Jørgen S. Nielsen Institute for Storage Ring Facilities, Aarhus, University of Aarhus Denmark

Similar documents
Jørgen S. Nielsen Center for Storage Ring Facilities (ISA) Aarhus University Denmark. ESLS-RF 22 (8/ ), ASTRID2 RF system 1

MAX II RF system 100 MHz technology Lars Malmgren 10th ESLS RF Meeting Dortmund September 27-28, 2006

Tutorial on Design of RF system for Indus Accelerator. Maherdra Lad Head, Radio Frequency Systems Division RRCAT, Indore

A Synchrotron Phase Detector for the Fermilab Booster

FLASH at DESY. FLASH. Free-Electron Laser in Hamburg. The first soft X-ray FEL operating two undulator beamlines simultaneously

Project of RF System for 2.2 GeV Electron Storage Ring Zelenograd SR Source.

ALICE SRF SYSTEM COMMISSIONING EXPERIENCE A. Wheelhouse ASTeC, STFC Daresbury Laboratory

Beam Instability Investigations at DELTA

RF-based Synchronization of the Seed and Pump-Probe Lasers to the Optical Synchronization System at FLASH

Low-Level RF. S. Simrock, DESY. MAC mtg, May 05 Stefan Simrock DESY

Design considerations for the RF phase reference distribution system for X-ray FEL and TESLA

Automatic phase calibration for RF cavities using beam-loading signals. Jonathan Edelen LLRF 2017 Workshop (Barcelona) 18 Oct 2017

Bioimaging of cells and tissues using accelerator-based sources

Drive Beam Photo-injector Option for the CTF3 Nominal Phase

RF System Models and Longitudinal Beam Dynamics

Calibrating the Cavity Voltage. Presentation of an idea

New apparatus for precise synchronous phase shift measurements in storage rings 1

Beam Diagnostics, Low Level RF and Feedback for Room Temperature FELs. Josef Frisch Pohang, March 14, 2011

Performance of the Prototype NLC RF Phase and Timing Distribution System *

2008 JINST 3 S The RF systems and beam feedback. Chapter Introduction

SwissFEL Design and Status

Acceleration of High-Intensity Protons in the J-PARC Synchrotrons. KEK/J-PARC M. Yoshii

1997 Particle Accelerator Conference, Vancouver, B.C., Canada, May 12-16, 1997 BNL

Using Higher Order Modes in the Superconducting TESLA Cavities for Diagnostics at DESY

Demonstration of exponential growth and saturation at VUV wavelengths at the TESLA Test Facility Free-Electron Laser. P. Castro for the TTF-FEL team

Status of the 1.5 GeV Synchrotron Light Source DELTA and Related Accelerator Physics Activities

National Accelerator Laboratory

FLASH II. FLASH II: a second undulator line and future test bed for FEL development.

Wisconsin FEL Initiative

Design and performance of LLRF system for CSNS/RCS *

Detailed Design Report

Joachim Tückmantel CERN, Geneva

Behavior of the TTF2 RF Gun with long pulses and high repetition rates

Feedback Requirements for SASE FELS. Henrik Loos, SLAC IPAC 2010, Kyoto, Japan

3 General layout of the XFEL Facility

ERLP Status. Mike Dykes

Sub-ps (and sub-micrometer) developments at ELETTRA

Nonintercepting Diagnostics for Transverse Beam Properties: from Rings to ERLs

10th ESLS RF Meeting September ALBA RF System. F. Perez. on behalf of the ALBA RF Group. ALBA RF System 1/21

EUROFEL-Report-2006-DS EUROPEAN FEL Design Study

HITACHI Proton Therapy System with Spot Scanning

Bunch-by-Bunch Broadband Feedback for the ESRF

KU-FEL Facility. Status Report. Konstantin Torgasin PhD Student Graduate School of Energy Science Kyoto University

Performance of the TTF Photoinjector Laser System

Position of the LHC luminous region

Optical generation of frequency stable mm-wave radiation using diode laser pumped Nd:YAG lasers

Femtosecond-stability delivery of synchronized RFsignals to the klystron gallery over 1-km optical fibers

Maurizio Vretenar Linac4 Project Leader EuCARD-2 Coordinator

R. J. Jones College of Optical Sciences OPTI 511L Fall 2017

Dark current Monitor for the European XFEL D. Lipka, W. Kleen, J. Lund-Nielsen, D. Nölle, S. Vilcins, V. Vogel; DESY Hamburg

The Australian Synchrotron. Crowbar Less High Voltage Power Supplies (HVPS) 7th ESLS RF meeting, Oct Karl Zingre RF Engineer

Commissioning of the ALICE SRF Systems at Daresbury Laboratory Alan Wheelhouse, ASTeC, STFC Daresbury Laboratory ESLS RF 1 st 2 nd October 2008

Accelerator Complex U70 of IHEP-Protvino: Status and Upgrade Plans

FLASH Operation at DESY From a Test Accelerator to a User Facility

Lawrence Berkeley Laboratory UNIVERSITY OF CALIFORNIA

Illinois. I Physics. Investigation of TESLA Damping Ring Kickers using the A0 Photoinjector Beam

Femtosecond Synchronization of Laser Systems for the LCLS

1.5 GHz Cavity design for the Clic Damping Ring and as Active Third Harmonic cavity for ALBA.

RF Design of Normal Conducting Deflecting Cavity

An Overview of MAX IV Insertion Devices & Magnetic Measurement System. Hamed Tarawneh On behalf of Insertion Devices Team

3 rd Harmonic Cavity at ELETTRA

Thermionic Bunched Electron Sources for High-Energy Electron Cooling

Circumference 187 m (bending radius = 8.66 m)

FLASH. FLASH Training: RF Gun. FLASH: the first soft X-ray FEL operating two undulator beamlines simultaneously. Siegfried Schreiber, DESY

Introduction to the Physics of Free-Electron Lasers

J. Jacob: Status of the ESRF RF upgrade

Analogue electronics for BPMs at GSI - Performance and limitations

CHAPTER 6 BOOSTER RF SYSTEMS

The Theta Laser A Low Noise Chirped Pulse Laser. Dimitrios Mandridis

Performance Evaluation of the Upgraded BAMs at FLASH

레이저의주파수안정화방법및그응용 박상언 ( 한국표준과학연구원, 길이시간센터 )

REVIEW OF HIGH POWER CW COUPLERS FOR SC CAVITIES. S. Belomestnykh

Model Number Guide. M= Material. S= Apperture Size. P= Options

Does the short pulse mode need energy recovery?

1-Å FEL Oscillator with ERL Beams

FLASH rf gun. beam generated within the (1.3 GHz) RF gun by a laser. filling time: typical 55 μs. flat top time: up to 800 μs

Short-Pulse X-ray at the Advanced Photon Source Overview

H. Weise, Deutsches Elektronen-Synchrotron, Hamburg, Germany for the XFEL Group

Specification of the kicker Measurement of the magnetic field inside the kicker Optimisation of the kicker impedance to 50 Status and picture of the

Beam Infrared Detection with Resolution in Time

Reference Distribution

Introduction to Synchrotron Radio Frequency System

Status of Projects using TESLA Cavities. Mike Dykes, ASTeC, Head of RF.

1550 nm Programmable Picosecond Laser, PM

SUPERCONDUCTING RF IN STORAGE-RING-BASED LIGHT SOURCES

MICROWAVE MICROWAVE TRAINING BENCH COMPONENT SPECIFICATIONS:

Infrared Single Shot Diagnostics for the Longitudinal. Profile of the Electron Bunches at FLASH. Disputation

Electro-Optic Sensors for RF Electric Fields: a Diagnostic Tool for Microwave Circuits and Antennas

Experiment-4 Study of the characteristics of the Klystron tube

Spurious-Mode Suppression in Optoelectronic Oscillators

Third Harmonic Superconducting passive cavities in ELETTRA and SLS

FLASH performance after the upgrade. Josef Feldhaus

RF test benches for electron cloud studies

Status of the MAX IV RF systems. PPT-mall 2

The low level radio frequency control system for DC-SRF. photo-injector at Peking University *

The European Spallation Source. Dave McGinnis Chief Engineer ESS\Accelerator Division IVEC 2013

The TESLA Linear Collider. Winfried Decking (DESY) for the TESLA Collaboration

Outline of the proposed JLAMP VUV/soft X-ray FEL and the challenges for the photon beamlines and optics

Lecture 08. Fundamentals of Lidar Remote Sensing (6)

200 MHz 350 MHz 750 MHz Linac2 RFQ2 202 MHz 0.5 MeV /m Weight : 1000 kg/m Ext. diameter : 45 cm

Transcription:

Jørgen S. Nielsen Institute for Storage Ring Facilities, Aarhus, University of Aarhus Denmark

What is ISA? ISA operates and develops the storage ring ASTRID and related facilities ISA staff assist internal and external users in their experiments ASTRID operated 5+5 weeks for ions and 18+15 weeks for SR in 2004 ISA is used by ~150 users/per year from from Århus (1/4), DK (1/4) and abroad (1/2)

History of ISA 1983 First ideas about storage ring in Århus 1990 First operation with ions 1991 SX-700 monochromator installed at BESSY 1993 Inauguration synchrotron-radiation source 1994 SX-700 installed at ASTRID 1996-1999 national laboratory contract undulator + 4 additional beamlines 1997 Additional laboratory space 2001 EC contract Access to research infrastructure

ASTRID as a Synchrotron Radiation Source Energy 100-580 MeV Injector: microtron 3 GHz, 10 ma, 1 µs, 0.2-10 Hz Critical energy, wavelength ε c =360eV, λ c =35Å Current 150-200 ma Emittance 140 7nm Lifetime 40-50 hours RF 105 MHz, 14 bunches, 70 kv One undulator 30 periods of 55 mm, min. gap 22 mm, first harmonic 11-59 ev 7 beamlines

ISA/ASTRID laboratory ELISA M5 M4 ExS TESLA FEL test TOILET M3 G EnS M2 M1 PULSED LASERS FS-LASER (PB) ARUPS SX-700 lab. DF X-ray microscope SGM3 Miyake SGM2 test x-ray microscope kicker RF UV-1 undulator ASTRID e-cooler septum UV1 33 degree TESLA 40 degree neutral beam detektion SEPARATOR EBIS SEP II (LHA) RING- WORKSHOP SX700 SGM1 10 m POSITRONS microtron

Typical current and lifetime 220 200 Electron Run 2003/2 100 90 Current [ma] 180 160 140 120 100 80 60 40 80 70 60 50 40 30 20 Lifetime [hour] 20 10 0 11-10-2003 13-10-2003 15-10-2003 17-10-2003 19-10-2003 21-10-2003 23-10-2003 25-10-2003 0 BeamCurrent_slow _2 BeamCurrent_tau10_2

The ASTRID RF system 105 MHz system One cavity Copper-plated Coaxial TEM cavity 20 kw tube based (tetrode) FM transmitter The bandwidth has been increased resulting in a lower maximum output (~8 kw) Standard amplitude loop Standard cavity tuning loop Fast feedback loop Which we are very dependent on

The ASTRID RF system Rohde&Schwartz SMY01 104.95 MHz + phase modulation Amplitude loop Fast feedback loop Attennuator Phase shifter Combiner PreAmp +40 db, 10 W FM transmitter +36 db, 10 kw Amplitude detector Manual or closed loop -5-55 db -150 +40 Cavity Tuning loop Splitter Phase comparison

RF power at Injection Want low RF voltage at injection Inject (pulsed) DC beam from microtron Induce strong synchrotron oscillations => poor capture efficiency Improved lifetime Too high RF power => shorter bunch => increased Touschek scattering Need enough RF power to overcome beamloading Increase power as current increase Finding the balance! Plunger and RF power during a fill Beam Current [ma] Beam Current Plunger1 RF pow er Plunger2 200 195 72 190 70 185 68 180 66 175 64 170 62 165 60 160 155 58 150 56 145 54 140 52 135 50 130 48 125 46 120 44 115 42 110 40 105 38 100 36 95 90 34 85 32 80 30 75 28 70 26 65 24 60 22 55 20 50 18 45 16 40 14 35 12 30 10 25 20 8 15 6 10 4 5 2 0 0 12:50 12:55 13:00 13:05 13:10 Plunger / RFpower

Fighting the beamloading Fast Feedback Loop Pickup the cavity voltage and feed it back to the cavity in opposite phase. This way any beam induced voltage is counteracted Problem: Can only achieve perfect in opposition for one frequency Needs to have a small group delay to have a large bandwidth

Fast Feedback Loop Principle From amplitude loop Attennuator Phase shifter Combiner +40 db, 10 W +36 db, 10 kw -5-55 db -150 +40 Splitter To amplitude loop Reference: A. Gamp, Servo Control of RF Cavities under Beam Loading CERN 92-03, 1992 F. Perez et.al., Fast Feedback Loop for Beam Loading Compensation in the ANKA Booster Proc. EPAC 2000, Vienna, Austria, p 1996

Benefits Fast Feedback Loop Very effective to fit beamloading Cheap: Phase Shifter, Variable gain amplifier/attenuator, more low power Problem: Can only achieve perfect in opposition for one frequency Needs to have a small group delay to have a large bandwidth

Cavity Voltage with Fast Loop Fast Feedback Loop OFF Fast Feedback Loop ON

Accumulation 180 Accumulation Limit Vs. Fast Loop Gain fixed RF voltage (2.4 'kw') 160 Accumulation Limit [ma] 140 120 100 80 60 40 20 0-25 -20-15 -10-5 0 5 10 15 20 25 d:\users\jsn\accphys\e-beammeas\rfmeas\fastloop\accumlimitvsffg_040920 gffldbm 21-09-2004 14:15:34 Fast Feedback Gain [dbm]

Beam drop-out CRE31FPW CRE31RPW CRE31DPW50 CRE31DET CRE31PLP1 CRE31PLP2 Power [dbm] 74 72 70 68 66 64 62 60 58 56 54 52 50 48 46 44 42 40 38 36 34 32 30 28 26 24 22 20 18 16 10:18 10:19 10:20 10:21 10:22 10:23 10:24 10:25 10:26 62 60 58 56 54 52 50 48 46 44 42 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0-2 -4 Plunger Pos [%], Cavity Detector [*10]

Why is the Beam dropping out? Good question, which we would very much like to know the answer to. Is it because the Fast Loop is ringing, or is the ringing just because the detuning is so large when the beam drops out? At lower Fast Feedback Gain, we see the beam drop-out without the fast loop ringing. Why the large variation in forward and reverse power? Is it a signature of the fast loop working, or is it a problem? Could we get some warning? Power [dbm] 74 72 70 68 66 64 62 60 58 56 54 52 50 48 46 44 42 40 38 36 34 32 30 28 26 24 22 20 18 16 10:28 10:29 CRE31FPW CRE31RPW CRE31DPW50 CRE31DET CRE31PLP1 CRE31PLP2 10:30 10:31 10:32 10:33 10:34 10:35 46 44 42 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0-2 -4 Plunger Pos [%], Cavity Detector [*10]

Modulation of Forward Power Just after a pulse from the microtron, we see a strong modulation on the forward (and reverse) power We believe that the modulation is at the synchrotron frequency The modulation period gets longer with more current We only see it with the Fast Feedback Loop on Partly induced by the kicker Could be due to a small modulation of the cavity voltage (induced by the beam), which is strongly amplified by the Fast Loop Voltage Accumulation, I=72 ma 0.00 Cav.Mon. Forward Pickup 0.07 0.06 0.05 0.04 0.03 0.02 0.01 0.00-0.02 0 200 400 d:\users\jsn\accphys\e-beammeas\rfmeas\040902-rfmonmeas\cavmonmeas_040906 glt027 22-09-2004 10:56:59 Time [µs] Data from 040906-0.01

Modulation of Forward Power Accumulation, I=72 ma Cav.Mon. Forward Pickup 0.07 0.06 0.00 0.05 0.04 Voltage 0.03 0.02 0.01 0.00-0.02 0 200 400 d:\users\jsn\accphys\e-beammeas\rfmeas\040902-rfmonmeas\cavmonmeas_040906 glt027 22-09-2004 10:56:59 Time [µs] Data from 040906-0.01

Forward Power Variation With Amplitude Loop off, we see a change in Forward Power when scanning the RF frequency across the cavity resonance True or not? (crosstalk in the directional couplers?) Properly due to back reflection from the transmitter due to lack of circulator Problem or not? Maybe increases the fast loop off resonance power Power [dbm] 60 55 50 45 40 35 Forward and Reflected Power vs. Cav. Freqeuncy for OPEN amplitude loop, Fast Feedback Loop OFF No Beam Forward Power [dbm] Return Power [dbm] Cav. Detector [a.u.] 3.5 3.0 2.5 2.0 1.5 1.0 0.5 Cav. Detector [a.u.] 30 0.0-250 -200-150 -100-50 0 50 100 150 200 250 d:\users\jsn\accphys\e-beammeas\rfmeas\fpw,rpw,detectorvscavfreq_040927 gfflcableoff 27-09-2004 15:56:38 Cavity Frequency [khz]

60 Forward and Reflected Power vs. Cav. Freqeuncy for OPEN amplitude loop, Fast Feedback Loop OFF No Beam 3.5 55 3.0 Power [dbm] 50 45 40 Forward Power [dbm] Return Power [dbm] Cav. Detector [a.u.] 2.5 2.0 1.5 1.0 Cav. Detector [a.u.] 35 0.5 30 0.0-250 -200-150 -100-50 0 50 100 150 200 250 d:\users\jsn\accphys\e-beammeas\rfmeas\fpw,rpw,detectorvscavfreq_040927 gfflcableoff 27-09-2004 16:32:56 Cavity Frequency [khz]

The future of ISA? M4 M5 ExS ASTRID 2000 TESLA FEL test ELISA TOILET M3 G EnS microtron M2 M1 PULSED LASERS FS-LASER (PB) ARUPS SX-700 lab. DF X-ray microscope SGM3 Miyake SGM2 test x-ray microscope kicker RF UV-1 undulator ASTRID e-cooler septum UV1 33 degree TESLA 40 degree neutral beam detektion SEPARATOR EBIS SEP II (LHA) RING- WORKSHOP SX700 SGM1 10 m POSITRONS microtron

Conclusions Shown you ASTRID and its RF system Shown you our Fast Feedback Loop Shown you some issues, which we believe are part of the limitations to the attainable current

Minimum Fast Loop Gain for stable Beam Vs. Beamcurrent 25 20 15 Fast Loop Gain [dbm] 10 5 0-5 -10-15 -20-25 0 20 40 60 80 100 120 140 160 Beamcurrent [ma] d:\users\jsn\accphys\e-beammeas\rfmeas\fastloop\accumlimitvsffg_040920 glosslimit 27-09-2004 16:59:13