Battery Impedance Measurement

Similar documents
Power Supply Rejection Ratio Measurement

Power Supply Rejection Ratio Measurement

Power Supply Rejection Ratio Measurement

DC Biased Impedance Measurement

Solar Cell Impedance Measurement using the Bode 100

Invasive and Non-Invasive Stability Measurements

Making Invasive and Non-Invasive Stability Measurements

S-Parameter Measurements with the Bode 100

Power Supply Rejection Ratio Measurement

DC/DC Converter Stability Measurement

Equivalent Circuit Determination of Quartz Crystals

DC/DC Converter Stability Measurement

Low Value Impedance Measurement using the Voltage / Current Method

Measuring Impedance with the Bode 100. OMICRON Lab Webinar Nov. 2014

Opamp stability using non-invasive methods

Measure Low Value Impedance Current Shunt Impedance

Measurement of the equivalent circuit of quartz crystals

Documentation. Voltage Regulator Test Standard. Test Platform for Voltage Regulator and LDO Testing

DC/DC Converter Stability Measurement

DC Biased Impedance Measurements MOSFET

Summary. Output bench. Frequency Response Signal to Noise Ratio Crosstalk, One Channel Undriven Interchannel Phase Input bench.

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc.

Signal Injectors. Documentation. Version 1.00, October, Picotest Corp. All Rights Reserved.

Measuring Power Line Impedance

Lab 9 Frequency Domain

Exclusive Technology Feature. An Accurate Method For Measuring Capacitor ESL. ISSUE: April by Steve Sandler, Picotest, Phoenix, Ariz.

User manual. / verzió 1.0 /

Audio Amplifier Frequency Response

Passive Component Analysis. OMICRON Lab Webinar Nov. 2015

Input Impedance Measurements for Stable Input-Filter Design

Documentation. Voltage Regulator Test Standard. Test Platform for Voltage Regulator and LDO Testing

EENG-201 Experiment # 4: Function Generator, Oscilloscope

MEASURING HUM MODULATION USING MATRIX MODEL HD-500 HUM DEMODULATOR

Preamplifier Options for Reducing Cable-Braid Loop Error

3.2 Measuring Frequency Response Of Low-Pass Filter :

Equivalent Circuit Determination of Quartz Crystals

Non Invasive Assessment of Voltage Regulator Phase Margin without Access to the Control Loop

TT7000R4. DS Instruments. D text. RF Power Meter, Signal Generator, Frequency Counter. -Key Features-

Test No. 2. Advanced Scope Measurements. History. University of Applied Sciences Hamburg. Last chance!! EEL2 No 2

Test No. 1. Introduction to Scope Measurements. Report History. University of Applied Sciences Hamburg. Last chance!! EEL2 No 1

DEPARTMENT OF INFORMATION ENGINEERING. Test No. 1. Introduction to Scope Measurements. 1. Correction. Term Correction. Term...

When you have completed this exercise, you will be able to determine the frequency response of an

Measuring PCB, Cable and Interconnect Impedance, Dielectric Constants, Velocity Factor, and Lengths

EE4902 C Lab 7

B. Equipment. Advanced Lab

Arbitrary/Function Waveform Generators 4075B Series

Transfer Function (TRF)

VVM measurement with E5061B for replacing 8508A vector voltmeter. May 2013 Agilent Technologies

How to Measure LDO PSRR

CONTENTS. User Manual

Quick Site Testing with the 8800SX

TA MHz ±700 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

Handheld 3.3GHz Spectrum Analyzer

ECE 4670 Spring 2014 Lab 1 Linear System Characteristics

Review: The MFJ-225 Graphical Antenna Analyzer Phil Salas AD5X

ECE4902 Lab 5 Simulation. Simulation. Export data for use in other software tools (e.g. MATLAB or excel) to compare measured data with simulation

ECE3204 D2015 Lab 1. See suggested breadboard configuration on following page!

STATION NUMBER: LAB SECTION: Filters. LAB 6: Filters ELECTRICAL ENGINEERING 43/100 INTRODUCTION TO MICROELECTRONIC CIRCUITS

Electronics EECE2412 Spring 2016 Exam #1

Evaluating DC-DC Converters and PDN with the E5061B LF-RF Network Analyzer. Application Note

The 2-Port Shunt-Through Measurement and the Inherent Ground Loop

Sirindhorn International Institute of Technology Thammasat University

SAMPLE: EXPERIMENT 2 Series RLC Circuit / Bode Plot

PSM Soft. Features and Functions January PC Software Guide. Getting connected and Communication

Linear Motor Test Sequence

EIS Measurement of a Very Low Impedance Lithium Ion Battery

Compact VNA - TR1300/1

Experiment 8 Frequency Response

Vector Network Analyzers (VERY) Basics. Tom Powers USPAS SRF Testing Course 19 Jan. 2014

Harmonic Comb Injector

Oscilloscope and Function Generators

ECE4902 C Lab 7

Agilent E2695A SMA Probe Head for InfiniiMax 1130 Series Active Oscilloscope Probes. User s Guide

RF Characterization Report

CAA-100A Cable & Antenna Analyzer + Spectrum Analyzer

Effectively Using the EM 6992 Near Field Probe Kit to Troubleshoot EMI Issues

LAB 8: Activity P52: LRC Circuit

Specification for Conducted Emission Test

Understanding the Precision Antenna, Cable, and Power Measurements on the 3550 Radio Test System

Op-Amp Simulation Part II

Transformer modelling

Low_Pass_Filter_1st_Order -- Overview

Core Technology Group Application Note 6 AN-6

Glossary of VCO terms

Lithium-ion batteries are emerging as the de facto. battery.

CAA-100A Cable & Antenna Analyzer + Spectrum Analyzer

ML12561 Crystal Oscillator

11/19/2013 3:49 PM Page 1 of 26

University of New Hampshire InterOperability Laboratory Gigabit Ethernet Consortium

Rigol DG1022A Function / Arbitrary Waveform Generator

AV3672 Series Vector Network Analyzer

Specification RIGOL. 6 Specification

Migrating 4195A to E5061B LF-RF Network Analyzer. April 2010 Agilent Technologies

Agilent N9923A FieldFox RF Vector Network Analyzer 2 MHz to 4/6 GHz. Data Sheet

RF and Microwave Test and Design Roadshow 5 Locations across Australia and New Zealand

Bode 100. User Manual

PNA Family Microwave Network Analyzers (N522x/3x/4xB) CONFIGURATION GUIDE

Bode 100. User Manual. Smart Measurement Solutions

Controlling Input Ripple and Noise in Buck Converters

Model 865 RF / Ultra Low Noise Microwave Signal Generator

Transcription:

Page 1 of 8 Using the Bode 100 and the Picotest J2111A Current Injector

Page 2 of 8 Table of Contents 1 Executive Summary...3 2 Measurement Task...3 3 Measurement Setup & Results...4 3.1.1 Device Setup...5 3.1.2 Calibration...6 3.1.3 Measurement...7 4 Conclusion...8

Page 3 of 8 1 Executive Summary Battery impedance includes information about the internal state of a battery. The impedance depends on many factors such as the chemical properties and mechanical design of the battery. Measuring the battery impedance over frequency helps to identify the characteristics of the battery. The Bode 100 in conjunction with the Picotest J2111A Current Injector offers an easy way to measure the impedance of a battery in the frequency range from 1 Hz to 10 MHz. This application note shows the connection setup and the device settings of the Bode 100 necessary to perform the impedance measurement. 2 Measurement Task The impedance of an alkaline 9V block is measured in the frequency range from 1 Hz to 10 MHz. After discharging the battery to a no load voltage of the impedance spectrum is measured again and compared to the measurement performed on the full charged battery. Furthermore, the impedance spectrum of a lithium ion battery is measured to demonstrate that even cells with low output resistance can be measured with the presented method.

Page 4 of 8 3 Measurement Setup & Results The impedance of a battery,, can be measured by loading the battery with an AC 1 current and measuring the resulting AC output voltage of the battery. Dividing the AC output voltage by the AC output current leads to the impedance of the battery. The output current of the battery is modulated by the J2111A current injector, driven by the output signal of the Bode 100. The output current is then measured by connecting CH1 of the Bode 100 to the current monitor output of the J2111A. The output voltage of the battery is measured directly using a 1:1 voltage probe connected to CH2. The connection setup is shown in the figure below: Figure 1: Connection Setup Note: The maximum allowed battery voltage with this setup is! 1 Alternating Current (sine-waveform)

Page 5 of 8 3.1.1 Device Setup Current Injector J2111A: The positive bias of the Current Injector must be switched on (+bias) as the Bode 100 output voltage does not have an offset. The positive bias provides a offset current, allowing the current injector to operate in class A mode. For the best performance, the output wires from the J2111A should be twisted or be coaxial. Bode 100: The battery impedance measurement can be performed directly with the Bode 100 using the external reference function. The Bode 100 is set up as follows: Measurement Mode: Start Frequency: Stop Frequency: Sweep Mode: Number of Points: Receiver Bandwidth: Attenuator 1 &2: Level: Frequency Sweep Mode 1 Hz 10 MHz Logarithmic 201 or more 100 Hz 0 db 0 dbm To switch on the external reference start the device configuration window and click on the external reference switch symbol: In addition, the input impedance of channel 1 must be set to 50Ω, while channel 2 need to remain in high impedance mode:

Page 6 of 8 Trace 1 settings: It is advisable to activate the Full Speed Mode to achieve a higher measurement speed since we are measuring over a low frequency range. 3.1.2 Calibration To remove the influence of the voltage probe, we recommended calibrating the setup. To do this the voltage probe at CH2 is connected to the current monitor output of the current injector and a THRU calibration is performed. CH2 CH1 Figure 2: Connection during THRU calibration

3.1.3 Measurement Bode 100 - Application Note For the measurement of the battery impedance, the battery under test is connected as shown in the picture below. Page 7 of 8 Figure 3: Measurement Setup Example First, we measure impedance of the fully charged battery. Starting a single sweep leads to the following impedance spectrum: 10 1 TR1 10 0 10-1 10 0 10 1 10 2 10 3 10 4 10 5 10 6 10 7 TR1: Mag(Gain) f/hz The Gain magnitude in this case equals the impedance magnitude in Ohm. At impedance shows a value of. the

Now the battery is discharged to a no load voltage of and a second sweep is performed. This results in a different impedance spectrum (see solid line in the graph below). 10 1 Page 8 of 8 TR1 10 0 10-1 The battery impedance at did increase to. The same measurement setup can be used to measure all types of batteries. As an example we measured the impedance of a, lithium ion cell. The impedance of this cell is shown in the graph below: 10 1 10 0 10 1 10 2 10 3 10 4 10 5 10 6 10 7 TR1: Mag(Gain) f/hz TR1(Memory): Mag(Gain) 10 0 TR1 10-1 10-2 10 0 10 1 10 2 10 3 10 4 10 5 10 6 10 7 TR1: Mag(Gain) At the lithium ion cell shows an impedance of which is much lower than the impedance of the alkaline battery. 4 Conclusion f/hz The Bode 100 in conjunction with the Picotest J2111A Current Injector offers a test set that enables simple and fast measurement of the battery impedance. The impedance of low and high impedance batteries can be evaluated over the frequency range from 1 Hz to 10 MHz.