Installation Instructions

Similar documents
ControlNet Accessory Specifications

ControlNet Modular Repeater Medium Distance Fiber Module

ControlNet Ex Tap Terminator Installation Instructions

ControlNet Ex Modular Repeater Adapter & Fiber Repeater Module

ControlNet Ex Modular Repeater Adapter & Fiber Repeater Module

FOUNDATION Fieldbus Junction Box

Allen-Bradley Spares

CATALOG. Network Access & Connectivity

FLEX I/O and FLEX Integra

1715 Redundant I/O System Specifications

XM Monitoring Modules Specifications

SISNet Distance Extenders

SLC 500 RTD/Resistance Input Modules

P1-04DAL-1 Analog Output

FP-RTD-124 AND CFP-RTD-124. Features. FieldPoint Operating Instructions. Eight-Channel Four-Wire RTD and Resistance Input Modules

FLEX Ex System Certification

1715 Redundant I/O System Specifications

FLEX Ex Power Supplies

Foundation Fieldbus Redundant Junction Box

A local 3.5 mm network jack allows a convenient way to connect an installation or diagnostic tool to the network without disconnecting any wires.

FP-RTD-122. Features OPERATING INSTRUCTIONS. 8-Channel, 3-Wire RTD and Resistance Input Module

DeltaV SISnet Fiber Components

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

G.703 Balun Module Panel Unit G.703 Balun Module G.703 Balun Chassis

Modicon Quantum 140 NRP /01 Fiber Converter Modules User Guide

The I-2532 CAN to Fiber Converter

Sixteen Port PoE+ Receiver Hub Model NV-ER1816i

8 Input/8 Output AC Block I/O Module

FLEX Ex V ac In/Quad-Ex dc Out Power Supply

P1-04ADL-2 Analog Input

SISNet Repeater. SISNet Repeater. Introduction. DeltaV SIS Product Data Sheet. Dedicated safety communications. Full communications redundancy

24V dc Analog Block I/O Module

NI PXI-2555 Specifications

2mm metric system INTRODUCTION MAIN FEATURES

DeltaV SIS Hardware Carriers

Amphenol RF. Mini-BNC Mini-BNC Connectors. Mini-BNC. Description. Features/Benefits. Applications

NI PXI-2557 Specifications

Selection guide. Communication accessories. Communication accessory selection guide. Characteristics

Sixteen Port PoE+ Receiver Hub Model NV-ER1816i

SLC 500 RTD/Resistance Input Module

P1-04THM Analog Input

NI PXI-2797 Specifications 40 GHz 6 1 Terminated 50 Ω Multiplexer

Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter

FP-RTD-122 AND CFP-RTD-122. Features. FieldPoint Operating Instructions. Eight-Channel Three-Wire RTD and Resistance Input Modules

FP-RTD-122 and cfp-rtd-122

FP-DO-403 and cfp-do-403

Compact I/O RTD/Resistance Input Module

DeltaV SISnet Fiber Components

DeltaV SIS TM Hardware Carriers

200 Watt Passive Shunt Module

OPERATING INSTRUCTIONS NI Port, Low-Speed/Fault Tolerant CAN Module

Medium Converter FL MC 10BASE-T/FO G850

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

UniStream Uni-I/O Modules

SLC 500 System Overview

Modular Plug Connectors compliant to Cat.6 A Standard

FP-DO-400 and cfp-do-400

Dielectric Material. Cable Type

Asia-Pacific North America Europe, Middle East Bel Power Solutions, Inc. BCD.

PRetrans Table of contents

PROFIBUS HUB REPEATER

SONORA DESIGN DIRECTV MFH2 (6) INPUT PRODUCTS

Allen-Bradley. User Manual. Very High Speed Counter Module. (Cat. No VHSC) Allen-Bradley Spares

Model NV-ER1804 TBus Four Port Receiver

Data sheet C6 A modul K 180 jack - Keystone style

Wireless Interface RAD-ISM-900-SET-BD-BUS Two-way (point-to-point) Monitoring and Control with Expandable I/O Options User Manual

1769 Compact I/O Modules Specifications

CCITT G.703 Baluns HC-GB- MB8S. Shielded RJ45 Jack to Male BNC Connector. STANDARD TYPE Ordering Information

Low Frequency Velocity Sensor

EP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442

Designing external cabling for low EMI radiation A similar article was published in the December, 2004 issue of Planet Analog.

SCXI MHz Quad 8x1 50 Ω Multiplexer

Underwriters Labs (UL) Approved Barriers

[ tima-datasheet-en v11.1 ]

27/04/2015

4 Channel 4~20mA / 0~10VDC Analog DIN Fiber Link System

NI PXI-2530 Specifications

MONITOR BRACKETS CCTV SYSTEMS. BT7510S Ex GST Inc GST. BT7511S Ex GST Inc GST. BT7512S Ex GST Inc GST. BT7518S Ex GST Inc GST. BT7513S Ex GST Inc GST

- 1. Allen-Bradley. User Manual. Very High Speed Counter Module. (Cat. No VHSC)

NI PXI-2521 Specifications 40-Channel DPST Relay Module

1769 Compact I/O Modules Specifications

Model NV-ER1808i TBus Eight Port Receiver Hub FRONT

NI PXI/PXIe-2540 Specifications

User Manual CTP4/8/16

SPLIT.CONVERTER. User's Manual. Version 2.0

Frequency Distribution System Distribution Amplifier Model 8140

Operation. Displayed channel. Measuring range. Status indication/ remote control Key lock Measuring mode/ time constant. Scale.

PHOENIX CONTACT

Data Sheet. Four Port PoE+ Receiver Model NV-ER1804. Application Example: Features:

FOR POWER AND DATA HEAVY DUTY CONNECTOR SYSTEM

Functional safety supplement L B. SiGNUM angle and linear analogue encoder systems

UniStream Uni-I/O Modules

NI PXI/PXIe-2541 Specifications 300 MHz Ω Matrix

NYULMC AMBULATORY CARE CENTER FIT-OUT PHASE 1 Perkins & Will Architects PC 222 E 41st ST, NYC Project: Issued for GMP March 15, 2017

NI PXI-2520 Specifications 80-Channel SPST Relay Module

Data sheet C6 A modul K 90 jack - keystone style

Amphenol RF. MMCX Micro-Mate (MMCX) Connectors MMCX. Description. Features/Benefits. Applications

3-FIBMB2 Fiber Optic Interface Module Installation Sheet

Workstation Outlets GigaFlex PS6+ Modules Category 6

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.

Transcription:

Installation Instructions ControlNet Modular Repeater Dual Copper Module Catalog Number This document describes how to install and apply the dual copper repeater module. Topic: Page: Important User Information 2 Rockwell Automation Support 4 European Communities (EC) Directive Compliance 5 About the Dual Copper Repeater Module 6 Mount the Dual Copper Repeater Module 7 Utilize Trunk Line Terminators 10 Remove the Module from the DIN Rail 11 Wire the Dual Copper Repeater Module 12 Series Topology 14 Star Topology 15 Trunk Extender Topology 16 Hub/Star Topology 17 Slip-ring Isolation Topology 18 Constraints of the COAX Segment 19 Status Indicators 20 Related Publications 21 Mount Dimensions 21 CSA Hazardous Location Approval 22 Specifications 24

6 ControlNet Modular Repeater Dual Copper Module About the Dual Copper Repeater Module Use this copper repeater module when the: design of the network requires a hub based topology segment requires a greater copper distance design requires a isolated segment The copper repeater module allows multiple 1000m copper segments with up to five repeaters in a series. You can communicate to any two nodes through a maximum of 5 repeaters. See pages 16-19 for topology examples and segment length constraints. The module provides two copper channels and activity LED indicators for each channel. The figure below identifies the components of the module: Figure 1 The Dual Copper Module The left side of the module (not shown here) also contains a backplane connector. Indicators Right-side backplane connector with protective cover Channel 1 Module coax port Channel 2 lock tab coax port 75 Ω BNC Trunk line terminators (1786-XT) Important: You must terminate unused channels to maintain the integrity of your network. 42210

10 ControlNet Modular Repeater Dual Copper Module Utilize Trunk Line Terminators When you are not going to connect a trunk line to a channel on the repeater module, connect a 75 Ω trunk line terminator (1786-XT) to maintain the integrity of your network. Figure 2 Trunk Line Terminators Be certain to ground the DIN rail with a minimum #14 AWG wire. Protective backplane cap The left side of the module (not shown here) also contains a backplane connector. Terminator DIN rail 42218 If: you are not going to use a channel you connect another repeater module or repeater adapter to the right backplane connector you are not going to connect a module to the right backplane connector the module is in the right-most position Then: keep the terminator on an unused channel for optimal network performance remove the protective backplane cap and save the cap for future use leave the backplane cap attached attach a DIN rail latch

12 ControlNet Modular Repeater Dual Copper Module Wire the Dual Copper Repeater Module If you only need to wire one channel, you can use either channel 1 or channel 2. To wire the module for channel 1: 1. Connect the copper to port #1. a. Align the knob of the BNC cable connector with the locks of the BNC module connector, and insert the connector into channel 1. Figure 3 Wire the copper repeater module T-port tap BNC connector 75 Ω terminator 42211 b. Twist the BNC connector until the bayonet lug is locked into place. 2. To connect channel 2, repeat Step 1.

14 ControlNet Modular Repeater Dual Copper Module Series Topology Figure 4 The s in a series topology PLC Connect 1786-RPA to a 24 V dc Class 2 power supply. Twist the wire 6 times per foot to reduce the possibility of noise coupling. 1786-RPA 1786-RPA CH 1 CH 2 CH 1 CH 2 ACN ACN 42212

ControlNet Modular Repeater Dual Copper Module 15 Star Topology Figure 5 illustrates a star configuration offering a 16 port hub topology. Figure 5 The s in a star configuration 1786-RPA 16 nodes, 2 1786-RPA s in series with a maximum of 4 s 1786-RPA 42213

16 ControlNet Modular Repeater Dual Copper Module Trunk Extender Topology Figure 6 Trunk Extender Topology PLC 1786-RPA PLC 1786-RPA 42214

ControlNet Modular Repeater Dual Copper Module 17 Hub/Star Topology Figure 7 Hub/Star Topology PLC 1786-RPA 1786-RPFM 1786-RPFS Rx Tx Rx Tx Rx Tx Rx Tx 1786-RPA 1786-RPFM Rx Tx Rx Tx ACN 1395 Digital DC Drive 1336 Force AC Drive 42215

18 ControlNet Modular Repeater Dual Copper Module Slip-ring Isolation Topology Figure 8 Slip-ring Isolation Topology 1786-RPA CH 1 CH 2 Important:Never connect the copper cable between channel 1 or channel 2 on the same repeater module, even between channels from different modules on the same repeater. Slip-rings ACN ACN 42216

segment length m (ft.) ControlNet Modular Repeater Dual Copper Module 19 Constraints of the COAX Segment The total allowable length of a segment that contains standard RG-6 quad shield coaxial cable depends upon the number of taps in your segment. There is no minimum trunk-cable section length requirement. The maximum allowable total length of a segment is 1000m (3280ft) with two taps connected. Each additional tap decreases the maximum length of the segment by 16.3m (53ft). The maximum number of taps allowed on a segment is 48 with a maximum length of 250m (820ft). Figure 9 Maximum Segment Length 1000 (3280) 750 (2460) 500 (1640) 250 (820) 30014-m 2 16 32 48 number of taps maximum allowable segment length = 1000m (3280ft) - 16.3m (53.4ft) X [number of taps - 2] COAX Segment Constraint Example If your segment requires 10 taps, the maximum segment length is: 1000m (3280ft) - 16.3m (53.4ft) x [10-2] 1000m (3280ft) - 130.4m (427.7ft)) = 869.6m (2852.3ft) If you install a repeater, you can increase the total trunk-cable length or number of taps. When you install a repeater you create another segment. The amount of high-flex RG-6 cable (1786-RG6F) you can use in a system is less than the amount of standard RG-6 cable, so you should keep high-flex cable use to a minimum. Use BNC bullet connectors to

20 ControlNet Modular Repeater Dual Copper Module isolate areas that require high-flex RG-6 cable from areas that require standard RG-6 cable; this allows the high-flex RG-6 section to be replaced before flexture life is exceeded. Use this example when the attenuation of the cable (1786-RG6F High Flex) is: 10MH > 5.99dB/1000 trunk length = 20.29 (# of taps *.32/ COAX attenuation) For more information on the installation of a coax segment, see the ControlNet Coax Media Planning and Installation Manual, publication CNET-IN002A-US-P. Status Indicators The figure below identifies indicators on the module: Channel 1 status Channel 2 status 42219 The table below defines Channel 1 and Channel 2 status indications: Status Indicator: Off Green Flashing Green/Off Probable Cause: No power or module faulted Channel operational No data activity on associated channel

ControlNet Modular Repeater Dual Copper Module 21 Related Publications The table below lists publications that you may want to refer to for additional information: Publication: Industrial Automation Wiring and Grounding Guidelines Publication Number: 1770-4.1 ControlNet Coax Tap Installation Instructions 1786-5.7 ControlNet Coax Media Planning and Installation Manual ControlNet Cable System Component List CNET-IN002A-US-P AG-2.2 Mount Dimensions The figure below provides the mount dimensions for the module. Figure 10 The Mount Dimensions 4.44in (111mm) 4.0in (100mm) 2.76in (69mm) 3.6in (90mm) 4.048in (101.2mm) 42217

24 ControlNet Modular Repeater Dual Copper Module Specifications The table below provides specifications for the module: Specifications Communication Rate Indicators Backplane Power Requirements 5M bits/s Channel 1 Status - Green Channel 2 Status - Green 400 ma @ 5 V dc Class 2 from 1786-RPA Environmental Conditions Operating temperature 0 to 60 C (32 to 140 F) Storage temperature -40 to 85 C (-40 to 185 F) Relative humidity Shock operating width Non-operating width 5 to 95% without condensation 30 g peak acceleration, 11(+-1)ms pulse 50 g peak acceleration, 11(+-1)ms pulse Vibration Tested 5 g @ 10-500Hz per IEC 68-2-6 Copper Type 62.5/125 micron Standard Quad RG6 Cable Rockwell Automation Belden 1786-RG6 3092A Comm/Scope 5060

ControlNet Modular Repeater Dual Copper Module 25 Specifications Communication Rate 5M bits/s High Flex RG6 Cable Rockwell Automation Belden Comm/Scope Agency Certification (when product or package marked) 1786-RG6F/A and 1786-RG6F/B YR28890 5060F Listed Industrial Control Equipment Certified Process Control Equipment Certified Class I, Division 2, Groups A, B, C, D Marked for all applicable directives Marked for all applicable acts N223