Simple Sturdy Economical LABEL. Invest in Confidence. Weatherproof Quarter-turn Actuators EZ RANGE

Similar documents
Simple Sturdy Economical LABEL. Invest in Confidence. Weatherproof Multi-turn Actuators ET RANGE

Simple Sturdy Economical LABEL. Invest in Confidence. Weatherproof Quarter-turn Actuators EZ RANGE

Industrial actuation made easy

SERIES 70 ELECTRIC ACTUATORS THE HIGH PERFORMANCE COMPANY BRAY SERIES 70 ELECTRIC ACTUATORS

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

SERIES 70 ELECTRIC ACTUATORS

Electric Actuator. of innovated design. Introducing KIMAX CONTROLS INC. > Patented switch of manual & Motor operation. Clutchless manualoverride.

BERNARD CONTROLS ALWAYS BY YOUR SIDE. Invest in Confidence

BERNARD CONTROLS ALWAYS BY YOUR SIDE

AC 01.2 HART Technical data Actuator controls

Cover Page - Electric Actuators & Accessories. Standard & Optional Features. OM Actuator Standard Features. OM Actuator Optional Features

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B

Value Valves USA. Electric Actuator DOUBLE ACTING SPRING RETURN.

VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service

AC 01.2 Modbus TCP/IP

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

FC Series Signal Conditioners

FEATURES OPTIONAL FEATURES

LA-5000 SERIES LINEAR VALVE ACTUATORS

WE Series FEATURES OPTION CONFIGURATION STANDARD CONFIGURATION

E l e c t r i c A c t u a t o r s

Series 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

ELECTRIC ACTUATOR. Quarter turn(rotary type) - ZGQ Series

2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS

INTEGRAL+ Integrated control

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Invest in Confidence INTEGRAL+ Integrated control

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

Spring Return DuraDrive Proportional Actuator

Electric Actuator MULTI-TURN. ITM Series 0180 / 0450 / 0750 / 1800 / 3000

VALVCON V-SERIES ACTUATOR 115VAC AND 230VAC

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

To be automatically connected to the nearest North American Technical Sales Office:

Explosion proof rotary actuator - On/Off or programmable regulating actuator

S11 Adjustable Speed Drive Engineering Specification

AE SERIES ACTUATORS. Electric Actuators. Standard Voltages 110/240/380/480V 24VAC/24VDC. Modulating Capable. 100% Duty Cycle Models Fast Acting Models

AC/DC 24 V, 50/60 Hz. Functional data Variable Settings. DC V, max. 0.5 ma. End point DC V... 4 ma ma Non-variable

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

AE SERIES ACTUATORS 2016 EDITION. The Best Way To Automate Your Process. Modulating Capable. Extended Duty Cycle Models Fast Acting Models

Overview of types. Technical data

BFS / BFSM SERIES Installation & Maintenance Manual

Power consumption In operation At rest For wire sizing. Auxiliary switch NRF24A-SR-S2 NRF24A-SR-S2-O

1-phase AC current Voltages/frequencies Volt Volt 110, 115, , 230, 240 Hz Hz 60 50

Technical data V phase cut, input impedance 8.2 k Position feedback (measuring voltage U) DC V, max. 0.5 ma Start point DC

AWWA. Electric Actuators WE Series Weatherproof CSA Approved TYPE 4 & 4X ,900 in-lbs. torque C CONTROLS

1-phase AC current Voltages/frequencies Volt Volt 110, 115, , 230, 240 Hz Hz 60 50

Level Lance Model 5100

Series 70 24V and 120V Actuator 600 to 18,000 lb.-in.

Non-Spring Return DuraDrive Modulating Actuator

AMRI is ISO 9001 approved. Direct 1/4 turn electric actuators ACTELEC 3, 6, 12, 25, 50, 100 and 150 Output torques up to 1500 Nm

Series E2000P. Electrical linear actuator. Features SPECIFICATION. Valve Division Wörth am Main. A. Hock MSR- und Electronic Service GmbH

PEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

Valves with a difference. Electrical Actuators DVC INTERNATIONAL

Provides line voltage capable single Pole Double-Throw (SPDT) switch and 140Ω, 1KΩ, 2KΩ or 10KΩ feedback potentiometric.

E3 Adjustable Speed Drive Engineering Specification

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

Rotary gear motor series AG8...

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electric Motor Actuator with a built in Microcomputer

em4 local - Robust Specific characteristics Part number

CONTENTS XV300K GB r doc XV300K 2/13

1-phase AC current voltages/frequencies Volt Volt

Compact Electric Actuator. JFEW Series

COMPACT-LINE. Transmitter for ph-value

MODEL: MRP6. Final Control Elements

r ADDENDUM FOR REAR-OF-BOARD VERSION LFS - R

ADJUSTABLE SPEED DRIVES. AS1 Drive

Technical data. T2-SM230ASR en v Subject to changes / 3. Electrical data Nominal voltage AC

VALVCON V Series Actuator. 115VAC and 230VAC

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Technical data. Parameterisable damper actuator in the

AMC mA Positioner

BATCHMATE 1500 Batch Control Computer Technical Bulletin

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9207E 16-Channel, ±20 ma/±10 V, 24-Bit Analog Input Module

P2/3 LV Series On/Off/Jog / Proportional

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical Instructions Document No EA GQD June 23, OpenAir

Electric Motor Actuator with a built in Microcomputer

Power consumption In operation At rest For wire sizing. 150 s / C Sound power level Motor. Emergency setting function 61 db (A)

DISCONNECT SWITCHES. UL Listed CSA Certified

Process Control Calibration Made Easy with Agilent U1401A

Level Limit Switch nivotester FTL 325 P

Data sheet AWD3 3-phase, bidirectional energy meter for current converter metering with integrated S0-output Controls Division

Economic Style Electric Actuator. ITQ Series

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

Meduim Voltage Drives

F5 Feedback Unit. PMV F5 Feedback unit Product Information. A Flowserve Company

Power consumption In operation At rest For wire sizing

COMPACT-LINE. KOBO-pH Transmitter for ph-value Model APM-Z

Power consumption In operation At rest For wire sizing

VF-nC1 Adjustable Speed Drive Engineering Specification

OPERATING INSTRUCTIONS

Operating Instruction

02/11/2015

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

3TK28 Safety Relays. General data. 7/70 Siemens LV

T 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

Transcription:

Simple Sturdy Economical LABEL by Invest in Confidence EZ Weatherproof Quarter-turn Actuators EZ RANGE

2 Industrial actuation made easy BERNARD CONTROLS, inventor of the industrial compact quarter turn actuator, brings to its customers valve actuation solutions supported by decades of experience. Through discussions with users over the years, BERNARD CONTROLS has identified a demand for electric actuators that are both simple and sturdy. This demand is fulfilled with BERNARD CONTROLS FIRST BC labelled products. These actuators are well designed to work under moderate environmental & operational conditions. This range has been developed without compromising on quality, applying the unique expertise and feedback that are the cornerstones of BERNARD CONTROLS reputation. Thus, the FIRST BC label is the guarantee of actuator solutions with a total cost of ownership (TCO) among the lowest in their category, thanks to easy commissioning, proven reliability and a maintenance-free design. The EZ range products meet all criteria set by the FIRST BC label. 2014 - What s new? EZ LOGIC > Proven reliability with new integrated control Contents EZ range overview > 3 Tech Data - Performances > 8 Main features > 4 Tech Data - Dimensions > 9 Product specifications 6 >

3 EZ range overview SIMPLE, STURDY, ECONOMICAL Weatherproof Quarter-turn Actuators Adaptation to all quarter-turn valves: torque range from 45 to 10,000 Nm IP 67 / NEMA 4 Type of operation: On/Off Positioning Type of controls: Switches - EZ SWITCH for On-Off applications Integrated control - EZ LOGIC for On-Off or Positioning applications Compact, industrial design & Maintenance-free EZ SWITCH models EZ4 to EZ15 EZ25 to EZ60 EZ100 to EZ1000 EZ LOGIC models EZ4 to EZ15 EZ25 to EZ60 EZ100 to EZ1000 LABEL

4 Main features FIRST BC features FIRST BC labelled actuators are technically and economically optimized for their applications: > Moderate environmental constraints (IP67 / NEMA 4 and ambiant temperatures) > Moderate operational constraints (limited operating service) in order to address perfectly customers demand for simple and sturdy actuators. EZ actuators are: > Easy to install thanks to compactness, prewired product up to EZ60 for EZ SWITCH, non intrusive settings for EZ LOGIC models, > Easy to use with local display and signaling by LED on EZ LOGIC models (integrated control), > Easy to maintain as EZ are maintenance-free. EZ RANGE Easy commissioning Proven reliability Maintenance-free EZ SWITCH, for On-Off applications In this configuration, the control unit is designed by the customer and located in a remote cabinet. All information sent by the actuator sensors (travel limit, torque limit, thermal overload, position feedback,...) have to be processed by user s control logic. Power reversing starters are also housed in the remote cabinet. As far as travel limitation adjustment is concerned, BERNARD CONTROLS patented camblock system allows to quickly set the cams positions with a standard flat head screwdriver. Each single cam can be set independently from the others. The cams are automatically locked in their respective positions, once adjusted, and unaffected by vibrations. SWITCH control BC patented camblock

EZ LOGIC, for On-Off or Positioning applications EZ actuators are available with integrated control for extended control features and improved userfriendliness: > Easy commissioning: non-intrusive simplified settings thanks to keys and menus on local display, > Improved compactness of integrated electronics. > Local commands with 4 keys and signaling on a 7-segment display, with position displayed in percentage of opening, EZ LOGIC control board BERNARD CONTROLS proposes EZ LOGIC actuators for On-Off or Positioning applications which allow precise positioning (better than 2%) with position feedback. EZ LOGIC Motor EZ LOGIC Motor Local/Remote selection Local/Remote selection Power supply Power supply Open Close Analogic set-point Position feed-back Opened Closed Alarm Opened Closed Alarm Control station Control station EZ LOGIC integrated control On-Off version EZ LOGIC integrated control Positioning version EZ SWITCH actuators on Gas pumping station, South Africa

6 Product specifications General specifications General Gear design Design life Enclosures Motor technology Motor duty Temperature range Electrical connection Compliance with Directives & Standards Other certifications available EZ actuators include TENV* motor, gear case, emergency handwheel, travel limit control, torque control (except EZ4 to EZ15) and output drive with removable socket (plain socket in standard) Gears are mechanically self-locking and are lubricated for product lifetime EZ4 to EZ60: 20,000 cycles (On-Off) / 300,000 starts (Positioning) EZ100 to EZ1000: 10,000 cycles (On-Off) / 200,000 starts (Positioning) Tested according to EN15714-2 Class A & B Actuator housing in cast aluminum, cataphoresis & epoxy paint RAL2010 IP67 / NEMA 4 Totally-enclosed, 3-phase or 1-phase asynchronous motor, class F insulation with integrated thermal overload protection Totally-enclosed, 2-wire DC motor, class F insulation S4-25% motor duty rating to IEC 60034-1. 360 starts/hour in peak -20... +60 C / -4... +140 F Screw-type terminals for controls and power supply. Internal earth grounding post Actuators comply with: EC directives 2004/108/EC, 2006/95/EC and standards EN 61000-6-4, EN 61000-6-2, EN 60034-1 and EN 60529 CSA certified models for Canada and the United States Customs union certified models for Belarus, Kazakhstan and Russia * Totally Enclosed & Not Ventilated EZ SWITCH specifications Position indication Cable entries Anti-condensation Travel limit system Torque limiting system Remote position signal (option) Mechanical position indicator 2 x M20 sealed by caps Heater Camblock with 4 SPDT switches ; 250 VAC-16 A / 48 VDC-2,5 Amax. (resistive load) The torque limit switch gives a short duration contact. (except EZ4 to EZ15) 2 contacts as standard; SPDT; 250VAC-16A / 48 VDC-2,5A max. (resistive load) 1000 Ω potentiometer, 0.3 W - wiper current = max. 1mA. «TAM» position transmitter: 4-20 ma (12, 24 or 32VDC external supply for maximum acceptable load of 150, 750 or 1050 Ω) EZ LOGIC specifications Operation ON/OFF or POSITIONING with precision better than 2% Commissioning Non-intrusive settings Setting simplified by use of keys and menus on the display Cable entries 3 x M20 sealed by caps Anti-condensation Included in the power board Motor supply Solid state relay (all voltages) Protections Fuse protection: - At transformer primary: 1 fuse (not exchangeable) - At transformer secondary: 1 exchangeable fuse for each output. Automatic phase correction (for 3-phase supply) Reversal rotation protection Alarm signaling (local and remote) Protection against jamming Torque limiter (from EZ25 to EZ1000) Local command inhibition by local command

7 Remote command (ON/OFF) Analog input command (Positioning) Analog inputs Local command Position signaling relays Alarm relay Local signaling Analog position signal Max. output impedance Isolated by optocouplers by voltage: 10 to 250 V DC/AC by dry contacts (use EZ LOGIC internal DC supply) Minimum pulse duration: 100ms Time of rotational direction change: 300ms Input signal and position signal are fully isolated Standard input signal: 4-20 ma Input signal: 0-20 ma (on request) Input signal: 0-10 V (on request) In current: impedance of 160 Ω In voltage: impedance of 4000 Ω 4 keys : Local-remote selector/ Open / Close / Stop 1 latching relay* : valve opened 1 latching relay* : valve closed Switch configuration : Normally Opened Minimum current 10mA at 5V Max current: 5A at 250V AC or 5A at 30V DC max. (resistive load) *Latching relay allows keeping the position in case of power cut. SPDT switch Minimum current 10mA at 5V Max current: 5A at 250V AC or 5A at 30V DC max. (resistive load) Fault reported: Power supply or fuse alarm Loss a phase (with 3-phase supply) Motor overheating Maximum torque (from EZ25 to EZ1000) both direction Motor jamming Local command in local mode Loss of 4-20mA input signal (if configured with positioner and 4-20mA) Signaling by LED: - Setting (yellow LED): ON in set-up mode - Alarm (red LED): ON if a fault appear - Local (green LED): ON in Local mode - Opened (configurable red or green LED): ON when Opened position reached. Flashing during operation. - Closed (configurable green or red LED): ON when Closed position reached. Flashing during operation. Menu & position: on 7-segment display External DC supply (12 to 30VDC) Output signal: 4-20mA if input signal is 4-20mA Output signal: 0-20 ma if input signal is 0-20 ma Output signal: 0-20 ma (0-10V using a 500Ω external resistor) if input signal is 0-10V Maximum acceptable impedance of 750 Ohms with 24VDC (without 500Ω resistor) LABEL

BC GROUP BELGIUM BERNARD CONTROLS BENELUX BRUXELLES inquiry.belgium@bernardcontrols. com inquiry.holland@bernardcontrols.com Tel. +32 (0)2 343 41 22 CHINA BERNARD CONTROLS CHINA BEIJING inquiry.china@bernardcontrols.com Tel. +86 (0) 10 6789 2861 FRANCE BERNARD CONTROLS FRANCE GONESSE (PARIS) inquiry.france@bernardcontrols.com Tel. +33 1 34 07 71 00 GERMANY BERNARD CONTROLS DEUFRA TROISDORF inquiry.germany@bernardcontrols. com Tel. +49 22 41 98 340 ITALY BERNARD CONTROLS ITALIA MILANO inquiry.italy@bernardcontrols.com Tel. +39 02 931 85 233 KOREA BERNARD CONTROLS KOREA SEOUL inquiry.korea@bernardcontrols.com Tel. +82 2 553 69 57 MIDDLE-EAST BERNARD CONTROLS MIDDLE-EAST DUBAI - U.A.E. inquiry.middleeast@bernardcontrols. com Tel. +971 4 880 0660 CHENNAI - INDIA inquiry.india@bernardcontrols.com Tel. +0091 9566204444 RUSSIA BERNARD CONTROLS RUSSIA MOSCOW inquiry.russia@bernardcontrols.com Tel. +7 916 911 28 42 Tel. +7 985 923 84 13 SINGAPORE BERNARD CONTROLS SINGAPORE SINGAPORE inquiry.singapore@bernardcontrols. com Tel. +65 65 654 227 SPAIN BERNARD CONTROLS SPAIN MADRID inquiry.spain@bernardcontrols.com Tel. +34 91 30 41 139 UNITED STATES BERNARD CONTROLS Inc HOUSTON inquiry.usa@bernardcontrols.com Tel. +1 281 578 66 66 Exhaustive list of agents and distributors on www.bernardcontrols.com Invest in Confidence BERNARD CONTROLS 4 rue d Arsonval - CS 70091 95505 Gonesse CEDEX France Tel. : +33 (0)1 34 07 71 00 Fax : +33 (0)1 34 07 71 01 mail@bernardcontrols.com www.bernardcontrols.com A123/05b All data in this brochure are given for information only and are subject to change without notice.