INSTALLATION INSTRUCTIONS SUPERPLANE 4 WALL MOUNT. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

Similar documents
SUPERPLANE 2.5 INSTALLATION INSTRUCTIONS WALL/SURFACE BACK MOUNT. A nd Avenue, Unit 1 Oakland,

SUPERPLANE TM 4 RECESSED SP4R

ROUND LIGHTPLANE 1 3D FLUSH

INSTALLATION INSTRUCTIONS Oculux 3.5 Architectural Remodel

INSTALLATION INSTRUCTION OCULUX 3 LED - New Construction

INSTALLATION INSTRUCTION Silo Multiples - New Construction Housing MT-4*15, MT-4*10

INSTALLATION INSTRUCTION Indirect Recessed Channel

DAZZLE ACCENT LIGHTING SYSTEM

REGOLO GENERAL WARNING

THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

DISCONNECT POWER PRIOR TO ANY INSTALLATION.

Install the Housing. Installation Instructions for Entra Round or Square Type IC, Air-tight New Construction Adjustable LED Housing EN3_-LH9_ 1.

- 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS. Factory pre-installed mud flange TOOLS REQUIRED: Phillips screwdriver, 5/16 nut driver.

T9i Treadmill. Assembly Instructions

WARNINGS & SAFETY INFORMATION: PLEASE READ CAREFULLY AND KEEP A COPY ON THE PROPERTY FOR FUTURE REFERENCE!

Line volt rail & fixtures. Low volt quick connect fixtures with transformers

Installation Instructions Standalone or continuous run configurations - 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS

INSTALLATION INSTRUCTION Accent

Aliante Installation. Components included: Tools required: Not Included:

INSTALLATION INSTRUCTION Accent

INSTALLATION INSTRUCTION Grand Accent

LINESSE LINEAR LUMINAIRE 3 CEILING MOUNT CM2420

Home Control. Installation Guide FOUR SWITCHES

Lightplane 3.5 Recessed

INSTALLATION INSTRUCTION Adjustable Spot - Endurance Sign Lighting

INSTALLATION INSTRUCTION Vibe - dwelled LED Picture Lights

EOS LED Surface Mounted Luminaire

SeriesTWO RGB Fluorescent Fixtures. Installation and Instruction Manual

EOS Direct/Indirect LED Pendant Luminaire

PRODUCT: LOKI INSTALLATION INSTRUCTIONS. Product is covered by U.S. patents. For more information visit

INSTALLATION INSTRUCTION Solorail - Low Voltage Starter Kit

A-dec 574L and 575L Dental Lights on a Cabinet or Wall INSTALLATION GUIDE

-Always de-energize the circuit and/or equipment before connecting to, disconnecting from or servicing the equipment.

2 Pendant Adjustment. Pendant Slider Plate. 3/4 (19mm) IP, (29mm) O.D. Knockouts. 1/2 (13mm) IP, (22mm) O.D. Knockout

INSTALLATION INSTRUCTIONS Xenix Incandescent Series XN12, XN24, XN36, XN48

LIGHT FIXTURES MUST BE COMPLETELY INSTALLED PRIOR TO CEILING CONSTRUCTION

RAIL 4 PERIMETER RP4D RECESSED T-BAR LED TELESCOPIC, INTEGRAL DRIVER

Installation Instructions

INSTALLATION: D1-NOTCH DRYWALL TRIM FLANGE

Multiples EM_ 1.4. Install 1X1/1X2/1X3/1X4 Housings. Installation Instructions for. This product is suitable for indoor locations.

INSTALLATION INSTRUCTION Accent

HP-2 / HP-4 Wall Wash Recessed T-Bar Installation Instructions Overview

Round or Square Chicago Plenum Down Light Housing with Lamp

HO4 Surface Mount Installation Instructions Overview

TVB-2 INSTRUCTION SHEET. Test Verification Box

CXB Series SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Luminaire TO INSTALL: INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION

Installation Instructions for TruLine 1.6A 24VDC. Section One: Basic Configuration Options

Instruction Sheet VDM-200-T. Tilt Wall Mount

INSTALLATION INSTRUCTION LED Wall Sconce WS-21718

Instruction Sheet. VDM Series. Tilt Low Profile Mount

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

HP-2 Recessed Wall Wash Flush Diffuser Tech Zone 4" Starter/Independent Installation Instructions

MaxLite Linear Strip ECO Series

General Installation Instructions LED

General Installation Instructions

SAE of 7 "R" (REGRESSED) POSITION "S" (SHIELDING AT TOP) POSITION. Tools Required

HOLLY HUNT LIGHTING. STUDIO H EDGE CHANDELIER Installation Instructions

Installation Instructions

KANEKA OLED Lighting Module SL (LE-01L, LE-02L, LE-03L, LE-01H, LE-02H, LE-03H) Instruction Manual

WARNING IMPORTANT: NEVER

Arched Top Lantern Pendant Assembly and Installation Instructions. Country of Destination: US/CN UK/EU/AUS Middle East

Hi-lume A-Series Driver Overview Forward-Phase Control

INSTALLATION INSTRUCTIONS FIXTURE SERIES: SAE 202 MOUNTING TYPE: RECESSED WALL / SLOT PAGE: 1 OF 8

Instruction Sheet. VDM Series FIXED & TILT WALL MOUNT

ASYX 2.0 S3-S4-L3-L4-L5-L6 Wall Installation Instructions

EXPLODED VIEW AND PART CALL OUT ASSEMBLING THE METALUX DF SERIES FRAME KIT

Sable Frame Series. Fixed Frame Projection Screen. Featuring CineGrey 3D Ambient Light Rejecting Material. User s Guide

HP-2 / HP-4 / HP-6 Ceiling to Wall Inside Corner Installation Instructions Overview

3% VOLTAGE DROP. Installation Instructions for 400 Watt 24 Volt DC RGB DMX LED Power Supply SAVE THESE INSTRUCTIONS!

Platinum Club Series Treadmills. Assembly Instructions

VDM-2X1-WM & VDM-3X1-WM MONITOR WALL MOUNTS

Custom Pendant- Hardwire Assembly and Installation Instructions

Important Safety Instructions

RAIL 4 INSTALLATION INSTRUCTIONS. RM4DOD Recessed GENERAL SAFETY INSTRUCTIONS: NOTE:

LINESSE LINEAR LUMINAIRE 3 RECESSED CV2424

UR20/UR28 Ouro Site/Area Luminaire Installation Instructions

Basic Spring Motor Roller Shades

Pow-R-Feed Systems Service Manual

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

Important Safety Instructions

WARNING: Failure to follow these warnings and assembly instructions could

+ - 1a. 1b. c. 1d. 1e. Runway Suspended / Surface Cont. Run Installation. 2.0mm DIL DIL Revision - M 23/11/2018 Page 1

#4 Phillips Driver Bit 1/8, 4mm, 5.5mm & 8mm (5/16 ) Allen Wrench. Safety Glasses

LED Thin Frame Fixed Frame Screen User Guide

Butt Welder Docking Station

ADVANTUS CV1100 SERIES OV1100 SERIES OG1000 SERIES

Joiner Kit Joiner bracket (x1) Biscuit aligners (x2) Trim Flange

Instruction Sheet. VDM Series FIXED & TILT WALL MOUNT

Installation, Operation and Care Instructions. Retractable Cord Operating System

Wall Mount Assembly and Mounting Guide (55 /84 )

Tube Facing Tool.

A524 ASSEMBLY & INSTALLATION INSTRUCTIONS BELLADONNA PENDANT CASTLETON, VERMONT USA SYNCHRONICITYLIGHTING.COM Rev A 1 OF 7

INSTALLATION GUIDE MICROWAVE OVEN UPMC3084ST. MFL _00

Bionic 4 PERIMETER, CONTINUOUS RUN X3, X7

Round or Square Type IC Down Light Housing with LED Lamp for Flangeless Trims E3_L_-L_DI 1.4

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4

INSTALLATION RECOMMENDATIONS For The Con-Tech ODYSSEY Line Voltage Flexible Track System

GLASS GLOBE MOBILE LINEAR CHANDELIER

Axon Signal Unit Installation Manual

ADAPT. ABILITY. X 6.50" Example of a continuous row. Shown: hanging the fixture via threaded rods.

Transcription:

INSTALLATION INSTRUCTIONS SUPERPLANE 4 WALL MOUNT A 1035 22nd Avenue, Unit 1 Oakland, CA 94606 P 510.489.2530 E TalkToUs@alwusa.com W alwusa.com

SP4 - Safety & Warnings! 1. Read all instructions. 2. Install in accordance with national and local electrical code regulations. 3. This product is intended to be installed and serviced by a qualified, licensed electrician. 4. Do not install in wet locations. For dry and damp use only. 5. Turn off electrical power before installing or servicing fixture in any way. 6. To reduce the risk of fire and overheating, make sure all connections are tight. 7. Suitable for continuous row mounting. 8. Handle ControRoll TM lens with care! Always wear protective eyewear while handling lens! Lens may chip/crack when handled roughly. SP4 - Attention! 1. Lisez toutes les instructions. 2. Installez conformément à la réglementation du code électrique national et local. 3. Ce produit est destiné à être installé et entretenu par un électricien agréé qualifié. 4. Ne pas installer à l extérieur ou dans des endroits humides. Pour une utilisation en intérieur et sec seulement. 5. Coupez l alimentation électrique avant de évoluer le système d éclairage en aucune façon. 6. Pour réduire le risque d incendie et de surchauffe, assurez-vous que toutes les connexions sont bien serrées. 7. Peut être monté en rangée continue. 8. Manipuler l objectif ControlRoll avec soin! Portez toujours des lunettes de protection lors de la manipulation de l objectif ControlRoll. SHOCK HAZARD! May result in serious injury or death. Turn power OFF at circuit breaker prior to installation or servicing. CONTROLROLL LENS HANDLING & SAFETY! ALWAYS WEAR PROTECTIVE EYEWEAR WHILE HANDLING LENS! LENS MAY CHIP/CRACK WHEN HANDLED ROUGHLY! Ø < 3.0 in. DO NOT CREASE LENS DO NOT TWIST LENS DO NOT BEND LENS TO A DIAMETER LESS THAN 3 INCHES. SP4S Installation Guide Wall Mount 2 of 12 102-000006 - IG110218-B.0

Table of Contents Luminaire Overview 4 Diagram 4 Included Parts 4 Parts (by others) 4 Tools Required 4 Quick Specs 4 Installation 5 Single Sections 5 Joining Straight Sections 7 Joining Miter Sections 8 ControllRoll TM Lens 9 Finishing 10 Wiring Diagrams Traditional On/Off 0-10V Dimming DMX DALI Lutron LDE Troubleshooting 11 11 11 11 11 11 12 SP4S Installation Guide Wall Mount 3 of 12 102-000006 - IG110218-B.0

Luminaire Overview: Diagram 1 2" 4 13 16" 4 7 16" Included Parts SP4S Fixture ControlRoll TM Lens Fixture Brackets Wall brackets Hardware Parts (by others) 2X4 J-Box Wood Screws, #8, 1.5 long or applicable hardware to mount to surface. Wire nuts Tools Required Drill #2 phillips bit Wire strippers 1/8" Allen key Quick Specs Input Voltage / Frequency: See product label Rated Current: See engineering drawing Ambient Temperature: -4 120 F (-20 50 C) Environment: Dry and damp locations SP4S Installation Guide Wall Mount 4 of 12 102-000006 - IG110218-B.0

BER: MATERIAL: PROCESS: FINISH: UNITS: INCHES LINEAR TOL: 0.01 INCHES ANGULAR TOL: 0.1 DEGREE DRAWN BY: CHECKED BY: ENG APPR: MFG APPR: Installation: Single Sections ZONE REV. DESCRIPTION DATE APPROVED A INITIAL DRAWING MOUNTING BRACKET WITH POWERFEED MOUNTING BRACKET SAMPLE DRAWING J-BOX (BY OTHERS) 1 See Final/Record Drawings for Mounting Locations See final/record drawings for mounting locations. Install blocking or framing with consideration for alignment with wiring and mounting locations. 4 Hook fixture on wall brackets Hook fixture over wall brackets as shown. REVISIONS ZONE REV. DESCRIPTION DATE A INITIAL DRAWING MOUNTING BRACKET SAMPLE DRAWING J-BOX (BY OTHERS) 2 Install framing and J-box Install J-box (by others) to structure with applicable mounting hardware (by others) at locations per final/record drawing. 5 Rest fixture against wall Rest fixture against wall so that the fixture bracket covers wall bracket. Make sure fixture sits properly on all mounting points along the length. 3 Install wall brackets Install ceiling bracket and J-box cover to the structure using applicable mounting hardware (by others) as shown at locations per final/record drawings. Make sure all wall brackets are aligned with each other. 46 Raise Secure fixture with screws Screw in provided 8-32 screws at the bottom of the fixture bracket with 1/8 allen key. Adjust fixture for alignment if necessary. SP4S Installation Guide Wall Mount 5 of 12 102-000006 - IG110218-B.0

Installation: Single Sections 7 Remove protective film Peel the protective film on fixture. This film can be re-applied on the fixture to protect it from construction debris, dust etc. 10 Re-install heat sink Re-install heat sink. Make sure wires are not pinched between parts and heat sink is aligned with adjacent heat sink.! SHOCK HAZARD! May result in serious injury or death. Turn power OFF at circuit breaker prior to installation or servicing. DO NOT PINCH OR PUT EXCESSIVE TENSION ON WIRES while joining sections or reattaching end caps. 8 Remove heat sink for wire access Remove the heat sink marked per final drawings by unscrewing four screws. 9 Connect Wiring Pull wires into the fixture from J-box and make connections with driver wires as per wiring diagram shown on Page 11. SP4S Installation Guide Wall Mount 6 of 12 102-000006 - IG110218-B.0

Installation: Joining Straight Sections 11 Install Other Section Mount adjacent sections on wall brackets as outlined in Steps 4, 5 and 6. Make sure the two sections are aligned vertically with one another. 14 Secure internal joiner brackets Using 1/8" allen key, fasten internal brackets. 12 Connect Wiring Connect wiring quick-connects. 15 Secure fixture section to wall bracket Make adjustments to align segments if necessary and secure the section to wall bracket with provided 8-32 screws! SHOCK HAZARD! May result in serious injury or death. Turn power OFF at circuit breaker prior to installation or servicing. DO NOT PINCH OR PUT EXCESSIVE TENSION ON WIRES while joining sections or reattaching end caps. 13 Align and slide sections together Slide joining section over brackets extended from the previous section. All brackets should slide partially into joined section. Check for alignment. SP4S Installation Guide Wall Mount 7 of 12 102-000006 - IG110218-B.0

Installation: Joining Miter Sections 16 Connect wiring Bring the adjacent fixture to the ceiling and connect wiring quick-connects. 19 Install diffuser shim Install diffuser shim in slots.! SHOCK HAZARD! May result in serious injury or death. Turn power OFF at circuit breaker prior to installation or servicing. DO NOT PINCH OR PUT EXCESSIVE TENSION ON WIRES while joining sections or reattaching end caps. 17 Align and slide sections together Slide miter section over brackets extended from the previous section. All brackets should slide partially into joined section. Check for alignment. 18 Connect internal brackets Using 1/8" allen key, tighten internal connector brackets. Check joint for fixture alignment. SP4S Installation Guide Wall Mount 8 of 12 102-000006 - IG110218-B.0

Installation: ControlRoll TM Lens 20 Bring lens to fixture Raise ControlRoll lens to fixture. For longer fixture lengths, two people may be needed. Always wear protective eyewear while handling lens. Lens may chip/crack when handled roughly. 22A Press lens into lens channel With first edge of lens in lens channel, press other side of lens up toward opposite channel. 21A Pop in ControlRoll TM lens Insert one edge ControlRoll lens into lens channel. 22B Press lens into lens channel Push lens upward until it snaps into second lens channel. 21B Insert ControlRoll lens into lens channel Insert lens into lens channel. 23 Snap lens along fixture Continue pressing both sides of lens into lens channel until lens is fully installed along length of fixture. SP4S Installation Guide Wall Mount 9 of 12 102-000006 - IG110218-B.0

Installation: Finishing 24 Turn power on Turn power back on at the breaker. 26 Apply reflector paper (multi-section fixtures) Apply adhesive-backed reflector paper over open joiner sections. 25 Illuminate fixture Power fixture and check for complete illumination 27 Apply reflector paper (multi-section fixtures) Apply reflector paper over joiner openings inside extrusion. SP4S Installation Guide Wall Mount 10 of 12 102-000006 - IG110218-B.0

Wiring Diagrams Traditional On/Off L Hot N Neutral White AC 50/60Hz Green 0-10V Dimming L Hot N Neutral White AC 50/60Hz Green DIM- 0-10V DC Dimming - Grey DIM+ 0-10V DC Dimming + Purple DMX L Hot N Neutral White AC 50/60Hz Green DMX in Shield DMX in - DMX in + DMX in shield DMX in - DMX in + Clear RED DMX out Shield DMX out - DMX out + DMX out shield DMX out - DMX out + Clear White DALI L Hot N Neutral White AC 50/60Hz Green Data + Data - Data + Data - Purple Grey Lutron LDE L Hot N Neutral White AC 50/60Hz Green E2 E2 Purple E1 E1 Grey SP4S Installation Guide Wall Mount 11 of 12 102-000006 - IG110218-B.0

Troubleshooting Only a certified electrician can service and troubleshoot product field issues. Always turn main power off before servicing fixture. Full Fixture does not illuminate Ensure fixture is wired correctly and power is on. Check that circuit breaker is on and not off or tripped. Internal LED driver may be defective. Ensure no wires are pinched between parts after joining sections or re-attaching end caps. Full fixture is flickering 0-10V, DMX, and DALI Dimming Models: Ensure polarity is correct for DATA + and - connections. Swapping DATA + and - connections can cause flickering. TRIAC Dimming Models: Ensure a compatible TRIAC Forward Phase dimmer is connected to fixture. Call tech support for further information. Possible loose DATA + and - connections from fixture to 0-10V, DMX, or DALI control. Possible loose low voltage DC + or - connection from driver to LED. Call customer support. Fixture section(s) do not illuminate Possible loose low voltage DC + or - connection between LED boards or from LED driver to LED boards. Some fixtures contain multiple LED drivers. In this case, it s possible one of the drivers is defective, which will cause the LED connected to the driver not to illuminate. Call tech support. Ensure no wires are pinched between parts after joining sections or re-attaching end caps. Fixture section(s) are flickering Possible loose low voltage DC + or - connection between LED boards. Fixture does not dim 0-10V, DMX, and DALI Dimming Models: Ensure polarity is correct for DATA + and - connections. Swapping DATA + and - connections can cause flickering. TRIAC Dimming Models: Ensure a compatible TRIAC Forward Phase dimmer is connected to fixture. Call tech support for further information. Possible loose DATA + and - connections from fixture to 0-10V, DMX, or DALI control. SP4S Installation Guide Wall Mount 12 of 12 102-000006 - IG110218-B.0