Customer Company & Address: Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase2 Extn. Contact Person: Mohit K Mittal Phone Number: +91 9811204494 Email Address: mohit@overdriveasia.com Relevant Standards: Product Description: Brand Name: Tested Model Number: Product Family: Allowable Variations: Electrical Specification: IES LM-79-2008 Luminaire Description: Indoor High Bay Light Source: LGIT 5630 Ballast/Driver: VPL100-240 Overdrive L320HBL46DIM/50K N/A Different types of diffuser, clear or frosted 120~277 V AC, 50~60 Hz, 320 W Test Laboratory & Address: UL Verification Services (Guangzhou) Co., Ltd. ADD: Building A1, 1F & 2F, Nansha Science and Technology Innovation Center, No. 25, South Huanshi Avenue, Nansha District, Guangzhou 511458, China Telephone: +86 20 28667188 Fax: +86 20 83486605 Sample Reception Date: 2015-12-14 Test Date: 2016-01-06 Tested By Approved By /Jonathan Xu Signatory & Test Personnel Name Signatory & Approval Name /Duff Yang The results reported herein have been performed in accordance with the laboratory s terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. This report does not imply that the product(s) has met the criteria for certification. Issue No: 1.2 Page 1 of 10
Statement of Results Test Flow Test Item Sample ID (Lab) Pass/Fail/NA 1 Integrating Sphere Test 2270262-S1 Evaluate by customer 2 Goniophotometer Test 2270262-S1 Evaluate by customer 3 THD and PF Test 2270262-S1 Evaluate by customer Deviation from Test Method (if any ) N/A Remark (if any) 1. This report shall not be used by the client to claim product endorsement by NVLAP, NIST or any agency of the US government. 2.The THD test data within this report comes from UL-CCIC Company Limited(NVLAP Lab Code:600106-0). Issue No: 1.2 Page 2 of 10
Test Flow 1 : Integrating Sphere Test Environmental Conditions Temperature: 25.1 Test Equipment Equipment ID Equipment Name Last Calibration Date GVS-LE-PE003 3-meter Integrating Sphere Before Use GVS-LE-FS009 Measurement Standard Lamp 2015-08-22 Calibration Due Date Before Use 2016-06-21 Test Sample 2270262-S1 Test Method The sample was tested according to the IES LM-79-2008. Photometric paramters were measured using an integrating sphere, a spectroradiometer and software. The ambient temperature condition inside the sphere was maintained at 25º C ± 1º C. The sample measurements were made using a spectroradiometer connected by a fiber optic cable and detector through the detector port of the integrating sphere. The sample was operated at rated voltage and was stabilized before measurement. Chromaticity coordinates, correlated color temperature and color rendering index were calculated from the spectral radiant flux measurements taken at 1 nm intervals over the range of 380 to 780 nm. Test Results Test Type Voltage (V AC) Frequency (Hz) Current (A) Power Factor Power(W) Input 120.00 60 2.663 0.999 319.2 Test Type CCT (K) CRI Lumen Output (lm) Luminous Efficacy (lm/w) Output 4189 84 37301 116.8 Issue No: 1.2 Page 3 of 10
Issue No: 1.2 Page 4 of 10
Test Flow 2: Goniophotometer Test Environmental Conditions Temperature: 25.1 º C Test Equipment Equipment ID Equipment Name Last Calibration Date Calibration Due Date GVS-LE-GS003 3-meter Goniophotometer Before Use Before Use GVS-LE-FS009 Measurement Standard Lamp 2015-08-22 2015-08-21 Test Sample 2270262-S1 Test Method The sample was tested according to the IES LM-79-2008. Photometric paramters were measured using a type C goniophotometer and software. The ambient temperature shall be maintained at 25 C ± 1 C, measured at a point not more than 1 m from the sample and at the same height as the sample. The samples were operated at rated voltage and was stabilized before measurement. Luminous flux, luminaire efficacy, zonal lumen were calculated from the software taken at 0.5 o vertical intervals and 22.5 o horizontal intervals. Test Results Test Type Voltage (V AC) Frequency (Hz) Current (A) Power Factor Power (W) Input 120.00 60 2.663 0.999 319.2 Test Type Lumen Output (lm) Center Beam Candle Power (cd) Field angle (10%) Horizontal Spread Vertical Spread Beam angle (50%) Horizontal Spread Vertical Spread Luminous Efficacy (lm/w) Output 37733 14962 154.9 156.9 99.9 104.2 118.2 Issue No: 1.2 Page 5 of 10
Illuminance at a Distance Polar Candela Distribution Isolux Plot Issue No: 1.2 Page 6 of 10
Zonal Lumen Tabulation Issue No: 1.2 Page 7 of 10
Intensity Data(cd) Issue No: 1.2 Page 8 of 10
Test Flow 3: THD and PF Test Environmental Conditions Temperature: 25.1 º C Test Equipment Equipment ID Equipment Name Last Calibration Date Calibration Due Date 122302 Power Analyzer 09/16/2015 09/15/2016 Test Sample 2270262-S1 Test Method The samples were tested according to the ANSI C82.77-2002. The ambient temperature condition was maintained at 25º C ± 1º C. The sample measurement was made using a digital power meter and power supply. The sample was operated at rated voltage and stabilized before measurement. The total harmonic distortion were calculated from thedigital power meter. Test Results Test Type Voltage (V AC) Frequency (Hz) Current (A) Power Factor Current THD Power (W) Input 277.04 60 1.160 0.971 8.6% 311.9 Issue No: 1.2 Page 9 of 10
Photos of sample End of Issue No: 1.2 Page 10 of 10