MEDTRONIC CARELINK PROGRAMMER

Similar documents
Paceart Optima System

MEDICARE S OUTPATIENT PROSPECTIVE PAYMENT SYSTEM

Confidence Delivered.

R Evolut. Conf idence. Delivered. CoreValve

MVP MICRO VASCULAR PLUG SYSTEM AN OPTION FOR PERIPHERAL EMBOLIZATION CASE REPORTS

VERCISE DIRECTIONAL SYSTEMS* VERCISE NEURAL NAVIGATOR 2.1 PROGRAMMING TUTORIAL

UPDATE TO MEDICAL DEVICE CORRECTION

ATS-I USER MANUAL. Tecnoelettra srl Dal Via Vioni Dimo, S.Rocco di Guastalla (RE)

Upgrade from Medtronic Pump. Existing Bridging the Gap Patient. Upgrade from other Brand (please specify)

A Closer Look. LATITUDE NXT Alerts SUMMARY. Alerts. Red Alerts

Urgent Recall for Product Correction. Medtronic MiniMed Sure-T infusion sets*

Calibration Instruction Manual Emerson 475 Field Communicator. Manual Revision FC.2

MEDTRONIC ANNOUNCES 2010 GLOBAL HEROES

Health Care Professional Education Programmes Partnering with you to provide focused educational opportunities

MEDTRONIC ANNOUNCES 2013 GLOBAL HEROES

GLR43308 and GLR2708. Setup and programming instructions. for the 8 channel Gigalink receiver. Programming Videos

Contacts: MEDTRONIC ANNOUNCES 2011 GLOBAL HEROES. Distance Runners from Around the World Who Benefit from Medical Technology

FAQs. BIOTRONIK EHR DataSync Frequently Asked Questions. Cardiac Rhythm Management. BIOTRONIK Home Monitoring / Programmer

MAGNETIC FIELD METER Operator s Manual

THE COSMO L REMOTE CONTROL

ELECTRONIC SHEAR PIN MODEL ESP 1 & 2 INSTRUCTION MANUAL

TYPE 2 DIABETES PUMP CONSUMABLES GRANT PROGRAM

SPECTRALIS Training Guide

LEDsmart + Push Button Minute Timer Programmable between 1 minute and 30 minutes with built in multi-way control

Quick Start RSDG2000X Function/Arbitrary Waveform Generator

The ideal K-12 science microscope solution. User Guide. for use with the Nova5000

How to Guide: Controlling Blinds in C-Bus

SDG1000X Series Function/Arbitrary Waveform Generator. Quick Start QS0201X-E01A

SDG6000X Series Pulse/Arbitrary Waveform Generator. Quick Start

Tech Support Instructions for moving power on device

MEDTRONIC ANNOUNCES 2014 GLOBAL HEROES TEAM

OPERATION MANUAL MIMAKI ENGINEERING CO., LTD.

Direct gaze based environmental controls

Precision Spectra OMG

Welcome to a radically different approach to cancer treatment.

4TCD1. Digital 7-Day Programmable Timer. Installation Instructions. Tel Fax Schneider Electric (Australia) Pty Ltd

Azure XT SR MRI SureScan W1SR01

EKOHEAT Induction Heating Systems

Simplified Operation of CF-4500 FFT Comparator

QUICK START GUIDE 2.4. Voyant Health, Ltd. 35 Efal Street Petach-Tikva, , Israel

Transmission Lines and TDR

10 YEARS PROVEN PERFORMANCE

Initial Insulin Pump Funding Request

REGENERATIVE GRID SIMULATOR MODEL SERIES MODEL SERIES PRELIMINARY. Regenerative Grid Simulator. Key Features :

PRODUCT DATA. PULSE Multichannel Sound Power Type 7748 Version 1.2

EA3012 TRANSCONDUCTANCE AMPLIFIER OPERATION MANUAL

xepton 2.4 GHz Tour Guide System User manual xepton RP-1 stationary repeater

Transmitter Model EX1100, EX1100W. User's Manual

DT 9818 Waveform-Generator. Hardware Trigger Version. Operating Manual. Version 2.0. May Page 1 of 21

Davis Art Images: Create and Share Slideshows

Instruction Manual HAS3xE-IM-SW39 10/2005

ELECTROcell B10 HV-LV

Medtronic Loan Agreement: Bridging the Gap Program

ivu Series TG Image Sensor

8000 SERIES PRECISION MULTIMETER VERIFICATION AND ADJUSTMENT GUIDE

Smart Bus RRS. Quick Start Guide

Control task Robotic buggy

When logged into the account and on the Mobile Deposit Capture screen:

Physician s Manual. June VNS Therapy Programming Software Model 250 Version 11.0 Programming Computer. For Healthcare Professionals.

EG medlab. Three Lead ECG OEM board. Version Technical Manual. Medlab GmbH Three Lead ECG OEM Module EG01010 User Manual

ASC-50. OPERATION MANUAL September 2001

MAGNETIC FIELD METER Operator s Manual

User Guidelines for Downloading Calibre Books on Android with Talkback Enabled

The USB Brotherlink 4 - or Cartridge Cable

ipad SP1 Automated External Defibrillators

Heads up interaction: glasgow university multimodal research. Eve Hoggan

UCE-DSO210 DIGITAL OSCILLOSCOPE USER MANUAL. FATIH GENÇ UCORE ELECTRONICS REV1

Cable avoidance reaches a new level

Push Button Minute Timer Programmable between 1 minute and 30 minutes with built in multi-way control

FORM 8-K. MEDTRONIC INC - mdt. Filed: November 20, 2006 (period: November 20, 2006) Report of unscheduled material events or corporate changes.

SCOUT Mobile User Guide 3.0

Built from our customer s best ideas.

msfp, SFP, SFP+, and XFP Optical Transceiver

Virtual Wound Check Study Instructions: How to Upload a Photo to MyHealthConnection Using the UCHealth App

Katya. Katya for Android Instruction Manual. Updated Jan 2012

Veterinary Digital X-Ray System Quick Start Guide

Introduction to Simulink Assignment Companion Document

Sensor Array. Multi-Electrode Mapping Vest. Technical Manual

ONE TOUCH PERFECT TEMPERATURE. Introducing the digital shower range with wireless control from Mira Showers.

Nintendo 3DS XL Quick-Start Guide This guide explains how to configure your system, launch software and connect to the internet.

Safety instructions and installation

Helping you improve patient care. Welch Allyn Holter Systems

Translation of the original operating instructions Version: 11/2017

RegionFinder The perfect Use. SPECTRALIS HRA, HRA+OCT and SPECTRALIS OCT

MEGAPLEX-2100 MODULE VC-16A. 16-Channel PCM/ADPCM Voice Module Installation and Operation Manual. Notice

BIOTRONIK // Celebrating 50 years of excellence BIOTRONIK. Setting the pace, pioneering the future

P2P 2 YEAR PL-VDIO-05. Smartphone Connect IP VIDEO DOOR PHONE QUICK START GUIDE 7 VIDEO DOOR PHONE SYSTEM WITH SMARTPHONE CONNECT

Greater Flexibility in Equipment Design

GV-700 VIBE PORT. Installation and. Operating Manual

Wireless temperature controller E N RFTC-50/G

Assembly Instructions

DR General Radiography System. DR Series

Content. User Instruction - Pointoselect digital. Intended use...3 Safe usage of the device...3 Description...4

CERTIFICATE OF ACCREDITATION

Instruction Manual. Ultrasonic and Radar

CCG Referral App - Northern Ireland

Fluke 125. Getting Started. Industrial ScopeMeter

Personalised. 50p (inc. VAT) from each card sold supports this worthy charity. Christmas Cards and Calendars Up to

Silent Gliss. Control Systems

ifeel Sensor USER GUIDE SUPPLEMENT

Transcription:

MEDTRONIC CARELINK PROGRAMMER Model 2090 Programmer Software Application Supplement

Contents Introduction 5 Software feature update 5 Emergency VVI button 5 Display screen changes 6 Calibrate button 7 Built-in keyboard operation 8 Medtronic CareLink Programmer Software Application Supplement

Introduction 5 Introduction This supplement highlights the operating differences between the Medtronic Model 9790/C Programmer and the Medtronic CareLink Programmer Model 2090. Medtronic pacemakers and implantable cardioverter defibrillators (ICDs) can be programmed with either the Medtronic CareLink Programmer or the Model 9790/C Programmer. This document supplements the Software Programming Guide, device Implant manual, and Software Reference Manual provided with each device and software application. For complete information about specific device operation, please refer to the appropriate guide or manual that accompanies the software application, implantable device and programmer. Software feature update The major operating differences between the Model 9790/C Programmer and the Medtronic CareLink Programmer include: emergency VVI button display screen changes calibration button built-in keyboard Emergency VVI button The red Emergency VVI button on the display panel provides immediate access for emergency VVI pacing. (Specific parameter values are determined by each application.) For all Medtronic pacemaker applications, the Emergency VVI button is active when the [Emergency] button is displayed on screen. For some ICD applications, the Emergency VVI button is active at all times. When pressed, this button delivers VVI pacing and displays the emergency screen options. Medtronic CareLink Programmer Software Application Supplement

6 Software feature update Delivering emergency bradycardia pacing To initiate emergency pacing, correctly position the programming head over the implanted device and press the red Emergency VVI button. A message confirms programming, and emergency VVI operation begins. Delivering emergency tachyarrythmia therapy The blue deliver button used on the Model 9790/C Programmer to deliver emergency tachyarrythmia therapy is not available on the Medtronic CareLink Programmer. To deliver therapy, press the red Emergency VVI button to display the emergency screen on the programmer and select the on-screen [Deliver] button with the touch pen. For specific applications, refer to the appropriate device Reference Guide or System Reference Guide for complete instructions regarding the use of the Delivery button. Warning: The red Emergency VVI Button is disabled for the following devices: PCD, Jewel PCD, Micro Jewel II, Micro Jewel, Jewel CD, Jewel Plus, Model 7202 Jewel CD, Models 7218 and 7211, Model 7201 CD, and Jewel AF. Use the touch pen to select the on screen [Emergency] button. Display screen changes A task bar has been added at the top of the screen. It includes two new indicators: Position Head Light Array Remote View icon Refer to the Medtronic CareLink Programmer Reference Guide for complete information on these features. Additional waveform display. (This display screen change applies only to Vision software applications.) All screens display an additional waveform. For example, if a screen displays one waveform on the Model 9790/C Programmer, this screen displays two waveforms on the Medtronic CareLink Programmer. Medtronic CareLink Programmer Software Application Supplement

Software feature update 7 Figure 1. Additional display screen features of the Medtronic CareLink Programmer 1 2 3 1 Task Bar with Position Head Light Array 2 Remote View icon 3 Live Rhythm Monitor window Select Model screen For pacemaker applications, the [Nominals...] button is inactive for Vision software. Calibrate button The Calibrate button 1 is located on the Adjust button menu (when this menu is available). To add a reference signal to the waveform, place the touch pen on the Calibrate button (see Figure 2). 1 For Vision software applications. Medtronic CareLink Programmer Software Application Supplement

8 Software feature update Figure 2. Calibrate button 1 1 The Calibrate button is located on the Adjust... menu. Built-in keyboard operation The Medtronic CareLink Programmer includes a built-in keyboard which is active only when the on-screen keyboard is displayed. Tap the touch pen outside the area of the keyboard to inactivate the on-screen keyboard. When the soft keyboard is inactive, the hard keyboard is also inactive. Note: The built-in keyboard is functional only for Vision software applications that require patient data entry. Medtronic CareLink Programmer Software Application Supplement

Manufacturer Medtronic, Inc. 710 Medtronic Parkway Minneapolis, MN 55432-5604 USA www.medtronic.com Tel. +1-763-514-4000 Fax +1-763-514-4879 Medtronic E.C. Authorized Representative/Distributed by Medtronic B.V. Earl Bakkenstraat 10 6422 PJ Heerlen The Netherlands Tel. +31-45-566-8000 Fax +31-45-566-8668 Europe/Africa/Middle East Headquarters Medtronic International Trading Sàrl Route du Molliau 31 Case Postale 84 CH-1131 Tolochenaz Switzerland www.medtronic.com Tel. +41-21-802-7000 Fax +41-21-802-7900 Australia Medtronic Australasia Pty Ltd 97 Waterloo Road North Ryde, NSW 2113 Australia Technical manuals: www.medtronic.com/manuals Medtronic, Inc. 2010 220832001D 2010-11-09 *220832001*