INSTALLATION INSTRUCTIONS (for a sloping roof)

Similar documents
Instructions for Installation on a Pitched Roof LIGHTWAY optical tube LW 260, LW 320, LW 520, LW 760

for Flexi Sun Lite Planning the layout

for Rigid Sun Lite Planning the layout

Instructions for Installation on a Flat Roof

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

4 Position the Suntile to the x tile s position and mark the felt around the square box flange. Then remove the Suntile

A500 ASSEMBLY & INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR FLUSH MOUNT FIXTURES

Woven Leather Chandelier Large Assembly and Installation Instructions

THANK YOU FOR PURCHASING FROM HERITAGE PATIOS

SecuAnch Roof Anchor System

3/ /

INSTALLATION RECOMMENDATIONS For The Con-Tech ODYSSEY Line Voltage Flexible Track System

Custom Pendant- Hardwire Assembly and Installation Instructions

Piazzola Pergola Awning Manufacturing and installation guide

10 Octagon Cedar Gazebo Assembly Instructions

Pergola Installation Guide. When only the best will do.

INSTALLATION MANUAL STOREFRONT DOORS

Nash Chandelier Assembly and Installation Instructions

ASSEMBLY INSTRUCTION CONTENT

INSTALLATION INSTRUCTIONS FOR FLUSH MOUNT FIXTURES

Arched Top Lantern Pendant Assembly and Installation Instructions. Country of Destination: US/CN UK/EU/AUS Middle East

GROWING BETTER THROUGH DESIGN. 6ft Lean-To LEAN-TO. Assembly Instructions 04/02

ENGINEERING STRENGTH INSTAL L AT I O N M A NUAL OUR STRENGTH IS OUR STRENGTH

PORTA~TRACE. GAGNE, INC. 41 Commercial Dr. Johnson City, New York Phone: Fax: ASSEMBLY INSTRUCTIONS

CINTRALUX ALU BARREL VAULT EP 10/10

TrendWall Floor-To-Ceiling Panels Installation Instruction

MIL-STD B (SH) UPDATE

Rigid and Flex Tubular Skylights Installation Instructions

Stair Mounting Kit. Installing safety gates in modern homes can be very challenging, especially for stairs.

ROPE CHANDELIER - FRAME ASSEMBLY & INSTALLATION INSTRUCTIONS

Pergola Installation Guide

PUSH-PULL-PROPS. and accessories ROBUSTA-GAUKEL GMBH MOUNTING TECHNOLOGY &CO.KG

PLEATED SHADE ARCH INSIDE MOUNT GETTING STARTED. A few simple tools are required: STANDARD HARDWARE

KOLO SHELTER Installation Instructions Parts List

LAGGING PIPES UP TO 125 mm IN DIAMETER WITH K-FLEX TUBING

Fabric tiered drum pendant 30in Assembly and Installation Instructions

Kawasaki Mule Pro Upper Doors #06020 Installation & Operations Manual

Turn off electricity at circuit breaker or main fuse box before installation. Consult a licensed electrician if in doubt.

OPTICAL BENCH - simple type

1/4 Rubber Spacer, 26 pcs. M5-.8 Machine Screw, 26 pcs 13. Female Wire Connector, 4 pcs

INSTALLATION INSTRUCTIONS TRI-ROOF. energy for a better world

RENU PANELING SYSTEM Installation Guide PLEASE READ GUIDE COMPLETELY BEFORE ASSEMBLY. Version 1.0 ALL STATED SIZES ARE NOMINAL DIMENSIONS.

INSTALLATION INSTRUCTIONS Ceiling Light Fixture Bug Tight Light

Water Line and Water Line Assembly Gasket

TUNNELS III.

Octagon Vinyl Gazebo Assembly Instructions

Sport-Thieme Safety Aluminium Mini Training Goal

*Patent Pending. *Trademarked. Series II. Glass Conversion Kit. (888) One-Products (888)

IMPORTANT: WILL NOT FIT COUNTRYMAN MODELS

General Prisoner Transport Install Instructions PT-2-INST

Please read all warnings and instructions before beginning the installation.

Version 2016_1.1 VICTORIAN ASSEMBLY INSTRUCTIONS. Victorian Vi-23, 34, 36

Titan Series Awning Assembly and Installation Instructions

Hoops Installation Instructions for Standard (Non-Adjustable) Basketball Goals

Assembly Instructions 10 X 10 Aluminum Frame Building

GIRTS ON BACK OF BUILDING

ASSEMBLING YOUR L&L EASY-FIRE KILN

Step by Step Installation Instructions. Poly Shutters. Customer Service or visit us online at smithandnoble.com

Exterra Installation Guide

'Mutiny' Ozone Reactor Kit

Signal Mirror Installation Instructions

Installation Instructions

Vinyl Windows and Doors

Flat Style Fender Flares Front Pair. Jeep. Included in Hardware Kit:

TOOLS REQUIRED: HARDWARE INCLUDED: 13MM FLAT WRENCH FOR LEVELING THE STRUCTURE RATCHET WITH 5MM HEX BIT FOR CORNER SCREWS ON TOP TRAVERSE BEAMS

SERVICE ADVISORY SA-11

Fiber Splice Box (FSB-D) Installation Instructions

CAUTION: BEFORE INSTALLING THE LUMINAIRE, MAKE SURE THAT THE CURRENT IS CUT TO THE BOX FUSES / MAIN CIRCUIT BREAKER.

HONEYCOMB SHADES. Cordless INSIDE MOUNT. A few simple tools are required: STANDARD HARDWARE OPTIONAL HARDWARE

Assembly Instructions

*** All chrome surfaces should be cleaned using a clean damp cloth. *** No abrasive cleaning agents or materials should be used.

LEGENDS RETRACTABLE DOOR SCREENS

INSTALLATION INSTRUCTIONS 10' WIDE FRAME FRAME SIZE: 10 X 18 X 7 (2 SQUARE TUBING) STORAGE SHELTER / CARPORT

Metro Series Sauna. installation instructions

SUPERSEDED REVISION. Reasons for reissue of this instruction sheet are provided in Section 7, REVISION SUMMARY.

Santa Fe Cover INSTALLATION GUIDE. Alumawood TM Newport with MAXX Panel TM Installation Guide

Octagon Vinyl Gazebo Assembly Instructions For 10 & 12 Models

Chapter 1. Beam and Sill Plates

SKY TUNNEL COMMERCIAL INSTALLATION GUIDE ALL WORK CARRIED OUT BY THE INSTALLER SHOULD BE IN ACCORDANCE WITH LOCAL LAWS & SAFETY REGULATIONS.

method of build Komfire-75 partitioning system 75mm Steel Stud & Plasterboard Partitioning System with Square Aluminium Cover Trims KOMFORT

MANUAL MOUNTING SYSTEM FOR BITUMEN / EPDM

Ribcage Installation. Part 2 - Assembly. Back-Bone V1.06

7 X 10 X 6 SHELTER 7 X 16 X 6 SHELTER 12 X 10 X 6 SHELTER 12 X 16 X 6 SHELTER

Insulating Aluminium Windows

Install Instructions. NewAge Steel Welded Tall Locker

Universal Installation Instructions. Preparation and Safety Information. Natural Lighting by Monodraught. Dust. Scaffolding

F5513 APOGEE 30"DIA 3LTS PENDANT INSTALLATION INSTRUCTIONS WARNING

Pleated Shades with Corded Top Down / Bottom Up Option

HOUSE PARTS PACKED IN HOUSE BOX PARTS IN PLASTIC BAG (HARDWARE) PARTS IN SMALL PLASTIC BAG (FLOOR CLIPS) PARTS PACKED IN BUNDLE

CONSTRUCTION GUIDE 27ft Wide and 30ft Wide SHEEP HOUSE

VINYL CLASSIC FREESTANDING PERGOLA ASSEMBLY INSTRUCTIONS

METRIC/IMPERIAL INSTALLATION INSTRUCTIONS

REPAIR INSTRUCTIONS. Cat. No Cat. No MILWAUKEE ELECTRIC TOOL CORPORATION. SDS Max Demolition Hammer. SDS Max Rotary Hammer

SLIDING MECHANISM TROLLEY CATCH TROLLEY ASSEMBLY FLOOR GUIDE

Assembly Instructions

HQ Pole Upgrade Kit for HQ Adjustable Table and HQ QuilTable Assembly Instructions 1

LK Wall Box AX16. Design

Step by Step Installation Instructions. Poly Shutters. Customer Service or visit us online at smithandnoble.com

Installation Instructions for Zip Suspension Downlight with Remote Power and 4" Square or Round Canopy

Transcription:

INSTALLATION INSTRUCTIONS (for a sloping roof) Tubular light tunnel ALLUX 250, 350, 550 (versions ALLUX Flexi or ALLUX Plus) 1. Dome (unbreakable polycarbonate) 2. Dome fixture 3. Nut for attaching the dome 4. Roof frame with sheeting 5. Upper reflective ring 6. Tightening strip (only for Flexi tubes) 7. Lead roof adaptor (only for corrugated roofing) 8. Polyvinyl silver tape 9. Elbow Plus (from the mirror tube) 10. firm mirror tube Plus (or flexible tube Flexi) 11. Connecting ring between mirror firm tubes Plus 12. Screw for attaching the mirror tube Plus to the connecting ring 13. Bulb holder (light kit - optional accessory) 14. Ceiling reflective ring (only for tube Flexi) 15. Ceiling frame white, circular 16. Thread-cutting screw for mounting the mirror tube Plus (or for mounting the ceiling reflective ring on the Flexi tube) to the ceiling frame 17. Anchoring and screw for mounting the ceiling frame (or only mounting foam for concrete ceilings) 18. Ceiling diffuser cover white, circular 19. Double ceiling diffuser (acrylic glass) with rubber seal INITIAL COMMENTS In order to achieve the optimum use of the characteristics of the ALLUX light tunnels and maximum efficiency, the following principles must be observed during the installation: - Place the dome preferably on the southern part of the roof most exposed to the sun, pay particular attention to ensuring that you omit shaded areas - Lead the light tunnel tube in the shortest and simplest way possible (the shorter and straighter the tube, the greater the amount of light) - Mount the tube so that it is naturally tight (applies only to the flexible Flexi tube) - During installation, remove film from elements protected by film - from all parts!! (Unremoved film in an installed light tunnel may cause permanent damage to light guiding elements)

- Install according to the installation instructions In the case of non-standard installation, which is not specified in these installation instructions, contact ALLUX STAV s.r.o., phone: +420 281 865 636 email: info@allux.cz website: http://www.svetlovod.cz/en/ 1. BOTTOM PART OF THE ALLUX LIGHT TUNNEL A. Select a spot for installation of the light tunnel on the ceiling; in the case of beamed ceiling, it must be an opening between the beams. The diameter of the opening see Table 1 B. Cut an opening in the indicated location. When cutting the opening in a concrete ceiling, it is required to consult a building designer. C. Use the included clips and screws (17) to attach the ceiling frame (15) in the cut-out opening. Table 1: Type Circular opening Circular opening Circular opening of the light tunnel in the ceiling in the ceiling in the ceiling (diameter in mm) (plasterboard ceiling) (cassette ceiling) (concrete ceiling) ALLUX 250 diameter 260 mm diameter 260 mm diameter 300 mm ALLUX 350 diameter 385 mm diameter 385 mm diameter 400 mm ALLUX 550 diameter 585 mm diameter 585 mm diameter 600 mm 2. TOP PART OF THE ALLUX LIGHT TUNNEL A. Determine an area between the rafters on the inside of the roof to install the roof frame with sheeting (4). B. Cut out the opening with the required diameter in the roof - see Table 2. In the case of a roof covered with tiles, it is necessary to disassemble part of the roofing.

ATTENTION! In the case of roofs covered with: a) Tiles we also install a lead roof adaptor and foam bottom wedges (optional accessories) b) Corrugated sheet metal we will use an alu-bitumen tape (optional accessories) or perform additional sheeting Table 2: Type of the light tunnel (diameter in mm) ALLUX 250 ALLUX 350 ALLUX 550 Square opening in the roof diameter 300 mm diameter 400 mm diameter 600 mm C. Mount the light tunnel tube to the top ring (5) of the roof frame: - For firm tubes Plus: attach the prepared module of the firm tube using screws, wrap the connection using the included polyvinyl silver tape (8); - For flexible tubes Flexi: measure the length of the tube that connects the roof part with the bottom roof part, set the tube on top of the upper ring (5), wrap the connection with the polyvinyl silver tape (8) and tighten using the tightening strip (6), finish the second part of the tube with the bottom ring - for more information see section 3.2. D. Insert the roof frame together with the light tunnel tube into the opening in the roof and mount so that the condensation openings are located at the highest point. See Annex 1 of the Installation Instructions The roof steamproof film must tightly encircle the tube! E. Fit the dome (1) onto the roof frame (4) so that the mounting openings cover the protruding screws. Insert the dome fixtures (2) and GENTLY screw them on using the included nuts (3). ATTENTION! Do not clean the dome using agents containing alcohol, petrol, nitro. During the installation of the roof part and the dome, it is necessary to remove the protective film from the reflective ring (5) which is located inside the roof frame of the light tunnel. After removing the film, make sure not to make the inside (reflective) side of the reflective ring dirty.

3.1.a) FIRM MIRROR TUBE (tube PLUS) A. Remove the protective film from the light tube. During the installation, keep the inside (reflective) part clean. Connect the light tube (module 61 cm) by inserting edges into the slits. B. Tape the area of connection of the tube using the attached polyvinyl silver tape (8). C. In order to reach the desired length of the light tube (connecting the upper ring (5) with the roof frame (15), connect the appropriate number of modules (61 cm) using the connecting rings (11) and by trimming the last (bottom) module to the desired length. The connection consists in inserting the light tube into the connecting ring and screwing it on. Then, seal the connection using the polyvinyl silver tape. D. If you are using multiple modules of the tube, we recommend to make the connected tubes more sturdy by suspending them on cords attached to the roof structure (cords are not included). Attach (screw) the cord on the tube in the connecting ring (11). 3.1.b) Installation (connection methods) of the light tube Plus and the elbow Plus A. Depending on the location of the openings in the roof and the ceiling, determine the combination of light guiding parts (tube and elbow): a) elbow-tube; b) tube-elbow-tube; c) tube-elbow.

ATTENTION! Determine the angle of incline of the roof before ordering. The elbow can be bent by 0-65 degrees. B. Prepare the light tube with a certain length by connecting the correct number of modules of the Plus tube using the connection ring (11). C. Connect the opening in the roof with the opening in the ceiling using the elbow and the light tube. D. Use the polyvinyl silver tape (8) to strengthen the connection: top ring (5), elbow (9), light tube (10). 3.1.c) Installation (connection methods) of the light tube Plus and the elbow Flexi A. Depending on the location of the openings in the roof and the ceiling, determine the combination of light guiding parts (firm tube and Flexi elbow): 1) tube - Flexi elbow 2) tube - Flexi elbow - tube 3) Flexi elbow - tube B. Pull the Flexi elbow over the firm Plus tube and firmly tighten using the polyvinyl silver tape (8). C. Using the flexible elbow and the firm Plus tube, connect the opening in the roof with the opening in the ceiling. D. Use the polyvinyl silver tape (8) to strengthen the connection: top ring (5), flexible elbow and the light tube (10). 3.2. FLEXI LIGHT TUBE (flexible tube) A.. Measure the distance between the roof opening and the bottom ring (14) taking into account the bend of the tube. Cut the Flexi light tube to the desired length. Cut through the tube with a knife, separate the steel wound wire using cutting pliers.

B. Push one end of the Flexi light tube onto the upper ring (5) of the roof frame while two or three structural wrappings of the tube must be placed above the groove. C. Wrap the polyvinyl silver tape (8) three times around the connection point and the groove under the tightening strip (6). D. Put the tightening strip (6) on the groove and tighten firmly. E. Put the other end of the light tube on the bottom ring (14) and attach it using the polyvinyl silver tape (8) which must be wrapped around the ring at least three times. 4. BOTTOM PART OF THE ALLUX LIGHT TUBE A. Insert the bottom part of the Plus light tube (or the bottom ring (14) in the case of the flexible Flexi tube) into the ceiling ring (15) and attach it using screws. Attention!! Remove the protective film from the inside of the bottom and upper rings 5. OPTIONAL ACCESSORIES - Light kit (bulb holder) A. Install the light kit (13) inside the light tube 5 cm from the edge of the ceiling frame. The light kit must be attached to the bottom reflective ring into preformed openings. Thread-cutting screws are necessary for the installation. In the case of a firm Plus tube, it is also necessary to use the bottom ring with preformed openings.

B. Connect the wire from the lighting unit holder to existing electrical wiring. ATTENTION!! Such connection to the electrical wiring should be performed only by an authorised person. Only use energy efficient light bulbs (fluorescent lamps) or LEDs that emit less heat than incandescent light bulbs. otvor pro elektrický vodič = opening for an electrical wire Light bulbs are not included. otvory pro připevnění svítilny = openings for attaching the lighting unit 6. INSTALLATION OF A DIFFUSER OF THE ALLUX LIGHT TUNNEL B. Place the set of diffusers in the seal (19) into the opening in the ceiling white circular frame. C. Place the ceiling cover (18) on the roof frame (15) so that the tabs of the ceiling cover fit into the openings in the ceiling frame (15). Push and fasten by turning right or left (make sure that all tabs are fastened). 7. INSULATION OF THE TUBE A. To ensure better thermal insulation, we recommend insulating the light tube and elbow using a mineral wool slab with a thickness of no more than 50 mm. To attach the mineral wool, just use the polyvinyl silver tape (wrapped around the tube). If you use a thicker mineral wool, we recommend not to attach it to the tube, but instead to attach it from the inside as a "stack" (e.g. from OSB boards) built around the tube so that there is no load on the tube. ------------------------------------------------------------------------------------------------------------------------------------------------------------

nepřehrát/nezapalovat = do not overheat / do not ignite netlouci = do not use a hammer nepoužívat agresivní chemikálie = do not use aggressive chemicals In the case of non-standard installation, which is not specified in these installation instructions, contact ALLUX STAV s.r.o., phone: +420 281 865 636 email: info@allux.cz website: http://www.svetlovod.cz/en/

Annex 1 of the Installation Instructions Modifications of the light tunnel roof frame when mounted into sloping roof with corrugated roofing 1. Bend the three edges (upper, left and right) of the sheetmetal element (sheeting) Attention! The condensation openings must be in the upper part of the roof frame. 2. Bend the bottom edge down. 3. Attach the lead adaptor to the bottom edge. 4. Bend the edge with the attached lead adaptor to the bottom of the sheetmetal element. 5. Place the sheetmetal element (sheeting) with the lead adaptor on the tiles so that the top part is under the tiles and the bottom part (with the lead adaptor) is on the tiles. After removing the self-adhesive film from the lead adaptor, shape the adaptor on the tiles and attach firmly (this will prevent water penetration). kondenzační otvory = condensation openings