Maximum Light Transmission. Pupil-independent Light Distribution. 3.75D Near Addition Improved Intermediate Vision

Similar documents
Wide Diopter Range and Different Haptic Platforms

Glistening-Free Hydrophobic Acrylic IOL. Glistening-Free Hydrophobic Acrylic IOL

NEW THE WORLD S FIRST AND ONLY SINUSOIDAL TRIFOCAL IOL

Improving Lifestyle Vision. with Small Aperture Optics

AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients

NEW. AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients

Dr. Magda Rau Eye Clinic Cham, Germany

PROGRESSIVE VISION WITHIN FULL ACCOMMODATIVE RANGE

IOL Types. Hazem Elbedewy. M.D., FRCS (Glasg.) Lecturer of Ophthalmology Tanta university

Long-term quality of vision is what every patient expects

Evolution of Diffractive Multifocal Intraocular Lenses

Clinical Evaluation 3-month Follow-up Report

Centre Hospitalier Universitaire et Psychiatrique de Mons-Borinage. B-Flex Multifocal. Dr Emmanuel Van Acker Belgium

SEE BEYOND WITH FULLRANGE OPTICS. Developed by Hanita Lenses

day night convinced supreme contrast sensitivity THE IOL FOR DAY & NIGHT

NOW. Approved for NTIOL classification from CMS Available in Quar ter Diopter Powers. Accommodating. Aberration Free. Aspheric.

Unique Aberration-Free IOL: A Vision that Patients

Raise your expectations. Deliver theirs.

Crystalens AO: Accommodating, Aberration-Free, Aspheric Y. Ralph Chu, MD Chu Vision Institute Bloomington, MN

Choices and Vision. Jeffrey Koziol M.D. Thursday, December 6, 12

The design is distinctive. The outcomes are clear. Defocus tolerance 1 Glistening-free performance 1,2 Predictable outcomes 1

Clinical Update for Presbyopic Lens Options

Choices and Vision. Jeffrey Koziol M.D. Friday, December 7, 12

Product Portfolio. Sulcoflex Pseudophakic Supplementary IOLs. Your skill. Our vision.

Roadmap to presbyopic success

Product Portfolio. Sulcoflex Pseudophakic Supplementary IOLs

THE ASPHERIC PRELOADED INJECTION

*Simulated vision. **Individual results may vary and are not guaranteed. Visual Performance When It s Needed Most

Visual and Optical Performances of Multifocal Intraocular Lenses with Three Different Near Additions: 6-Month Follow-Up

Quality of Vision With Multifocal Progressive Diffractive Lens: Two-Year Follow-up

Multifocal Intraocular Lenses for the Treatment of Presbyopia: Benefits and Side-effects

Multifocal Progressive Diffractive Lens to Improve Light Distribuition and Avoid Light Loss: Two Years Clinical Results

HOYA aspherical IOL with ABC (Aspheric Balanced Curve) Design

Special Publication: Ophthalmochirurgie Supplement 2/2009 (Original printed issue available in the German language)

Aberrations Before and After Implantation of an Aspheric IOL

Corneal Asphericity and Retinal Image Quality: A Case Study and Simulations

CONTENTS. HYDROPHILIC IOLs. Bi-Flex PIL-MA hydrophilic preloaded P / PY 677PT / PTY 677PMY 677PMTY. Bi-Flex HL...

Causes of refractive error post premium IOL s 3/17/2015. Instruction course: Refining the Refractive Error After Premium IOL s.

Sulcoflex. For when perfection is the only option! Pseudophakic Sulcus Fixated Secondary IOLs. Sulcoflex Aspheric. Sulcoflex Toric

ASPIRA PUBLICATION LIST

Treatment of Presbyopia during Crystalline Lens Surgery A Review

Soft CL Multifocals Design and Fitting. Soft Multifocal Lens Designs. Issues Surrounding Multifocals. Blur Interpretation. Simultaneous Vision Designs

RayOne Hydrophobic IOL. New design. New standard MADE IN UK

ROTATIONAL STABILITY MAKES THE DIFFERENCE

Accommodating IOL s History and Clinical Management

Visual Outcomes of Two Aspheric PCIOLs: Tecnis Z9000 versus Akreos AO

Comparison between clinical results of two diffractive multifocal lenses with the same platform but different additions

Clinical Evaluation 3-month Follow-up Report

Not everyone can do this. Introducing RayOne with patented Lock & Roll TM technology for the smallest fully preloaded IOL incision

Intraocular lens Difficulties

Ocular Scatter. Rayleigh Scattering

The Appearance of Images Through a Multifocal IOL ABSTRACT. through a monofocal IOL to the view through a multifocal lens implanted in the other eye

Customized intraocular lenses

7 DO IT. A SAFER WAY TO TRIFOCALITY * : ELEVATED PHASE SHIFT (EPS) ** 7 DIFFRACTIVE RINGS FOR OPTIMAL LIGHT DISTRIBUTION AND LESS DISTURBANCE

Forget Most Everything! The Surgical Management of Presbyopia 2/23/2016. Refraction vs. Diffraction. Presbyopic IOL s Patient Expectations

Diffractive Optics. Multifocal Lenses. Correction of Pseudophakic Presbyopia with Multifocal IOLs. Basic Designs

Patient information. Your options for cataract treatment Enjoy clear vision at all distances with multifocal IOLs

THE XTRAFOCUS IS AN ELEGANT SOLUTION TO COMPLEX CASES.

Design and qualification of a diffractive trifocal optical profile for intraocular lenses

Retinal stray light originating from intraocular lenses and its effect on visual performance van der Mooren, Marie Huibert

Preloaded. PreciSAL. EZ Toric

COMPARISON OF THE MEDICONTUR 860FAB

Corporate Perspective Alcon Unanswered Technical Challenges that Still Need to be Overcome

Principles and clinical applications of ray-tracing aberrometry (Part II)

FOR PRECISE ASTIGMATISM CORRECTION.

EDoF IOL. ZEISS AT LARA 829MP Next generation Extended Depth of Focus Intraocular Lens. NEW EDoF IOL from ZEISS

10/25/2017. Financial Disclosures. Do your patients complain of? Are you frustrated by remake after remake? What is wavefront error (WFE)?

Choosing the Proper Power for the IOL. Brannon Aden, MD Miles H. Friedlander, MD, FACS

The Aberration Structure of the Keratoconic Eye

Refractive Power / Corneal Analyzer. OPD-Scan III

Advances in the design and

Optical Characteristics of Next Generation Dual Optic IOL

The Unique Mu l t i f o c a l S i l i c o n e H y d r o g e l

Design of a Test Bench for Intraocular Lens Optical Characterization

Comparison of higher order aberrations with spherical and aspheric IOLs compared to normal phakic eyes

I N M A D E F R A N C E. Hydrophobic monofocal NEW QUALITY SAFETY STABILITY TECHNICAL BROCHURE

Maximising Treatment Outcomes with Premium IOL Technology. Saturday 13 September 2014 XXXII Congress of the ESCRS London, UK.

Assessing Visual Quality With the Point Spread Function Using the NIDEK OPD-Scan II

In Vitro Strehl Ratios with Spherical, Aberration-Free, and customized spherical aberration-correcting METHODS

WaveMaster IOL. Fast and accurate intraocular lens tester

Wavefront Aberrations in Eyes With Acrysof Monofocal Intraocular Lenses

EDOF-IOLs: Are they all the same?

Financial disclosure. Alcon, Zeiss, J&J AMO, Physiol, Thea, Allergan, Santen, Dompe, Cutting Edge) Race for Progress!

The Miracle of Pi in Eye. Rajesh Khanna, MD

The Aberration-Free IOL:

Surgical data reveals that Q-Factor is important for good surgical outcome

Postoperative Wavefront Analysis and Contrast Sensitivity of a Multifocal Apodized Diffractive IOL (ReSTOR) and Three Monofocal IOLs

Theoretical Considerations

CATARACT SURGERY AND DEPTH OF FIELD (D.O.F.)

PATIENT SELECTION THE RIGHT PATIENT UNDERPROMISE AND OVERDELIVER THE PERFECT SPECTACLE FREE TREATMENT. Desires Less Dependence on glasses

LEAVE A LEGACY OF VISUAL FREEDOM. TECNIS PRESBYOPIA-CORRECTING IOLs

Multifocal IOL Basics

THE PRIMARY goal in intraocular

Sirius TOMOGRAPH AND CORNEAL TOPOGRAPHER

LEAVE A LEGACY OF VISUAL FREEDOM. TECNIS PRESBYOPIA-CORRECTING IOLs

Energy efficiency of a new trifocal intraocular lens

Role of Asphericity in Choice of IOLs for Cataract Surgery


József Győry. Veszprem, Hungary

Technicians & Nurses Program

Transcription:

Multifocal

Maximum Light Transmission Pupil-independent Light Distribution Better Visual Quality Increased Contrast Sensitivity 3.75D Near Addition Improved Intermediate Vision Visual Performance After Implantation Ring Transition Zones Exceptional Optic Engineering Enhanced Visual Acuity for All Distances Limited Photic Phenomena Square Edge and Aspheric Design

Maximum Light Transmission Better Visual Quality Not all diffractive IOLs are the same. Reviol s unique Active-Diffractive zone design provides excellent light transmission at maximum range under any light condition. Pupil-Independent Light Distribution Increased Contrast Sensitivity Reviol s Active-Diffractive optic preserves a better balance of 60% far and 40% near focus at 6mm pupil aperture. Balanced light distribution under any light condition increases contrast sensitivity. Diffractive Zones of Reviol 80% 70% 60% 50% 40% 30% 20% 10% 0% 2,00 2,50 3,00 3,50 4,00 4,50 5,00 5,50 6,00 Pupil Size mm Reviol s Light Distribution Far Near The performance of multifocal IOLs depends on their establishment of diffractive zones. The number, height, interval, and width of the rings affect patients' total visual outcomes under mesopic conditions. Diffractive multifocal IOL engineering is based on balanced light energy between foci. Narrow rings increase the near addition. Conversely, higher steps enable transfer of more energy to near focus 1. Decreased contrast sensitivity in mesopic conditions has been reported in pupil-dependent multifocal IOLs 2. A light distribution change of 90% for far focus and 10% for near focus at 6 mm pupil diameter explains this phenomenon. Lower energy transfer to near focus causes patients' poor visual acuity 3. References 1- Portney V., Light distribution in diffractive multifocal optics and its optimization. J Cataract Refract Surg 2011; 37:2053-2059. 2- de Vries NE, Nuijts RM. Multifocal intraocular lenses in cataract surgery: literature review of benefits and side effects. J Cataract Refract Surg. 2013 Feb;39(2):268-78. 3- Petermeier K, Messias A, Gekeler F, Szurman P. Effect of +3.00 diopter and +4.00 diopter additions in multifocal intraocular lenses on defocus profiles, patient satisfaction, and contrast sensitivity. J Cataract Refract Surg. 2011 Apr;37(4):720-6. 1

3.75D Near Addition Improved Intermediate Vision 3.75D near addition in Reviol s Active-Diffractive Optic has the appropriate balance to provide better intermediate visual acuity 4. Visual Performance After Implantation Enhanced Visual Acuity for All Distances As demonstrated in the defocus curve graphic, Reviol s Active-Diffractive optic offers better intermediate vision than Apodized +4.0D multifocal IOLs, and better near visual performance than Apodized +3.0D multifocal IOLs 5. MTF FAR MTF INTERMEDIATE MTF NEAR MTF Pwr MTF Pwr MTF Pwr 0.66 21.00 0.47 23.50 0.60 24.75 1.00 1.6 1.4 1.2 0.62 0.47 0.28 0.04 1 0.8 0.6 0.4 0.2 0 Apodized Multifocal +3.0D Near Addition Reviol Multifocal +3.75D Near Addition Apodized Multifocal +4.0D Near Addition -0.20 21.00 23.50 24.75 Power, D Defocus Curve *There were statistically significant differences in near and intermediate visual acuities among three groups. (P < 0.05) Near addition is crucial in energy distribution through near to distance focus. Insufficient near addition results in inadequate disparity between foci, causing blurred vision at intermediate focus. Excessive near addition eliminates focus overlapping and provides sharp near and distance vision. On the other hand reduced visual performance may result, causing difficulties in patient adaptation 3. The defocus curve was determined in a comparative study on 130 eyes of 87 patients. The study compared performances of Reviol +3.75D near addition, an apodized multifocal IOL +3.0D near addition, and an apodized multifocal IOL +4.0D near addition. 5 References 3- Petermeier K, Messias A, Gekeler F, Szurman P. Effect of +3.00 diopter and +4.00 diopter additions in multifocal intraocular lenses on defocus profiles, patient satisfaction, and contrast sensitivity. J Cataract Refract Surg. 2011 Apr;37(4):720-6. 4- Can I., Ceran BB., Soyugelen G., Takmaz T. Comparison of clinical outcomes with 2 small-incision diffractive multifocal intraocular lenses. Journal of Cataract & Refractive Surgery 2012 Vol 38 No1 5- Data on file. 2

See the Difference Ring Transition Zones Limited Photic Phenomena Reviol s progression zones are rounded in a unique manufacturing process. Exceptional Optic Engineering Aspheric Design Ultra Definition optic design corrects spherical aberrations coming from cornea. Reviol IOLs have a slight negative asphericity which neutralizes positive spherical aberration of the cornea while preserving the depth of focus. Photic Phenomena Improved Vision Ultra Definition Aspheric Optic Sharper transition zones interact with photic phenomena as light refracts wildly. Corneal topography measurements on 71 cataract patients have shown that the average spherical aberration of the human cornea is +0.27 microns. With spheric IOL implantation, total ocular spheric aberration becomes increasingly positive. Poor contrast sensitivity has been reported in many cataract patients after implantation of spheric IOLs 6, 7. Advantages of Ultra Definition Design Improved contrasts under mesopic conditions Preserved depth of focus Less sensitive to decentration References 6- Holladay JT, Piers PA, Korayni G, et al. A new intraocular lens design to reduce spherical aberration of pseudophakic eyes. J Refract Surg. 2002, 18 (6):683-691. 7- Belluci R, Morselli S, Piers P. Comparison of wavefront aberrations and optical quality of eyes implanted with five different intraocular lenses. J Refract Surg. 2004 Jul-Aug;20(4):297-306. 3

7 360 All Enhanced Square Edge Real PCO Barrier Reviol s innovative edge design greatly reduces PCO risks by creating a geometric and mechanical barrier against cell proliferation. Recent studies conclude that the most important IOL-related factor in preventing PCO formation is a square edge on the posterior optic surface, exerting a mechanical barrier effect 8,9. References 8 - Kohnen T, Maqdowski G, Koch DD. Scanning electron microscopic analysis of foldable acrylic and hydrogel intraocular lenses. J Cataract Refract Surg 1996; 22:1342-1350. 9- Werner L, Mamalis N, Pandey SK, et al. Posterior capsule opacification in rabbit eyes implanted with hydrophilic acrylic intraocular lenses with enhanced square edge. J Cataract Refract Surg 2004; 30:2403-2409. 4

MFM 611 BB MFM 611 BB T MFM 611 Material Hydrophobic surface, acrylic with 25% water content, UV filter Optic Size 6.00 mm Optic Design Biconvex Haptic Size 11.00 mm Haptic Design Plate Haptic Angle 0 Recommended Ac. A Constant 118.0 Recommended Op. A Constant Srk-T : 118.3 - Srk-II : 118.5 Diopter Power Range From 0.0D to +32.00D (0.50D increments) Special Production From +32.50D to +45.00D (0.50D increments) Refractive Index Wet 20 C /35 C 1.462 / 1.462 ± 0.002 Recommended Injector & Acrijet Green 1.8 (Up to 25.0D) Cartridge System Acrijet Green 2.0 (Up to 28.0D) Acrijet Green 2.2 (Up to 30.0D) Material Hydrophobic surface, acrylic with 25% water content, UV, violet, and blue filter Optic Size 6.00 mm Optic Design Active-Diffractive Multifocal Haptic Size 11.00 mm Haptic Design Plate Haptic Angle 0 Recommended Ac. A Constant 118.0 Recommended Op. A Constant Srk-T:118.3 - Srk-II:118.5 Diopter Power Range From 0.0D to +32.00 D (0.50D increments) Special Production From +32.50D to +45.00D (0.50D increments) Refractive Index Wet 20 C /35 C 1.462 / 1.462 ± 0.002 Recommended Injector & Acrijet Green 1.8 (Up to 25.0D) Cartridge System Acrijet Green 2.0 (Up to 28.0D) Acrijet Green 2.2 (Up to 30.0D) Material Hydrophobic surface, acrylic with 25% water content, UV, violet, and blue filter Optic Size 6.00 mm Optic Design Active-Diffractive Multifocal Toric Haptic Size 11.00 mm Haptic Design Plate Haptic Angle 0 Recommended Ac. A Constant 118.0 Recommended Op. A Constant Srk-T:118.3 - Srk-II:118.5 Diopter Power Range Spheric: From 0.0D to +32.00D (0.50D increments) Cylindric: From +1.00D to +10.00D (0.50D increments) Refractive Index Wet 20 C /35 C 1.462 / 1.462 ± 0.002 Recommended Injector & Acrijet Green 1.8 (Up to Sph 25.0D Cyl 5.0D) Cartridge System Acrijet Green 2.0 (Up to Sph 28.0D Cyl 5.0D) Acrijet Green 2.2 (Up to Sph 30.0D Cyl 5.0D)

Acriva UD Reviol MFM 611 Acriva UD BB Reviol BB MFM 611 Acriva UD BB Reviol Toric BB T MFM 611 VSY Biotechnology BV Strawinskylaan 1143, 1077 XX Amsterdam - The Netherlands T: +31 (0) 62 147 38 46 F: +31(0) 20 782 00 02 info@vsybiotechnology.com www.vsybiotechnology.com IOL CARTRIDGE VISCOELASTICS & INJECTOR 2018 VSY Biotechnology BV 03/18 MKT Rev-06