Screening and Qualification Inspection for Coaxial Attenuators

Similar documents
FTTC05 Series LVDS TCXO/VCTCXO FOR SPACE APPLICATIONS 10M Hz to 1400MHz. ( 5 x 7 mm, SMD, 2.5 V )

FTM2 Series HCMOS/TTL OSCILLATORS FOR SPACE APPLICATIONS 0.5MHz to 160 MHz. ( 5 x 3.2 mm, SMD, 2.5 V )

RF ATTENUATORS COAXIAL DC 22 GHz DETAIL SPECIFICATION

High-Reliability and Environment Qualified Components

HIGH RELIABILITY SEMI-RIGID COAXIAL CABLE ASSEMBLIES

REVISION RECORD REV DESCRIPTION DATE 0 INITIAL RELEASE 06/24/03

( 7 x 9 mm, J-Leads, SMD, 3.3V )

Qualification Test Report Summary for the Smiths Connectors Solderless EMI Filtered Connector. STR #569 Revision N/C 2/09/09

FTTC15 Series CMOS/Clipped sinewave Output TCXO/VCTCXO. FOR SPACE APPLICATIONS 2M Hz to 100 MHz. ( 7x5 mm, 3.3 V )

CONTINUED ON NEXT PAGE..

RF, COAXIAL. HYBRID COUPLERS POWER DIVIDERS and DIRECTIONAL COUPLERS GENERIC SPECIFICATION

THERMISTORS (THERMALLY SENSITIVE RESISTORS), NTC, RANGE 2000 TO OHMS AT +25 O C WITH A TEMPERATURE RANGE OF -60 O C TO +160 O C

Features wideband coverage, DC to 6000 MHz 2 watt rating rugged unibody construction off-the-shelf availability very low cost

Solid State PIN Control Products

MAY 14 Rev B

SAW BANDPASS FILTER. ACT PART NO.: ACTF9201_2535MHz_DCC6C

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, MAGNETRON TYPE DOD-011

Bandpass Filter BPF-E16+ Surface Mount. The Big Deal Low isertion loss (1 db typical) Good VSWR (1.4:1 typical) High rejection Fast roll-off

XSIS XE7S L0 HC/ACMOS OSCILLATORS FOR SPACE APPLICATIONS 500 KHz to 125 MHz. ( 5 x 7 mm, SMD, 3.3 V )

TE 300 TCXO Series 300

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier

Features wideband, DC to 2500 MHz excellent VSWR, through entire band miniature size, SOT143 package aqueous washable ATTENUATION. (db) Flatness, Max.

Mini Circuits SMA Attenuators

SDA SMA DATA SHEET

High Power Amplifier ZHL-20W-13+ Coaxial. 50Ω 20W 20 to 1000 MHz

DC to 400 MHz (40 db Typ. Isolation up to 20 GHz)

Data Sheet SC5317 & SC5318A. 6 GHz to 26.5 GHz RF Downconverter SignalCore, Inc. All Rights Reserved

Date: November 8 th, Titre / Title HIGH RELIABILITY. RF COAXIAL CONNECTORS for SMP Lock connectors GENERIC SPECIFICATION

QUALIFICATION TEST SUMMARY REPORT ESR-9414 Qualification Type Testing of Amphenol Corporation s 2M805 Series Connector

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, MAGNETRON TYPE 8943

Typical Applications Satellite and Deep Space Radiation Tolerance Required Severe Environmental Conditions. 10 MHz 40 MHz 10, 20 MHz

50W TO220 High Power Resistors

RF Instrument Amplifier

R-1550A TEMPEST WIDE RANGE RECEIVER. R-1550A TEMPEST Wide Range Receiver

Features miniature package MCLP 3x3 mm specified to 8000 MHz, useable to MHz excellent VSWR, 1:15:1 typ. (db) Flatness

JULY 15 Rev A

Typical Performance Curves

FCC ID: A3LSLS-BD106Q. Report No.: HCT-RF-1801-FC003. Plot Data for Output Port 2_QPSK 9 khz ~ 150 khz Middle channel 150 khz ~ 30 MHz Low channel

ISO Add:2nd Floor,Building 2,G aofa Technology Park Longjing,Nanshan,Shenzhen,China.PC

United Nations Development Programme

Frequency Range MHz. Gain db. Gain Flatness ±0.9 ±1.4 db. Output Power at 1dB compression dbm

RESISTIVE POWER SPLITTERS AND DIVIDERS

OX-249 Space Qualified Oven Controlled Crystal Oscillator (OCXO)

9 Specifications. Specifications NOMINAL CHARACTERISTICS

Date: May 17 th, 16. Titre / Title HIGH RELIABILITY RF COAXIAL CONNECTORS SMP TYPE, 50 OHMS

CUSTOM INTEGRATED ASSEMBLIES

DETAIL SPECIFICATION SHEET

IFR 4000 Portable Nav/Comm Test Set

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

TVA Thermopad Series offer proven performance and significant high reliability heritage in a commercial grade product. Features and Benefits

Date: December 10 th, Titre / Title HIGH RELIABILITY RF COAXIAL CONNECTORS SMA 2.9 TYPE, 50 OHMS (FEMALE CONTACT)

Variable Attenuators (Step & Continuous)

RF Instrument Amplifier

PERFORMANCE SPECIFICATION SHEET

Electrical Specifications. MAXIMUM POWER OUTPUT (dbm) (db) (dbm)

Pulse Amplifier ZPUL-30P. Coaxial. 50Ω Non-Inverting to 700 MHz

Features 100A400AM20. 4kHz 400MHz Class A Portable Full VSWR tolerant CE & RoHS compliant High Efficiency

MAGNETIC-LATCHING DPDT HALF-SIZE CRYSTAL CAN HIGH POWER RF RELAY DC-3 GHZ

SC5307A/SC5308A 100 khz to 6 GHz RF Downconverter. Datasheet SignalCore, Inc.

CERAMIC CHIP CAPACITORS

INSTALLATION & OPERATING INSTRUCTIONS

RF COAXIAL PHASE SHIFTER SMA DC to 18 GHz DETAIL SPECIFICATION

KU-BAND OUTDOOR BLOCK CONVERTERS

Features excellent directivity, 32 db typ. excellent mainline loss, 0.65 db typ. rugged shielded case

- 01DB = 1dB, - 02DB = 2dB, - 03DB = 3dB, - 04DB = 4dB, - 05DB = 5dB, - 06DB = 6dB

TECHNICAL SPECIFICATIONS OF STORES AND DRAWINGS.

MILITARY SPECIFICATION MICROCIRCUITS, LINEAR, POSITIVE, VOLTAGE REGULATORS, MONOLITHIC SILICON

RF COAXIAL CONNECTORS, BASED ON TYPE SMP. ESCC Detail Specification No. 3402/0xx

LT DESCRIPTION DATE APPROVED

Device Type Generic Number Circuit Function 01 DG408A(x)/883B 8-Channel Analog Multiplexer 02 DG409A(x)/883B Dual 4-Channel Analog Multiplexer

Cable Type 100. CAI Certification Specification

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

Applications biasing amplifiers biasing of laser diodes biasing of active antennas DC return DC blocking test accessory. INSERTION LOSS* (db)

PART NUMBER: ACTR MHz-DCC6C-75kHz-v1.1 Frequency: MHz

This specification applies for the RMS series of Anti-Sulfurated thick film chip resistors made by TA-I. RMS 10 J T 103.

Cable Type 125. CAI Certification Specification

Flight Model (FM) Lot Acceptance Test Model (LAT) Quartz Crystal. Synthetic HiQ Quartz, SC-cut, HC-35/U 4-point

Package (**) 0 = 24 Pin Double DIP 1 = 24 Pin Flatpack 2 = 32 Pin Flatpack

Space Xtal Oscillator TE 100 XO Series 100

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

Performance Specifications. Frequency Stabilities Supply Voltage (Vs) ma ma. RF Output

Mar07 Rev B

RADOME OMNI ANTENNA GHz, 6 dbi, FOAM FILLED

RK 409. Parameters Conditions/remarks Min Nom Max Unit

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

4W Ultra Wide Band Power Amplifier 0.1GHz~22GHz

Agilent 8560 E-Series Spectrum Analyzers

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

Broadband Wireless Power Meter User s Manual

HMMC-1002 DC 50 GHz Variable Attenuator. Data Sheet

PERFORMANCE SPECIFICATION SHEET

Multi-Band Wireless Power/ VSWR Meter. PM-6000 User s Manual

HP 8560 E-Series Spectrum Analyzers Technical Specifications

PXI MICROWAVE LOCAL OSCILLATOR MODULE

Agilent 8560 EC Series Spectrum Analyzers Data Sheet

Stop Band Rejection Loss F4 - F db F db 1

Monolithic Amplifier. DC-6 GHz ERA-2+ Drop-In

N5194A and N5192A. UXG Agile Vector Adapter 50 MHz to 20 GHz DATA SHEET

NI PXIe-5601 Specifications

Operating Temperature -40 C to +85 C Storage Temperature* -55 C to +100 C RF Power Input** 0.5W at 25 C

Transcription:

Screening and Qualification Inspection for Coaxial Attenuators Level S, Based on MIL-DTL-3933 THIS SPECIFICATION AND/OR THE SUBJECT MATTER IS RESTRICTED SOLELY FOR THE USE OF EMC TECHNOLOGY, FLORIDA RF LABS AND ITS APPROVED VENDORS. ESTA ESPECIFICACIÓN Y/O SU CONTENIDO ESTÁ RESTRINGIDO PARA USO UNICAMENTE DE EMC TECHNOLOGY, FLORIDA RF LABS Y SUS PROVEEDORES APROBADOS. REV. EN DESCRIPTION - 13-3886 Initial Release A 14-0389 Add Fixed devices and change to generic TP, add three frequencies to test sample lot B 14-0787 Removed sequences and added for screening, qualification inspection & Data and samples requirements C Added excel charts to screening and qualification inspection as well as additional reference proceding appendix TP- (Excel linked Appendix) 1 of 13 REV. B

1.0 SCOPE Quality Conformance Inspection shall consist of Screening and Qualification Inspection based on MIL-DTL-3933. All samples MUST pass Screening before being subjected to Qualification Inspection. The first Qualification sample lot shall consist of 3 different attenuator values of low, middle and high attenuation values (e.g. 3dB, 6dB & 10dB) divided into equal number of devices in each test Group and Subgroup. Subsequent Qualification Inspection lots shall consist of the number of samples per attenuation value described in this document. 2.0 SCREENING (100% of test lots) 2.1 Thermal Shock: Perform thermal shock test in accordance with MIL-STD-202, Method 107, Condition B, with the exception of temperature extremes shall be -55 C and +125 C, the number of cycles shall be ten (10), and each cycle duration shall be fifteen (15) minutes. 2.2 Pre- Power Conditioning Electricals: 2.2.1 Measure and record DC resistance from center conductor to center conductor and center conductor to case Start Date 4/10/2014 End Date 4/11/2014 Lot#: 842058 & 842059 DCR 42UW03.00FQS RAB RAC RBC 1 18.37 166.21 166.93 Value 3 db 2 17.22 161.32 160.48 Tolerance 0.5 db 3 17.40 165.94 168.44 4 18.44 167.14 168.66 5 18.24 166.27 168.14 6 17.63 164.09 162.75 7 18.53 167.60 166.98 8 18.32 164.47 165.13 9 17.82 165.24 164.32 10 18.22 163.02 164.51 42UW06.00FQS SN RAB RAC RBC 1 34.46 85.70 85.71 Value 6 db 2 32.14 86.30 86.32 Tolerance 0.5 db 3 32.68 88.92 87.82 4 33.78 91.12 90.59 5 32.47 88.58 86.72 6 33.26 83.20 82.57 7 30.33 81.04 80.72 8 33.46 82.62 82.33 9 31.63 84.90 85.34 10 31.21 82.78 83.08 42UW10.00FQS SN RAB RAC RBC 1 50.51 61.19 60.10 Value 2 50.01 60.30 59.74 Tolerance 0.6 db 3 49.62 60.18 59.03 4 49.11 59.26 58.88 5 50.01 59.71 60.76 6 51.03 61.53 60.88 7 49.86 59.95 60.02 8 49.37 58.94 59.96 9 52.97 63.36 64.14 10 50.35 60.00 60.95 TP- (Excel linked Appendix) REV. B 2 of 13

2.2.2 Measure VSWR at each end (input and output) at 1.0 GHz to max product frequency in 1 GHz increments. Start Date 4/10/2014 End Date 4/11/2014 Lot#: 842058 & 842059 Tolerance 0.5 db Tolerance 0.5 db Tolerance 0.6 db VSWR DC-4 GHz 1.15 :1 VSWR DC-4 GHz 1.15 :1 VSWR DC-4 GHz 1.15 :1 VSWR 18-26 GHz 1.50 :1 VSWR 18-26 GHz 1.50 :1 VSWR 18-26 GHz 1.50 :1 2.2.2.1 Acceptance Limits: In accordance with control drawing requirements. 2.2.3 Measure and record Attenuation between ends at DC and at 1.0 GHz to max product frequency in 1 GHz increments. 42UW03.00FQS DCA 1 2.96 2 2.91 3 2.87 4 2.96 5 2.94 6 2.92 7 2.97 8 2.97 9 2.93 10 2.97 42UW06.00FQS DCA 1 6.04 2 5.77 3 5.75 4 5.77 5 5.75 6 6.03 7 5.80 8 6.07 9 5.76 10 5.81 42UW10.00FQS DCA 1 9.84 2 9.85 3 9.84 4 9.83 5 9.82 6 9.85 7 9.83 8 9.82 9 9.83 10 9.84 2.2.3.1 Acceptance Limits: In accordance with control drawing requirements. TP- (Excel linked Appendix) REV. B 3 of 13

2.3 Power Conditioning: Each end of the attenuator (input and output) shall be subjected to a direct current power level equal to the specified average power at a temperature of 75 ±5 C for a period of 48 +/-3 hours at EACH end for a total of 96 hours. Attenuators shall be terminated in a 50 load. NOTE: Direct current power level is equal to the applied voltage times current. 2.4 Post Power Conditioning Electricals: 2.4.1. Repeat step 2.2.1 (DC resistance). Start Date 4/25/2014 End Date 4/29/2014 Lot#: 842058 & 842059 DCR 42UW03.00FQS RAB RAC RBC Δ RAB Δ RAB % Δ RAC Δ RAC % Δ RBC Δ RBC % 1 18.35 166.21 166.94-0.02-0.10% 0.00 0.00% 0.01 0.01% Value 3 db 2 17.33 161.34 160.53 0.11 0.66% 0.02 0.01% 0.05 0.03% Δ RAB +/- 2.00% Ω 3 17.40 165.94 168.45 0.00-0.01% 0.00 0.00% 0.01 0.01% Δ RAC +/- 2.00% Ω 4 18.54 167.17 168.74 0.10 0.52% 0.03 0.02% 0.08 0.05% Δ RBC +/- 2.00% Ω 5 18.28 166.29 168.18 0.03 0.19% 0.02 0.01% 0.04 0.02% 6 17.84 165.24 165.05 0.21 1.18% 1.15 0.69% 2.30 1.39% 7 18.54 167.62 167.00 0.02 0.08% 0.03 0.02% 0.01 0.01% 8 18.38 164.50 165.19 0.06 0.34% 0.04 0.02% 0.05 0.03% 9 17.82 165.24 164.33-0.01-0.04% 0.00 0.00% 0.01 0.00% 10 18.27 163.08 164.56 0.05 0.26% 0.06 0.04% 0.05 0.03% 42UW06.00FQS SN RAB RAC RBC Δ RAB Δ RAB % Δ RAC Δ RAC % Δ RBC Δ RBC % Value 6 db 1 34.49 85.68 85.72 0.02 0.07% -0.02-0.02% 0.01 0.01% Δ RAB +/- 2.00% Ω 2 32.11 86.25 86.30-0.04-0.12% -0.05-0.05% -0.02-0.02% Δ RAC +/- 2.00% Ω 3 32.66 88.91 87.81-0.02-0.05% -0.01-0.01% 0.00 0.00% Δ RBC +/- 2.00% Ω 4 33.76 91.10 90.59-0.02-0.06% -0.02-0.02% 0.00 0.00% 5 32.48 88.57 86.73 0.01 0.03% -0.02-0.02% 0.00 0.00% 6 33.26 83.18 82.62 0.00 0.01% -0.01-0.01% 0.05 0.06% 7 30.31 81.01 80.71-0.02-0.07% -0.03-0.03% -0.01-0.01% 8 33.49 82.63 82.38 0.03 0.08% 0.01 0.01% 0.06 0.07% 9 31.62 84.87 85.31-0.01-0.02% -0.03-0.04% -0.03-0.03% 10 31.20 82.75 83.04 0.00-0.02% -0.03-0.04% -0.03-0.04% 42UW10.00FQS SN RAB RAC RBC Δ RAB Δ RAB % Δ RAC Δ RAC % Δ RBC Δ RBC % Value 1 50.50 61.17 60.06-0.01-0.01% -0.02-0.03% -0.04-0.06% Δ RAB +/- 2.00% Ω 2 50.02 60.28 59.71 0.00 0.01% -0.02-0.03% -0.02-0.04% Δ RAC +/- 2.00% Ω 3 49.63 60.17 59.00 0.01 0.01% -0.01-0.02% -0.03-0.05% Δ RBC +/- 2.00% Ω 4 49.14 59.28 58.89 0.03 0.07% 0.02 0.03% 0.02 0.03% 5 50.02 59.72 60.76 0.02 0.03% 0.01 0.02% 0.00-0.01% 6 50.99 61.48 60.86-0.04-0.08% -0.05-0.08% -0.02-0.03% 7 49.82 59.89 59.98-0.03-0.07% -0.06-0.10% -0.03-0.06% 8 49.38 58.92 59.96 0.01 0.02% -0.02-0.03% 0.00 0.00% 9 52.97 63.32 64.12-0.01-0.02% -0.04-0.06% -0.02-0.04% 10 50.34 59.97 60.93-0.01-0.02% -0.03-0.04% -0.02-0.03% 2.4.1.1. Acceptance limit: Delta ±2% 0r.25Ω, whichever is greater. 2.4.2. Repeat step 2.2.2 (VSWR). 2.4.2.1. Acceptance limit: Delta ±0.1 TP- (Excel linked Appendix) REV. B 4 of 13

2.4.3. Repeat step 2.2.3 (Attenuation). 42UW03.00FQS DCA Δ DCA 1 2.96 2.96 2 2.92 2.92 3 2.87 2.87 4 2.96 2.96 5 2.94 2.94 6 2.93 2.93 7 2.97 2.97 8 2.98 2.98 9 2.93 2.93 10 2.97 2.97 DELTA S11 DELTA S22 42UW03.00FQS 1000 MHz 1000 MHz 1 #VALUE! 0.00 2 0.00 0.00 3 0.00 0.00 4 0.00 0.00 5 0.00 0.00 6 0.00 0.00 7 0.00 0.00 8 0.00 0.00 9 0.00 0.00 10 0.00 0.00 42UW06.00FQS DCA Δ DCA 1 6.04 6.04 2 5.77 5.77 3 5.74 5.74 4 5.77 5.77 5 5.75 5.75 6 6.03 6.03 7 5.80 5.80 8 6.07 6.07 9 5.76 5.76 10 5.81 5.81 DELTA S11 DELTA S22 42UW06.00FQS 1000 MHz 1000 MHz 1 #VALUE! 0.00 2 0.00 0.00 3 0.00 0.00 4 0.00 0.00 5 0.00 0.00 6 0.00 0.00 7 0.00 0.00 8 0.00 0.00 9 0.00 0.00 10 0.00 0.00 42UW10.00FQS DCA Δ DCA 1 9.84 9.84 2 9.85 9.85 3 9.84 9.84 4 9.83 9.83 5 9.82 9.82 6 9.85 9.85 7 9.83 9.83 8 9.82 9.82 9 9.83 9.83 10 9.84 9.84 DELTA S11 DELTA S22 42UW10.00FQS 1000 MHz 1000 MHz 1 #VALUE! 0.00 2 0.00 0.00 3 0.00 0.00 4 0.00 0.00 5 0.00 0.00 6 0.00 0.00 7 0.00 0.00 8 0.00 0.00 9 0.00 0.00 10 0.00 0.00 TP- (Excel linked Appendix) REV. B 5 of 13

2.4.3.1. Acceptance limit: DC Attenuation Delta ±0.2 db, for Reference only, exception due to temp variable parts. 2.4.4. Percent Defects Allowed (PDA). Calculate the percent of defects from Pre to Post Power Conditioning tests. If the cumulative number of failures exceeds the PDA the entire lot shall be rejected. 2.4.4.1. Acceptance limit: 10%. Attenuators that exceed the delta limits shall be considered to have failed and shall be removed from the lot 2.5 Subgroup 1 (Temperature Variable Products only) - Three (3) sample units that have successfully undergone Screening tests. One sample per attenuation value. 2.5.1 TCA: Measure and record attenuation at DC (0 Hz) and 1.0 GHz to max product frequency in 1 GHz increments, every 20 C over the temperature range -55 C to +125 C. 2.5.1.1 Calculate, using linear regression, the slope of the curve. 2.5.2.2 Calculate TCA using the following formula: TCA = Slope/Attenuation @ 25 C Start Date 4/24/2014 End Date 4/25/2014 Lot#: 842058 & 842059 Tolerance 0.5 db Tolerance 0.5 db Tolerance 0.6 db VSWR DC-4 GHz 1.15 :1 VSWR DC-4 GHz 1.15 :1 VSWR DC-4 GHz 1.15 :1 VSWR 18-26 GHz 1.50 :1 VSWR 18-26 GHz 1.50 :1 VSWR 18-26 GHz 1.50 :1 Δ DCATolerance +/- 0.20 db Δ DCATolerance +/- 0.20 db Δ DCATolerance +/- 0.20 db 2.5.2.2.1 Acceptance limits: Nominal TCA ±0.001 db/db/ C for DC attenuation. TCA at frequency results are for Reference only. 2.6 Visual and Mechanical Inspection: Verify and record that dimensions marking and workmanship, are in accordance with specification requirements. 3.0 QUALIFICATION INSPECTION (21 SAMPLES-9 PIECES GROUP 1 AND 12 PIECES GROUP 2) Qualification Inspection tests shall be performed on twenty seven (27) samples from a lots which have previously been subjected to and passed, Screening Inspection (9 pieces per value). The Inspection lot shall be divided into two groups. Groups 1 and 2 and 3. Group 1 shall be performed on nine (9) samples (3 pieces per value) and Group 2 shall be performed on twelve (12) samples (4 pieces per value) which must include the three (3) TCA samples from Screening Subgroup1 (1 piece per value). 3.1 Group I - Nine (9) sample units from Screening lot TP- (Excel linked Appendix) REV. B 6 of 13

3.1.1 Stability of attenuation with temperature change: Measure attenuation at 1 GHz at 23 ±2 C, at 200mW (23dBm) input power and at both extremes of the operating temperature range -55 C and +100 C. S/O 138592 TP Frequency Sensitivty Max REF Only db/db/ghz Test Stage 3.1.1 Power Sensitivty Max REF Only db/db/watt Begin Date:5/8/14 Temperature Sensitivy Nom 0.003 db/db/ C End Date:5/8/14 TCA -3 db/db/c TCA Tolerance 0.001 (+/-) db/db/c Stability of Atten vs Temperature Change ( 23 dbm Input) C C C 42UW03.00FQS -55 25 100 25 C to -55 C 25 C to 100 C ATTN ATTN ATTN db/db/ C db/db/ C 1 3.05 3 2.95 0.000208333 0.000222222 2 2.92 2.87 2.82 0.00021777 0.000232288 3 3.15 3.1 3.05 0.000201613 0.000215054 Stability of Atten vs Temperature Change ( 23 dbm Input) C C C 42UW06.00FQS -55 25 100 25 C to -55 C 25 C to 100 C ATTN ATTN ATTN db/db/ C db/db/ C 1 6.21 6.01 6 0.000415973 2.21852E-05 2 6.31 6.12 6.1 0.000388072 4.3573E-05 3 6.15 5.9 5.88 0.000529661 4.51977E-05 Stability of Atten vs Temperature Change ( 23 dbm Input) C C C 42UW10.00FQS -55 25 100 25 C to -55 C 25 C to 100 C ATTN ATTN ATTN db/db/ C db/db/ C 1 10.1 10.07 9.99 3.72393E-05 0.000105925 2 10.21 10.1 10.09 0.000136139 1.32013E-05 3 10 9.98 9.91 2.50501E-05 9.35204E-05 3.1.1.1 Acceptance limit: +/-.001dB/dB/ C, for Reference only due to temp variable device and device self-heating. 3.1.2 Stability of attenuation after thermal shock: 3.1.2.1 Measure and record attenuation at DC and 1.0 GHz to max product frequency in 1 GHz increments. 3.1.2.2 Perform thermal shock per MIL-STD-202, Method 107, Condition B Temperature extremes shall be -55 C and +125 C, the number of cycles shall be five (5), and each cycle duration shall be fifteen (15) minutes. 3.1.2.3 Measure and record attenuation at 1.0 GHz to max product frequency in 1 GHz increments. 3.1.2.3.1 Acceptance Limit: In accordance with control drawing requirements. TP- (Excel linked Appendix) REV. B 7 of 13

3.1.3 Stability of attenuation after vibration and shock: 3.1.3.1 Perform vibration shock in accordance with MIL-STD-202, Method 213, and Condition I. Start Date 6/26/2014 End Date 6/26/2014 Lot#: 846169 Test Stage 3.1.3 Stability of Attenuation after Vibration and Shock Tolerance 0.5 db Tolerance 0.5 db Tolerance 0.6 db VSWR DC-4 GHz 1.15 :1 VSWR DC-4 GHz 1.15 :1 VSWR DC-4 GHz 1.15 :1 VSWR 18-26 GHz 1.50 :1 VSWR 18-26 GHz 1.50 :1 VSWR 18-26 GHz 1.50 :1 Δ DCATolerance +/- 0.20 db Δ DCATolerance +/- 0.20 db Δ DCATolerance +/- 0.20 db Post Vibration and Shock 42UW03.00FQS DCA 1 2.97 2 2.94 3 2.88 Post Vibration and Shock 42UW06.00FQS DCA 1 6.06 2 5.78 3 5.76 Post Vibration and Shock 42UW10.00FQS DCA 1 9.86 2 9.86 3 9.86 3.1.3.2 Measure and record attenuation as specified in 3.1.2.1. 3.1.3.2.1 Acceptance Limit: In accordance with control drawing requirements. TP- (Excel linked Appendix) REV. B 8 of 13

3.1.4 Stability of attenuation after peak power: Test only if specified in SCD. 3.1.4.1 Subject devices to maximum peak power (DC pulsed) per SCD for 1 hour at each end. Start Date 7/9/2014 End Date 7/9/2014 Lot#: 846169 Test Stage 3.1.4 Stability of Attenuation after Peak Power Tolerance 0.5 db Tolerance 0.5 db Tolerance 0.6 db VSWR DC-4 GHz 1.15 :1 VSWR DC-4 GHz 1.15 :1 VSWR DC-4 GHz 1.15 :1 VSWR 18-26 GHz 1.50 :1 VSWR 18-26 GHz 1.50 :1 VSWR 18-26 GHz 1.50 :1 Δ DCATolerance +/- 0.20 db Δ DCATolerance +/- 0.20 db Δ DCATolerance +/- 0.20 db 3.1.4.2 Measure and record attenuation as specified in 3.1.2.1 42UW03.00FQS 1 2 3 Post Peak Power DCA 42UW06.00FQS 1 2 3 Post Peak Power DCA 42UW10.00FQS 1 2 3 Post Peak Power DCA 3.1.4.2.1 Acceptance Limit: In accordance with control drawing requirements. TP- (Excel linked Appendix) REV. B 9 of 13

3.1.5 Sensitivity of attenuation: Calculate sensitivity of attenuation after change in frequency at 1 GHz and maximum product frequency, change in input power (at the reference power of 1 mw and maximum power of 200 mw, and change in temperature as specified in paragraph 4.7.12 of MIL- DTL-3933. S/O 138592 TP Frequency Sensitivty Max REF Only db/db/ghz Test Stage 3.1.5 Power Sensitivty Max REF Only db/db/watt Begin Date 7/9/2014 Temperature Sensitivy Nom 0.003 db/db/ C End Date 7/11/2014 Tolerance 0.5 db Tolerance 0.5 db Tolerance 0.6 db VSWR DC-4 GHz 1.15 :1 VSWR DC-4 GHz 1.15 :1 VSWR DC-4 GHz 1.15 :1 VSWR 4-12.4 GH 1.25 :1 VSWR 4-12.4 GHz 1.25 :1 VSWR 4-12.4 GHz 1.25 :1 VSWR 12.4-18 G 1.35 :1 VSWR 12.4-18 GHz 1.35 :1 VSWR 12.4-18 GHz 1.35 :1 VSWR 18-26 GHz 1.50 :1 VSWR 18-26 GHz 1.50 :1 VSWR 18-26 GHz 1.50 :1 Δ DCATolerance + 0.20 db Δ DCATolerance +/- 0.20 db Δ DCATolerance +/- 0.20 db Stability of Atten vs Frequency Stability of Attenuation vs Power GHz GHz Units Watts Watts Units 42UW03.00FQS 1 26 db/db/ghz 0.001 0.2 db/db/watt ATTN ATTN ATTN ATTN 1 2.98 3.31 0.0039879 3 3 0 2 2.96 3.33 0.0044444 2.97 2.87 0.16919615 3 3.39 2.93 0.0062799 3.27 3.1 0.26124506 Stability of Attenuation vs Temperature Change C C C 42UW03.00FQS -55 25 100 25 C to -55 C 25 C to 100 C ATTN ATTN ATTN db/db/ C db/db/ C 1 3.05 3 2.95 0.000208333 0.000222222 2 2.92 2.97 2.82 0.000210438 0.000673401 3 3.15 3.27 3.05 0.000458716 0.000897044 Stability of Atten vs Frequency Stability of Attenuation vs Power GHz GHz Watts Watts 42UW06.00FQS 1 26 Units 0.001 0.2 Units ATTN ATTN db/db/ghz ATTN ATTN db/db/watt 1 6.06 6.27 0.0013397 6.09 6.01 0.0660115 2 5.79 6.49 0.0043143 5.92 6.12 0.16976776 3 5.77 6.33 0.0035387 5.8 5.9 0.0866401 Stability of Attenuation vs Temperature Change C C C 42UW06.00FQS -55 25 100 25 C to -55 C 25 C to 100 C ATTN ATTN ATTN db/db/ C db/db/ C 1 6.21 6.01 6 0.000415973 2.21852E-05 2 6.31 6.12 6.1 0.000388072 4.3573E-05 3 6.15 5.9 5.88 0.000529661 4.51977E-05 Stability of Atten vs Frequency Stability of Attenuation vs Power GHz GHz Watts Watts Units 42UW10.00FQS 1 26 Units 0.001 0.2 db/db/watt ATTN ATTN db/db/ghz ATTN ATTN 1 9.86 10.46 0.0022945 9.91 10.07 0.0811322 2 9.87 10.52 0.0024715 9.91 10.1 0.09634449 3 9.87 10.6 0.0027547 9.9 9.98 0.04060708 Stability of Attenuation vs Temperature Change C C C 42UW10.00FQS -55 25 100 25 C to -55 C 25 C to 100 C ATTN ATTN ATTN db/db/ C db/db/ C 1 10.1 10.07 9.99 3.72393E-05 0.000105925 2 10.21 10.1 10.09 0.000136139 1.32013E-05 3 10 9.98 9.91 2.50501E-05 9.35204E-05 TP- (Excel linked Appendix) REV. B 10 of 13

3.1.5.1 Acceptance Limits: In accordance with control drawing requirements. Results are for Reference only, due to temp variable device and device self-heating. 3.1.6 Visual and Mechanical Inspection: Verify and record that dimensions, material, marking and workmanship are in accordance with specification requirements. 3.2 Group 2 - Twelve (12) sample units from the Screening lot. Samples used must include the three (3) TCA samples from Screening Subgroup1. 3.2.1 Electrical Test. Perform the electrical tests listed below at 0, 500, & 1000 hours: 3.2.1.1 Measure and record DC resistance from center conductor to center conductor and center conductor to case 3.2.1.2 Measure VSWR at each end (input and output) at 1.0 GHz to max product frequency in 1 GHz increments. Start Date 5/7/2014 End Date 5/7/2014 Lot#: Test Stage 842058 & 842059 3.2 INITIAL Tolerance 0.5 db Tolerance 0.5 db Tolerance 0.6 db VSWR DC-4 GHz 1.15 :1 VSWR DC-4 GHz 1.15 :1 VSWR DC-4 GHz 1.15 :1 VSWR 18-26 GHz 1.50 :1 VSWR 18-26 GHz 1.50 :1 VSWR 18-26 GHz 1.50 :1 Δ DCATolerance +/- 0.20 db Δ DCATolerance +/- 0.20 db Δ DCATolerance +/- 0.20 db 3.2.1.2.1 Acceptance Limits: In accordance with control drawing requirements. 3.2.1.3 Measure and record Attenuation between ends at DC and at 1.0 GHz to max product frequency in 1 GHz increments. 42UW03.00FQS DCA 4 2.96 5 2.94 6 2.93 7 2.97 42UW06.00FQS DCA 4 5.77 5 5.75 6 6.03 7 5.80 42UW10.00FQS DCA 4 9.83 5 9.82 6 9.85 7 9.83 3.2.1.3.1 Acceptance Limits: In accordance with control drawing requirements. TP- (Excel linked Appendix) REV. B 11 of 13

3.2.2 Burn-in Attenuators shall be burned-in for 500 hours at EACH end (1000 hours total) at maximum power per SCD at 75 C. Attenuators shall be terminated in a 50 load. Start Date 5/29/2014 End Date 5/29/2014 Lot#: Test Stage 842058 & 842059 Post 500 hr BI Tolerance 0.5 db Tolerance 0.5 db Tolerance 0.6 db VSWR DC-4 GHz 1.15 :1 VSWR DC-4 GHz 1.15 :1 VSWR DC-4 GHz 1.15 :1 VSWR 18-26 GHz 1.50 :1 VSWR 18-26 GHz 1.50 :1 VSWR 18-26 GHz 1.50 :1 Δ DCATolerance +/- 0.20 db Δ DCATolerance +/- 0.20 db Δ DCATolerance +/- 0.20 db 42UW03.00FQS 4 5 6 7 500 HR 42UW06.00FQS 4 5 6 7 500 HR 42UW10.00FQS 4 5 6 7 500 HR. Start Date 6/26/2014 End Date 6/26/2014 Lot#: 842058 & 842059 Test Stage Post 1000 hr BI 3.2.2.1 Repeat step 3.2.2 Tolerance 0.5 db Tolerance 0.5 db Tolerance 0.6 db VSWR DC-4 GHz 1.15 :1 VSWR DC-4 GHz 1.15 :1 VSWR DC-4 GHz 1.15 :1 VSWR 18-26 GHz 1.50 :1 VSWR 18-26 GHz 1.50 :1 VSWR 18-26 GHz 1.50 :1 Δ DCATolerance +/- 0.20 db Δ DCATolerance +/- 0.20 db Δ DCATolerance +/- 0.20 db TP- (Excel linked Appendix) REV. B 12 of 13

42UW03.00FQS 4 5 6 7 1000 HR 42UW06.00FQS 4 5 6 7 1000 HR 42UW10.00FQS 4 5 6 7 1000 HR 3.2.2.1 Acceptance limit: In accordance with control drawing requirements. 3.2.3 Visual and Mechanical Inspection: Verify and record that dimensions, material, marking and workmanship are in accordance with specification requirements. 3.2.4 Visual and Mechanical Inspection: Verify and record that dimensions, material, marking and workmanship are in accordance with specification requirements. 4.0 DATA AND SAMPLES REQUIREMENTS A certificate of conformance, variables data for VSWR and attenuation and attributes data (number of units tested, number passed) recorded by test and listing test operator and date performed, shall accompany shipments of deliverable units. Test samples shall be packaged in an anti-static bag and clearly marked as Qualification Inspection samples. Reference Document 138592 for Test Data Appendix Click for Link TP- (Excel linked Appendix) REV. B 13 of 13