FICHA TÉCNICA DE PRODUTO

Similar documents
ABB MEASUREMENT & ANALYTICS DATA SHEET. TB82 2-wire conductivity transmitters

FICHA TÉCNICA DE PRODUTO

TB404 Conductivity sensors. Perfect for use in standard to highly corrosive solutions

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Rosemount 3101, 3102, and 3105

FICHA TÉCNICA DE PRODUTO

IP26 Series Current to Pneumatic Converter

Conductivity Analyzer

SITRANS T measuring instruments for temperature

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

General Specifications

AT200 External Mount Magnetostrictive Level Transmitter

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter

Positioner with HART Communication Type 3780

Features and Applications

Remote Controlled FOUNDATION Fieldbus Two-Wire ph/orp Transmitter

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

Field indicator for current loops with HART communication Models DIH50, DIH52

LST100 Ultrasonic level transmitter for upstream oil and gas

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

2-Wire Toroidal Conductivity Transmitters Series APT2000 Specifications

Rosemount 148 Temperature Transmitter

LST400 Ultrasonic level / open channel flow transmitter

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

TIY Programmable, Isolated Thermocouple Transmitter combines

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

Analyze IT Single and Dual Input Analyzers for ph/redox (ORP)

Resistance thermometer Model TR30, compact design

Head mounted Temperature Transmitter TF02/TF02-Ex

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

TWO-WIRE TRANSMITTERS FOR ph, ORP, CONDUCTIVITY, OXYGEN, OZONE, AND CHLORINE

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

FICHA TÉCNICA DE PRODUTO

Rosemount 148 Temperature Transmitter

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. TTF200 Field-mount temperature transmitter

Level Measurement Continuous level measurement Radar transmitters

Process display RIA 261

Temperature Measurement

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

TwO-wIRE TRANSmITTERS FOR ph, ORP, CONDUCTIvITy, OxygEN, OzONE, AND CHLORINE

General Specifications

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

MEAS CAL ALARM CONF APT2000 TC

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

Loop Powered Indicator

General Specifications

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Model 264IB. ABB 2600T Series Engineered solutions for all applications

General Specifications

Humidity Sensor/Transmitter Assembly

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

The Rosemount 848T Wireless Temperature Transmitter

AT200 Magnetostrictive Level Transmitter. External mounted magnetostrictive level transmitter K-TEK Products

Temperature Measurement Transmitters for mounting in sensor head

General Specifications

Fisher 4200 Series Electronic Position Transmitters

oxy.iq Panametrics Oxygen Transmitter Applications Features bhge.com Two-wire, loop-powered 4 to 20 ma transmitter An oxygen transmitter for use in:

PAD - Heavy Duty Differential Pressure Trasmitter

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Field indicator for current loops with HART communication Models DIH50, DIH52

AX460, AX466 and AX416 Single and dual input analyzers for ph/redox (ORP)

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

ABB conductivity analyzer and probe package

Temperature transmitter itemp PCP DIN rail TMT 121

Rosemount 148 Temperature Transmitter

TTH200 Head-mount temperature transmitter

Temperature Measurement Transmitters for mounting in sensor head

Fisher 646 Electro Pneumatic Transducer

Rosemount 148 Temperature Transmitter

Resistance thermometer Model TR30, compact design

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

Condumax CLS21 and CLS21D

General Specifications

Smart Pressure Transmitter

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

ABB MEASUREMENT & ANALYTICS DATA SHEET. AX460, AX466 and AX416 Single and dual input analyzers for ph/redox (ORP)

HART field temperature transmitter Models TIF50, TIF52, TIF62

Ultrasonic Liquid Level Transmitters

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

Temperature Measurement

process measurement solutions Mobrey MSP IP wire 24V loop powered ultrasonic level transmitters

AT100S Magnetostrictive Level Transmitter. Sanitary magnetostrictive level transmitter K-TEK Products

Kotron Model 82 CE RF Level Transmitter

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Field IT 2600T Series Pressure Transmitters

ABB MEASUREMENT & ANALYTICS DATA SHEET. AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers for low level conductivity

HART Compatible Intelligent 2-wire In-head Transmitters

Inductive conductivity measurement mypro CLM 431 / CLD 431 inductive

Transcription:

FICHA TÉCNICA DE PRODUTO PRODUCT DATASHEET HMI Automação e Instrumentação, Lda. Rua dos 5 Caminhos, nº 570 4780-382 Santo Tirso PORTUGAL Web: www.hmi.pt Tel. +351 252 850 501 Fax. +351 300 013 487 Email: hmi@hmi.pt

Data sheet DS/ACA592-EN Endura ACA592 Conductivity transmitter Rugged design transmitter for industrial applications Transmitter options for all sensor types 2-Electrode sensors for low conductivity measurement 4-Electrode sensors for wide range conductivity applications and slurries Toroidal conductivity for corrosive and heavy coating applications Unique 24 V DC two-wire transmitter Dual compartment design Tropicalized circuit boards Coated aluminum options IP 66 / 67, NEMA 4X Enclosure Through-the-glass (TTG) programming configuration No exposed internal circuitry Reduces downtime in hazardous areas Easy and flexible installation Intrinsically safe Non-incendive Dust-ignition proof Flameproof Explosion-proof Output options 4 to 20 ma with HART signal Continuous sensor and self-monitoring Electronics self-check Advanced sensor diagnostics Configuration Easy-to-configure menus FDT / DTM, EDD HART programming

Endura ACA592 Conductivity transmitter The Endura family of products ABB's Endura family of analytical transmitters are designed for the requirements of industrial customers. These 2-wire 24 VDC instruments are used in measurement and control applications in a broad range of industries including chemical, pulp & paper, mining, and petroleum refining. Scroll back Sensor compatibility The ACA592 transmitter is fully compatible with ABB's full range of conductivity sensors. 2-electrode, 4-electrode and toroidal conductivity transmitter options allow users to measure conductivity in applications from clean water to harsh chemicals. The ACA592 has automatic temperature sensor recognition for both 2- and 3-wire RTD inputs for common inputs such as Pt100, Pt1000, and 3k Balco. Rugged, yet familiar design All ABB electronics are based around a common design platform. The programming structure of the menus is similar from product to product. This means that operators spend less time learning how to work with a new product. The menu structure is based on a simple, mobile-phone style programming format. Exit / Cancel Fig. 1: Navigation keys Select Scroll forward The ACA592 is supplied as standard with a durable, powdercoat epoxy, aluminum housing suitable for corrosive environments. All programming can be done through the window display on the front of the transmitter. This means that internal circuitry is never exposed to the atmosphere. This feature is especially critical in hazardous areas as the transmitter does not need to be isolated from the ignition source. As added protection, each circuit board is conformal coated to prevent corrosion should humidity ever enter the transmitter enclosure. Transmitter selection Selection of an Endura 2-electrode, 4-electrode or toroidal conductivity transmitter and related sensor should be based on the requirements of the application. Model Sensor type Cell constant Suggested or group measurement range Suggested applications 0.01 0 to 5 µs/cm Ultrapure water ACA592 TE 2-electrode 0.1 5 to 500 µs/cm Boiler water 1.00 500 to 2000 µs/cm Potable water ACA592 EC ACA592 TC 4-electrode toroidal electrode-less Group A 5 µs to 1000 ms/cm Pulp stock, river water Group B 20 to 1000 µs/cm Fouled condensate 1000 µs/cm to 2000 to ms/cm Corrosive liquids Chemical concentration Applications that coat traditional sensors 2 DS/ACA592-EN Endura ACA592 Conductivity transmitter

Concentration measurement For users that use conductivity to infer liquid concentration, ABB provides pre-installed concentration curves for many common chemicals as well as a user-defined curve for customers to input their own conductivity vs. concentration curve. Concentration measurement options / range 0 to 15 % NaOH 0 to 20 % NaCI 0 to 18 % HCI 0 to 20 % H2SO4 User-defined Diagnostics (NE107 based) The ACA592 transmitter has continuous self monitoring of the electronics, input power, and sensor characteristics to ensure a reliable, accurate measurement. Operating diagnostic faults can be read through the operator screen on the LCD display. Sensor diagnostics include the following: Dirty sensor alarm Ground loops present or shorted sensor cable (damaged sensor cable) Open sensor cable Temperature over / under range (short- or open-circuited temperature sensor) Diagnostics availability is dependent on the transmitter model. Electronics S072.041 Snsr temperature over range Communications HART Standard digital HART Version 5.9 provides communication with any HART primary or secondary device. The HART signal is superimposed on the standard 4 to 20 ma current output. Error messages can also be sent over the HART digital signal for monitoring in the DCS control system. If simultaneous faults have occurred, the ACA592 can display them in order of severity. Hart programming can be done through DTM software or with conventional EDD. The latest version of the HART software can be downloaded from www.abb.com/analytical-instruments. Fig. 3: HART communications 1 Modem R = 250 1. DHH801, FC475 2. FDT / DTM technology or EDD technology 3. Ground connection (optional) 4. ABB Asset Vision Professional or DCS config. 2 3 4 Back Exit Fig. 2: Example diagnostic message Endura ACA592 Conductivity transmitter DS/ACA592-EN 3

Endura ACA592 Conductivity transmitter Technical data Input Sensor types ACA592 TE: ABB 2-electrode sensors ACA592 EC: ABB 4-electrode sensors ACA592 TC: ABB toroidal sensors Measurement range and resolution ACA592 TE (2-electrode conductivity transmitter): Cell constant Measurement Resolution / Accuracy range Linearity / Stability 0.01 0 to 200 µs/cm 0.001 µs/cm 0.1 0 to 2000 µs/cm 0.01 µs/cm 1 0 to 20000 µs/cm 0.1 µs/cm ACA592 EC (4-electrode conductivity transmitter): Sensor group Measurement Resolution / Accuracy range Linearity / Stability Group A 0 to 2000 ms/cm 0.1 µs/cm Group B 0 to 2000 µs/cm 0.01 µs/cm ACA592 TC (toroidal conductivity transmitter): Measurement Resolution / Accuracy Sensor range Linearity / Stability ABB toroidal 0 to 2000 ms/cm 1.0 µs/cm Temperature Temperature compensation Temperature element ACA592 TE ACA592 EC ACA592 TC Pt100 Pt1000 3k Balco Temperature compensation modes Measured liquid ACA592 EC and ACA592 TC: 0 to 15 % NaOH 0 to 20 % NaCI 0 to 18 % HCI 0 to 20 % H2SO4 User-defined Measured liquid ACA592 TE: Pure H2O neutral salt Pure H2O trace base Pure H2O trace acid User-defined: Dynamic response <3 Seconds for 90% step change at 0.00 seconds dampening Output Signal Configurable: 4 to 20 ma (standard with HART) User-programmable linear and non-linear across entire range. Dynamic range: 3.9 to 20.75 ma (3.8 ma = low alarm level, 21.5 ma = high alarm level) Minimum span Sensor type ACA592 TE ACA592 EC ACA592 TC 0.01 Cell 1 µs/cm 0.10 Cell 10 µs/cm 1.00 Cell 100 µs/cm Group A 100 µs/cm Group B 10 µs/cm Toroidal 100 µs/cm Input range 20 to 200 C ( 4 to 392 F) Accuracy / stability ±0.1 C (0.18 F) after calibration 4 DS/ACA592-EN Endura ACA592 Conductivity transmitter

Maximum span Sensor type ACA592 TE ACA592 EC ACA592 TC 0.01 Cell 200 µs/cm 0.10 Cell 2000 µs/cm 1.00 Cell 20 ms/cm Group A 2000 ms/cm Group B 2000 µs/cm toroidal 2000 ms/cm Damping Adjustable 0.0 to 99 seconds. Power supply (polarity safe) Supply voltage Us = 12 to 42 V DC (General purpose installations) Us = 12 to 30 V DC (Intrinsically Safe Ex ia) Maximum permissible ripple Maximum ripple for supply voltage during communication in accordance with HART FSK physical layer specification, version 8.1 (08/1999) section 8.1 Under-voltage protection UTerminal-Mu < 12 V results in Ia = 3.8 ma Maximum load Rload = (supply voltage 12 V) / 22 ma Max. load depending on supply voltage (V DC) General information Display update speed < 250 milliseconds Environmental (temperature) Operating: 20 to 60 C ( 4 to 140 F) Storage: 40 to 80 C ( 40 to 176 F) Humidity < 95 % RH non-condensing Enclosure protection Aluminum, die cast, chromized inside / outside, 70 µm epoxy powdercoat (aluminum, magnesium content < 6 %, copper-free < 0.5 %) Weight 1.3 Kg (3 lb.) Cable gland protection IP66 and 67 for plastic glands supplied with general purpose / intrinsically safe instruments. IP67 for stainless glands required for Ex d explosion-proof instruments. EMC and RF interference Emitted electromagnetic interference in accordance with EN61326-1 for Class A and Class B equipment. 1360 1000 795 A Galvanic isolation 900 V DC for 1 second (insulation test voltage) B 500 225 C V DC 12 17 42 20 30 40 A ACA592 transmitter, B ACA592 in Ex ia Design C HART Communication resistor Fig. 4: Maximum load Endura ACA592 Conductivity transmitter DS/ACA592-EN 5

Endura ACA592 Conductivity transmitter Equipment markings Intrinsic safety FM and CSA FM Class I, Div. 1, Groups A, B, C, D Class II/III, Div. 1, Group E, F, G; T4 Ta = 60 ºC CSA Class I, Div. 1, Groups A, B, C, D Class II, Div. 1, Groups E, F, G Class III, Div. 1; T4 Intrinsic safety ATEX / IECEx Approved for: II 1G Ex ia IIC T4 II 1D Ex iad A20 IP66 T135 C, 20 C Tamb 60 C Intrinsically safe and Ex ia IIC hazardous area Parameter Supply circuit Maximum voltage Ui = 30 V Maximum input current Ii = 160 ma Maximum power Pi = 0,8 W Internal inductance Li = 0,5 mh Internal capacitance Ci = 5 nf Type n (non-sparking) ATEX / IECEx Approved for: II 3 G Ex na IIC; T4 II 3 D Ex td A22 IP66 T135 C, 20 C Tamb 60 C Non-incendive FM* and CSA FM Class I, Div. 2, Groups A, B, C, D Class II/III, Div. 2, Group F, G; T4 Ta = 60 ºC CSA Class I, Div. 2, Groups A,B,C,D Class II, Div. 2, Groups F, G Class III, Div. 2; T4 *When installed in accordance with the installation drawing P0909, refer to the User Guide (OI/ACA592/EC EN, / OI/ACA592/TE EN or OI/ACA592/TC EN) Appendix B. Explosion-proof, ignition-proof FM and CSA FM XP, Class I, Div. 1, Groups A,B,C,D Class II/III, Div. 1, Group E, F, G; T4 Ta = 60 ºC CSA Class I, Div. 1, Groups A,B,C,D Class II, Div. 1, Groups E, F, G Class III, Div. 1; T4 Flameproof and dust protection ATEX / IECEx Approved for: II 2 G Ex d IIC T4 II 2 D Ex td A21 IP66 T135 C, 20 C Tamb 60 C Agency enclosure ratings IP66 and IP67 NEMA 4X Approvals CE mark The ACA592 including type B LCD display / configuration software meets all requirements for the CE mark in accordance with the applicable directives 2004/108/EC (EMC), 2006/95/ EC (LVD) and 94/9/EC (ATEX). Ex ia (Zone 0): LCIE 11 ATEX 3058 X IECEx LCI 11.0050X Ex d (Zone 1): LCIE 11 ATEX 3057 X IECEx LCI 11.0049X Ex na (Zone 2): LCIE 11 ATEX 1005 X IECEx LCI 11.0048X 6 DS/ACA592-EN Endura ACA592 Conductivity transmitter

ACA592 Transmitter dimensions Dimensions in mm (inches) 46.5 (1.83) 150 (5.91) 105 (4.15) 60.5 (2.38) 91.0 (3.58) 29.4 (1.16) 1 /2 in. NPT or M20 (common for all connections) A 65.5 (2.58) B 46.5 (1.83) 103 (4.06) M8 (depth 10mm) C D 112 (4.4) 168 (6.6) A Housing, left side view (display installation facing left) without cable glands (conduit threads NPT ½ in. or M20) B Housing, right side view (display installation facing right) without cable glands (conduit threads NPT ½ in. or M20) C Housing, bottom view (fastening screw thread M8 (depth 10 mm) D Housing, front view Endura ACA592 Conductivity transmitter DS/ACA592-EN 7

Endura ACA592 Conductivity transmitter Fitting dimensions Dimensions in mm (in.) A B C D 38.6 (1.52) 18.3 (0.72) 36.1 (1.42) 14.5 (0.57) E F G H 55.4 (2.18) 14.2 (0.56) 43.2 (1.70) 20.3 (0.80) A B C D E F G H 1 /2 in. NPT nylon cable gland (supplied for all non-explosion-proof housing versions) 1 /2 in. NPT nylon conduit plug (supplied for all non-explosion-proof housing versions) M20 nylon cable gland (supplied for all non-explosion-proof housing versions) M20 nylon conduit plug (supplied for all non-explosion-proof housing versions) 1 /2 in. NPT 316 stainless steel Ex d (Explosion-proof) cable gland (not included, must be ordered separately if user installations require it) 1 /2 in. NPT 316 stainless steel conduit plug (supplied when any Ex d options are ordered) M20 316 stainless steel Ex d (Explosion-proof) cable gland (not included, must be ordered separately if user installations require it) M20 316 stainless steel Ex d (Explosion-proof) conduit plug (supplied when any Ex d options are ordered) 8 DS/ACA592-EN Endura ACA592 Conductivity transmitter

Mounting and dimensions The wall and pipe installation set supports variable installation positions. Examples of some of the mounting options are shown below. The transmitter mounting screw allows infinitely adjustable positioning (0 to 360 ) of the transmitter. Wall-mounted installation Dimensions in mm (in.) Transmitter Mounting bolts Mounting bolts 174 (6.85) 211 (8.32) Wall-mounting bracket 239 (9.42) Pipe-mounted installation Dimensions in mm (in.) Transmitter Pipe max. Ø 50 mm (2 in.) 138 (5.45) 177 Pipe-mounting (7.00) 249 bracket (9.08) Endura ACA592 Conductivity transmitter DS/ACA592-EN 9

Endura ACA592 Conductivity transmitter Ordering information Endura transmitter series ACA592- X X X X X X X Code Input Conductivity 4-electrode Conductivity 2-electrode Conductivity toroidal EC TE TC See next page Explosion protection certification Without FM (Factory Mutual) Intrinsic Safety FM (Factory Mutual) Explosion-proof (requires Exd gland not included) FM (Factory Mutual) Non-incendive CSA (Canadian Standards Association) Intrinsic Safety CSA (Canadian Standards Association) Explosion-proof (requires Exd gland not included) CSA (Canadian Standards Association) Non-incendive ATEX / IECEx Intrinsic Safety ATEX / IECEx Flameproof (requires Exd gland not included) ATEX / IECEx Type n (non-sparking) Y 0 F 1 F 2 F 3 C 1 C 2 C 3 A 1 A 2 A 3 Housing Powder coated aluminum A Cable conduits M20 x 1.5 NPT 1 /2 in. 1 2 Output signal HART digital communication and 4 to 20 ma H 10 DS/ACA592-EN Endura ACA592 Conductivity transmitter

Additional ordering information Mounting hardware None Pipe or wall Identification tags None Stainless steel Mylar Documentation language German Italian Spanish French English (default) Portuguese Accessories (order separately) 1 /2 in. NPT nylon cable gland (one each) IS 1 /2 in. NPT nylon conduit plug (one each) IS M20 nylon cable gland (one each) IS/NI M20 nylon conduit plug (one each) IS/NI 1 /2 in. NPT 316 stainless steel Ex d (Explosion-proof) cable gland (one each) 1 /2 in. NPT 316 stainless steel Ex d (Explosion-proof) conduit plug (one each) M20 316 stainless steel Ex d (Explosion-proof) cable gland (one each) M20 316 stainless steel Ex d (Explosion-proof) conduit plug (one each) Spare wall- and pipe-mount kit Code B0 B2 T0 T1 T2 M1 M2 M3 M4 M5 M6 4TB9515-0285 4TB9515-0286 4TB9515-0287 4TB9515-0288 4TB9515-0289 4TB9515-0290 4TB9515-0291 4TB9515-0292 4TB9515-0283 Endura ACA592 Conductivity transmitter DS/ACA592-EN 11

Our offering: Actuators and Positioners Analytical Instruments Device Management, Fieldbus and Wireless Flow Measurement Force Measurement Level Measurement Natural Gas Measurement Pressure Measurement Recorders and Controllers Temperature Measurement HMI Automação e Instrumentação, Lda. Rua dos 5 Caminhos, nº 570 4780-382 Santo Tirso PORTUGAL Web: www.hmi.pt Tel. +351 252 850 501 Fax. +351 300 013 487 Email: hmi@hmi.pt

Contact us ABB Limited Process Automation Oldends Lane Stonehouse Gloucestershire GL10 3TA UK Tel: +44 1453 826 661 Fax: +44 1453 829 671 ABB Inc. Process Automation 843 N Jefferson Street PO Box 831 Lewisburg WV 24901-9509 USA Tel: +1 800-HELP-365 Fax: +1 304 647 1862 Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 2012 ABB All rights reserved 3KXA112592R1001 HART is a registered trademark of the HART Communication Foundation. DS/ACA592 EN 03.2012 ABB Engineering (Shanghai) Ltd. Process Automation No. 5, Lane 369, Chuangye Road 201319, Shanghai, P.R. China Phone: +86 (0) 21 6105 6666 Fax: +86 (0) 21 6105 6992 Mail: china.instrumentation@cn.abb.com www.abb.com