User Manual. All rights reserved. Specifications are subject to change without notice.

Similar documents
User Manual. All rights reserved. Specifications are subject to change without notice.

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

NOTE: Fully read and understand this manual before using this Digital Multimeter.

UT207A/208A/209A Operating Manual. Table of Contents

Digital Multimeter, Pen Type

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

DM-45 Digital Multimeter

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

User Manual Digital Multimeter. model no.: MSR-U1000

True RMS Digital Multimeter Model:

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

KMD-S04 Multímetro de bolsillo

400Amp True RMS AC/DC Clamp Meter Model EX613

DCM730. Digital Clamp Meter User s Manual

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

MS2109A AC/DC Clamp Meter. User Manual. Contents

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

USER'S MANUAL DMR-6700

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

Electrical Multimeter

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

Digital Clamp Meter Model: &

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

Model UT10A: OPERATING MANUAL Table of Contents (1)

Analog Technologies. Multimeter 15B and17b

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

200Amp AC Clamp Meter + NCV Model MA250

DDM350 Pen-Type Digital Multimeter User s Manual

Table of Contents GDM-356. Page

MODEL: D03128 CLAMP METER

15B & 17B. Users Manual. Multimeters

User Manual Digital Clamp Multimeter. model no.: MSR-C600

Electrical Multimeter

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

AMM-1022 Digital Multimeter USER`S MANUAL

15B & 17B. Multimeters. Users Manual

DIGITAL MULTIMETER AUTORANGING

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

400Amp True RMS AC Clamp Meter + NCV

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

902 FC. HVAC True-rms Clamp Meter

DVM1190 DIGITAL MULTIMETER

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

Model: &

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

ProfiScale MULTI Multimeter

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

312, 316, 318. Clamp Meter. Users Manual

AC/DC CLAMP METER USER S MANUAL

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

Handheld Digital Multimeter

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

Table of Content. The Statement Safety Statement Safety Instructions Safety Operation Specifications Safety Symbols...

Sales: Technical: Fax:

Model DIGITAL MULTIMETER

Model : OPERATING MANUAL Table of Contents (1)

Digital automotive analyser 13 function with ic

User s Guide. 400A AC/DC Clamp Meter. Model MA220

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

Item ref: UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE. User Manual

Not for Reproduction

Autoranging Multimeter Extech EX503

Mini Clamp Meter Model:

MS8223A. CAT.IIi 600 V

Handheld Digital Multimeter PRO-50A

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

User Manual Digital Multimeter

OPERATOR S INSTRUCTION MANUAL

Handheld Digital Multimeter

DIGITAL MULTIMETER INSTRUCTION MANUAL

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

The Meter Structure The Figure 2-1 shows the Meter structure.

400Amp True RMS AC/DC Clamp Meter with IR Thermometer Model EX623

Models 110, 111 & 112

USER S MANUAL DMR-1500

MANUAL DE INSTRUÇÕES DO MULTÍMETRO DIGITAL MODELO MD-6456 Inglês

Table of Contents Title Page

CONTENTS MS2033A. 1.Introduction Safety Information...01

Model UT201/202: OPERATING MANUAL. Table of Contents

Pocket Size Digital Multimeter with USB Model: A & A

Compact MultiMeters + Voltage Detector

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

Pocket Size Digital Multimeter Models: and

VC835 DIGTAL MULTIMETER Operation Manual

True-rms Multimeter. Users Manual

Transcription:

User Manual All rights reserved. Specifications are subject to change without notice.

LIMITED WARRANTY AND LIMITATION OF LIABILITY Customers enjoy one-year warranty from the date of purchase. This warranty does not cover fuses, disposable batteries, damage from misuse accident, neglect, alteration, contamination, or abnormal conditions of operation or handling, including failures caused by use outside of the product's specifications, or normal wear and tear of mechanical components.

Table of Contents Page Introduction...1 Safety Information...1 Instrument Overview...3 LCD Display...3 Function Buttons...5 Rotary Switch...7 Input Terminals...9 Measurements Instruction...10 Measure AC/DC Voltage...10 Measure AC/DC Current...10 Measure Resistance...11 Test for Continuity...12 Test Diodes...12 Measure Capacitance...13 Measure Frequency...14 Measure Duty Cycle...15 Measure Temperature...15 Test NCV 16

Maintenance...17 Clean the Product...17 Replace the Batteries...17 Replace the Fuses...18 Specifications...19 General Specifications...19 Mechanical Specifications...19 Environmental Specifications...19 Electrical Specifications...20

Introduction This product is the world's first 9999 counts palmsize auto-ranging digital multimeter. The product is battery-powered with true-rms, a LCD display and a backlight. Safety Information To avoid possible electrical shock, fire, or personal injury, please read all safety information before you use the product. Please use the product only as specified, or the protection supplied by the product can be compromised. Examine the case before you use the product. Look for cracks or missing plastic. Carefully look at the insulation around the terminals. The measurement must be made with correct input terminals and functions and within the allowable measuring range. Do not use the product around explosive gas, vapor, or in damp or wet environments. 1

Keep fingers behind the finger guards on the probes. When the product has already been connected to the line being measured, do NOT touch the input terminal that is not in service. Disconnect the test leads from the circuit before changing the mode. When the voltage to be measured exceeds 36V DC or 25V AC, the operator shall be careful enough to avoid electric shock. Misuse of mode or range can lead to hazards, be cautious. will be shown on the display when the input is out of range. Low level of a battery will result in incorrect readings. Change the batteries when battery level is low. Do not make measurements when the battery door is not properly placed. 2

Instrument Overview LCD Display 1 2 3 4 5 6 7 8 18 17 16 15 9 14 13 12 11 10 1 2 3 4 5 6 Continuity test. Temperature test. (Fahrenheit or Celsius) Diode test. Duty cycle test. Display freezes present reading. Resistance test. (Ohm) 3

7 8 9 10 11 12 13 14 15 16 17 18 Frequency test. (Hertz) Capacitance test. (Farad) Voltage test. (Volt) Current test. (Ampere) Manual range. The user selects the range. Auto range. The product selects the range with the best resolution. The product measures both sinusoidal and nonsinusoidal ac waveforms accurately. Low battery. Replace batteries. Alternating current. Direct current. Negative readings. Unsafe Voltage. Measurement units. 4

Function Buttons 1 2 1 Range/Backlight Button Push this button once to enter the manual range mode. In manual range mode, each push increases the range; when the highest range is reached, the next push will lead to the lowest range. To exit the manual range mode, turn the rotary switch. Push for more than 2 seconds to turn on the backlight; long-push again to turn off or the backlight automatically turns off after 2 minutes. 5

2 SEL/HOLD Button Push to select alternate measurement modes on a rotary switch setting, including: 1. DC V/AC V/Frequency/Duty Cycle 2. DC mv/ac mv/temperature 3. Resistance/ Continuity/ Diode/ Capacitance 4. Frequency/Duty Cycle 5. DC A/AC A 6. DC μa/ac μa 7. NCV Push for more than 2 seconds to hold the current reading on the display; long-push again to continue normal operation. 6

Rotary Switch Turn off the product at this position. The product automatically powers off after 15 minutes of inactivity. The built-in beeper beeps 5 times 1 minute before auto power off. To restart the product from auto power off, press the SEL/HOLD button or turn the rotary switch back to the OFF position and then to a needed position. To disable the Auto Power Off function, hold down the SEL/HOLD button when turning on the product, you will hear five beeps if you have successfully disabled the function. 7

DC voltage 999.9V AC voltage 750V Frequency with high voltage Duty Cycle from 1%~99% DC voltage 99.99mV AC voltage 99.99mV Celsius: -20~1000 Fahrenheit: -4~1832 Ohms 99.99MΩ Continuity. Beeper turns on at <50Ω Diode test. Displays above 3V Farads 9.999mF Frequency with low voltage Duty Cycle from 1%~99% DC A 9.999A AC A 9.999A DC A 999.9μA AC A 999.9μA Non-contact voltage test. 8

Input Terminals A ma COM VΩHz Input terminal for AC/DC current measurements to 9.999A. Common (return) terminal for all measurements. Input terminal for the measurements of: 1. AC/DC voltage 2. Resistance 3. Capacitance 4. Frequency 5. Temperature 6. Continuity 7. Diode 8. Duty cycle 9. AC/DC current to 999.9μA 9

Measurements Instruction Measure AC/DC Voltage 1. Connect the black test lead to the COM Terminal and the red lead to the VΩHz Terminal. 2. Turn the rotary switch to or to. 3. Press SEL to toggle between AC/DC. 4. Touch the probes to the correct test points of the circuit to measure the voltage. 5. Read the measured voltage on the display. *Do not measure voltage that exceeds the extremes as indicated in the Specifications. *Do not touch high voltage circuit during measurements. Measure AC/DC Current 1. Connect the black test lead to the COM Terminal and the red lead to the VΩHz Terminal or the A ma Terminal (choose based on the value of the current to be measured). 10

2. Turn the rotary switch to or. 3. Press SEL to toggle between AC/DC. 4. Break the circuit path to be measured, connect the test leads across the break and apply power. 5. Read the measured current on the display. *Do not measure current that exceeds the extremes as indicated in the Specifications. *Use the A ma Terminal and the Mode when you are measuring an unknown current. Then switch to the VΩHz Terminal and the Mode if necessary. *Do not input voltage at this setting. Measure Resistance 1. Connect the black test lead to the COM Terminal and the test lead to the VΩHz Terminal. 2. Turn the rotary switch to, and the display will show. 3. Touch the probes to the desired test points of the circuit to measure the resistance. 4. Read the measured resistance on the display. 11

*Disconnect circuit power and discharge all capacitors before you test resistance. *Do not input voltage at this setting. Test for Continuity 1. Connect the black test lead to the COM Terminal and the red lead to the VΩHz Terminal. 2. Turn the rotary switch to, press SEL once to toggle to the Continuity Mode. 3. Touch the probes to the desired test points of the circuit. 4. The built-in beeper will beep when the resistance is lower than 50Ω, which indicates a short circuit. *Do not input voltage at this setting. Test Diodes 1. Connect the black test lead to the COM Terminal and the red lead to the VΩHz Terminal. 12

2. Turn the rotary switch to, press SEL twice to toggle to the Diode Mode. 3. Connect the red probe to the anode side and the black probe to the cathode side of the diode being tested. 4. Read the forward bias voltage value on the display. 5. If the polarity of the test leads is reversed with diode polarity or the diode is broken, the display reading shows. *Do not input voltage at this setting. *Disconnect circuit power and discharge all capacitors before you test diode. Measure Capacitance 1. Connect the black test lead to the COM Terminal and the red lead to the VΩHz Terminal. 2. Turn the rotary switch to, press SEL three times to toggle to the Capacitance Mode. 13

3. Connect the red probe to the anode side and the black probe to the cathode side of the capacitor being tested. 4. Read the measured capacitance value on the display once the reading is stablized. *Disconnect circuit power and discharge all capacitors before you test capacitance. Measure Frequency 1. Connect the black test lead to the COM Terminal and the red lead to the VΩHz Terminal. 2. Turn the rotary switch to (applies to low frequency with high voltage), press SEL twice to toggle to the Frequency Mode; or turn the rotary switch to (applies to high frequency with low voltage). 3. Touch the probes to the desired test points. 4. Read the measured frequency value on the display. 14

Measure Duty Cycle 1. Connect the black test lead to the COM Terminal and the red lead to the VΩHz Terminal. 2. Turn the rotary switch to (applies to low frequency with high voltage), press SEL three times to toggle to the Duty Cycle Mode; or turn the rotary switch to (applies to high frequency with low voltage), press SEL once to toggle to the Duty Cycle Mode. 3. Touch the probes to the desired test points. 4. Read the measured duty cycle value on the display. Measure Temperature 1. Connect the black thermocouple probe to the COM Terminal and the red probe to the VΩHz Terminal. 15

2. Turn the rotary switch to, press SEL three times to measure temperature( ), or press SEL four times to measure temperature( ). 3. Touch the probes to the desired test points. 4. Read the measured temperature on the display. *Do not input voltage at this setting. Test NCV 1. Turn the rotary switch to. 2. Hold the product and move it around, the builtin beeper will beep when the inner sensor detects AC voltage nearby. The stronger the voltage is, the quicker the beeper beeps. 16

Maintenance Beyond replacing batteries and fuses, do not attempt to repair or service the product unless you are qualified to do so and have the relevant calibration, performance test, and service instructions. Clean the Product Wipe the product with a damp cloth and mild detergent. Do not use abrasives or solvents. Dirt or moisture in the terminals can affect readings. *Remove the input signals before you clean the product. Replace the Batteries When is shown on the display, batteries shall be replaced as below: 1. Remove the test leads and turn off the product before replacing the batteries. 17

2. Loosen the screw on the battery door and remove the battery door. 3. Replace the used batteries with new batteries of the same type. 4. Place the battery door back and fasten the screw. Replace the Fuses When a fuse is blown or do not work properly, it shall be replaced as below: 1. Remove the test leads and turn off the product before replacing the fuse. 2. Loosen the four screws on the back cover and the screw on the battery door, then remove the battery door and the back cover. 3. Replace the fuse with a new fuse of the same type. 4. Place the back cover and the battery door back and fasten the screws. 18

Specifications General Specifications Display(LCD) 9999 Counts Ranging Auto/Manual Material ABS Update Rate 3 Times/Second Ture RMS Data Hold Backlight Low Battery Indication Auto Power Off Mechanical Specifications Dimension 130*65*32mm Weight 114g Battery Type 1.5V AAA Battery * 2 Warranty One year Environmental Specifications Operating Temperature 0~40 Humidity <75% Storage Temperature -20~60 Humidity <80% 19

Electrical Specifications Function Range Resolution Accuracy 999.9mV 0.1mV DC Voltage (V) 9.999V 0.001V 99.99V 0.01V 999.9V 0.1V ±(0.5%+3) DC Voltage (mv) 9.999mV 99.99mV 999.9mV 0.001mV 0.01mV 0.1mV AC Voltage (V) 9.999V 0.001V 99.99V 0.01V 750.0V 0.1V ±(1.0%+3) AC Voltage (mv) 9.999mV 99.99mV 0.001mV 0.01mV 20

Function Range Resolution Accuracy DC Current (ma&a) DC Current (μa) AC Current (ma&a) AC Current (μa) Resistance 999.9mA 0.1mA ±(1.0%+3) 9.999A 0.001A 99.99μA 0.01μA 999.9μA 0.1μA 999.9mA 0.1mA 9.999A 0.001A 99.99μA 0.01μA 999.9μA 0.1μA ±(0.8%+3) ±(1.2%+3) ±(1.0%+3) 99.99Ω 0.01Ω ±(1.0%+3) 999.9Ω 0.1Ω 9.999kΩ 0.001kΩ 99.99kΩ 0.01kΩ 999.9kΩ 0.1kΩ 9.999MΩ 0.001MΩ 99.99MΩ 0.01MΩ ±(0.5%+3) ±(1.5%+3) 21

Function Range Resolution Accuracy 9.999nF 0.001nF ±(5.0%+20) 99.99nF 0.01nF 999.9nF 0.1nF Capacitance 9.999μF 0.001μF ±(2.0%+5) 99.99μF 0.01μF 999.9μF 0.1μF 9.999mF 0.001mF ±(5.0%+5) 99.99Hz 0.01Hz 999.9Hz 0.1Hz Frequency 9.999kHz 99.99kHz 0.001kHz 0.01kHz ±(0.1%+2) 999.9kHz 0.1kHz 9.999MHz 0.001MHz Duty Cycle 1%~99% 0.1% ±(0.1%+2) 22

Function Range Resolution Accuracy Temperature (-20~1000) 1 ±(2.5%+5) (-4~1832) 1 Diode Continuity NCV 23