Address: IES LM Luminaire Description: Indoor High Bay Light Source: LGIT 5630 Ballast/Driver: VPL Overdrive L320HBL46DIM/50K

Similar documents
Photometric Test Report

Photometric Test Report

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For GREEN LOGIC LED ELECTRICAL SUPPLY INC. Outdoor Full-Cutoff Wall-mounted Area Luminaire

LM Test Report

NVLAP LAB CODE LM Test Report. For MAXLITE,INC. (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006

71332 LED Dusk To Dawn (Area Light)

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

NVLAP LAB CODE LM Test Report. For. LED Waves, Inc st. Ave. Brooklyn, NY USA. Linear Retrofit Kits for 2x2 Luminaires

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

NVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires

LM Test Report

Photometric Test Report

NVLAP LAB CODE LM Test Report. For ATG ELECTRONICS CORP. (Brand Name: N/A) th Street Rancho Cucamonga, CA 91730

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen

Photometric Test Report

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

NVLAP LAB CODE LM Test Report. For EIKO GLOBAL, LLC W 84th St., Shawnee, KS

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires

REVOLUTION LIGHTING TECHNOLOGIES INC

LM Test Report

NVLAP LAB CODE LM Test Report. For SHENZHEN BONLD ELECTRONICS CO.,LTD. (Brand Name: BONLD)

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires

LM Test Report. For KEYSTONE TECHNOLOGIES LLC. (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454

LM Test Report

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. For BEYOND LED TECHNOLOGY Mountain Industrial Blvd. Suite A-1 Tucker, GA USA

LM Test Report. For. Torshare Ltd. (Brand Name: TORSHARE)

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA

57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

Cat# LED Wall-PACK

LM Test Report

Eternal Shine Technology Co.,Ltd. EST

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

LED Floodlight. RoHS. Model: inner box: L 17" X W 12.5" X H 9.33" 1PCS AC 50/60HZ. Input Voltage 0.85A MAX. Input Current 78 W.

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006

Cat# 71426A LED Wall-PACK QPL ID # PLO3JLI4OV69

Dark Sky Wallpack 50W. General ACD12 Aluminum Heat Sink High Light Transmittance Polycarbonate, Anti-UV and Fire Resistant Finish:

QPL ID # PLG2YNJ831VZ

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)

Cat# LED High Bay

Cat# 71440A LED Classic Large Wall-Pack

Direct to wall VAC / 30W PF ,290 LM 110 LM/W B2-U0-G1. Alluminium + Tempered Glass 24-48VDC 0.

Photometric Test Report

Photometric Test Report

Morris Products 53 Carey Road, Queensbury, NY 12804

RoHS VAC 50/60HZ 0.38A Max W PF LM LM/W x 90

71345A. 50W LED Floodlight Yoke(Bracket) Mount. RoHS QPL ID # PLDUWHES4P5Q. Model: 71345A

RoHS. Model: VAC 50/60HZ 0.127A Max 14.6 W PF LM LM/W x90 Aluminium Housing + Polycarbonate Lens

Dimming: PWM/TIME/0-5V/0-10V. RoHS

Cat# 71146A 150W Trunion Mount

RoHS VAC 50/60HZ 1.8A Max 150W PF LM 123 LM/W x 90 Aluminium + PC Lens 36-60VDC 4.4A 88% Philips 3030 LED 36 PCS

71352A QPL ID # PLT2P2L2UNWR. RoHS

RoHS QPL ID # PLC6V1PABNUJS


RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W FlatPanel Pole Mount. EPA Rating 2.33ft 2.

NVLAP LAB CODE Energy Star Test Report. For. Shenzhen OKT Lighting Co.,LTD

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U

RoHS. Model: VAC 50/60HZ.83A Max 100W

RoHS QPL ID # P9JSE2P8. Cat# Watts Trunion Mount. Model: master carton: L*W*Hmm 1PCS. EPA Rating 1.


NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd. Rm 1902, Easey Comm Bldg Hennessy Rd Wanchai, HONG KONG

LM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50

RoHS QPL ID # PNZ72BAB

RoHS QPL ID # PNZ72BAB

TEST REPORT. Job No SHA Date: Apr 12,2017 REPORT NO SHA-006. TEST OF ONE LED Luminaire MODEL NO.

Cat# LED Classic MINI Wall-PACK

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:

Photometric Test Report

LM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

LM Test Report. For SHENZHEN SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 61-70)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

LM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

Test Report. Report No.: EED35I Page 1 of 10. Customer : EIKO GLOBAL LLC Address : W 84TH ST SHAWNEE, KS USA

LM Test Report. for Elec-Tech International Co., Ltd. BR40 LAMP Model: XX(XX:01-10), WBR40L27S2A

Transcription:

Customer Company & Address: Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase2 Extn. Contact Person: Mohit K Mittal Phone Number: +91 9811204494 Email Address: mohit@overdriveasia.com Relevant Standards: Product Description: Brand Name: Tested Model Number: Product Family: Allowable Variations: Electrical Specification: IES LM-79-2008 Luminaire Description: Indoor High Bay Light Source: LGIT 5630 Ballast/Driver: VPL100-240 Overdrive L320HBL46DIM/50K N/A Different types of diffuser, clear or frosted 120~277 V AC, 50~60 Hz, 320 W Test Laboratory & Address: UL Verification Services (Guangzhou) Co., Ltd. ADD: Building A1, 1F & 2F, Nansha Science and Technology Innovation Center, No. 25, South Huanshi Avenue, Nansha District, Guangzhou 511458, China Telephone: +86 20 28667188 Fax: +86 20 83486605 Sample Reception Date: 2015-12-14 Test Date: 2016-01-06 Tested By Approved By /Jonathan Xu Signatory & Test Personnel Name Signatory & Approval Name /Duff Yang The results reported herein have been performed in accordance with the laboratory s terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. This report does not imply that the product(s) has met the criteria for certification. Issue No: 1.2 Page 1 of 10

Statement of Results Test Flow Test Item Sample ID (Lab) Pass/Fail/NA 1 Integrating Sphere Test 2270262-S1 Evaluate by customer 2 Goniophotometer Test 2270262-S1 Evaluate by customer 3 THD and PF Test 2270262-S1 Evaluate by customer Deviation from Test Method (if any ) N/A Remark (if any) 1. This report shall not be used by the client to claim product endorsement by NVLAP, NIST or any agency of the US government. 2.The THD test data within this report comes from UL-CCIC Company Limited(NVLAP Lab Code:600106-0). Issue No: 1.2 Page 2 of 10

Test Flow 1 : Integrating Sphere Test Environmental Conditions Temperature: 25.1 Test Equipment Equipment ID Equipment Name Last Calibration Date GVS-LE-PE003 3-meter Integrating Sphere Before Use GVS-LE-FS009 Measurement Standard Lamp 2015-08-22 Calibration Due Date Before Use 2016-06-21 Test Sample 2270262-S1 Test Method The sample was tested according to the IES LM-79-2008. Photometric paramters were measured using an integrating sphere, a spectroradiometer and software. The ambient temperature condition inside the sphere was maintained at 25º C ± 1º C. The sample measurements were made using a spectroradiometer connected by a fiber optic cable and detector through the detector port of the integrating sphere. The sample was operated at rated voltage and was stabilized before measurement. Chromaticity coordinates, correlated color temperature and color rendering index were calculated from the spectral radiant flux measurements taken at 1 nm intervals over the range of 380 to 780 nm. Test Results Test Type Voltage (V AC) Frequency (Hz) Current (A) Power Factor Power(W) Input 120.00 60 2.663 0.999 319.2 Test Type CCT (K) CRI Lumen Output (lm) Luminous Efficacy (lm/w) Output 4189 84 37301 116.8 Issue No: 1.2 Page 3 of 10

Issue No: 1.2 Page 4 of 10

Test Flow 2: Goniophotometer Test Environmental Conditions Temperature: 25.1 º C Test Equipment Equipment ID Equipment Name Last Calibration Date Calibration Due Date GVS-LE-GS003 3-meter Goniophotometer Before Use Before Use GVS-LE-FS009 Measurement Standard Lamp 2015-08-22 2015-08-21 Test Sample 2270262-S1 Test Method The sample was tested according to the IES LM-79-2008. Photometric paramters were measured using a type C goniophotometer and software. The ambient temperature shall be maintained at 25 C ± 1 C, measured at a point not more than 1 m from the sample and at the same height as the sample. The samples were operated at rated voltage and was stabilized before measurement. Luminous flux, luminaire efficacy, zonal lumen were calculated from the software taken at 0.5 o vertical intervals and 22.5 o horizontal intervals. Test Results Test Type Voltage (V AC) Frequency (Hz) Current (A) Power Factor Power (W) Input 120.00 60 2.663 0.999 319.2 Test Type Lumen Output (lm) Center Beam Candle Power (cd) Field angle (10%) Horizontal Spread Vertical Spread Beam angle (50%) Horizontal Spread Vertical Spread Luminous Efficacy (lm/w) Output 37733 14962 154.9 156.9 99.9 104.2 118.2 Issue No: 1.2 Page 5 of 10

Illuminance at a Distance Polar Candela Distribution Isolux Plot Issue No: 1.2 Page 6 of 10

Zonal Lumen Tabulation Issue No: 1.2 Page 7 of 10

Intensity Data(cd) Issue No: 1.2 Page 8 of 10

Test Flow 3: THD and PF Test Environmental Conditions Temperature: 25.1 º C Test Equipment Equipment ID Equipment Name Last Calibration Date Calibration Due Date 122302 Power Analyzer 09/16/2015 09/15/2016 Test Sample 2270262-S1 Test Method The samples were tested according to the ANSI C82.77-2002. The ambient temperature condition was maintained at 25º C ± 1º C. The sample measurement was made using a digital power meter and power supply. The sample was operated at rated voltage and stabilized before measurement. The total harmonic distortion were calculated from thedigital power meter. Test Results Test Type Voltage (V AC) Frequency (Hz) Current (A) Power Factor Current THD Power (W) Input 277.04 60 1.160 0.971 8.6% 311.9 Issue No: 1.2 Page 9 of 10

Photos of sample End of Issue No: 1.2 Page 10 of 10