General Specifications

Similar documents
General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

General Specifications

Field indicator for current loops with HART communication Models DIH50, DIH52

General Specifications

Introduction Intrinsic safe system How to select sensors How to select safety barriers...6 Revision Information...

DPharp Differential Pressure and Pressure Transmitters

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Wireless Multi Discrete Input Transmitter Series XYR 6000, Model STXW500 Specifications

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

Rosemount 702 Discrete Input Transmitter

Field Wireless Access Point

IP26 Series Current to Pneumatic Converter

Loop Powered Indicator

Power supply. Calibration. Surface finishing. Seal. Process connection

Field indicator for current loops with HART communication Models DIH50, DIH52

Certificate of Conformity

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

General Specifications

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Isolators A3/1.

Temperature Input Module for Zone 1 Series 9482/32

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Analog Universal Module HART for Zone 2 Series 9468/33

Digital Input Output Module for Zone 2 Series 9470/33

General Specifications

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

General Specifications

Binary Output without Power Supply Series 9176

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Armstrong Intelligent Monitoring Installation and Operation Manual

Digital Input Output Module for Zone 1 Series 9470/32

Model 264IB. ABB 2600T Series Engineered solutions for all applications

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Isolators A3/1. Vibration Transducer Supply Unit Series

XYR 6000 Wireless Temperature/Discrete Input Transmitter Series 400 Specifications

Digital Input Output Module for Zone 2 Series 9470/33

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

Level Plus. SoCLEAN Data Sheet. Magnetostrictive Liquid Level Transmitters with Temposonics Technology

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Rosemount 248 Wireless Temperature Transmitter

ICARUS ELECTRONIC GAS VOLUME CONVERTER

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

General Specifications

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

General Specifications

General Specifications

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

Wireless Dual Discrete Input Transmitter Series XYR 5000, Model WW59x Specifications - Americas

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Resistance thermometer Model TR30, compact design

RMA42. Technical Information

Process display RIA 261

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

STT 3000 Smart Temperature Transmitter Series STT170 Specifications

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

[ Rosemount 648 Wireless Temperature Transmitter. Rosemount 648 Wireless. Quick Installation Guide , Rev CA August 2011

Remote I/O. 74 Remote I/O. Remote I/O System

Level Measurement Continuous level measurement Radar transmitters

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

Rosemount 648 Wireless Temperature Transmitter

Rosemount 705 Wireless Totalizing Transmitter

XYR 6000 Wireless High Level Analog Input Transmitter Model STIW600 0 to 5 Volts 1 to 5 Volts 0 to 20 ma 4 to 20 ma

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

Fisher 646 Electro Pneumatic Transducer

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

LEO RECORD Ei Intrinsically Safe Digital Manometer with Record Function for use in Hazardous Applications. Accuracy: 0,1 %FS

Rosemount 248 Wireless Temperature Transmitter

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater

Positioner with HART Communication Type 3780

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE

Rosemount 3101, 3102, and 3105

Accutech FL10. Wireless float level field unit

Transcription:

General Specifications FN310 Field Wireless Multi-Protocol Module GENERAL This General Specification (GS) describes the specifications for Field Wireless Multi-Protocol Module. Combined with Field Wireless Communication Module FN110, this product is connectable with a field wireless network as a field wireless device. This product acquires sensor data from a connected sensor and transmits it to a field wireless network through FN110. Refer to General Specifications of Field Wireless Communication Module FN110 for an overview and detailed information. FEATURES Protocol conversion This product can convert a wired communication protocol to the ISA100 Wireless protocol, and transmit it to a field wireless network. ISA100 Wireless is an international, industrial wireless networking standard engineered to serve the needs of process industries. Multi-protocol support HART or Modbus* communication protocol can be selected. Various wired legacy device required by plant operation can be converted into a wireless device as required. * Future release Installation flexibility With built-in batteries, this product can supply power to the connected field device, eliminating the need for cables. Cable elimination allows installing a device at locations where it was previously either inaccessible or costprohibitive because of cable management and cost. Small and lightweight housing with LCD This product has a small and lightweight housing with a built-in LCD that displays the process data and communication status. STANDARD SPECIFICATIONS POWER SUPPLY SPECIFICATIONS Battery: Dedicated battery pack. Rated voltage: 7.2 V Rated capacity: 19 Ah Battery Pack: 2x primary lithium-thionyl chloride batteries With battery case (batteries sold separately) PERFORMANCE SPECIFICATIONS Update Period: 5 to 3600 s selectable [Protocol code: M, Connection Type: DT2] 8 to 3600 s selectable Battery Characteristics: At one-to-one connection, the typical battery life is 4 years when BootStrapTime* 1 * 2 of the HART device is 10 seconds or 1 year when BootStrapTime* 1 * 2 is 60 seconds, under the following conditions* 3 : Ambient temperature: 23 ±2 C role: IO mode Update period: 10 minutes LCD display: off *1: BootStrapTime is defined as the time from the power-on of the HART device until the reliable data is available. *2: For BootStrapTime, please contact the manufacturer of the connected HART device. *3: Environmental condition such as vibration and the type of connected HART device may affect the battery life. At 4-20 ma loop connection, the typical battery life is 8 years at 10 seconds update time or 5 years at 5 seconds update time in the following conditions.* 1 Ambient temperature: 23 ±2 C role: IO mode LCD display: off *1: Environmental condition such as vibration may affect the battery life. [Protocol code: M, Connection Type: DT2] The typical battery life is 8 years under the flowing conditions* 1 : SENCOM: FU20F-NPT Ambient temperature: 23 ±2 C role: IO mode Update period: 10 minutes LCD display: off *1: Environmental condition such as vibration and the type of connected Modbus device may affect the battery life. Yokogawa Electric Corporation 2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan Tel.: 81-422-52-5690 Fax.: 81-422-52-2018 Copyright June 2014 1st Edition: June 2014 (KP) 8th Edition: July 2018 (KP)

2 FUNCTIONAL SPECIFICATIONS Input: This product has HART master function and enables setting primary and secondary. Communication specifications between this product and HART devices are below. Protocol revision: HART 7* Communication mode: HART multidrop connection 4 ma fixed HART point-to-point connection 4-20 ma Number of HART devices: 1 device Cable: Max 20 m (AWG14 to 22 with shield) * The HART protocol ensures backward compatibility with the previous revisions. [Protocol code: M] Communication specifications between this product and Modbus devices are below. Communication Mode: Half-duplex communication (RS-485 compliant) Protocol: Modbus RTU Communication Speed: 9600 bps Number of Modbus devices: 1 device Cable: Max 20 m (AWG14 to 22 with shield) Connection s: Connecting a HART device enables to acquire PV, SV, TV and QV. Connecting a SENCOM enables to acquire ph, ORP, rh and temperature. To perform the calibration of SENCOM, use SPS24 SENCOM PC Software. Output: Communication specifications between this product and FN110 are below. Communication Mode: Half-duplex communication (RS485 compliant) Communication Speed: 9600 bps Connector: 5-pin round connector dedicated Cable: Max 20 m (dedicated cable) Power Supply: Power supply to the FN110 Supply voltage: 3.5 V Supply current: 50 ma Power supply to the HART device* 1 * 2 * 3 Maximum supply voltage: 18 V (steady-state) Maximum supply current: 12 ma (steady-state) *1: HART devices operate at 4 ma current-fixed mode. *2: Before using, make sure the minimum operating voltage of the HART device is 16.5V or less with 0 ohm load. *3: Supplies power when using VOUT terminal. [Protocol code: M] Power supply to the Modbus device Supply voltage: 3.5 V Supply current: 10 ma Integral Indicator (LCD display): 5-digit numerical and status display. Display contents and display on/off can be controlled with a magnet (not included). The indicator displays the following information: Wireless communication status, device status, write protection status, sensor data and alarm message Diagnosis Functions: Power failures, inter module communication failures, sensor communication failures, memory errors, battery alarm, abnormal temperature Software Download Function: Software download function permits to update wireless field device software via ISA100 Wireless communication. INSTALLATION ENVIRONMENT Ambient Temperature Limits: Operating: 40 to 85 C (altitude up to 3000 m) 30 to 80 C (LCD visible range) Storage: 40 to 85 C Ambient Humidity Limits: Operating: 0 to 100%RH (non-condensation) Storage: 0 to 100%RH (non-condensation) Ambient Temperature Gradient: Operating: ±10 C/h or less Storage: ±20 C/h or less Vibration Resistance: 0.21 mm P-P (10-60 Hz), 3 G (60-2 khz) Shock Resistance: 50 G 11 ms REGULATORY COMPLIANCE STATEMENTS This product satisfies the following standards. * Please confirm that an installation region fulfills an applicable standard. If additional regulatory information and approvals are required, contact a Yokogawa representative. CE Conformity: EMC Directive: EN61326-1 Class A Table 2, EN55011 Class A RoHS Directive: EN50581 ATEX Directive: See OPTIONAL SPECIFICATIONS (For Explosion Protected Types) Other Normative Standards: Safety: EN61010-1 (Indoor/Outdoor use) Canadian Safety Standards: CAN/CSA-C22.2 No.61010-1 CAN/CSA-C22.2 No.94.1, CAN/CSA-C22.2 No.94.2 IEC 60529 Degrees of Protection: IP66, IP67 and Type 4X apply when the connector is properly tightened. PHYSICAL SPECIFICATIONS Connections: Refer to MODEL AND SUFFIX CODES. Housing Material: Plastic (Polycarbonate) Weight: 500 g (without mounting bracket, clamp, and battery) Mounting: Refer to MODEL AND SUFFIX CODES. Apr. 14, 2017-00

3 MODEL AND SUFFIX CODES Model Suffix Code Descriptions FN310... Field Wireless Multi-Protocol Module General Specification Inter module communication -A1... Digital communication for FN series Protocol -J... -M... Digital communication (HART 7 * 1 ) Digital communication (RS485 Modbus Protocol) Housing Material 0... Plastic (Polycarbonate) Electrical connection 0... Horizontal connection: blind plug, Vertical connection: G 1/2 female * 2 1... Horizontal connection: blind plug, Vertical connection: 1/2 NPT female * 2 2... Horizontal connection: blind plug, Vertical connection: M20 female * 2 3... Horizontal connection: G 1/2 male with clamp, Vertical connection: blind plug * 3 * 4 4... Horizontal connection: 1/2 NPT male with clamp, Vertical connection: blind plug * 3 * 4 5... Horizontal connection: M20 male with clamp, Vertical connection: blind plug * 3 * 4 6... Horizontal connection: blind plug, Vertical connection: blind plug * 5 --- A... Always A Integral indicator -D... Digital indicator Mounting bracket J... 316 SST 2-inch pipe mounting (for horizontal piping) K... 316 SST 2-inch pipe mounting (for vertical piping) N... None --- A... Always A --- A... Always A --- -A... Always A --- A... Always A Option codes / Optional specifications *1: The HART protocol is backward-compatible with previous versions. *2: Cable gland is not included. Prepare the cable gland with a flat gasket. *3: Select when directly attached to the electrical connection port of HART devices.(protocol code J only) *4: Make sure before use that the vibration characteristics and the strength of the connection port of the HART device are fulfilled. (Protocol code J only) *5: Select when intended to use as a routing device. Apr. 22, 2016-00

4 OPTIONAL SPECIFICATIONS (For Explosion Protected Types) Protocol code: J Item Description Code Factory Mutual (FM) ATEX IECEx United States Canada FM Intrinsically safe Approval (United States) Applicable Standards: Class 3600:2011, Class 3610:2010, Class 3810:2005, ANSI/ISA-60079-0-2013, ANSI/ISA-60079-11-2014, NEMA 250-2003, ANSI/IEC-60529-2004 (R2011) Intrinsically safe for Class I, II, III, Division 1, Groups A, B, C, D, E, F & G, Class I, Zone 0, in Hazardous Locations, AEx ia IIC Enclosure: IP66 and Type 4X, Temperature Class: T4, Amb. Temp. : 40 to 70 C (40 to 158 F) Uo = 5.88 V, Io = 613 ma, Po = 907 mw, Co = 5.82 μf, Lo = 25 μh VOUT (Terminal 1, 2) Uo = 23.1V, Io = 87 ma, Po = 450 mw, Co = 100 nf, Lo = 3 mh COMM (Terminal 3, 4) Ui = 30 V, Ii = 300 ma, Pi = 1 W (linear source), Ci = 20 nf, Li = 0 μh FM Intrinsically safe Approval (Canada) Applicable Standards: CAN/CSA-C22.2 No. 0-10 (R2015), CAN/CSA-C22.2 No. 94.1-07(R2012), CAN/CSA-C22.2 No. 94.2-07(R2012), CAN/CSA-C22.2 No. 60079-0:11, CAN/CSA-C22.2 No. 60079-11:14, CAN/CSA-C22.2 No. 60529-05 (R2015), CAN/CSA-C22.2 No. 61010-1-12 Ex ia IIC T4 Ga Intrinsically safe for Class I, II, III, Division 1, Groups A, B, C, D, E, F & G Enclosure: IP66 and Type 4X, Temperature Class: T4, Amb. Temp.: 40 to 70 C (40 to 158 F) Uo = 5.88 V, Io = 613 ma, Po = 907 mw, Co = 5.82 μf, Lo = 25 μh VOUT (Terminal 1, 2) Uo = 23.1V, Io = 87 ma, Po = 450 mw, Co = 100 nf, Lo = 3 mh COMM (Terminal 3, 4) Ui = 30 V, Ii = 300 ma, Pi = 1 W (linear source), Ci = 20 nf, Li = 0 μh ATEX Intrinsically safe Approval Applicable Standards: EN 60079-0:2012A11:2013, EN 60079-11:2012, EN 60079-28:2015 Certificate: FM 15ATEX0069X II 1 G Ex ia op is IIC T4 Ga Degrees of protection: IP66 according to EN 60529:1991A1:2000A2:2013 Amb. Temp. (Tamb): 40 to 70 C (40 to 158 F) Uo = 5.88 V, Io = 613 ma, Po = 907 mw, Co = 5.82 μf, Lo = 25 μh VOUT (Terminal 1, 2) Uo = 23.1V, Io = 87 ma, Po = 450 mw, Co = 100 nf, Lo = 3 mh COMM (Terminal 3, 4) Ui = 30 V, Ii = 300 ma, Pi = 1 W (linear source), Ci = 20 nf, Li = 0 μh IECEx Intrinsically safe Approval Applicable Standards: IEC60079-0:2011, IEC60079-11:2011, IEC60079-28:2015 Certificate: IECEx FMG 15.0039X Ex ia op is IIC T4 Ga Degrees of protection: IP66 according to IEC60529:2013 Amb. Temp. (Tamb): 40 to 70 C (40 to 158 F) Uo = 5.88 V, Io = 613 ma, Po = 907 mw, Co = 5.82 μf, Lo = 25 μh VOUT (Terminal 1, 2) Uo = 23.1V, Io = 87 ma, Po = 450 mw, Co = 100 nf, Lo = 3 mh COMM (Terminal 3, 4) Ui = 30 V, Ii = 300 ma, Pi = 1 W (linear source), Ci = 20 nf, Li = 0 μh FS17 CS17 KS27 SS27 Apr. 14, 2017-00

5 Protocol code: M Item Description Code Factory Mutual (FM) ATEX IECEx United States Canada FM Intrinsically safe Approval (United States) Applicable Standards: Class 3600:2011, Class 3610:2010, Class 3810:2005, ANSI/ISA-60079-0-2013, ANSI/ISA-60079-11-2014, NEMA 250-2003, ANSI/IEC-60529-2004 (R2011) Intrinsically safe for Class I, II, III, Division 1, Groups C, D, E, F & G, Class I, Zone 0, in Hazardous Locations, AEx ia IIB Enclosure: IP66 and Type 4X, Temperature Class: T4, Amb. Temp. : 40 to 70 C (40 to 158 F) For connection to Class I, II, III, Division 1, Groups A, B, C, D, E, F & G, Class I, Zone 0, in Hazardous Locations, AEx ia IIC Uo = 5.88 V, Io = 483 ma, Po = 779 mw, Co = 5.82 μf, Lo = 25 μh Sensor Input (Terminal 1 to 4) Uo = 5.88 V, Io = 145 ma, Po = 213 mw, Co = 43 µf, Lo = 1.6 mh FM Intrinsically safe Approval (Canada) Applicable Standards: CAN/CSA-C22.2 No. 0-10 (R2015), CAN/CSA-C22.2 No. 94.1-07 (R2012), CAN/CSA-C22.2 No. 94.2-07 (R2012), CAN/CSA-C22.2 No. 60079-0:11, CAN/CSA-C22.2 No. 60079-11:14, CAN/CSA-C22.2 No. 60529-05 (R2015), CAN/CSA-C22.2 No. 61010-1-12 Ex ia [ia IIC] IIB T4 Ga Intrinsically safe for Class I, II, III, Division 1, Groups C, D, E, F & G Enclosure: IP66 and Type 4X, Temperature Class: T4, Amb. Temp.: 40 to 70 C (40 to 158 F) For connection to Class I, II, III, Division 1, Groups A, B, C, D, E, F & G Uo = 5.88 V, Io = 483 ma, Po = 779 mw, Co = 5.82 μf, Lo = 25 μh Sensor Input (Terminal 1 to 4) Uo = 5.88 V, Io = 145 ma, Po = 213 mw, Co = 43 µf, Lo = 1.6 mh ATEX Intrinsically safe Approval Applicable Standards: EN 60079-0:2012A11:2013, EN 60079-11:2012, EN 60079-28:2015 Certificate: FM 15ATEX0071X II 1 G Ex ia op is [ia IIC] IIB T4 Ga Degrees of protection: IP66 according to EN 60529:1991A1:2000A2:2013 Amb. Temp. (Tamb): 40 to 70 C (40 to 158 F) Uo= 5.88 V, Io = 483 ma, Po = 779 mw, Co= 5.82 μf, Lo = 25 μh Sensor Input (Terminal 1 to 4) Uo = 5.88 V, Io = 145 ma, Po = 213 mw, Co = 43 μf, Lo = 1.6 mh IECEx Intrinsically safe Approval Applicable Standards: IEC60079-0:2011, IEC60079-11:2011, IEC60079-28:2015 Certificate: IECEx FMG 15.0042X Ex ia op is [ia IIC] IIB T4 Ga Degrees of protection: IP66 according to IEC60529:2013 Amb. Temp. (Tamb): 40 to 70 C (40 to 158 F) Uo = 5.88 V, Io = 483 ma, Po = 779 mw, Co = 5.82 μf, Lo = 25 μh Sensor Input (Terminal 1 to 4) Uo = 5.88 V, Io = 145 ma, Po = 213 mw, Co = 43 µf, Lo = 1.6 mh FS17 CS17 KS27 SS27 Apr. 14, 2017-00

6 OPTIONAL SPECIFICATIONS (Connection Types) Item Description Code Connection device type* 1 SENCOM* 2 DT2 *1: When protocol code M is selected, specify the connection device. *2: FU20F-NPT, FU20F-FSM, FU24F-NPT, FU24F-FSM, SC25F-AGP25-120, SC25F-AGP25-225, SC25F-ALP25-120, SC25F-ALP25-225 OPTIONAL SPECIFICATIONS Item Description Code Protection cap* Metal waterproof cap CP Wired tag plate 316 SST tag plate wired onto module N4 *: When protection cap is not specified, dust-cap is attached. OPTIONAL ACCESSORIES Item Parts Number Description Battery pack assembly F9090FD* 1 Battery case, Lithium-thionyl chloride batteries* 2 2 pieces Batteries* 3 F9915NR Lithium-thionyl chloride batteries* 2, 2 pieces Battery case F9090GD* 4 Battery case only Magnet F9840PA For magnet switch operation *1: If you need F9090FC, please purchase F9090FD. F9090FD is a set of F9090FC and instruction manual. *2: Tadiran TL-5930/S *3: Alternatively, Tadiran SL-2780/S, TL-5930/S or VITZROCELL SB-D02 batteries can be purchased from your local distributor. *4: If you need F9090GC, please purchase F9090GD. F9090GD is a set of F9090GC and instruction manual. DIMENSIONS Direct mounting to electrical connection port (Protocol code: J) Unit: mm (approx. inch) 100 (3.94) 84 (3.31) 21 28 (1.10) 20 (0.79) (0.83) 12 (0.47) FN110 Grounding terminal 191 (7.52) Integral indicator 93 (3.66) 53 (2.09) 39 (1.54) Electrical connection Magnet switch 2 Magnet switch 1 Blind plug 31 (1.22) Clamp F01.ai * The FN110 is sold separately. June 10, 2016-00

2-inch pipe mounting (for horizontal piping) (Protocol code: J, M) 100 (3.94) 112 (4.41) 48 (1.89) 29 (1.14) 7 Unit: mm (approx. inch) FN110 Grounding terminal Integral indicator Blind plug 269 (10.59) 79 (3.11) 93 (3.66) Electrical connection 148 (5.83) Magnet switch 2 Magnet switch 1 Mounting bracket 47 (1.85) 40 (1.57) 80 (3.15) 2-inch pipe 93 (3.66) F02.ai 2-inch pipe mounting (for vertical piping) (Protocol code: J, M) 112 (4.41) 48 (1.89) 29 (1.14) FN110 100 (3.94) Unit: mm (approx. inch) 170 (6.69) 73 (2.87) 47 (1.85) Grounding terminal 93 (3.66) Integral indicator 80 (3.15) 106 (4.17) Blind plug 47 (1.85) 50 (1.97) Electrical connection Magnet switch 1 Magnet switch 2 Mounting bracket 2-inch pipe F03.ai June 10, 2016-00

8 Infrared Configuration Pin Assignment of FN110 Connection Terminal 3 2 1 5 4 Pin Signal 1 Frame Ground* 2 Signal Ground 3 Power Supply Transmit/Receive 5 Data negative F05.ai * Wired to the grounding terminal inside the FN310 housing. 4 Transmit/Receive Data positive Infrared port F04.ai Input Terminal Configurations F06.ai Terminal 1 2 2-wire Power Supply and Input Signal Power Supply and Input Signal - Signal One-to-one Connection 4-wire (Active) No Connection No Connection 4-wire (Passive) Loop Power and Input Signal Loop Power and Input Signal - 4-20 ma Loop Connection No Connection No Connection 3 No Connection Input Signal No Connection Input Signal 4 No Connection Input Signal - No Connection Input Signal - Frame Ground [Protocol code: M] F07.ai Terminal Signal 1 Power Supply 2 Power Supply Gnd 3 Data 4 Data - 5 No Connection 6 No Connection Frame Ground Apr. 22, 2016-00

9 Input Wiring One-to-one Connection 2-wire 4-wire (Active) 4-wire (Passive) HART F08.ai 250Ω HART External HART External Power Power Source Source F09.ai F10.ai * Connect the FN310 and HART devices directly. 4-20 ma Loop Connection 2-wire 4-wire (Active) 4-wire (Passive) Distributor 250Ω HART F11.ai Distributor 250Ω HART External Power Source F12.ai Distributor 250Ω HART External Power Source F13.ai [Protocol code: M] Connection Type Wiring Diagram 5 6 DT2 87 (brown) 86 (white) 84 (green) 83 (yellow) 82 (black) WU11 SENCOM cable SENCOM F14.ai July 11, 2018-00

10 < Ordering Information > Specify the following when ordering. 1. Model, suffix codes, and option codes. 2. Tag Number (if required) Specify Tag number (up to 16 letters) to be printed on the nameplate and tag plate. The characters can be specified using alphanumeric and the symbols, [ - ] and [ _ ]. < Related Products General Specifications > Field Wireless System Overview: Refer to GS 01W01A01-01EN Field Wireless Communication Module FN110: Refer to GS 01W03B01-01EN Field Wireless Management Station YFGW410: Refer to GS 01W02D01-01EN Field Wireless Access Point YFGW510: Refer to GS 01W02E01-01EN Field Wireless Access Point YFGW520: Refer to GS 01W02E02-01EN FieldMate Versatile Management Wizard: Refer to GS 01R01A01-01E Plant Resource Manager (PRM): Refer to GS 30B05A10-01EN SENCOM FU20F/FU24F/SC25F Digital ph/ ORP sensor: Refer to GS 12B06J03-04E-E < Trademark > All brand or product names of Yokogawa Electric Corporation in this document are trademarks or registered trademarks of Yokogawa Electric Corporation. All other company brand or product names in this document are trademarks or registered trademarks of their respective holders. In this document, trademarks or registered trademarks are not marked with or. < Information on WEEE Directive > EU WEEE (Waste Electrical and Electronic Equipment) Directive is only valid in the EU. This instrument is intended to be sold and used only as a part of equipment which is excluded from WEEE Directive, such as large-scale stationary industrial tools, a large-scale fixed installation and so on, and, therefore, subjected to the exclusion from the scope of the WEEE Directive. The instrument should be disposed of in accordance with local and national legislation/regulations. Subject to change without notice. July 11, 2018-00