VFB40 Frequency inverters 004 to 016 (B1) VFX40 Frequency inverters 018 to 037 (S2)

Similar documents
FDU50 Frequency inverters 018 to 037 (S2) FDU50 Frequency inverters 046 to 060 (X2)

Emotron FDU 2.0 Variable Speed Drive

Emotron FDU 2.0 Variable Speed Drive

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters.

SX (400V) System configuration

SX (400 V) System configuration

SX (690 V) System configuration

Dynamic drives for low power AC motors

TECHNICAL CATALOGUE EMOTRON FLOWDRIVE EMOTRON FLOWDRIVE KW, V IP20, IP21 AND IP54

Version number A=standard P=Cold Plate (Frame A only) T=Brake chopper (Frame A only) Input voltage 11=115VAC 21=230VAC 1φ 23=230VAC 3φ 43=400VAC

Emotron VFX 2.0 Variable Speed Drive

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

FLOWDRIVE FDU. Valid for the following inverter Models: FDU to FDU40-1k1 FDU to FDU50-1k1 FDU to FDU69-1k1 Software version: 3.

ACS600, ACS800. Installation Guide

Absolute maximun ratings. 50 Hz SEMIKUBE - Size T0.5

vacon nxs robust drive for heavy use

Siemens AG Allows easy and consistent configuration with one series of overload relays (for small to large loads)

Absolute maximun ratings. 50 Hz SEMIKUBE - Size T2H. Three phase inverter VBUS Rated DC voltage 750 VDC Efficiency W η Inverter efficiency

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

MAGTROL. LMU Series Load Monitoring Units. LMU Data Sheet. Description. Features

SKS SL 80 GD 50/10 - E4 P1

Why choose Danfoss? VLT Technical data Dimensions Ordering

ACH550 HVAC Drive Submittal

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

This Chapter contains:

6PS04512E43W TechnicalInformation. Preliminarydata. Generalinformation. PrimeSTACK

58 SERIES. Relay interface modules 7-10 A 58.P3 58.P4

VF-nC1 Adjustable Speed Drive Engineering Specification

MAGTROL. LMU 116 Load Monitoring Unit. LMU 116 Data Sheet FEATURES DESCRIPTION SYSTEM CONFIGURATION

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

Emotron VFX size C Variable Speed Drive

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

S11 Adjustable Speed Drive Engineering Specification

EC centrifugal fan - RadiCal

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

6MS30017E43W Technical Information. Preliminary data. General information ~ ~ ~ ModSTACK HD

TECO V33 Variable Speed Drive

Subject to changes 11/2003 Page 1/7

ATS01N222LU soft starter for asynchronous motor - ATS01-22 A V KW

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

SKS SL 150 GD 50/10 - E4 P1

MAGTROL. LMU 112 and LMU 117 Load Monitoring Units. LMU 112 / LMU 117 Data Sheet LMU 112 FEATURES LMU 117 FEATURES DESCRIPTION SYSTEM CONFIGURATION

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

LXM32CD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

B850 Boiler House Energy Monitor

SKS B2 120 GD 69/11 - MA PB

Orbital GFI Inverter Series

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

Multi-voltage Multi-function. Wiring diagram (without control signal)

Altivar 28 drive Altivar 28 enclosed drive

Preset counters, electronic

Inverter MICROMASTER 410

The rated power delivered by the motor (nameplate data) Power losses at idle state R Fe. Main Reactance

38 Series - Relay interface modules A. Features /

For non-electrical quantities

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

SKS C 120 GDD 69/11 A3A MA B1C

6MS30017E43W TechnicalInformation. Preliminarydata. Generalinformation. ModSTACK HD

Integrated servo motor

Digital flow transmitter for continuous flow measurement

ZITARES NCS 2 nd Generation Non-SELV, Constant current control gear, 1-channel, non-dimmable

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

Emotron FDU and VFX AC drives

SKS B2 120 GDD 69/11 - A11 MA PB

PHOENIX CONTACT - 09/2009

IB IL AO 1/U/SF. Function. INTERBUS Inline Terminal With One Analog Voltage Output. Data Sheet 5736CC01

POWERBOX Defense Line 1200 DBA Series 1200W AC/DC Conduction Cooled. Preliminary

48 Series - Relay interface modules A. Features

EC centrifugal fan. forward curved, dual inlet with housing (flange)

MICRO-ISO AUTOMOTIVE RELAY

B850 Boiler House Energy Monitor

SKS C 240 GDD 69/11 A6A MA B1C

EN 50178, IEC

Output of three-phase motors at 50 Hz and 400 V

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES

maxon document number:

User's Guide for type ACS55 AC Drives from 0.18 to 2.2 kw

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12

MODULAR DC POWER SUPPLIES & SYSTEMS. DC Power Systems DC/AC Inverters Static Switches DC/DC Converters. GAMATRONIC, A SolarEdge Division

Manual Overview...1 2

Temposonics. R-Series SSI. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Stroke length mm. Perfect data processing 0.

ADJUSTABLE SPEED DRIVES. AS1 Drive

KNC-SRV-FD423 Series Servo Driver

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

Thermistor motor protection relays

PHASED OUT. LED Driver Compact fixed output. Driver LCI 10W 150mA 400mA TOP C TOP series. Product description

Pulse Scaler for DIN Rail Attachment

Rexroth Frequency Converter Fe 0.75 kw to 7.5 kw / 400 VAC

ILA2E572PC1A0 integrated drive ILA with servo motor V - EtherCAT - indus connector

ISOMETER IRDH575. Approvals

D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

HITEK POWER XR KW X-RAY POWER SUPPLY MODULE

Datasheet. Modular Inverter System VARIS Datasheet VARIS

Transcription:

Data sheet VFB/VFX40 VFB40 Frequency inverters 004 to 016 (B1) Type number VFB40-004 -006-008 -010-012 -016 Rated power kw 1.5 2.2 3 4 5.5 7.5 Rated output current A,RMS 4 6 7.5 9.5 12 16 Current limit ICL, 120s A,RMS 6 9 11.3 14.3 18 24 Peak motor current A,peak 10.7 16.1 20.2 25.5 32.2 42.9 Input current A,RMS 4.5 6.8 8.5 10.5 13.3 17.8 Mains fuse gl/gg acc. to IEC269 A 6 10 16 20 Ambient temperature for rated power C 0-40 Switching frequency fs khz 3.0 khz Efficiency (Pnom) % 97 Losses (Pnom) W 45 66 90 120 165 225 Derating %/ C No derating required Dimensions HxWxD mm 360x126x260 Weight kg 7 Glands mains/motor cable None (clamps used) Max. section motor/mains cable solid (stranded) mm 2 4 (2.5) 10 (6) VFX40 Frequency inverters 018 to 037 (S2) Type number VFX40-018 -026-031 -037 Rated power kw 7.5 11 15 18.5 Rated output current A,RMS 18 26 31 37 Current limit ICL, 60s A,RMS 27 39 46 55 Input current A,RMS 16 23 28 35 Min. brake resistor (for option brake chopper) Ω 22 22 22 22 Mains fuse gl/gg acc. to IEC269 A 20 25 35 50 Ambient temperature for rated power C 0-40 Switching frequency fs khz 3.0 khz Efficiency (Pnom) % 98 Losses (Pnom) W 235 325 385 460 Derating %/ C -2.5 to +10 C max Dimensions size X2 HxWxD mm 470(530) x 176 x 272 Weight kg 19 Mains/motor cable entry mm Ø32 Max. section motor/mains cable solid (stranded) mm 2 16(10) 1

VFX40 Frequency inverters 046 to 073 (X2) Type number VFX40-046 -060-073 Rated power kw 22 30 37 Rated output current A,RMS 46 61 74 Current limit ICL, 60s A,RMS 69 92 111 Peak motor current A,peak 133 177 215 Input current A,RMS 42 57 70 Mains fuse gl/gg acc. to IEC269 A 50 63 80 Ambient temperature for rated power C : 0-40 : 0-35 Switching frequency fs khz 3.0 khz Efficiency (Pnom) % 97.5 Losses (Pnom) W 550 750 925 Derating %/ C -2.5 to +10 C max Dimensions HxWxD mm 530(590)x220x270 Weight kg 30 Glands mains/motor cable Max. section motor/mains cable solid (stranded) mm 2 16 (10) 25 (16) 50 (35) M40 VFX40 Frequency inverters 074 to 090 (X3) Type number VFX40-074 -090 Rated power kw 37 45 Rated output current A,RMS 74 90 Current limit ICL, 60s A,RMS 111 135 Peak motor current A,peak 215 261 Input current A,RMS 69 85 Mains fuse gl/gg acc. to IEC269 A 80 100 Switching frequency fs khz 3.0 khz Ambient temperature for rated power C : 0-40 : 0-35 Efficiency (Pnom) % 97.5 Losses (Pnom) W 925 1125 Derating %/ C -2.5 to +10 C max Dimensions HxWxD mm 650(750)x340x295 Weight kg 55 Glands mains/motor cable M50 Max. section motor/mains cable solid (stranded) mm 2 50 (35) 2

VFX40 Frequency inverters 109 to 175 (X4) Type number VFX40-109 -146-175 Rated power kw 55 75 90 Rated output current A,RMS 109 146 175 Current limit ICL, 60s A,RMS 164 219 263 Peak motor current A,peak 316 423 508 Input current A,RMS 104 139 166 Mains fuse gl/gg acc. to IEC269 A 125 160 200 Ambient temperature for rated power C : 0-50 : 0-45 : 0-40 : 0-35 Switching frequency fs khz 3.0 khz Efficiency (Pnom) % 97.5 Losses (Pnom) kw 1.4 1.9 2.3 Derating %/ C No derating required -2.5 to +10 C max Dimensions HxWxD mm 800(900)x450x330 Weight kg 85 Glands mains/motor cable Max. section motor/mains cable solid (stranded) mm 2 50 (50) 95 (95) M63 VFX40 Frequency inverters 210 to 374 (X5) Standard without output coils and with Control Panel. Type number VFX40-210 -250-300 -374 Rated power kw 110 132 160 250 Rated output current A,RMS 210 250 300 375 Current limit ICL, 60s A,RMS 315 375 450 560 Peak motor current A,peak 609 725 870 1080 Input current A,RMS 200 238 285 356 Mains fuse gl/gg acc. to IEC269 A 200 250 315 500 Switching frequency fs khz 1.5kHz Ambient temperature for rated power C : 0-50 : 0-45 : 0-40 : 0-35 Efficiency (Pnom) % 97.5 Losses (Pnom) kw 2.8 3.3 4 6.2 Derating %/ C No derating required -2.5 to +10 C max Dimensions HxWxD 1100(1145)x500x420 mm 2150x600x500 Weight () kg 160 (275) Terminals mains/motor connections mm 2 150 240 3

VFX40 Frequency inverters 500 to 749 (X10) Type number VFX40-500 -600-749 Rated power kw 250 315 400 Rated output current A,RMS 500 600 750 Current limit ICL, 60s A,RMS 750 900 1125 Peak motor current A,peak 1450 1740 2175 Input current A,RMS 475 570 721 Mains fuse gl/gg acc. to IEC269 A 2x250 2x315 2x400 Switching frequency fs khz 1.5kHz Ambient temperature for rated power C : 0-40 : 0-35 Relative humidity % 0-90 (non condensing) Efficiency (Pnom) % 97.5 Losses (Pnom) kw 6.3 7.9 10 Derating %/ C -2.5 to +10 C max Dimensions HxWxD 2x 1100(1145)x500x420 mm 2150x1200x500 Weight (IP23/) kg 320 (525) Terminals mains/motor connections mm 2 2x150 2x240 2x240 4

Common data VFB/VFX40 Mains voltage V 400-415 +10% /-15% Mains frequency Hz 50/60 Output frequency range Hz 0-300 Output voltage range V 0 - Mains Maximum sound pressure level db(a) 70 Relative humidity % 0-90 (non condensing) Atmospheric pressure kpa 86-106 Vibrations EN60068-2-6 Fc: 10-150Hz; 0.075mm/1g Cooling Forced, automatic Power factor input current 0,95 Glands control signal cables ( or EMC-kit only, with grommets) 2x M20 Max. control signal cable section solid (stranded) mm 2 2.5 (1.5) Digital inputs Analogue inputs (differential) Digital outputs Analogue outputs 8x 2x 2x 2x Input voltage HIGH: Input voltage LOW: Max. input voltage: Input resistance: Signal delay: Input voltage/current: Max. input voltage: Input impedance: Resolution: Hardware accuracy: Non-linearity: Output voltage HIGH: Open voltage HIGH: Output voltage LOW:.Short-circuit current: Output voltage/current: Max. output voltage: Short-circuit current ( ): Output impedance: Resolution: Hardware accuracy: >7VDC <4VDC 30VDC <14VDC: 5kΩ 14VDC: 3kΩ 8ms ±10V/±20mA via jumper ±30V 21kΩ (voltage) 250Ω (current) 10 bits 0.5% typ + 1½LSB fsd 1½LSB >20VDC @50mA >23VDC <1VDC @50mA 100mA max * ±10V/+20mA via jumper ±15V @5mA cont. ±15mA (voltage) 140mA (current) 10Ω (voltage) AnOut 1: 10 bits AnOut 2: 8 bits 1.9% typ fsd (voltage) 2.4% typ fsd (current) 3LSB 2LSB Full scale and zero error: Non-linearity: Relays 2x Change-over contact 2A max. Signal ground 3x Signal supply voltage 10VDC 1x Current: 10mA max @10VDC Short-circuit current: 30mA Signal supply voltage 10VDC 1x Current: -10mA max @-10VDC Short-circuit current: -30mA Signal supply voltage 24VDC 1x Current *: 100mA short-circuit proof Trip memory Storage of last 10 trips. Resetable Acceleration/Deceleration times s 0.01-3600s together 5

Standards The VFB/VFX complies with the standards EN61800-3, EN50178, EN60204-1 and EN60529. It is adapted to the Machine Directive and complies with the EMC-Directive and the Low Voltage Directive, which is indicated by the CE-mark and accompanying declarations. 6

Dimensions VFB40-004 to -016 (B1) Dimensions VFX40-018 to -037 (S2) 128,5 126 30 10 360 260 Dimensions VFX40-046 to -073 (X2) Dimensions VFX40-074 to -090 (X3) 220 160 570 590 30 470 510 176 10 272 7(4x) 270 295 7

Dimensions VFX40-109 to -175 (X4) Dimensions VFX40-210 to -374 (X5) 330 420 Dimensions VFX40-500 to -749 (X10) Cabinet options Output coils (with single motor terminals). Mains switch. Mains contactor. Emergency switch. 8

Type number code VFX 40-031 -20 CEB C = Control Panel E = EMC kit B = Brake chopper 20 = 54 = 031 = Rated current 400 = Mains 400-415V +10% /-15% VFB VFX Power connections OPTION L1 L2 L3 PE DC DC -- + R U V W (VFB /S2) S4 S3 S2 S1 Signal connections S5 S6 Connections terminal strip 1-22 Nr Name Type Function Signal 1 +10V Ref +10VDC Reference voltage, 10mA max. 2 AnIn1+ Ana.Input Differential input Programmable 3 AnIn1- Ana.Input ±10VDC or 0/4-20mA Resolution 10bits 4 AnIn2+ Ana.Input Differential input Programmable 5 AnIn2- Ana.Input ±10VDC or 0/4-20mA Resolution 10bits 6-10V Ref -10VDC Reference voltage, 10mA max. 7 Common Signal ground 8 Run L Binary Input Run Left Level high 0-8/24VDC or 0-20mA 9 Run R Binary Input Run Right Level high 0-8/24VDC or 0-20mA 10 Enable Binary Input Enable Level high 0-8/24VDC or 0-20mA 11 +24V Ref 24VDC Regulated, 100mA max (together with DigOut 1&2). 12 Common Signal ground 13 AnOut1 Ana.Output Programmable ±10VDC or 0/4-20mA Resolution 10bits 14 AnOut2 Ana.Output Programmable ±10VDC or 0/4-20mA Resolution 8bits 15 Common Signal ground 16 DigIn1 Binary Input Programmable Active high 0-8/24VDC or 0-20mA 17 DigIn2 Binary Input Programmable Active high 0-8/24VDC or 0-20mA 18 DigIn3 Binary Input Programmable Active high 0-8/24VDC or 0-20mA 19 DigIn4 Binary Input Programmable Active high 0-8/24VDC or 0-20mA 20 DigOut1 Binary Output Programmable 24VDC (See pin 11: +24VDC) 21 DigOut2 Binary Output Programmable 24VDC (See pin 11: +24VDC) 22 Reset Binary Input Reset Level high 0-8/24VDC or 0-20mA (06-F31A_2) Connections terminal strip 31-33 31 Rel.1 NC Change-over contact Relay 1: 32 Rel.1 P Relay output Isolated Programmable 33 Rel.1 NO 2A/250V /AC1 Connections terminal strip 41-43 41 Rel.2 NC Change-over contact Relay 2: 42 Rel.2 P Relay output Isolated Programmable 43 Rel.2 NO 2A/250V /AC1 9

www.emotron.com 01-1888-01r6, 801043 03 10