DM-5 Power Quality Analyzer

Similar documents
DM-III MULTITEST Power Quality Recorder

DM-III Multitest & DM-III Multitest F Power Quality Recorders

3196 POWER QUALITY ANALYZER. Solve All Your Power Quality Problems ISO14001 JQA-E Power Measuring Instruments

SOLAR300N Rel /01/10

Quick Start Guide AT-6000 Advanced Wire Tracer Series

Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters

Fluke 1750 Three-Phase Power Recorder

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

1587/1577 Insulation Multimeters

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Fluke Fluke-Direct.ca. Three-Phase Power Logger. Technical Data

Fluke Advanced Test Equipment Rentals ATEC (2832) Three-Phase Power Recorder

AT-7000 Advanced Wire Tracer

Fluke 3540 FC Three-Phase Power Monitor

PQA823 PQA824 Rel /03/2007

Fluke 345. Power Quality Clamp Meter. The ideal meter for commissioning and troubleshooting modern electrical loads

Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters

PQA823 PQA824 Rel /09/18

MPQ1000. Handheld Power Quality Analyzer. Automatic CT recognition. Automatic connection verification. On-board data analysis

Fluke 3540 FC Three-Phase Power Monitor

PQA823 PQA824 Rel /01/2007

METRAClip87 and 88 Clamp Multimeters

E6000 E6000. Handheld Power Quality Analyzer. Features. Functions

Fluke 1736 and 1738 Three-Phase Power Loggers

Fluke Three-Phase Power Quality Recorder Topas. Class-A compliance for the most demanding power quality tests

Fluke 370 FC Series true-rms wireless AC/DC clamp meters

Pinpoint power quality problems faster

Fluke 1587 FC/1577 Insulation Multimeters

Complimentary Reference Material

UAT-600 Series. amprobe.com

Current Clamp. 210

PQube 3 Specifications

Power supply circuit Through an external power supply unit V ac / 12 V dc. Operating temperature ºC. Humidity of operation

C.A Complete electrical network analysis at the tips of your fingers! Power Quality Monitor. Keeping up with the standards

Maximum power. Nominal voltage. Operating temperature 0 to 50ºC. Humidity without condensation 5 95 % Contamination level 2 Current input features

Fluke Three-Phase Power Recorder. Never miss capturing a disturbance - with the exclusive threshold-free measurement system, it s automatic.

Record and Analyze Power Supply Problems Simultaneously with a Single Unit The New World Standard for Power Quality Analysis

Power Quality Analyzer KEW6315

With any other power quality analyzer you re just wasting energy.

Reliable Power Meters Multipoint Power Recorder

Fluke 1732 and 1734 Three-Phase Electrical Energy Loggers

Fluke Three-Phase Power Recorder. Plug and play: Set up in minutes with selfidentifying

E6500 Power Quality Analyzer

Energy Explorer PROFESSIONAL POWER & HARMONICS ANALYSER

PQM3000R Class A network analyzer according to EN for power quality monitoring

Power Quality Analyzer Topas 2000

Network Analyzer for Low-, Medium- and High-Voltage Networks

Power Analysis Summary

METRAClip85 and 86 Clamp Multimeters

Advantages There are many diverse advantages of a portable analyzer for the user. The most important is information.

Insulation Testers and Earth Ground Testers

Analog Digital Multimeter with Insulation Resistance Measurement

1742, 1746 and 1748 Three-Phase Power Quality Loggers

Maximum power. Nominal voltage. Operating temperature 0 to 50ºC. Humidity without condensation 5 95 % Contamination level 2 Current input features

1742, 1746 and 1748 Three-Phase Power Quality Loggers

Handy and Easy to Use Power Management Support

C.A 8332 C.A Advanced Test Equipment Rentals ATEC (2832) Display your network analysis all in picture format!

Fluke 430 Series II Three-Phase Power Quality and Energy Analyzers

Wide-band Models from DC to 100 MHz

TRMS LEAKAGE CURRENT CLAMP-ON METER 565

RISH MIT 30 Analog Digital Multimeter with Insulation Resistance Measurement

MEASURING INSTRUMENTS AND TESTERS

AC/DC Current Oscilloscope Probe Model SL261

INSULATION TESTER SERIES Selection guide

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

Power Quality Testing

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

AC/DC CLAMP METER CM4371, CM4373

Power analyzers and Energy Meters Power Analyzer Type WM14-96

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

Indeks: WMXXCMM60 Advanced Industrial Multimeter

PQM4000RGW Class A DIN 192x144 power quality analyzer with Rogowski coils

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

MACROTEST G1 & G2. I'm pure technology. Touch me, please.

Pinpoint power quality problems faster

AC/DC CLAMP METER CM4370 series

Fluke MDA-510 and MDA-550 Motor Drive Analyzer

1507/1503. Insulation Testers. Technical Data. Features and benefits:

C.A 8332 C.A Display your network analysis all in picture format! OBSERVE, DIAGNOSE, MONITOR... Three Phase Power Quality Analysers

GSC57 Rel of 257/10/05

PQube 3 Specifications

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

PQM3000 Class A rack 19 power quality analyzer for CTs or current clamps

For easy-to-use loggers, look no further! Connect to a tablet, smartphone, or PC for easy, wireless data collection

PQM3000RGW Class A rack 19 power quality analyzer with Rogowski coils

TOS5300 SERIES Hipot Tester/Hipot Tester with Insulation Resistance Test

AC/DC CLAMP METER CM4370 series

Wide-band Models from DC to 100 MHz

Programmable AC Power Source Model 9801

Moving Test - MT3000

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

Investigate All Your Power Quality Problems

Energy Management. Type WM14-96 Basic Version. Product Description. How to order WM14-96 AV5 3 D PGX. Type Selection. Input specifications.

SureTest Circuit Analyzers

FLEXIBLE CURRENT PROBES

Advantages There are many diverse advantages of a portable analyzer for the user. The most important is information.

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Transcription:

amprobe.com DM-5 Power Quality Analyzer With Feature Packed Software, most Compact High Performance Power Quality Analyzer in its Class Poor power quality is costly not only can it drive up energy bills with excessive power usage, but equipment failure or damage caused by poor power quality is expensive and time-consuming to diagnose and repair. Productivity and process also suffer with faulty equipment or unscheduled outages. The new Amprobe DM-5 Power Quality Analyzer allows you to easily and quickly discover the source and magnitude of power quality issues. At half the size of previous models, the compact DM-5 brings speed and efficiency to power quality jobs ranging from routine maintenance to in-plant troubleshooting of individual machinery and power distribution panels. Built for use in even the largest facilities, the DM-5 is safety tested to meet the world s most prestigious safety standards and is rated to CAT IV 300 V, CAT III 600 V, CAT II 1000 V. DM-5 Highlights Feature packed Software Quickly analyze your recorded data to identify potential issues with data visualization. See how data relates between different visualizations. Simultaneously measures power, harmonics, waveform, power quality (voltage: 3-channel, current: 4-channel) Measures single and three-phase power system with 10 selectable wiring connection settings Test parameters voltage, current, active/reactive/apparent power, PF and frequency all on one screen Quick start mode, wiring check and auto current sensor detection for quick, accurate measurements Automatic recording with memory for up to 1,000 parameters at user defined intervals Includes thin flex current sensor with user selectable input ranges of 300 A, 1000 A, or 3000 A Energy consumption check: Trend and demand graphs for easy view Power quality events: Swell, Dip, Interruption, transients, Inrush current, and flicker Real-time remote monitoring on compatible PC and Android devices via Bluetooth communication Comes complete with measurement accessories, PC software, and large carrying case Wireless control for remote checks and adjustments Large, full-color screen with step-by-step Quick Start Guide High performance processor for accurate, detailed data recordings DM-5 Power Quality Analyzer Easy to use Software Download Suite 3.0.1.1 features a wide range of visual tools to view data quickly and easily. Multiple data visualization options allow you to quickly visualize your recorded data to identify potential issues. Amprobe info@amprobe.com Fluke Corporation, Everett, WA 98203 Tel: 877-AMPROBE (267-7623) 2018 Amprobe For detailed specifications and ordering go to amprobe.com 6007569 B

amprobe.com Full Analysis with easy to use software Quickly analyze your recorded data to identify potential issues with customizable data visualizations. Graph peak energy demand See data over an extended time frame. Using the historical graph, you can graph peak energy demand. Zoom in and out to see the data in different views. Copy and paste raw data and charts Download Suite 3.0.1.1 allows you to copy and paste data and graphs easily. Simply export raw data into an excel document or copy and paste graphs to print. Visualize data measurements separately and together See how data relates between different visualizations, view many different visualizations at once with Download Suite 3.0.1.1. Hovering the cursor above a certain time period in one visualization will cause the other visualizations to indicate the corresponding measurements automatically. Amprobe info@amprobe.com Fluke Corporation, Everett, WA 98203 Tel: 877-AMPROBE (267-7623) 2018 Amprobe For detailed specifications and ordering go to amprobe.com 6007569 B

amprobe.com Viewing Measurements Waveform Read waveforms of voltage and current per CH with a colored graph Press the indicated buttons to view real time readings. You can do this before, during or after recording. Inst / Integration / Demand Display average/min/max instantaneous values of current/ voltage/active power/apparent power/reactive power View integration values by switching screens Harmonic Analysis Check demand values with the preset target Read harmonic components of voltage and current per CH with a colored graph Configure advanced functions such as nominal Vector and Wiring Check Read vectors of voltage and current per CH on a large, color LCD screen Perform wiring checks voltages and transient limits or check for available memory by pressing the SET UP button Additional References Test leads and cord connections Quick start guide Quick Start Guide Select the recording item Select the wiring system Confirm the connections Check the test environment (1) Select the item you want to record. * The number of selected items will have effect on file size and also on max recording time. See SD Card/Saved Data (2) Select the wiring system to be measured. * Select a proper wiring system for accurate measurements. See Wiring System (3) Connect to the circuit to be tested. * Read and follow the safety precautions described in the instruction manual. (4)(5) Check the test environment. * Self-diagnosis, wiring check and detection of connected sensors will be performed in this test. * It is recommended to do this test for ensuring the testing conditions are correct. See Test Environment Check. Amprobe info@amprobe.com Fluke Corporation, Everett, WA 98203 Tel: 877-AMPROBE (267-7623) Software to control, analyze and download data is included at no additional cost. PC software includes data transfer via memory card, USB cable and Bluetooth. With the Android app, you can view measurements remotely without wearing PPC gear. (Sorry, there is no support for Apple devices.) 2018 Amprobe For detailed specifications and ordering go to amprobe.com 6007569 B

amprobe.com Key Features Real-Time Checks with Large, Full-Color Screen. During and after measurements, the on-board screen displays data graphs and values in full color for easy comparison. Additionally, the Print Screen quick-button makes it simple to save momentary readings for later comparison. Quick Setup with On-Screen Guide. A stepby-step setup guide helps ensure you capture the right measurements. Simply select the parameters to test, follow the on-screen guide for wiring configuration, and be alerted to any incorrect settings before testing begins. Wireless Control for Remote Checks and Adjustments. Adjust settings and transfer data remotely by connecting the DM-5 to compatible Bluetooth enabled Windows and Android devices. This provides added convenience and safety, allowing for easy testing modifications even when the main unit is in difficult to access locations. Pinpoint Transients Transients can cause problems ranging from simple equipment malfunction to full equipment failure. Recording data over a prolonged period can help isolate when and where infrequent transients occur, helping identify root causes ranging from nearby lightning strikes to the switching of loads. Monitor Voltage Unbalance Monitoring for unbalance with the DM-5 can help identify issues before they result in costly equipment damage. Unbalance often causes excessive overheating, leading to motor failure and other problems within distribution systems. Complete Power Quality Kit. The DM-5 comes complete with the accessories needed to quickly get to work, including light weight flex clamps with user selectable input ranges of 300 A, 1000 A, or 3000 A. Applications Harmonics Harmonics often cause tripped circuit breakers, blown fuses, irregular electrical noises and overheating of electrical systems. Use the DM-5 to identify problematic harmonics, evaluate both the magnitude of harmonic frequencies present and the amount of total harmonic distortion. Analyze Power Efficiency With the DM-5, you can simultaneously measure up to 1,000 parameters to analyze wherever excessive power loss or other power problems may exist. Capture Sags and Swells The high performance processor of the DM-5 captures sags and swells, common causes of equipment failure and irregular electrical noises. Amprobe info@amprobe.com Fluke Corporation, Everett, WA 98203 Tel: 877-AMPROBE (267-7623) 2018 Amprobe For detailed specifications and ordering go to amprobe.com 6007569 B

Specifications Features Wiring connection Measurements and parameters Voltage (rms) Current (rms) Swell / dip / interruption Power and energy Power factor Harmonics Flicker Unbalance Transient Inrush current Capacitance DM-5 Power Quality Analyzer 1P2W, 1P3W, 3P3W, 3P4W Voltage, current, frequency, active power, reactive power, apparent power, active energy, reactive energy, apparent energy, power factor (cos ø), neutral current, demand, harmonics, quality (swell/dip/interruption, transients/overvoltage, inrush current, unbalance rate), capacitance calculation for PF correction unit, flicker Range: 600.0 / 1000 V Accuracy: ±0.2% + 0.2%f.s.(sine wave, 40 Hz to 70 Hz) Allowable input: 1% to 120% of each range (rms). 200% of each range (peak) Display range: 0.15% to 130 % of each range Crest factor: 3 or less Sampling speed of voltage transient: 24 µs Input impedance: approx. 1.67 MΩ Accuracy: ±0.2% + 0.2%f.s. + accuracy of flex current sensor (sine wave, 40 Hz to 70 Hz) Allowable input: 1% to 110% of each range (rms). 200% of each range (peak) Display range: 0.15% to 130 % of each range Crest factor: 3 or less Input impedance: approx. 100 kω Range: same as Voltage (rms) Accuracy: ±1.0% of nominal voltage Threshold value: In percentage of nominal voltage value CT-53 flex current sensor (3-ch): max. 6000 kw CT-500 flex current sensor (1-ch): max. 1000 kw Active power accuracy: ±0.3% + 0.2%f.s. + accuracy of flex current sensor (PF 1, sine wave, 40 Hz to 70 Hz) Influence of power factor: ±1.0% (PF 0.5, 40 Hz to 70 Hz ) Wh: 0.00000 mwh to 9999.99 TWh VAh: 0.00000 VAh to 9999.99 TVAh varh: 0.00000 varh to 9999.99 Tvarh Display range: -1.000 to 0.000 to 1.000 Accuracy: ±1dgt against each calculated value (for sum: ±3dgt) Harmonics order (n): 1 to 50th Inter-harmonics order (n): 1 to 50th Volts: 0.0% to 100.0%, accuracy ( 3% at 100 V nominal voltage): ±10% accuracy (<3% at 100 V nominal voltage): ±0.3% of nominal voltage accuracy (1000 V range): ±0.2% + 0.2%f.s Amps: 0.0% to 100.0%, accuracy ( 10% to max. input range): ±10% + flex current sensor. accuracy (<10% to max. input range): ±1.0% + flex current sensor Watts: 0.0% to 100.0%, accuracy: ±0.3% + 0.2%f.s. + accuracy of flex current sensor (PF 1, sine wave, 50/60 Hz) THD: 0.0% to 100.0%, Phase angle: 0.0 ⁰ to ± 180 ⁰ Displayed items: Pst(1min), Pst, Plt, Max Pst, Max Plt, V, time left Measurement method: Complied with IEC 61000-4-30 and IEC 61000-4-15 Ed.2 Accuracy: Pst (max.20): ±10% according to IEC 61000-4-15 Volts: 0.00% to 100.00%, accuracy: ±0.3% at 50/60 Hz, sine wave (0.00% to 5.00% according to IEC 61000-4-030) Current: 0.00% to 100.00% Approx. 40.96 ksps (every 2.4 µs) Range: 50 V to 2200 Vdc Accuracy: ±0.5% at 1000 Vdc Range: same as Current (rms) Accuracy: ±0.4% + 0.4%f.s. + accuracy of flex current sensor Threshold value: In percentage of the measurement range Range: 0.000 nf to 9999 F, 0.000 kvar to 999 kvar General Specifications Display Display update Operating temperature and humidity 3.5inch, TFT, QVGA(320xRGBx240) Every 1 second* *There may be time lag in display update (max. 2 seconds) due to arithmetic processing. However, no time lag between the recorded data and the time stamp. 32 F to 104 F (0 C to 40 C), 85 %RH (no condensation) Guaranteed accuracy at 73 F ± 9 F (23 C ± 5 C), 85 %RH (no condensation) Operating altitude 0 to 6,561 ft (0 to 2,000 m) Pollution degree 2 Dust/water proof IP 40 Drop proof 3.3 ft (1 m) Storage temperature and humidity Power supply Battery life -4 to 140 F (-20 C to 60 C), 85 % RH (no condensation) Battery: 6 x AA 1.5 V Alkaline battery (LR6) AC power supply: AC100 V to AC 240 V, 50 Hz to 60 Hz, 7 VAmax. 3 hours (typical) Current consumption: 1.0 A at 3.0 Vdc (typical) EMC Meets EN 61326-1 Safety compliance UL/IEC 61010-1, IEC 61010-031, IEC 61010-2-030 Power quality measurement Certification Dimensions (L x W x D): Weight: Complies with IEC 61000-4-030 ed.2 Class S 6.9 x 4.7 x 2.7 in (17.5 X 12 X 6.8 cm) Approx. 2.0 lb (900 g) with batteries installed Accessories included: Test leads with alligator clips (4), US power cord, CT-53 flex AC current clamp, CT-500 flex AC current clamp, SD card, User manual, PC software, AA batteries (6)

amprobe.com Specifications Features CT-53 Flex Current Sensor CT-500 Flex Current Sensor Current ranges 300 A / 1000 A / 3000 A, AC rms 1000 A, AC rms Output voltage 300 A range: 500 mvac / 300 Aac (1.67 mv / A) 1000 A range: 500 mvac / 1000 Aac (0.5 mv / A) 3000 A range: 500 mvac / 3000 Aac (0.167 mv / A) 500 mvac / 1000 Aac (0.5 mv / A) 300 A range: 30 A to 300 A (424 Apeak) 1000 A range: 100 A to 1000 A (1414 Apeak) 3000 A range: 300 A to 3000 A (4243 Apeak) 0 to 1000 A (1850 Apeak) Accuracy (sine wave) ±1.0% (45 Hz to 65 Hz) ±0.8% ± 0.2 mv (45 Hz to 65 Hz) ±1.5% ± 0.2 mv (40 Hz to 1 khz) Phase characteristics Within ±1 ⁰ 300 A range: 30 A to 300 A (45 Hz to 65 Hz) 1000 A range: 100 A to 1000 A (45 Hz to 65 Hz) 3000 A range: 300 A to 3000 A (45 Hz to 65 Hz) 45 Hz to 65 Hz within ±2 ⁰ 40 Hz to 1 khz within ±3 ⁰ Measuring range Working voltage Max allowed input Measurable conductor size 600 Vac rms 600 Vac rms 3600 Aac continuous (45 Hz to 65 Hz) 1300 Aac continuous Max. 5.9 in (15 cm) diameter Max. 4.3 in (11 cm) diameter Head circumference 21.65 in (55 cm) 15.75 in (40 cm) Head cable diameter 0.56 in (14.3 mm) 0.33 in (8.5 mm) Cable length (head to electronics) Approx. 6.56 ft (2 m) Approx. 8.56 ft (2.7 m) Cable length (output cable) Approx. 3.28 ft (1 m) Approx. 0.66 ft (0.2 m) Output terminal Mini-DIN-6 connector Mini-DIN-6 connector 100 Ω or less 100 Ω or less 15 ma (typical) Max. 2 ma (typical) 32 F to 122 F (0 C to 50 C), 85 %RH (no condensation) Guaranteed accuracy at 73 F ± 9 F (23 C ± 5 C), 85 %RH (no condensation) 14 F to 122 F (-10 C to 50 C), 85 %RH (no condensation) Guaranteed accuracy at 73 F ± 9 F (23 C ± 5 C), 85 %RH (no condensation) -4 to 140 F (-20 C to 60 C), 85 % RH (no condensation) -4 to 140 F (-20 C to 60 C), 85 % RH (no condensation) 0 to 6,561 ft (0 to 2,000 m) 0 to 6,561 ft (0 to 2,000 m) Output impedance Current consumption (at power supply 3 V) Operating temperature and humidity Storage temperature and humidity Operating altitude EMC Safety compliance EN 61326 EN 61326 UL/IEC 61010-1, IEC 61010-2-030, IEC 61010-2-032 Measurement CAT III 600 V, Pollution degree 2 UL/IEC 61010-1, IEC 61010-2-030, IEC 61010-2-032 Measurement CAT III 600 V, CAT IV 300 V, Pollution degree 2 Certification (UL tested with DM-5) (UL tested with DM-5) Weight Approx. 2.1 lb (950 g) Approx. 0.4 lb (180 g) PC-5 AC Line Power Adaptor CC-5 Carrying Case with Magnet 100 Vac to 240 Vac rms, 45 Hz to 60 Hz 240 Vac rms Optional Accessories Rated voltage Max. input voltage Fuse Safety compliance Certification Dimensions (L x W x D) Weight AC 500 ma / 600 V min., fast-acting, Ø6.3 x 32 mm UL/IEC 61010-1 (UL tested with DM-5) Approx. 3.0 x 2.2 x 1.8 in (7.6 x 5.5 x 4.6 cm) excludes the cord and plug 5.3 X 3 X 5.4 in. (13.5 X 7.5 X 13.7 cm) Approx. 0.26 lb (0.12 kg) 14 oz (400 g) All Amprobe tools, including the Amprobe DM-5, are rigorously tested for safety, accuracy, reliability and ruggedness in our state-of-the-art Fluke test lab. In addition, Amprobe products that measure electricity are listed by a 3rd party safety lab, either UL or CSA. This system assures that Amprobe products meet or exceed safety regulations and will perform in a tough, professional environment for many years to come. Amprobe info@amprobe.com Fluke Corporation, Everett, WA 98203 Tel: 877-AMPROBE (267-7623) 2018 Amprobe For detailed specifications and ordering go to amprobe.com 6007569 B