Installation and start up instructions. Synchroniser type FAS-115DG uni-line H (UK) Synchronisation of generator to busbar

Similar documents
Installation and start up instructions. Synchroniser type FAS-113DG uni-line F (UK) Synchronisation of generator to busbar

Installation and start up instructions. Paralleling relay type HAS-111DG uni-line G (UK) Synchronisation of generator to busbar

DATA SHEET. Paralleling relays, HAS-111DG ANSI code 25

Installation and start up instructions. Detection of vector shift. Detection of over- and underfrequency. Generator disconnection on mains failure

Automatic synchronising relay

DEIF A/S. TAS-311DG Selectable AC transducer J (UK) Installation and start up instructions

DATA SHEET AC current single function transducer TAC-311DG/TAC-321DG

DEIF A/S. Application note. Generators parallel with mains Multi-line 2 version 2. Application description. Power import control. Power export control

DEIF A/S. Description of options. Option H3 Serial communication Profibus DP Multi-line 2 version 2. Description of option. Functional description

DEIF A/S. Description of options. Option H1 Serial communication CAN open. Description of options. Functional description. Tables.

DATA SHEET Reverse power relays, RMP-121D ANSI code 32

DEIF A/S. Description of options. Option H1, CAN open communication Basic Gen-set Controller. Description of option. Functional description

Installation/operation instructions. Insulation monitor type SIM-Q/SIM-Q LF D (UK) Measuring range 1...0Mohm or 10...

DATA SHEET Differential current relays, RMC-131D ANSI code 87

DATA SHEET. Voltmeters and Ammeters,

Function. Adjustment. Extra functions included. Modes. Housing

RMV-122D, RMV-132D ANSI

DEIF A/S. Insulation monitor. Type SIM-Q

DATA SHEET Selectable AC transducer TAS-311DG

Protection relays and controllers. Types TRANSAL DC-2TF, ACV-3TF, ACI-3TF, PFC-2TF TRANSAL DC-2TB, AVC- 3TB, ACI-3TB, PFC-2TB

TCM-2 Thyristor Control Module DATA SHEET

V AC Meas. current (In): A. Frequency range: Hz. Measuring system:

DEIF A/S. User s manual. Read synchroscope type RSQ-3. Precision LED synchronoscope. High immunity to harmonic distortion F (UK)

DEIF A/S. Application Notes. Basic Gen-set Controller. Single generator set. Automatic mains failure. Parallel with mains (grid)

DEIF A/S. Insulation monitor. Type SIM-Q/SIM-Q LF

Transducers for AC measurement. Types TAP, TAQ, TMF, TAA, TAV, TAC. Measurement of: watt, var, frequency, phase angle, voltage, current

DATA SHEET. CIO multi-inputs. CAN bus-based I/O module

DATA SHEET. Switchboard instruments,

DEIF A/S. Application Notes. MDR-2 test procedures. Test of current measurement. Test of differential current measurement.

Summation current transformers, type KSU/SUSK

for variable pitch thrusters

Option H2, Modbus communication Automatic Gen-set Controller H SW version 2.33.X

SELCO T-Line Generator Control, Protection and Monitoring

SIGMA S6100 S/LS Module

Primary winding current transformer, type WSK

PARAMETER LIST PARAMETER LIST

Option D1 Voltage/var/cos phi control Description of option Functional description

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)

DESIGNER S REFERENCE HANDBOOK

Designer s Reference Handbook. Paralleling and Protection Unit/GS Multi-line I SW version 2.4X.X. Display unit and menu structure

XU2-AC AC voltage relay. (Februar 1997) Manual XU2-AC (Revision New)

XN2 - Mains decoupling relay. Manual XN2 (Revision C)

Company Replaces previous document Document ID Issue E.ON Elnät Sverige AB Ny engelsk utgåva D

Selection tables Command devices E 250 latching relays

Output of three-phase motors at 50 Hz and 400 V

Installation Instructions and Reference Handbook. Installation instructions

XF2 Frequency Relay. Manual XF2 (Revision A)

SYNCHRONISM RELAY SYNCRO-96. (Code ) INSTRUCTION MANUAL ( M / 99A ) (c) CIRCUTOR S.A.

Capacitor Switching Contactors

XN2 - Mains decoupling relay

T4500 AUTO SYNCHRONIZER T4800 LOAD SHARER T4900 VAR LOAD SHARER

Angle position transmitter Type RT-2 Marine bridge instrumentation C (UK) Measuring output: DC current signal 0..20mA or 4..

Remote Maintenance Box, RMB

XUA1 - AC Voltage and phase balance relay

XI1-I Time overcurrent relay. (Januar 2007) Manual XI1-I (Revision New)

Electronic potentiometer EPQ96-2

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

PRODUCT / TEST MANUAL 2V162K4 VOLTAGE REGULATOR RELAY

02/11/2015

The universal input/output device is a DIN rail mounted device. It is connected to the EIB via a bus connecting terminal.

Functional Range. Synchronising Relay : UN1, FN2, SY1, SY/SP. C&S Protection & Control Ltd.

XP2-R Power and reverse power relay. (January 2006) Manual XP2-R (Revision New)

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

ESTAmat MH Mounting Instructions MV1151

Synchronisation meters for manual or semiautomatic synchronisation Synchronization Meters SQ0114/SQ0104 Synchronization Meters SQ0214/SQ0204

Phase and neutral overcurrent protection

XP2-R Power and Reverse Power Relay

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Instructions for D64RPB30 Series C1 Ground Fault Relay

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

C.A 6115N. Safety at all costs. IEE 16th: Electrical installation IEC/EN I E C. Insulation RCD. Earth. Loop. Continuity.

ENS26 Automatic Isolation Unit Product Description

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

ENS31 Automatic Isolation Unit Product Description

HEP300 ELECTRONIC POTENTIOMETER USER MANUAL

Harmonic restraint earth fault or single-phase overcurrent protection

200ADM-P. Current Injection System with Phase Shift A 3.000s 2.000A 50.00Hz 0.0. Features

Current Loop Interface Module M-2025C

Electronic Amplifier Model VT 3017 and VT 3018 (Series 3X) for the control of proportional directional valves, without positional feedback

PRetrans Table of contents

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71

ULTRASTAB IHF Precision Current Transducer

Three-phase monitoring relay

PRODUCT/TEST MANUAL 2V162K12 VOLTAGE REGULATOR RELAY

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

McPherson Voltage Regulators 4501 NW 27 Ave Miami FL

Option T2 Digital AVR: DEIF DVC Leroy Somer D510C Description of option Functional description

Multi Differential Relay, MDR-2 DESCRIPTION OF OPTIONS

T6+ Analog I/O Section. Installation booklet for part numbers: 5/4-80A-115 5/4-90A-115 5/4-80A /4-90A-1224

NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function.

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

NPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Photo-electric Amplifier ISG-A123 1-channel automatic amplifier

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

COMPONENTS. Power contactor Type BMS09.08 / BMS18.08

Transcription:

Installation and start up instructions Synchroniser type FAS-115DG uni-line Synchronisation of generator to busbar With voltage matching Circuit breaker time compensation LED indication of status DEIF A/S LED indication for synchronising signal 35 mm DIN rail or base mounting DEIF A/S Tel: (+45) 9614 9614 Frisenborgvej 33, DK-7800 Skive Fax: (+45) 9614 9615 Denmark E-mail: deif@deif.com

1. Description This synchroniser with voltage matching type FAS-115DG forms part of a complete DEIF series (the uni-line) of relays for protection and control of generators. The FAS- 115DG synchroniser measures the busbar and generator voltages and frequencies and compares these, plus compares their phase angles. It controls the generator frequency and voltage, till they match the busbar values. In order to determine phase accordance between the generator and the busbar, the synchroniser calculates a phase angle advance based on the circuit breaker closing time and the slip frequency. When the phase difference is within this tolerance, the synchroniser transmits a closing signal for the generator circuit breaker allowing time for this to close. 2. Label The synchroniser is provided with a label with the following data: Measuring voltage Type designation DEIF s order ack. No. To be stated when contacting DEIF Mounted voltage module Supply voltage (E.g. special circuit breaker time, etc.) Highest voltage in relation to earth Installation category Distributor s ID No. Filled in by distributor when customizing the unit. 3. Mounting instructions The FAS-115DG is designed for panel mounting, being mounted on a 35 mm DIN rail, or by means of two 4-mm screws. Weight: Approx. 0.750 kg Page 2 of 5 Tel.: (+45) 9614 9614 Fax: (+45) 9614 9615 E-mail: deif@deif.com

Installation and start up instructions FAS-115DG The design of the synchroniser makes mounting of it close to other uni-line units possible, however make sure there are min. 50 mm between the top and bottom of this relay and other relays/units. The DIN rail must always be placed horizontally when several relays are mounted on the same rail. 4. Connection diagram All voltage inputs may be protected by a 2A fuse. The synchroniser is protected against ESD (electrostatic electricity), and further special protection against this during the mounting of the unit is not necessary. The FAS-115DG may be connected between 2 phases or between 1 phase and neutral. The synchroniser is to be configured so that the input of the FAS-115DG corresponds to the connected voltages. The relay contacts mrk. SG (term. Nos. 38 + 39 and 40 + 41) provide relay signals for increase and decrease of the speed, respectively, and those mrk. AVR (term. Nos. 43 + 44 and 45 + 36) relay signals for increase and decrease of the voltage, respectively. The life of the built-in relays is considerably reduced when connected to inductive loads. Especially for DC controlled pilot/servomotors, external auxiliary relays should therefore always be mounted. Mounting a transient suppressor across the coils of the auxiliary relays is likewise recommended. During start up activating the inhibit function (by short-circuiting term. Nos. 34 and 35) is recommended. This function disables the SYNC relay contact, to which the circuit breaker is connected (term. Nos. (8), 9 and 10). When the FAS-115DG is applied for simultaneous synchronisation of all generators of a plant to the busbar, the FS line of the load sharing units type LSU is connected to terminals Nos. 36 and 35. The unit is equipped with a self-monitoring function. The self-monitoring function supervises the microprocessor and hereby verifies if the programme is running correctly. Supply voltage not connected or not acceptable Supply voltage is accepted and the unit is running correctly Supply voltage is accepted but the unit is running wrongly Power LED Constant green light Flashing green light 2-3Hz Status output ON

GL applications only: For applications approved by Germanischer Lloyd the status output must be connected to an alarm system. For applications with more than one uni-line product the status outputs of the units can be connected in series to the same alarm input. When the units are connected in series the flashing green power LED will indicate the unit that is running wrongly. 5. Start up instructions 5.1 Setting and indication Setting of Range T N Control pulse length 25 500 ms X p Proportional band ±0.25 ±2.5Hz f set Slip frequency 0.1 0.5Hz U max Acceptable voltage difference ±2 ±12% of U BB T BC Breaker closure time 20 200 ms LEDs Light U G Generator voltage* Green, U BB Busbar voltage* when value is within the acceptable range f Frequency difference* Switched off, U Voltage difference* if outside this range SYNC Synchronising SG Increasing speed (frequency) Yellow, SG Decreasing speed (frequency) when relay is activated AVR Increasing voltage AVR Decreasing voltage *) When all 4 LEDs are lit, the conditions for transmission of synchronisation pulses are fulfilled. Note: In addition to the status (4 conditions above) the FAS-115DG supervises the actual df/dt (ROCOF). If this is too great, no synchronisation pulses will be transmitted, and the f LED flashes. The allowable df/dt ratio depends on the f set setting: f set 0.1Hz corresponds to a df/dt ratio of max. 2.5Hz/s. f set 0.5Hz corresponds to a df/dt ratio of max. 12.5Hz/s. The T N and X p should be set during the start up. Correct setting of these is of major importance, to ensure a stable control of the generator. T N determines the duration of the control pulse. A short T N is applied for very swiftly reacting speed governors, a long T N for slowly reacting speed governors. Recommended starting point: 0.2 s. If the frequency tends to oscillate around the f set value: - Reduce T N (min. pulse: 25 ms), until stable control is obtained, - then reduce X p (e.g. to ±1Hz), until the control loop becomes unstable again and select a suitable X p value between these values (e.g. ±1.5Hz). Page 4 of 5 Tel.: (+45) 9614 9614 Fax: (+45) 9614 9615 E-mail: deif@deif.com

Installation and start up instructions FAS-115DG X p f set determines the span within which the pulse ratio changes proportionally to the frequency deviation from the f set value. Recommended starting point: 2.5Hz. is set to the required slip frequency. Set to 0.5Hz to ensure a swift synchronisation (emergency generators). Set to 0.1Hz to ensure a very accurate synchronisation. Recommended starting point: 0.5Hz. Then reduce f set (e.g. to 0.2Hz) until the synchronising time becomes too long or the synchronisation conditions are not fulfilled (unstable control) increase again, and select a suitable f set value between these values (e.g. 0.3Hz). U max determines the acceptable difference between busbar and generator voltages. Set to ±2% when synchronising a powerful generator to a stable network. Set to ±12% when synchronising a generator to unstable busbars. T BC is set to the circuit breaker closure time (indicated on the circuit breaker). Correct setting is of major importance, as it affects the accuracy of the synchronisation. 6. Options For description and activation of the options available for FAS-115DG, please see the data sheet of FAS-115DG and the Customisation Manual at www.deif.com.