578.

760 G. Devadasu and Dr. M. Sushama [3] A. Sannino, M. G. Miller, and M. H. J. Bollen, Overview of voltage sag mitigation, in Proc. IEEE Power Eng. Soc. Winter Meeting, 2000, vol. 4, pp. 2872 2878. [4] E. Babaei, M. F. Kangarlu, and M. Sabahi, Mitigation of voltage disturbances using dynamic voltage restorer based on direct converters, IEEE Trans. Power Del., vol. 25, no. 4, pp. 2676 2683, Oct. 2010. [5] H. K. Al-Hadidi, A. M. Gole, and D. A. Jacobson, A novel configuration for a cascade inverter-based dynamic voltage restorer with reduced energy storage requirements, IEEE Trans. Power Del., vol. 23, no. 2, pp. 881 888, Apr. 2008. [6] D. M. Vilathgamuwa, A. A. D. R. Perera, and S. S. Choi, Voltage sag compensation with energy optimized dynamic voltage restorer, IEEE Trans. Power Del., vol. 18, no. 3, pp. 928 936, Jul. 2003. [7] N. A. Samra, C. Neft, A. Sundaram, and W. Malcolm, The distribution system dynamic voltage restorer and its applications at industrial facilities with sensitive loads, presented at the Power Convers. Intell. Motion Power Qual., Long Beach, CA, USA, Sep. 1995.