ASSA ABLOY. Model W91 Overhead Concealed Wood Frame Installation Instructions IMPORTANT: BEFORE INSTALLING: TO DETERMINE HAND OF YOUR DOOR:

Similar documents
ASSA ABLOY Series Installation Instructions. Regular Arm. Parallel Arm. Top Jamb Mount. Multi-Sized 1 thru 6 Non-Hold Open and Hold Open Models

Installation Type. Edge of Door. Pull (Hinge) Side Mounted. Hinge Edge of Door. Push (Stop) Side Mounted

Installation Instructions. Installation Type

Installation Instructions

Installation Instructions. Installation Type

DC3210. Recommended Closer Size

316R Series Installation Instructions

Installation Instructions 50 (06-09) 1-15/32 15/32 21/32. 1/4-20 x 5/8" FHMS or #14 x 1/2" FHWS 1/16 1/4. Floor Plate

Installation Instructions 3040 (05-09) 9/16 9/ /32 9/32. Checking Adjustments

These door closers should NOT be installed on the exposed side (weather side) of exterior doors. WOOD 3/16" 1/4"- 20

5200 Series Door Closer Installation Instructions

INSTRUCTIONS FOR 1431 Door Closer with Hold Open Arms 1431 SERIES ADJUSTABLE FROM SIZE 1 THRU 6

Overhead Concealed Closers

Regular Arm Installation. Closer mounts on hinge side of door (pull side) See Page 3. Closer cover not shown. Top Jamb Installation

Checkmate Stops & Holders. Absolute Door Control and Entire Opening Protection

SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUO (JO & JP9) ARMS

SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUH (HOLD OPEN) ARMS

s tops & holder s Absolute Door Control and Entire Opening Protection

1431 DOOR CLOSER WITH STANDARD DUTY ARMS (WITHOUT HOLD OPEN) INSTALLATION INSTRUCTIONS 1431 SERIES ADJUSTABLE FROM SIZE 1 THRU 6

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2

351 DOOR CLOSER WITH DOUBLE LEVER ARM (OP) INSTALLATION INSTRUCTIONS

1530(F) Mortise Exit Devices Installation Instructions

Troubleshooting The Product You Have

CRL JACKSON 900 SERIES

How To Measure Your Finished Opening

Safety glasses Measuring tape Level Pencil Power drill Center punch Phillips screw driver Saw horse

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY.

Door Closers. General Information

FINISH GROUPS #17 GRP #17 CLEAR

*18758* 2030 Series. 1 Installation. 2 Adjustment. 3 Hold Open Information BACKCHECK. * Hold open tracks. Installation Instructions

400 Toll Free: (800) Phone: (718) Fax: (718) RIXSON Overhead Holders. Closer-Holder Packages

Installation Instructions

THRESHOLDS. Finishing Touch for Floor Closer Installations

Owner s Maintenance Section

TS93 STH. Surface applied door closer. Installation instructions: Pull side door mounted spring track Inverted closer with hold open (STH)

D3976 RECESSED EXIT INSTALLATION INSTRUCTIONS

C-Series & S-Series Classic Frame with Transom (Single or Pair)

ED5800 (A) Series. Installation Instructions. Concealed Vertical Rod. Exit Device WARNING

Senior Swing. Caution

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

(Wood Door and Frame)

Checkmate Stops & Holders

INSTALLATION INSTRUCTIONS Small Flat Panel Height-Adjustable, Extended Pitch Swing Arm Wall Mount Model KWE-110

Instructions for Prepping an Opening for SOSS Invisible Hinges

Installation Instructions. Hold Open Arm Models. Sized (Sizes 2,3,4,5) Weaker BC-H 9303BC-H 9304BC-H 9305BC-H

INSTALLATION INSTRUCTIONS. Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING

Active Push Bar. Safety glasses Measuring tape Level Pencil Power drill Drill bits: 5/32, 3/4 Center punch Phillips screw driver

800 SERIES. Heavy-Duty Commercial Grade 1 Surface Applied Closers. Standard Features. 3 hours fire rated. openings of the door.

Preference Collection and Treatment Console INSTALLATION GUIDE

Specialty Closers. High-End Residential High-End Security Gate Solutions

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

1500(F) Rim Exit Devices Installation Instructions

End of Row Doors. Revision Number 1

33/3527A. Devices covered by these instructions: 33/3527A-F (Fire) Surface Vertical Rod Exit Device

7130(F) Series Mortise Exit Devices Installation Instructions

7110(F), 7170(F)(LBR) Surface Vertical Rod Exit Device Series Installation Instructions

1510(F) Surface Vertical Rod Exit Devices Installation Instructions

WARRAntY & HInGE types

Privacy Wall Glass Selections - Polished Edge Slider Door

Shallow Depth Floor Closers. Complete Premium Door Control for Medium-Duty Interior Doors Where Concealment is Desired

Preference Collection 5580 Treatment Console INSTALLATION GUIDE

EXTRUTECH PLASTICS, INC. Custom Extruder of Close Tolerance Profiles

1790 Touchbar. Installation Instructions. Rim Panic Device ININST Index:

33/35A Series. Devices covered by these instructions: Rim Exit Device. CD33/35A Rim Exit Device EL33/35A Rim Exit Device SS33/35A Rim Exit Device

BioPrism Solid Surface

INSTALLATION INSTRUCTIONS

Thermally Broken Framing and Door Installation

INSTALLATION INSTRUCTIONS Flat Panel Static Wall Mount Model: GSM-111

Table of Contents Holders & Stops

INSTALLATION INSTRUCTIONS

Installation Instructions - Model V4JSD 1

Heavy-Duty Floor Closers

HIT-30 ALUMINUM DOOR SERIES OWNERS MANUAL

INSTRUCTIONS TS93 GSR PT RIGHT HAND ACTIVE LEFT HAND INACTIVE RIGHT HAND INACTIVE LEFT HAND ACTIVE

Parveneer Positive Pressure Fire Rated Frames Double rabbet with T stop for 20 minutes

98/9927. Devices covered by these instructions: Surface Vertical Rod Exit Device

INSTALLATION INSTRUCTIONS

Note: The dimensions of the Template are shown in inches. See attached page for the Metric Conversion Table for millimeters.

FIRE RATED DOOR AND FRAME GENERAL REQUIREMENTS

WD WD7000 Series

ICU TRACK SLIDING DOOR

*D-1030* 1 PARTS CHECK 8 REVERSING INSTRUCTIONS F-XX-C & XX-C D Customer Service. Installation Instructions. Exit Devices

ESA-300 Full Breakout

ICU TRACKLESS SLIDING DOOR

Design Considera ons & Installa on Guidance

Phone # La Jolla Doors. Block Frame Installation Manual Aluminum Frame with either Vinyl or Aluminum Panels

Installation Instructions. 45 and 60-Minute Positive Pressure Fire-Rated Veneered Door Frame UBC & UL-10C

PIVOT DOOR 3400P INSTALLATION INSTRUCTIONS

NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE. Installation Instructions

Heavy Wall Applied Stop Tube Frame and Door Installation

ASSEMBLY & INSTALLATION MANUAL OPCON IN-GROUND CONVERSION KIT FOR NABCO GT500

IMPORTANT: installation. FLOOR ANCHORED CEILING HUNG OVERHEAD BRACED FLOOR-TO- CEILING ANCHORED

Installation Instructions. 45 and 60-Minute Fire-Rated Neutral Pressure Veneered Door Frame UBC & UL-10C

INSTALLATION INSTRUCTIONS Medium Flat Panel Model MSP-SI1

INSTALLATION INSTRUCTIONS

Small Flat Panel Height-Adjustable Dual Swing Arm Wall Mount With Universal Slat Wall Mount (MSP-JS-KWG-110)

TorqueMaster Replacement Spring

LC200DS1 Double Stud Articulating Wall Mount for Flat Panel Screens up to 32" with up to 200mm x 200mm VESA Mounting Patterns

Flat Panel Dual Swing Arm Wall Mount (FWD-110) MSP-SA

Concealed Tab Mount 17.3 (.68) 11 (.44) 86 (3.38) 44 (1.72) 8 (5/16) Hex wrench opening. Receptacle panel. Latch. panel Ø 13 (.50) 44 (1.72) 19 (.

Transcription:

Model W91 Overhead Concealed s Wood Frame Installation Instructions *Butt or 3/4 Offset Pivot Hung, Multi Sized 1-3, 3-6 Non-Hold Open and Hold Open Models *Other means except 4-1/2" x 4-1/2" or 3/4" offset pivot hung, consult factory. IMPORTANT: BEFORE INSTALLING: An improperly installed or incorrectly adjusted door closer may cause property damage or personal injury and will void product warranty. To avoid personal injury, DO NOT DISASSEMBLE THIS DOOR CLOSER BODY. Door closers must be securely fastened to a prepped door and frame with fasteners provided. HOLD OPEN option not permitted to be installed in fire door assemblies. The Americans with Disabilities Act (ADA) requires that doors having door closers have an opening force not to exceed 5 lbf. The door closer's power size adjustment feature may require adjustment to its lowest setting to comply with ADA opening force guidelines. An auxiliary door stop, Rixson Checkmate surface applied overhead stops or others, is strongly recommended to avoid damage to the door closer and adjacent property. Doors should be hung on ball bearing or anti-friction hinges/pivots. ADA compliant closers may not latch doors, manufacturer does not guarantee latching on lower opening force settings. TO DETERMINE HAND OF YOUR DOOR: RHR LEFT HAND DOOR RIGHT HAND DOOR LHR Rixson is a registered trademark of Yale Security Inc., an Group company. Copyright 2016 Yale Security Inc., an Group company. All rights reserved. 1

Rixson is a registered trademark of Yale Security Inc., an Group company. Copyright 2015, Yale Security Inc., an Group company. All rights reserved. Wood Mounting Clip 22-3/4 (578) 1/8 (4) 5/8 (16) 2-3/4 (70) 3-3/4 (95) Width 23-5/8 (600) 4-15/16 (125) 5/8 (16) 22-3/8 (568) 2-1/16 (52) 5-3/8 (136) 7-7/16 (189) 7/16 (11) 17-3/16 (436) 22-9/16 (573) 22-3/4 (578) 1-3/4 (44) 1/4 (6) 3/4 (19) 1-1/4 (32) Mounting Plate Removable Stop 1-1/16 (27) 22-1/2 (572) Length of Track 7/8 (22) Varies with Door Thickness 5/16 (8) 2-1/16 (52) 23-5/8 (600) Cutout for Arm Top of Door DOOR Cutout for arm includes heel of door as shown. 23-5/8 (600) Length of Mortise A "A" Dimension Standard Application Retrofit Track Option Model W91 Overhead Concealed Butt Hinge, Wood Frame Max. Degree of Opening 91 Non Hold Open (135 ) With Track Stop 91 Non Hold Open (180 ) Without Track Stop 91H Hold Open (105 ) A removable frame stop must be used in combination with the closer for proper installation. Mounting holes for frame stop must span closer length. Stop must be removable to install closer and make proper adjustments. 4-9/16 (116) 1/8 (4) From Edge of Frame In All Cases Track A Optional Spacer 1-15/16 (49) Reveal Notes: 1. For 180 opening, max. allowable butt hinge size is 5" x 5". 2. Min. stop thickness 1/2". 3. 1/8" door to soffit clearance required. 4. Reinforcing per ANSI/SDI-100 recommended for hollow metal doors and frames. 5. Auxiliary stop recommended. 6. Do not scale drawing. 7. Dimensions given in inches (mm). 1-1/16" (27) 1-3/8" (35) Left Hand Door and Shown Right Hand Opposite www.rixson.com TEMPLATE NUMBER DATE OC60924 12/15 Rixson is a registered trademark of Yale Security Inc., an Group company. Copyright 2016 Yale Security Inc., an Group company. All rights reserved. 2

Rixson is a registered trademark of Yale Security Inc., an Group company. Copyright 2015, Yale Security Inc., an Group company. All rights reserved. 3/4 (19) 1-1/16 (27) Wood Mounting Clip Holes (4 Places) 2-3/4 (69.9) 5/8 (15.9) 5" (127) 4-9/16 (115.9) 7/16 (11) Typ 20-5/8 (523.9) 22-3/4 (577.9) 23-5/8 (600) Typ 1-1/2 (38.1) Attaching Screws #14 x 1-1/2 FHPWS (4 Places) 3/4 (19) 1" (25.4) 5-3/8 (136.5) 15-1/8 (384) 20-1/2 (521) 7/8 (22.2) 1/4 (6.4) Regardless of Door Thickness 1-1/4 (31.8) 4-9/16 (116) Model 180 Rixson Pivot 19" 482.6) Cutout for Arm Cutout At Top Of Door On Stop Side ONLY Do Not Cut Both Sides of Door Track Screws #14 x 1 FHPWS (4 Places) A Varies With Door Thickness Top of Door 22-1/2 (571.5) Length of Mortise for Track Model W91 Overhead Concealed 3/4" Offset Pivot Template Max. Degree of Opening - 115 91 Non Hold Open (Up to 115 ) 91 Hold Open (85 ) Doors must be beveled 1/8" in 2". A removable frame stop must be used in combination with the closer for proper installation. Mounting holes for stop must span closer length. Stop must be removable to install closer and make proper adjustments. 4-1/2 (114.3) Min. 3-23/32" (94.5) Cutout 9/64 (4) From Edge of Frame In All Cases Min Frame 2-1/4 (57.2) Base Plate Min. Cutout 1-3/4 (44.5) 1/8 (3.2) Removable Stop Track Retrofit Track Spacer (Optional) 1-15/16 (49) Reveal "A" Dimension Standard Application 1-1/16" (27) Retrofit Track Option 1-3/8" (35) www.rixson.com TEMPLATE NUMBER OC60936 DATE 08/15 Rixson is a registered trademark of Yale Security Inc., an Group company. Copyright 2016 Yale Security Inc., an Group company. All rights reserved. 3

Components: Figure 1 Left hand shown (Optional) Hold Open Track Assembly 90254 Non-Hold Open Stop Block Assembly 90255 Arm Slider 90253 Wood Mounting Clips 90257 RH Arm - 90237*** LH Arm - 90236*** Track 90239 Retrofit Track Spacer and Screws (Optional) 90260 (Not for new installation. For replacement only. Consult factory.) Arm Screw Pack 90259-*** Screw Pack 90241-*** Track Screw Pack 90242 It is recommended that the door, in which the door closer will be installed, be hung on ball bearing hinges or pivots. Door must swing freely. For other hanging means a special layout may be required, consult factory. A separate Rixson Surface Checkmate or other door stop, supplied by others, is recommended to prevent damage to the door closer, closer arm; or to the door, frame or adjacent walls. Door and Frame must be reinforced for attaching screws. All dimensions are given in inches with corresponding metric dimensions (millimeters) in parentheses. Rixson is a registered trademark of Yale Security Inc., an Group company. Copyright 2016 Yale Security Inc., an Group company. All rights reserved. 4

1 Verify Door Installation For Correctness Make sure the frame is plumb and square by using a carpenters' square. Note if the gaps between door and frame are consistent. Gap should be 1/16" at jamb and header. 1/16" (1.6) Using attached templates, check all dimensions of cut-outs. 2 Installation Left hand door illustrated. Attach wood clips to closer body with 1/4-20 x 5/8 FHPMS. Install closer with attached wood clips into frame with (4) #14 x 1-1/2 FHPWS mounting screws provided. Mounting plate should be flush with frame soffit. #14 x 1-1/2 FHPWS (4 each) 3 Check Arm Position Arm Position Prior To Door Attachment APPROX 15 Door Side The arm should be at approximately 15 degrees away from the door side of the closer mounting plate prior to door attachment. Arm always rotates in direction of door. Rixson is a registered trademark of Yale Security Inc., an Group company. Copyright 2016 Yale Security Inc., an Group company. All rights reserved. 5

4 Assembly of Track Components Slide track assembly components in track. Non Hold Open Track Assembly Install Components Stop block assembly or (optional) hold open assembly should be mounted towards the hinge side of the track as shown. The longer end of the slider should be pointed towards the hinge end of the track. Slider (Optional) Hold Open Track Assembly Install Components Slider 5 Track Installation Be sure to check that the slider and any track assembly components are installed prior to track installation. Install track and/or (optional) spacer (replacement application only, consult factory) using provided hardware in prepped door. 14-1-5/8 FHPWS (4 each) Long end of slider must be oriented toward the hinge/pivot end of door. Rixson is a registered trademark of Yale Security Inc., an Group company. Copyright 2016 Yale Security Inc., an Group company. All rights reserved. 6

6 /Door Attachment 1. With a 1/8" hex wrench, completely tighten the latch and sweep adjustments by turning the screws clockwise. This will allow for an easier closer/door connection. 1/8" Hex Key Latch Sweep Backcheck 2. Open door to about 45 degrees then rotate arm over to door. The arm should maintain position since the latch and sweep adjustments have been closed. 3. Align slider square with arm square and connect the two using the provided screw. If you choose to open the door beyond 45 degrees, note that the backcheck adjustment screw may have to be adjusted counterclockwise to easily rotate arm to door position. 1/4-20 x 3/4 Flat Head Hex Machine Screw w/loctite Provided Rixson is a registered trademark of Yale Security Inc., an Group company. Copyright 2016 Yale Security Inc., an Group company. All rights reserved. 7

7 Adjustments L-Latch S-Sweep B-Backcheck Do not take adjustment screws out or closer will leak oil. Opening Force Adjustment Opening Force Adjustment Locate opening force adjustment hex. Using 3/8" hex key, adjust opening force prior to sweep and latch adjustments. Size 1-3, 3-6 adjustment, see chart at right. All 91 series closers are factory set to minimum opening force. Adjust closer as necessary for more closing force taking into consideration door size, weight, positive room pressure, etc. A lower opening force means a lower closing force. To achieve stronger closing forces, turn 3/8" hex clockwise. Keep in mind that the opening force will be increased as well. After the opening/closing force has been set to satisfactory forces to close the door, adjust the sweep, latch and backcheck valves to control the speed of the door. Holes are shown in the mounting plate above to provide access to the adjustment valves using a 1/8" hex wrench. "L" Latch 5 0 Slower 1/8" Hex Key Fa r ste "S" Sweep 5 Slower 1/8" Hex Key Fa r ste Size Spring Adjustment Model PH91 Sizes 1-3 Model 91 Sizes 3-6 Approx. # of Turns Size Approx. # of Turns ADA 0 3 0 1 15 4 17 2 30 5 25 3 55 6 32 shipped at lowest spring setting. 1/8" Hex Key "B" Backcheck - Weaker + Stronger USE HEX KEYS TO MAKE ANY CLOSER ADJUSTMENTS. DO NOT USE POWER DRIVERS. 75 Do not use backcheck to achieve dead stop. Rixson is a registered trademark of Yale Security Inc., an Group company. Copyright 2016 Yale Security Inc., an Group company. All rights reserved. 8

8 (Optional) Hold Open Adjustment Increase Decrease + - Holding Force Adjustment Screw Set Screws Track Slider Locking Tab Engage locking tab of hold open assembly in track slider. Hold open assembly should be on hinge side of track slider. Open door to desired hold open position. Tighten hold open mounting set screws to lock down hold open assembly. Pull door in the closing direction to disengage hold open assembly and track slider. To increase the amount of force necessary to pull door out of hold open, tighten the holding force adjustment screw clockwise. To decrease the amount of force necessary to pull door out of hold open, loosen the holding force adjustment screw counterclockwise. NOTE: THIS FEATURE CANNOT BE USED ON FIRE-RATED DOORS 9 Removable Stop Installation After closer is installed and all adjustments are complete, install removable stop. No holes should be drilled in the closer mounting plate. Rixson is a registered trademark of Yale Security Inc., an Group company. Copyright 2016 Yale Security Inc., an Group company. All rights reserved. 9

Troubleshooting Symptom Cause Remedy Spring tension not strong enough. Use spring adjuster to increase tension. See Step 7. Door won't latch. Door is too difficult to open. Latch speed control not fast enough. Door hung on products other than 4-1/2 x 4-1/2 butts or 3/4 offset pivots. Arm is not preloaded. Spring tension is set too strong. Adjust latch speed valve. See Step 7. Send template for the hanging means to the factory. A new installation sheet is required. will need to be relocated. See Step 6. Use spring adjuster to decrease tension. See Step 7. 3000 Highway 74 East Monroe, NC 28112 Tel: (866)-474-9766 www.rixson.com Rixson is a registered trademark of Yale Security Inc., an Group company. Copyright 2016 Yale Security Inc., an Group company. All rights reserved. 10