VBRC 4. Radio Communicator. Installer Manual

Similar documents
VBRC 5. Radio Communicator. Installer Manual

Dual-band radio transmitter T10, Т10С T10U, T10UC

smraza Getting Start Guide Contents Arduino IDE (Integrated Development Environment)... 1 Introduction... 1 Install the Arduino Software (IDE)...

MIDLAND PROGRAMING G14

INSTALLATION & OPERATION MANUAL

USB Multifunction Arbitrary Waveform Generator AWG2300. User Guide

Instruction Manual ABM HART Gateway Software. Instruction Manual Revision A.1

instruction manual for Open LRS New Generation

INDEX...2 INTRODUCTION...3 IMPORTANT NOTES...3 INSTALLING THE SOFTWARE...3 ST-965 PROGRAMMING SOFTWARE...6

Quick Start. Precis-BX305. Precise GNSS RTK Board.

GSM-900 Contact ID Cellular Backup System Installation Manual

Micro Fox PicCon Manual

Handbook. Antenna Rotator Controller

DragonLink Advanced Transmitter

WIRES-X Portable Digital Node Function. Instruction Manual

TEK-TROL HART GATEWAY SOFTWARE. Operating Instruction Manual.

Interface Genius Modem Instruction Manual v1.2.4

Micro Wizard Instructions

INDEX...2 INTRODUCTION...3 IMPORTANT NOTES...3 INSTALLING THE SOFTWARE...3 ST-965 PROGRAMMING SOFTWARE...6

DJT RC Transmitter Module 2.4 GHz Two-Way Series

ROTATING SYSTEM T-12, T-20, T-50, T- 150 USER MANUAL

AT-D868UV CodePlug Programming Guide

RTK Base Station Configuration and Utilities. Table of Contents

BRB900 GPS Telemetry System August 2013 Version 0.06

Getting Started with TrangoLink

R5 RIC Quickstart R5 RIC. R5 RIC Quickstart CONTENTS. Saab TransponderTech AB. Appendices. Project designation. Document title

Hytera. PD41X Patrol Management System. Installation and Configuration Guide

Game Genie Save Editor for PS3

Antenna and Propagation

isys-4004 GUI interface - V2.1 Power up Initialize Peripheral Start Measurement YES LED flashes red Object available LED blinking

MANUAL DGT CAÏSSA SYSTEM

AT-D868UV CodePlug Programming Guide

NetPage Network Wireless Paging System (POCSAG) NP-14 Series. Operation Manual CCW

Milli Developer Kit Reference Application Published on Silver Spring Networks STAGE (

PILOT-FI NEW. Pilot-FI Field Interface Operator s Manual

"Terminal RG-1000" Customer Programming Software. User Guide. August 2016 R4.3

ET Water SmartWorks Panel Installation Guide

Interface Manual Tank Level Float Stick System

LINKS1000CF INSTALLATION MANUAL Version 3.O

eguard EG2233, EG3333, EG3355, EG3388 & EG8406: Installation and Set-up Procedures Tx 2200 and Rx 4200 Boards

User Manual EnOcean V 0.1

Using the Dragon NaturallyMobile Recorder

RigExpert TI-7 USB Transceiver Interface User s manual

B & D Enterprises 1P repeater controller pg 1 INTRODUCTION:

WIRES-X Portable Digital Node Function. Instruction Manual

BR2 Lap Beacon Manual

SMR5000F. User Manual. Smart Radio Data Repeater. Web Site: P.N.: Book 092

Bellman BRUGERVEJLEDNING. Fyrtårn Flash BE1441

Using the USB2.0 camera and guider interface

ANI-F-VX. Multi-Format ANI Encoder. Manual Revision: This manual & product supports the following radios:

INSTRUCTION MANUAL VHF FM TRANSCEIVER TK-7102H UHF FM TRANSCEIVER TK-8102H KENWOOD CORPORATION B (M)

RPS-9000 Programming Software for the TYT TH-9000

INSTRUCTION MANUAL IP REMOTE CONTROL SOFTWARE RS-BA1

XLR PRO Radio Frequency (RF) Modem. Getting Started Guide

Faculty of Electrical & Electronics Engineering BEE4233 Antenna and Propagation. LAB 1: Introduction to Antenna Measurement

era, eric, era-lora, eric-lora & eric-sigfox Evaluation Board with GNSS

Installation instructions

Four Simple Steps to Get Started

TX4400 UHF CB RADIO INSTRUCTION MANUAL TX4400 INSTRUCTION MANUAL PAGE 1

Astra-R Kit Wireless Alarm System Operation Manual

WBT900. User s Manual. 900 MHz Wireless BACnet MSTP Radio. Page 1

Version 9.1 SmartPTT Monitoring

TX CONTROLLER Model EM-IP Quick Start Guide

TECHNICAL INFORMATION BULLETIN

MINIMUM SYSTEM REQUIREMENTS

Portable Repeater Controller. Instruction Manual for firmware version 1.0

MBD-8F Automatic Antenna Switch Controller

Programming Instructions for: Kenwood TK-780, 880, 980, 981 (Version 2) W/ KCT-19 Option Connector For use with: Pyramid Communications Model

Objectives: Learn what an Arduino is and what it can do Learn what an LED is and how to use it Be able to wire and program an LED to blink

Using the 9XR Pro for More than Eight Channels

SV613 USB Interface Wireless Module SV613

Installation guide. Activate. Install your TV. Uninstall. 1 min 10 mins. 30 mins

WDMX-512. user manual

YCE13. Dealer PC Programming Software Reference Manual. Attention!

Panther. Installation instructions. Receivers PN-RX-MN5 (PN-R8-1) PN-RX-MN5E (PN-R8-10) PN-RX-MD11 (PN-R8-6) PN-RX-MD11E (PN-R8-11)

LincView OPC USER GUIDE. Enhanced Diagnostics Utility INDUSTRIAL DATA COMMUNICATIONS

BridgeCom Systems D Centimeter DMR and Analog Handheld Transceiver

GPS Evaluation Kit EVA1035-H

TO.GO 2VA TO.GO 4VA TO.GO 2AS TO.GO 2A TO.GO 2AK TO.GO 4AK TO.GO 2QV TO.GO 4QV TO.GO 4ASE PROGRAMMING GUIDE

BFoxCon Manual. Version 0.2 October 30, 2017

JEM Radio II Operation Guide. Manual P/N M Victor Place Colorado Springs, Colorado

Quick Start Guide. P-TEC Gotthard

Testing Motorola P25 Conventional Radios Using the R8000 Communications System Analyzer

C94-M8P Application Board Setup Guide

IG-2500 OPERATIONS GROUND CONTROL Updated Wednesday, October 02, 2002

Topcon Receiver Utility: GNSS Receiver Firmware Update Process. Oscar R. Cantu

Lesson 3: Arduino. Goals

Installation & Quick Start Guide AIT2000 Class B AIS Transponder

AT-D868UV CodePlug Programming Guide

ANI-F-KW1. Multi-Format ANI Encoder For Kenwood Radios. Manual Revision: Covers Software Revisions: ANI-F: 1.

Contents. Chapter 1 Brief Introduction of K9 series Chapter 2 K9 series mainframe The appearance of mainframe Interface...

PC Tune PC Tune Test Procedures for 5100 Series Portable Radios

MicroFox2 Manual. Version 0.5 August 28, 2017

Repeater R-IP12. (Version v ) User Manual

OEM WIRELESS DIALLER INSTALLATION & USER MANUAL. (Product No )

HL 670 Data / Impulse Transmitter set User Manual. Version 07/2010

CTRX Graphene and Graphene+ Quick Startup guide for (140416) Rev. 1.0

JUMA PA1000 Linear Amplifier User Manual

Introduction to FLDIGI Karl Frank, W2KBF

GPRS-T2. GPRS/SMS Reporting Module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

Transcription:

VBRC 4 Radio Communicator Installer Manual 17 December 2014

CONTENT 1. INTRODUCTION...3 2. SYSTEM STRUCTURE...3 3. SYSTEM PROGRAMMING WITH PC SOFTWARE...5 4. TROUBLESHOOTING...6 5. FIRMWARE UPGRADE...7 6. VBRC-4 LED SIGNALS...8 7. TECHNICAL DATA...8 2

1. INTRODUCTION VBRC4 communicator is ideal solution for installation places where radio communication infrastructure is already built. By means of the device immediate alarm transmission is guaranteed without any additional operation cost. Other main advantage is that the device is independent from any service provider. According to device type the VBRC4 can be connected to the serial port / telephone line connector of the alarm control panel. Although the communication is one-way, even so it is stable and reliable due to multiple event sending to monitoring station. To use the highest range of provided functions please read carefully the Installer Manual. For the confident programming and secure usage please keep all warnings in Installer Manual, with highly focusing to security directions. 2. SYSTEM STRUCTURE VBRC-4 communicator is based on the TR48 UHF radio transmitter. The VBRC-4 is able to receive the telephone communication of the control panels with its Telco decoder and forward the events via its radio. The Telco interface can be used standalone, or with external telephone line, so communication is also possible through telephone line. The two-way Telco connection between the communicator and the control panel ensures reliable reporting and can be used with the most of the control panel manufacturers. VBRC-4 is able to receive communication from some control panel types (SECOLink, Alpha) through serial port. Additionally it sends 2 inputs status and test events. As it uses a one-way radio, the VBRC-4 communicator sends every report multiple times, in packages. Each package contains the events more times (3 by default), and also, the packages are sent more times (3 by default). Every event has a unique identifier encoded, which helps the monitoring station to decide, whether it is a new event, or a resend/repeat of a previous one, so that it will receive the event only once. 3

The System ID of the target monitoring station can be set (1..15) according to the reception pattern of the repeater network. This way the routing of the radio transmissions can be set, and also it can be used to avoid unwanted duplicate receptions at overlapping reception areas, thus decreasing network traffic. BNC antenna connector Connectors description +12V (Red, 1) Positive power supply Note.: Use at least 1,5 A capacity power supply. GND (Black, 15) Negative power supply INPUT 1 (Green, 2) External contact input VBRC-4 Radio Transmitter INPUT 2 (Orange, 3) External contact input LINE-T (Yellow, 4) External telephone line LINE-R (White, 5) External telephone line PANEL-T (Brawn, 6) CP telco communicator LED VGA connector for - installation - programming PANEL-R (Blue, 11) CP telco communicator Serial RX (13) For connecting SECOLink, Alpha alarm control panels. Serial TX (14) For connecting SECOLink, Alpha alarm control panels. Note: Different cable types are needed for usage of VBRC-4 through telephone line and serial port (with SECOLink, Alpha control panels). For the radio it is recommended to install a separate antenna with proper ground point. If used with a rubber antenna, connected directly to the radio antenna terminal, the transmissions can disturb the telephone communication. This problem may not be noticed immediately, but it may cause communication problems in the future. Note: It is not recommended to use rubber antenna in any installation. 4

3. SYSTEM PROGRAMMING WITH PC SOFTWARE VBRC-4 module programming is allowed through serial port. Please use Eni-Term software for programming. The programming steps are the following: 1. By means of VUP cable and mini USB cable, connect the VBRC-4 module to the programming PC (for serial programming). 2. Please start Eni-Term software. 3. Choose the ET (settings) file for programming: - VBRC_4_v1.00.et VBRC-4 module programming 4. In Communication / Port Settings menu set the communication port / IP address for programming. 5. By clicking to Communication / Read Data menu you can read settings from device. Note: During data reading (and sending) VBRC-4 firmware version can be checked. 6. Please execute the required settings in Eni-Term software. Note: The software functions are shown in Eni-Term help menu. 5

7. Click to Communication / Write Data menu to send the modified settings to device. Note: During data reading (and sending) VBRC-4 firmware version can be checked. 4. TROUBLESHOOTING TROUBLE: Any abnormal operation in functions during the usage of the device. SOLUTION: Firmware upgrade with the newest firmware file usually solve these kind of problems (see Firmware update part in manual). TROUBLE: There is no connection between programming PC and VBRC-4 module (during serial programming). SOLUTION: Check the cable plugging in PC side. In programming PC Control Panel / Hardware / Device Manager application you can check which COM port appears / disappears in device list during plug / unplug programming cable (with connected VBRC-4). Please check whether COM port setting is correct in programming software. TROUBLE: No communication is received from alarm control panel / comm. trouble. SOLUTION: Check, that the alarm control panel is set to DTMF (Tone) dial mode, communication should be enabled, there should be added phone number a client account, additionally Contact ID (Full) format should be selected. In some control panels might be required to disable 'telephone line monitoring' and 'wait for dial tone' options. It may help if you connect 1K resistor parallel to control panel TIP / RING connector. TROUBLE: No serial communication with Paradox Esprit control panel. SOLUTION: Serial connector of Paradox Esprit control panels only works if the PGM functions are not used. 6

TROUBLE: Communication between radio transmitter and Enigma receiver is unstable. SOLUTION: There should be at least 7 signal level at Enigma receiver side. If the signal level is lower, antenna position or antenna type should be modified. If it doesn't help radio repeater unit might be required. 5. FIRMWARE UPGRADE It is recommended to upgrade regularly device firmware to use new functions and eliminate possible bugs. Firmware upgrade can be done by the following steps: 1. Get the latest firmware files from your distributor (VBRC-4). 2. Save settings from the VBRC-4 with Eni-Term software (please check 3. System programming with PC software chapter). 3. Start VB Uploader program for firmware upgrade. 4. Choose item (VBRC-4) for upgrade (1. STEP), then NEXT. 5. Choose the proper firmware file for upgrade (2. STEP), then NEXT. 6. Choose the COM port where VBRC-4 is connected (3. STEP), then NEXT. 7. Upgrade process can be started with START button. 7

8. A Do not forget to send back the saved VBRC-4 settings at the end of the upgrade (please check 3. System programming with PC software chapter). 9. To use new functions it might be required to get the latest Eni-Term software with the newest ET (setup) files please download and use newest version. 6. VBRC-4 LED SIGNALS 2 quick red LED flashings pause 2 quick red LED flashings = Communicator is ready to use, no external telephone line 1 quick red LED flashing pause 1 quick red LED flashing = Communicator is ready to use, external telephone line is connected properly Red LED lights continuously = During serial programming Yellow LED flashes = When communication is received Yellow LED blinks continuously = Low power supply voltage 7. TECHNICAL DATA Product VBRC-4 Power supply 12 V DC Maximum current consumption 1.5 A Operating frequency UHF 440-450 MHz Transmission power 2 W Event receiving (through tel. line) Yes Event receiving (through serial) Yes (with individual cable) Input / Output 2 Output type / Load capacity Open collector / up to 50 ma Operating temperature -10 C / 50 C Case protection IP 53 Sizes (W / L / H) 72 x 118 x 34 mm Weight 235 g 8