KAL-K. Electronic Flow Monitor. for liquids. Range: approx cm/s. p max : 100 bar. Temperature of medium: C Option: 0...

Similar documents
Electronic Flow Monitor

Level Sensors Reed Contact Chain

Liquid Level Switches

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15...

Magnetic Inductive Flowmeter

BGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases

LTS. Resisitve Temperature Sensor hygienic design. Temperature. Measuring range: C Accuracy Class A according to DIN IEC 751 p

Full Metal Variable Area Flowmeter and Counter Model BGF

LCI. Inductive Conductivity/ Concentration and Temperature Transmitter. Compact or separate version

DUK. Ultrasonic Flowmeter/ -Monitor/-Counter/-Dosing Unit

Coriolis Mass Flow Meter Model TM

Coriolis Massflowmeter

Electromagnetic flowmeter in all metal design Model MIM

DVZ. Vortex Flowmeter Compact. for low viscosity liquids

KDS. All Metal Variable Area Flowmeter. for Liquids and Gases

COMPACT-LINE. Transmitter for ph-value

TUR. Turbine Wheel Flowmeter. Plastic Model for Liquids. Measuring Ranges: GPM or GPM (Water)

Temperature Transmitters

NGR. Guided Wave Radar Level Transmitter

DUK. Compact Ultrasonic Flowmeter

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22

TME. Coriolis Massflowmeter. for liquids and gases kg/h kg/h water. p max. : PN40 t max : C

COMPACT-LINE. KOBO-pH Transmitter for ph-value Model APM-Z

COMPACT-LINE. KOBO-RP Transmitter for ORP Model ARM-Z

MIM. Electromagnetic Flowmeter. Compact, All-metal Design

Through-beam ring sensors

Frame through-beam sensors

Insertion Thermocouples with Bayonet Lock

BGF. All-Metal Armored Variable Area Flowmeter and Totalizer. for Horizontal or Vertical Mounting

S 4. Vane Flow Meter, Monitor, Counter, Batching System. in modular design for liquids. Measuring accuracy: ± 2.5% f.s. : 100 bar; t max : 80 C.

DUC. Ultrasonic Flowmeter for Liquids. Portable or Stationary

PSD. Digital Pressure Sensor. LED Display with Switch & Analog Outputs

EXPERT-LINE. KOBO-pH. Transmitter for ph-value and ORP Model APM-X

The compact test- disconnect terminal interface system for protection and secondary technology

Specifications (in accordance with DIN 16086) Equipment family Digibar II Type 1-PE50A1/...; K-PE PE00A1/...; K-PE00... Class of accuracy 0.2 0

BGF. Full Metal Variable Area Flow Meter and Counter. for horizontal and vertical mounting. Special versions up to 600 bar

DMH. Magnetic Inductive Flowmeter. for Conductive Fluids

NBK-04. Level Indicator for Tank-Top Mounting

Electromagnetic flowmeters and switches DWM 1000/2000

DOG-4. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air. : PN 40; t max. p max : 120 C

Process Control HPP-25

ED701 General Industry Pressure Transmitter

Vane Flow Meter, Monitor, Counter, Batching System in Modular Design for Liquids

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

stripax The professional stripping tool

2-channel speed sensor GEL 247 Compact sensor for harsh applications

OVZ. Oval Wheel Flow Meter. for viscous liquids l/min liquid. Measuring accuracy: ± 2.5% f.s. p max : 40 bar; t max : 80 C

Who Reads and Who Follows? What analytics tell us about the audience of academic blogging Chris Prosser Politics in

Inclinometer Selection Guide

Page Type Resolution (mm) min. max. Output

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

MIM. Electromagnetic Flowmeter. Compact, All-metal Design

MEASUREMENT APPLICATION GUIDE OUTER/INNER

DUK COMPACT ULTRASONIC FLOWMETER

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Process-Controller HPP-25

Conductivity Transmitter N-LF V AC

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

ABB Oy, KPM. Sakeusmittaukset paperikoneen massanvalmistuksessa

Remote participation in Question sessions Audio options VoIP

Digital inductive conductivity transmitter

Catalogue NE 0506 FIXTURING SYSTEM. Modular Zero-Point Fixturing for Pallets, Workpieces and Fixtures

Regulatory status for using RFID in the UHF spectrum 3 May 2006

Technical Information Condumax CLS21D/CLS21

STAINLESS STEEL STAINLESS STEEL MANUFACTURING STAINLESS STEEL TRADING BRIGHT BARS WIRES PRECISION COMPONENTS

Table of Contents Executive Summary 29

Coriolis Massflowmeter

P R o D u c T I n F o R m at I o n. TDR Level Sensor LFP. The clean solution

Operating Instructions for Microwave Level Switch. Model: LNM

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

1204 Reflected Wave Reduction Device

Creating the world technology leader in surface solutions under one roof

TMU. Coriolis Mass Flow Meter. for liquids and gas

REMOTE SENSOR SERIES. Description

Digital conductivity transmitter

CISCO ONS /100-GHZ INTERLEAVER/DE-INTERLEAVER FOR THE CISCO ONS MULTISERVICE TRANSPORT PLATFORM

The transducer component converts the measured signal and displays the actual value.

Condumax W CLS15 and CLS15D

Coriolis Massflowmeter

Zero Point Clamping. Index O-MAK 4. Component parts and accessories 8. Page. Fresmak Introduction 2-3. Product 4. Applications 5.

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

Electronic Thermostat TE-1 Version according to EN

Technical Information Condumax CLS15D/CLS15

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Digital flow ELEMENT transmitter for continuous flow measurement

2018/2019 HCT Transition Period OFFICIAL COMPETITION RULES

Electromagnetic Flow Transmitter

Keysight Technologies N6850A Broadband Omnidirectional Antenna. Data Sheet

Temperature Sensor for Build-In System G3/8" FLEXadapt

Temperature Sensor for Build-In System G3/8" FLEXadapt

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Technical Data. General specifications. Rated operating distance s n 3 mm

Operating Instructions for Compact Vortex Flow Meter. Model: DVZ

Screw-in resistance thermometers with plug connector

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

SHORTFORM CATALOGUE. DIN EN Reg.-No. DAT-P-048/ Testing laboratory accredited according to

VITO LT. Global Experience. Locally Applied. A dependable choice.

Condumax CLS21 and CLS21D

Edition March 2011 With publication of this catalogue all former printed general catalogues about RECHNER sensors are invalid.

Transcription:

Electronic Flow Monitor for liquids measuring monitoring analysing KAL-K Range: approx. 4-200 cm/s p max : 100 bar Temperature of medium: -20... +80 C Option: 0... +120 C Process connection: G ¼, G ½, G ¾ M12x1, ¼" NPT, ½" NPT, ¾" NPT Tri-Clamp S5 Material sensor: 1.4305; 1.4301; 1.4404; 1.4571 Intelligent temperature compensation No moving parts Minimal pressure loss KOBOLD companies worldwide: ARGENTINA, AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLoMBIA, CZECHIA, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, Republic of Korea, ROMANIA, SINGAPORE, SPAIN, SWITZERLAND, TAIWAN, THAILAND, TUNISIA, turkey, USA, VIETNAM KOBOLD Messring GmbH Nordring 22-24 D-65719 Hofheim/Ts. Head Office: +49(0)6192 299-0 +49(0)6192 23398 info.de@kobold.com www.kobold.com 1

Electronic Flow Monitor Model KAL-K Method of operation The model KAL-... electronic flow monitor continuously monitors liquid media. It is suited for securely monitoring flows with minimum pressure loss. Sensitivity to soiling is significantly reduced by means of a single-part sensor. Theory of operation The operation of the model KAL-... electronic flow monitor is based on the calorimetric principle. The end face of the sensor is heated to a few degrees above the temperature of the flow medium. When the medium flows, the heat generated in the sensor is transferred to the medium, ie, the sensor is cooled. The cooling procedure is an accurate measure of the flow velocity. The sensor signal is compared with the reference data stored in a microcontroller. An alarm signal and/or an analogue signal (4-20 ma) that is proportional to the flow velocity is output if the actual flow velocity deviates from the desired flow velocity. The microcontroller allows the flow indicator to be easily calibrated and the temperature to be compensated. Temperature compensation The temperature of the KOBOLD flow monitor is compensated with a microcontroller. All data required for temperature compensation are stored in EEPROMS, and are maintained for at least 10 years after power failure. The instruments may be easily adjusted by the customer to suit process conditions. The measured flow rate is compared with the zero-point adjustment values stored in the EEPROM and the stored characteristic curves. The data is processed by the microcontroller and controls the alarm signal or the analogue output. The sensor switch point is absolutely consistent, as the sensor has been adapted to suit the process data. Drift of the switch point by temperature influence 2 ur Features Optimal temperature compensation Intelligent switching Measuring range adjustment No moving parts Easy to install and commission Minimal pressure loss Easy to use Switch Schaltpunkt point (m/s) KAL-... KAL-... with mit Kompensation compensation Standard without Herkömmlich compensation ohne Kompensation Measuring /switching ranges NW [mm] approx. measuring range l/min water NW [mm] approx. measuring range l/min water 8 0.12-6.0 40 3.0-150 10 0.19-9.4 50 4.7-235 15 0.42-21.8 60 6.8-340 20 0.75-37.7 80 12.0-603 25 1.18-59.0 100 18.8-942 30 1.7-84.8 150 42.4-2120 Important: The flow velocity has been converted for the nominal pipe size for the specified measuring ranges. Please note that the flow velocity approaches zero in the pipeline in the direction of the wall. Depending on the nominal pipe size, depth of engagement of the sensor, and flow profile, the deviations from the specified flow rates can be of considerable magnitude. 0 20 30 40 50 60 70 80 Temperatur (C) Temperature ( C) Range of models Compact devices KAL-A... Flow meter with analogue output (4-20 ma) KAL-AK Flow meter /-monitor with analogue output (4-20 ma) and alarm signal (PNP/NPN, N/O contact) KAL-K... Flow indicator alarm signal (PNP/NPN, N/O contact) Separate version KAL-... Sensor KAL-E1... Electronics with relay contact for flow monitoring KAL-E2... Electronics with relay contact and trend display for flow monitoring KAL-E3... Electronics with relay contact for flow and temperature monitoring trend display for flow monitoring 2 www.kobold.com

Electronic Flow Monitor - Compact Version Model KAL-K Technical Details (electronics) Case material: glass-fibre-reinforced polyamide Sensor material: Stainless steel (see order details) Power supply: 24 V DC ±10% 110 V DC ±30%, 110, 230-20/+10%, Power input: max. 4.5 W (typically 1,2 W) max. 3.6 W für 24 V DC Ambient temperature: -20 C... +60 C Medium temperature: -20 C... +80 C (standard version) 0 C... +120 C (high temp. version) CIP compatibility: max. 140 C non-operating Max. pressure: 100 bar Warm up time: max. 12 s Switching range: approx. 4 cm/s to 200 cm/s Temperature gradient: unlimited Response time: 5.6... 12 s typically on request: 2-5.6 s (KAL-KS...) Flow rate indication: trend display with 8-digit LED chain Switch point adjustm.: with potentiometer, optical indication on LED chain with flashing LED Output indicator: LED, red = alarm, green = flow OK Electr. connection: cable gland M16x1.5; connector M12x1 (only 24 V DC version) circular connector ⅞" with socket (230/115 V-versions) or connector M12x1 with socket and 2 m cable, 24 V DC version Switch output: 24 V DC version: semiconductor, PNP/NPN switchable, max. 400 ma, short-circuit proof 110 V DC version: relay max. 0,2 A /110 V DC 110, 230 version: relay max. 5 A N/O function: actual value setpoint value; (standard setting: green LED is energized) output switched N/C function: available as option Protection: IP 65 Order Details (Example: KAL-K1215 S PG 3) Material stainless steel / version Version Connection 1.4301 1.4305 1.4571 Standard Extended Standard Standard Extended Version version Version Version version G ¼ KAL-K1308 - - KAL-K1408 1) - G ½ KAL-K1315 KAL-K6315 KAL-K1215 KAL-K1415 KAL-K6415 G ¾ KAL-K1320 KAL-K6320 - KAL-K1420 1) KAL-K6420 1) Standard Version (-20...+80 C) Version for high temperature (0...+120 C) M 12x1 KAL-K0312 - - - - ¼" NPT KAL-K5308 KAL-K8308 - KAL-K5408 1) KAL-K8408 1) ½" NPT KAL-K5315 KAL-K8315 - KAL-K5415 KAL-K8415 ¾" NPT KAL-K5320 KAL-K8320 - KAL-K5420 1) KAL-K8420 1) Tri-Clamp, DIN 32676 - - - KAL-K4440 3) - G ¼ KAL-KH1308 KAL-KH6308 - KAL-KH1408 1) KAL-KH6408 1) G ½ KAL-KH1315 KAL-KH6315 KAL-KH1215 KAL-KH1415 KAL-KH6415 G ¾ KAL-KH1320 KAL-KH6320 - KAL-KH1420 1) KAL-KH6420 1) M 12x1 KAL-KH0312 - - - - ¼" NPT KAL-KH5308 KAL-KH8308 - KAL-KH5408 1) KAL-KH8408 1) ½" NPT KAL-KH5315 KAL-KH8315 - KAL-KH5415 KAL-KH8415 ¾" NPT KAL-KH5320 KAL-KH8320 - KAL-KH5420 1) KAL-KH8420 1) Tri-Clamp, DIN 32676 - - - KAL-KH4440 3) - 1) Stainless steel hexagon 1.4301 2) for 24 V DC only 3) Stainless steel 1.4404 Type of contact S = N/O contact Ö = N/C contact S = N/O contact Ö = N/C contact Electr. connection PG = Cable gland M16x1.5 M12x1 2) SK = Circular connector with socket PG = Cable gland M16x1.5 M12x1 2) SK = Circular connector with socket Power supply 0 = 230 1 = 110 3 = 24 V DC 6 = 110 V DC 0 = 230 1 = 110 3 = 24 V DC 6 = 110 V DC Please specify sensor length dimension C for extended version www.kobold.com 3

Electronic Flow Monitor - Separate Version Model KAL-E(H) Technical Details (sensor) Material: case: see order details cable: PVC option (KAL-...HT): silicone cable gland: brass nickel-plated, Pg 7 Cable: 2 x 0,56 mm 2, length = 2 m max. line length 100 m Switching range: 4 cm/s... 200 cm/s Temperature of medium: -20 C... +80 C, option (KAL-...HT): 0 C... +120 C Ambient temperature: -20 C... +80 C, KAL-...HT: 0 C... +120 C Max. Pressure: 100 bar (KAL-1132 and KAL-1140: 25bar) Protection: IP 68 Approval: ATEX: II 1G Ex ia IIB T4 Ga IECEx: Ex ia IIB T4 Ga Important! For cable lengths >10 m, the client can increase the absolute switching accuracy manually by adjustment (cable resistance must be considered). Electronics Model KAL-E(H).. Power input: max. 3.6 W Switch capacity: max. 250 V, max. 3 A Switch point adjustm.: with Potentiometer Switching function: changeover, on rising flow (terminals 9 +10 closed) Option (KAL-E3..): changeover, on rising temperature below setpoint, LED is energized (terminals 12 + 13 closed) Output: changeover relay Output indicator: with LED Warm up time: max. 12 s Temperature range: -20... +80 C Accuracy: temperature limit value ±2% Repeatability: approx. 2% Response time: 5... 12 s (typically) DIN rail fitting: DIN EN 50022 and DIN 46277 Protection: case: IP 40, terminals: IP 20 Case: polycarbonate, L75 x W 55 x H 110 mm Sensor output: short-circuit proof, cable break is detected as flow stoppage Power failure: calibration data are store without battery for 10 years Approval: ATEX: II (1)G [Ex ia Ga] IIB IECEx: [Ex ia Ga] IIB Order Details sensor (example: KAL-1308 HT) Connection Order numbers Electrical Sensor with insertion fitting Sensor with inline fitting connection/ version 1.4301 1.4571 Fitting brass/ Sensor 1.4301 4 www.kobold.com Fitting 1.4301/ Sensor 1.4301 G ¼ KAL-1308 KAL-1408 KAL-1108 KAL-1208 00 = 2 m PVC cable G ⅜ - - KAL-1110 KAL-1210 HT = 2 m Silicone cable G ½ KAL-1315 KAL-1415 KAL-1115 KAL-1215 YP = PVC cable/ G ¾ KAL-1320 KAL-1420 KAL-1120 KAL-1220 special length G 1 - - KAL-1125 KAL-1225 YS = Silicone cable/ G 1 ¼ - - KAL-1132 KAL-1232 special length G 1 ½ - - KAL-1140 KAL-1240 YY = Special cable/ M 12 x 1 KAL-0312 - - - special length ¼" NPT KAL-5308 KAL-5408 KAL-5108 KAL-5208 Ex = Ex sensor, ⅜" NPT - - KAL-5110 KAL-5210 PVC cable ½" NPT KAL-5315 KAL-5415 KAL-5115 KAL-5215 Ex ia IIB T4 Ga ¾" NPT KAL-5320 KAL-5420 KAL-5120 KAL-5220 (specify cable length) Order Details electronics (example: KAL-E10 (standard) or KAL-EH10 (version for high temperature) Field of Flow trend Temperature Supply voltage application display monitoring 24 V DC 24 110 230 Flow - - KAL-E13 KAL-E12 KAL-E11 KAL-E10 KAL-EH13 KAL-EH12 KAL-EH11 KAL-EH10 Flow 8-LEDs - KAL-E23 KAL-E22 KAL-E21 KAL-E20 KAL-EH23 KAL-EH22 KAL-EH21 KAL-EH20 [Ex ia Ga] IIB Flow/ Temperature Flow/ Temperature 8-LEDs -20... +80 C KAL-E33 KAL-E32 KAL-E31 KAL-E30 0... +120 C KAL-EH33 KAL-EH32 KAL-EH31 KAL-EH30 8-LEDs -20... +80 C - KAL-E32Ex - KAL-E30Ex

Flow Meter/Monitor Compact Version Model KAL-A(K) Technical Details Case material: glass-fibre-reinforced polyamide Sensor material: stainless steel (see order details) Power supply: 24 V DC ±20% Power input: max. 3,6 W (typically 1,2 W) Ambient temperature: -20 C... +60 C Temperature of medium: -20 C... +80 C Max. Pressure: 100 bar Warm up time: max.12 s Measuring range: approx. 4 cm/s to 200 cm/s Temperature gradient: unlimted Response time: 5.6... 12 s Accuracy: ±10% of full scale Repeatability: ±1% of full scale Signal output: 4-20 ma Flow rate indication: trend display with 8-digit LED chain Protection: IP 65 Electrical connection For KAL-AK... only Switching function: N/O contact Switch point adjustment: with potentiometer, optical indication on LED chain with flashing LED Output indicator: LED, red = alarm, green = flow OK Switching output: semiconductor, PNP/NPN switchable, max. 400 ma, short-circuit proof 4 3 2 1 KAL-A... 4...20 ma +24 V DC Ground KAL-AK... 4 4...20 ma 3 +24 V DC 2 Ground 1 PNP/NPN-Switch Order Details (example: KAL-A1308A4 PG) Output/ contact 4-20 ma/ without contact 4-20 ma/ N/O contact NPN/PNP switchable Order numbers for materials Connection 1.4301 1.4305 1.4404 G ¼ KAL-A1308A4 - KAL-A1408A4 1) G ½ KAL-A1315A4 KAL-A1215A4 KAL-A1415A4 G ¾ KAL-A1320A4 - KAL-A1420A4 1) M 12 x 1 KAL-A0312A4 - - ¼" NPT KAL-A5308A4 - KAL-A5408A4 1) ½" NPT KAL-A5315A4 - KAL-A5415A4 ¾" NPT KAL-A5320A4 - KAL-A5420A4 1) Tri-Clamp, DIN 32676 - - KAL-A4440A4 2) G ¼ KAL-AK1308AS - KAL-AK1408AS 1) G ½ KAL-AK1315AS KAL-AK1215AS KAL-AK1415AS G ¾ KAL-AK1320AS - KAL-AK1420AS 1) M 12 x 1 KAL-AK0312AS - - ¼" NPT KAL-AK5308AS - KAL-AK5408AS 1) ½" NPT KAL-AK5315AS - KAL-AK5415AS ¾" NPT KAL-AK5320AS - KAL-AK5420AS 1) Tri-Clamp, DIN 32676 - - KAL-AK4440AS 2) Electr. connection PG = cable gland M16x1,5 M12x1 PG = cable gland M16x1,5 M12x1 1) Stainless steel hexagon 1.4301 2) Stainless steel 1.4404 www.kobold.com 5

BC Electronic Flow Meter/Monitor Model KAL-K Dimensions KAL-K.., KAL-A(K)... C 13 approx. ca. 97 97 A C [mm] E [mm] F [mm] G [mm] G ¼ 26 7 - - G G ½ 40 9 - - G ¾ 43 12 - - M12 x 1 23 6 - - ¼" NPT - 6 10 26 A E NPT F 41 SW AF 41 approx. ca. 110 110 ½" NPT - 18.5 15 43 ¾" NPT - 18 15 39 G 10 approx. ca. 94 97 KAL-... Sensor A B C [mm] D [mm] M12 x 1 19 AF 23 43 G ¼ 19 AF 26 43 G ½ 27 AF 43 58 G ¾ 32 AF 43 58 D A L=2000 20 KAL-... with pipe fitting 60 +10 A B C [mm] D [mm] E [mm] G ¼ 27 AF 10 50 81 G ⅜ 27 AF 10 50 81 E G ½ 27 AF 10 50 81 G ¾ 32 AF 15 52 82.5 30 SW AF30 G 1 39 AF 15 56 85 G 1 ¼ 46 AF 15 50 90 A B G 1 ½ 55 AF 15 50 92.5 C D C approx. ca. 110 110 KAL-..4440 with Tri-Clamp Counterpart according to DIN 32676 for NW 32/NW40 Ø 70 81 approx. ca. 165 165 42 Ø 50,4 6 www.kobold.com