APPLICATION BULLETIN

Similar documents
Precision Gain=10 DIFFERENTIAL AMPLIFIER

APPLICATION BULLETIN

Dual FET-Input, Low Distortion OPERATIONAL AMPLIFIER

Sensor Interfacing and Operational Amplifiers Lab 3

APPLICATION BULLETIN

Fast-Settling FET-Input INSTRUMENTATION AMPLIFIER

Single Supply, MicroPower INSTRUMENTATION AMPLIFIER

High Speed BUFFER AMPLIFIER

Dual FET-Input, Low Distortion OPERATIONAL AMPLIFIER

Low Noise, Low Distortion INSTRUMENTATION AMPLIFIER

SENSOR DESIGN, SIGNAL CONDITIONING, AND INTERFACING PROJECT MAE 534 Mechatronics Design SPRING 1999 Dr. Ramasubramanian

Precision 4mA to 20mA CURRENT LOOP RECEIVER

High Accuracy INSTRUMENTATION AMPLIFIER

Precision INSTRUMENTATION AMPLIFIER

High Current, High Power OPERATIONAL AMPLIFIER

Low Power, Precision FET-INPUT OPERATIONAL AMPLIFIERS

Dual FET-Input, Low Distortion OPERATIONAL AMPLIFIER

Precision 4mA to 20mA CURRENT LOOP RECEIVER

High Speed FET-Input INSTRUMENTATION AMPLIFIER

Precision VOLTAGE REFERENCE

High Current High Power OPERATIONAL AMPLIFIER

250mA HIGH-SPEED BUFFER

Precision, Low Power INSTRUMENTATION AMPLIFIER

16-Bit ANALOG-TO-DIGITAL CONVERTER

Programmable Gain AMPLIFIER

Precision OPERATIONAL AMPLIFIER

High Speed FET-INPUT OPERATIONAL AMPLIFIERS

High Power Monolithic OPERATIONAL AMPLIFIER

High Precision OPERATIONAL AMPLIFIERS

CMOS 12-Bit Multiplying DIGITAL-TO-ANALOG CONVERTER Microprocessor Compatible

Voltage-to-Frequency and Frequency-to-Voltage CONVERTER

Precision, Low Power INSTRUMENTATION AMPLIFIERS

Precision G = 100 INSTRUMENTATION AMPLIFIER

Precision, Low Power, Micropower Dual Operational Amplifier OP290

High Current, High Power OPERATIONAL AMPLIFIER

Ultra Low Input Bias Current INSTRUMENTATION AMPLIFIER

Low Power INSTRUMENTATION AMPLIFIER

High Power Monolithic OPERATIONAL AMPLIFIER

Differential Amplifier : input. resistance. Differential amplifiers are widely used in engineering instrumentation

Precision VOLTAGE REFERENCE

Precision, Low Power, Micropower Dual Operational Amplifier OP290

FET-Input, Low Power INSTRUMENTATION AMPLIFIER

Chapter 9: Operational Amplifiers

Precision High-Speed Difet OPERATIONAL AMPLIFIERS

MONOLITHIC PHOTODIODE AND AMPLIFIER 300kHz Bandwidth at R F = 1MΩ

C H A P T E R 02. Operational Amplifiers

Ultra-Low Bias Current Difet OPERATIONAL AMPLIFIER

MAS.836 HOW TO BIAS AN OP-AMP

Dual, High Voltage Current Shunt Monitor AD8213

Signal Conditioning for MEAS Pressure Sensors

Voltage-to-Frequency and Frequency-to-Voltage CONVERTER

Introduction to Analog Interfacing. ECE/CS 5780/6780: Embedded System Design. Various Op Amps. Ideal Op Amps

SINGLE-SUPPLY, RAIL-TO-RAIL OPERATIONAL AMPLIFIERS

Micropower, Single-Supply, Rail-to-Rail, Precision Instrumentation Amplifiers MAX4194 MAX4197

Difet Electrometer-Grade OPERATIONAL AMPLIFIER

MOSFET Amplifier Design Project Electrical Engineering 310 Section 002 Shawn Moser

Precision INSTRUMENTATION AMPLIFIER

High-Frequency VOLTAGE-TO-FREQUENCY CONVERTER

Optically-Coupled Linear ISOLATION AMPLIFIER

DUAL ULTRA MICROPOWER RAIL-TO-RAIL CMOS OPERATIONAL AMPLIFIER

Precision, Low Power INSTRUMENTATION AMPLIFIERS

Chapter 9: Operational Amplifiers

Lecture Notes Unit-III

Operational Amplifiers Part IV of VI Working Your Amplifier Inside the Single-Supply Voltage Box

Isolated, Unregulated DC/DC CONVERTERS

Input Offset Voltage (V OS ) & Input Bias Current (I B )

Quad 12-Bit Digital-to-Analog Converter (Serial Interface)

Instrumentation amplifier

QUAD 5V RAIL-TO-RAIL PRECISION OPERATIONAL AMPLIFIER

Dual 16-Bit DIGITAL-TO-ANALOG CONVERTER

MIC6211 A11. General Description. Features. Applications. Ordering Information. Functional Configuration. Pin Configuration.

Quad High-Speed Precision Difet OPERATIONAL AMPLIFIER

SAMPLE/HOLD AMPLIFIER

ES250: Electrical Science. HW6: The Operational Amplifier

PHOTODIODE WITH ON-CHIP AMPLIFIER

CMOS 12-Bit Serial Input Multiplying DIGITAL-TO-ANALOG CONVERTER

High Voltage, Current Shunt Monitor AD8215

Dual Precision, Low Cost, High Speed BiFET Op Amp AD712-EP

High-Voltage, Internally Powered ISOLATION AMPLIFIER

High Voltage Current Shunt Monitor AD8211

High Accuracy 8-Pin Instrumentation Amplifier AMP02

Input Stage Concerns. APPLICATION NOTE 656 Design Trade-Offs for Single-Supply Op Amps

INA126. MicroPOWER INSTRUMENTATION AMPLIFIER Single and Dual Versions IN ) G V IN G = 5 +

EE 330 Lecture 34. Guest Lecture. Why are there so many Op Amps?

QUAD 12-BIT DIGITAL-TO-ANALOG CONVERTER (12-bit port interface)

High Common-Mode Voltage Difference Amplifier AD629

High-Speed Programmable Gain INSTRUMENTATION AMPLIFIER

Homework Assignment 01

Low Cost, General Purpose High Speed JFET Amplifier AD825

Boosting output in high-voltage op-amps with a current buffer

LOGARITHMIC AMPLIFIER

Quad Picoampere Input Current Bipolar Op Amp AD704

Operational Amplifiers. Boylestad Chapter 10

TL082 Wide Bandwidth Dual JFET Input Operational Amplifier

LM833 Dual Audio Operational Amplifier

LF353 Wide Bandwidth Dual JFET Input Operational Amplifier

Chapter 10: Operational Amplifiers

LMC660 CMOS Quad Operational Amplifier

OBSOLETE. Low Cost Quad Voltage Controlled Amplifier SSM2164 REV. 0

Serial Input 18-Bit Monolithic Audio DIGITAL-TO-ANALOG CONVERTER

Transcription:

APPLICATION BULLETIN Mailing Address: PO Box 11400 Tucson, AZ 85734 Street Address: 6730 S. Tucson Blvd. Tucson, AZ 85706 Tel: (602 746-1111 Twx: 910-952-111 Telex: 066-6491 FAX (602 889-1510 Immediate Product Info: (800 548-6132 DIODE-BASED TEMPERATURE MEASUREMENT BY R. MARK STITT AND DAVID KUNST (602 746-7445 Diodes are frequently used as temperature sensors in a wide variety of moderate-precision temperature measurement applications. The relatively high temperature coefficient of about 2mV/ C is fairly linear. To make a temperature measurement system with a diode requires excitation, offsetting, and amplification. The circuitry can be quite simple. This Bulletin contains a collection of circuits to address a variety of applications. THE DIODE Just about any silicon diode can be used as a temperature measurement transducer. But the Silicon Temperature Sensor is a diode specifically designed and optimized for this function. It is intended for temperature sensing applications in automotive, consumer and industrial products where low cost and high accuracy are important. Packaged in a TO-92 package it features precise temperature accuracy of ±2 C from 40 C to +150 C. EXCITATION A current source is the best means for diode excitation. In some instances, resistor biasing can provide an adequate approximation, but power supply variations and ripple can cause significant errors with this approach. These problems are exacerbated in applications with low power supply voltages such as 5V single supply systems. Since the is specified for operation, the Burr-Brown Dual Current Source/Sink makes the perfect match. One current source can be used for excitation and the other current source can be used for offsetting. (1 + / voltage across diode (V Zero and span adjustments with and are interactive. Figure 1. Simple Diode-based Temperature Measurement Circuit. interactive adjustment technique. Another possible disadvantage is that the temperature to voltage conversion is inverting. In other words, a positive change in temperature results in a negative change in output voltage. If the output is to be processed in a digital system, neither of these limitations may be a disadvantage. resistor values for the Figure 1 circuit. (1 + / AMPLIFICATION In most instances, any precision op amp can be used for diode signal conditioning. Speed is usually not a concern. When ±15V supplies are available, the low cost precision OPA177 is recommended. For 5V single-supply applications, the Dual Single-Supply op amp is recommended. Its inputs can common-mode to its negative power supply rail (ground in single-supply applications, and its output can swing to within about 15mV of the negative rail. Figure 1 shows the simplest diode-based temperature measurement system. One of the current sources in the is used for diode excitation. The other current source is used for offsetting. One disadvantage of this circuit is that the span (GAIN and zero (OFFSET adjustments are interactive. You must either accept the initial errors or use an (δ /δt (25 + ( 25 C ( V1 ((δ /δt (δ /δt ( 1, Resistor values (Ω Voltage across diode (V 25 Diode voltage at 25 C (V Three choices are available for the See table on page 2. 1991 Burr-Brown Corporation AB-036 Printed in U.S.A. September, 1991

V 1 Output voltage of circuit at (V Output voltage of circuit (V Diode temperature coefficient (V/ C value depends on 25 See table below. Minimum process temperature ( C δ /δt Desired output voltage change for given temperature change (V/ C (Note: Must be negative for Figure 1 circuit. AVAILABLE VBE 25 AND VALUES FOR MOTOROLA TEMPERATURE SENSOR 25 (V (V/ C 0.580 0.002315 0.595 0.002265 0.620 0.002183 Design a temperature measurement system with a 0 to 1.0V δ /δt ( 1V 0V/(100 C 0 C 0.01V/ C 0.595V, 8.424kΩ 28.77kΩ For a 0 to 10V output with a 0 to 100 C temperature: 6.667kΩ 287.7kΩ If independent adjustment of offset and span is required consider the circuit shown in Figure 2. In this circuit, a third resistor, is added in series with the temperaturesensing diode. System zero (offset can be adjusted with without affecting span (gain. To trim the circuit adjust span first. Either or (or both can be used to adjust span. As with the Figure 1 circuit this circuit has the possible disadvantage that the temperature to voltage conversion is inverting. resistor values for the Figure 2 circuit. ( + (1 + / Set 1kΩ (or use a 2kΩ pot (δ /δt (25 + ( + ( 25 C ( V 1 ((δ /δt (δ /δt ( 1 Zero (offset adjust resistor (Ω Others as before Design a temperature measurement system with a 0 to 1.0V δ /δt ( 1V 0V/(100 C 0 C 0.01V/ C 0.595V, 1kΩ (use 2kΩ pot 9.717kΩ 33.18kΩ For a 0 to 10V output with a 0 to 100 C temperature: 1kΩ (use 2kΩ pot 7.69kΩ 331.8kΩ R Zero ( + (1 + / voltage across diode (V Adjust span first with or then adjust zero with Figure 2. Diode-based Temperature Measurement Circuit with Independent Span (gain and Zero (offset Adjustment. R1 2

For a noninverting temperature to voltage conversion, consider the circuit shown in Figure 3. This circuit is basically the same as the Figure 2 circuit except that the amplifier is connected to the low side of the diode. With this connection, the temperature to voltage conversion is noninverting. As before, if adjustment is required, adjust span with or first, then adjust zero with. A disadvantage of the Figure 3 circuit is that it requires a negative power supply. resistor values for the Figure 3 circuit. ( (1 + / + same as Figure 2 same as Figure 2 Components as before δ /δt (1V 0V/(100 C 0 C 0.01V/ C 0.595V, 1kΩ 9.717kΩ 33.18kΩ For a 0 to 10V output with a 0 to 100 C temperature: 1kΩ 7.69kΩ 331.8kΩ For a single-supply noninverting temperature to voltage conversion, consider the Figure 4 circuit. This circuit is similar to the Figure 2 circuit, except that the temperaturesensing diode is connected to the inverting input of the amplifier and the offsetting network is connected to the noninverting input. To prevent sensor loading, a second amplifier is connected as a buffer between the temp sensor and the amplifier. If adjustment is required, adjust span with or first, then adjust zero with. resistor values for the Figure 4 circuit. R Zero V S ( (1 + / + voltage across diode (V Adjust span first with or then adjust zero with Figure 3. Positive Transfer Function Temperature Measurement Circuit with Independent Span (gain and Zero (offset Adjustment. (1 + / / (T C V 1 (δ /δt (25 + ( 25 C ( (δ /δt 10kΩ (arbitrary (δ /δt ( Components as before δ /δt (1V 0V/(100 C 0 C 0.01V/ C 0.595V, 5.313kΩ 10.0kΩ 44.15kΩ 3

For a 0 to 10V output with a 0 to 100 C temperature: 6.372kΩ 10.0kΩ 441.5kΩ resistor values for the Figure 5 circuit. ((2 + 2 (1 + 1 GAIN GAIN 2 + 2 / 2 (δ /δt + 2 A 2 1 2 500Ω (use 1kΩ pot for Span (gain adjust resistor [Ω] Others as before R ZER O (1 + / / voltage across diode [V] Adjust span first with or then adjust zero with Figure 4. Single-supply Positive Transfer Function Temperature Measurement Circuit with Independent Span (gain and Zero (offset Adjustment. For differential temperature measurement, use the circuit shown in Figure 5. In this circuit, the differential output between two temperature sensing diodes is amplified by a two-op-amp instrumentation amplifier (IA. The IA is formed from the two op amps in a dual and resistors,, and. sets the gain of the IA. For good common-mode rejection,,, and R 4 must be matched. If 1% resistors are used, CMR will be greater than 70dB for gains over 50V/V. Span and zero can be adjusted in any order in this circuit. output for a 0 to 1 C temperature differential. δ /δt (1V 0V/(1 C 0 C 1.0V/ C 0.595V, 1kΩ pot,, 1% 455Ω For a 0 to 10V output with a 0 to 1 C temperature differential: 1kΩ pot,, 1% 45.3Ω 4

R 3 R 4 A 2 ((2 + 2 (1 + 1 GAIN GAIN 2 + 2 R / SPAN Adjust zero and span in any order. Figure 5. Differential Temperature Measurement Circuit. 5