Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN

Similar documents
Transducer transmitter BILT 4 II 2(1) G. Technical Manual

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

INSTRUCTION MANUAL (ATEX / IECEx)

Differential pressure sensors

SALES SERVICE +358 (0)

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

ED701 General Industry Pressure Transmitter

Submersible pressure sensor For water and wastewater Model LW-1

Submersible pressure sensor For oils and fuels Model LF-1

Positioner with HART Communication Type 3780

Manostar Electronic Low Differential Pressure Measurement System

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

KFS. Flap-type flow meter. Design and range of application

Design and applications

Series P. Applications

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

Isolators A3/1.

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Operating Instructions

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

Temperature Input Module for Zone 1 Series 9482/32

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Target disk flowmeter for liquids and gases

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

Any installation position possible. 1K5, but C. < 2 % of the control range. < 0,2 % / 0,1 bar, type 824.P < 0,1 % / 0,1 bar. Approx.

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Operating Manual * * Differential pressure transmitter. Table of Contents. 1 Safety guidelines. 1.1 General Information

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Pressure Transmitter SIL

Page Type Resolution (mm) min. max. Output

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

electronics Data Sheet Industrial Amplifier Special features Dimensions (in mm; 1 mm= inches) B en

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the Soliwave M microwave barrier

Specifications (in accordance with DIN 16086) Equipment family Digibar II Type 1-PE50A1/...; K-PE PE00A1/...; K-PE00... Class of accuracy 0.2 0

Metal tube variable area flowmeters for gases, liquids and steam

Level and Pressure. Product Information. Vibrating level switches

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Wind Transmitter First Class

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Submersible pressure sensor For superior applications Model LF-1

T11 - T12 - T13. Electrical contacts stainless steel thermometers. Specifications (20 C) Ø Ø Ø 160 mm

Digital flow transmitter for continuous flow measurement

MINI MCR-SL-UI-I-LP-NC

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

Resistance Thermometers Model Series TR7X0, Sheathed Design

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

SATRON VB Pressure Transmitter

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

Transmitter for temperature and direct current variables in four-wire circuit. Contrans T TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex 11-3.

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

DPS 100 DPS 100. Gauge- / Differential- / Absolute Pressure Transmitter

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

Analog Universal Module HART for Zone 2 Series 9468/33

Power supply. Calibration. Surface finishing. Seal. Process connection

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

Weighing Instruments

Digital Input Output Module for Zone 2 Series 9470/33

Rotary Measurement Technology Incremental Encoders

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Proportional Directional Control Valves Size 6

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

The transducer component converts the measured signal and displays the actual value.

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Electrodynamic Velocity Sensor

Actuators for modulating control AME 85, AME 86

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

Weighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier

2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS

Process display RIA 261

INSTALLATION AND OPERATION MANUAL

IP26 Series Current to Pneumatic Converter

Installation and Operating Manual

Isolators A3/1. Vibration Transducer Supply Unit Series

SET Installation and Operating Instructions. Level switch for two sensors

Dissolved Oxygen Transmitter

Euromas Polymas. Colour: Silver grey, similar to RAL 7001; special colours on request

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

CEAG Products Main Catalogue Part 2: Chapter Ex-Control units and control stations. EATON 2.4.1

Capacitive Proximity Sensor

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

For use in Flammable Gas and Dust Atmospheres

Transcription:

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas Mimablad: 176GB/1999-10-25 Ersätter: MG-1000-EEx USAGE MG-1000-EEx is suitable for use in measurement and control circuits in air treatment processes where explosive gases can exist temporarily or permanently. The design permits use in risk areas classified Zone 0, 1 and 2 when the ignition temperature for the explosive gas exceeds 135 ºC. STRUCTURE AND DESIGN MG-1000-EEx consists of two parts: the pressure transmitter MG-1000-T-EEx and the MG-1000-M-EEx. Pressure transmitter The pressure transmitter is placed in the most appropriate position from a measurement and service point of view in the potentially explosive area. The measurement system is enclosed in a die-cast light metal housing and consists of an equalizer spring system in which a rubber membrane is suspended. The position of the membrane is sensed by an IR optical measurement system, after which the signal is amplified. The pressure transmitter is supplied in a steel enclosure with protection class IP66. Safe Säkertarea område Matningsdon Transmitter Givare p Potentially Explosionsfarligt explosive område area The is installed in the safe area. It contains a voltage supply unit, measurement value converter, indicator and output signal amplifier. The indicator is fitted on a special card and also includes the possibility of square root linearization for the flow indication and flow linear output signal. The indication of the flow and velocity can be adjusted to the requisite using a strap and potentiometer. The decimal point can be placed in the desired position by strapping. The has protection class IP44 and is equipped with a bracket for DIN rail EN50022. A transparent plastic cover protects the front panel and indicator. Electrical connections and setting of the desired output signal and made by removing the unit s left-hand end plate. Behind the right-hand end plate is a terminal block for the intrinsically safe circuits and the setting of flow indication. Safety The pressure transmitter and are designed according to the European standard EN 50014 and EN 50020 for intrinsic safety, explosion group and temperature class: * EEx ia IIC T4 for the pressure transmitter * [EEx ia] IIC for the.

Installation Pressure transmitter 1. Remove the cover from the enclosure. 2. Install the enclosure vertically on, e.g. a wall in the potentially explosive area. This is so the pressure measurement will be correct. 3. The capacitance of the cable between the pressure transmitter and the must NOT exceed 38 nf (also see TECHNICAL DATA). 4. Strip the cable s outer sheath so that the conductors are approx. 10 cm long. Now insert the cable through the cable gland. 5. Fold down the conductors in the centre of each terminal and cut, strip and connect. 6. Ensure the conductors are not strained and then tighten the cable gland. 7. Connect the enclosure to earth. 1. Fit the DIN rail in an appropriate position. Make sure there is sufficient space to remove the end plates with a screwdriver. 2. Remove both end plates and push the Supply unit onto the rail. 3. Pull out the base plate and fit the cable glands. The holes not used should be plugged again. 4. Strip the outer sheath on supply cable and the transmitter cable so that the conductors are approx. 20 cm long. Strip the outer sheath on the output signal cable so that the conductors are approx. 15 cm long. 5. Insert the cables in the cable glands and tighten. Fold down the conductors 90º towards the base plate. Slide in the base plate in the slot and fold up the conductors towards the terminal block. 6. Fold down the conductors in the centre of each terminal and cut, strip and connect. The enclosure is earthed by clamping the earth conductor between the nut strips below the terminal on the left-hand side. Also refer to the Swedish electro technical standard SS 421 08 21 with regard to the installation. PRESSURE CONNECTION The pressure connection to the pressure transmitter should be made using Micatrone s impulse line kit to obtain secure and sealed operation. (Data sheet MDS-1249/94). The measurement outlet is connected via an 8/6 mm pneumatic HT plastic tube. * Positive pressure is connected to the + outlet. * Negative pressure is connected to the outlet. When measuring the differential pressure the highest absolute pressure is connected to the + outlet. NOTE! Outlets not used are left open to the atmosphere.

SETTING THE OUTPUT SIGNAL Setting the output signal s zero point 1. Remove the left-hand end plate on the Supply unit. 2. Setting takes place using the no. 1 and no. 2 dipswitches below the terminal block. No. 1 ON and no. 2 OFF gives 0 20 ma / 0 10 V No. 1 OFF and no. 2 ON gives 4 20 ma / 2 10 V OUTPUT SIGNAL OUTPUT SIGNAL The is equipped with automatic switching between current and voltage output signals. With loads less than 400 Ω a current output signal is given and with loads greater than 600 Ω a voltage output signal is given. However, due to the s inner resistance the load should exceed 5k Ω with a voltage output signal. Avoid loading the output signal more than 400 Ω if a current output signal is required. The can be blocked so that only the current output signal is obtained. This takes place by setting the dipswitch no. 3 in the OFF position. ZERO POINT CALIBRATION 1. Before zero point calibration can take place the must be voltage fed and the end plates screwed on for at least 60 minutes to reach its working temperature. 2. The output signal from the is measured using an accurate digital volt/ma meter. 3. Set the block valve to the calibration position. If there is no block valve remove the pressure hoses from the pressure transmitter. 4. Adjust the zero point using the trimming potentiometer on the front of the pressure transmitter. Check that the s digital indicator shows zero in the pressure indication position (switch on the front in the left-hand position). 5. Reset the block valve (refit the hoses). MAINTENANCE Normally the MG-1000-EEx requires no service, but we recommend that the zero point should be checked annually. Pressure linear output signal Auto. switching Only No 4 and no 5 dipswitches are used internally by the and should be in the OFF position. Switching the output signal s function 1. Remove the right-hand end plate. 2. Switching takes place with SW1 pos 5&6on the s upper card. Pos. 5 strapped gives pressure linear output signal Flow linear output signal % of the pressure Pos. 6 strapped gives flow linear output signal % of the pressure

SETTING THE FLOW INDICATION The flow indication is set according to the selected measurement element/measurement method. The indicator s decimal point is selected using SW1 (placed on the upper card s right-hand side in the ) pos. 1&2andthe using pos. 3 & 4. The flow indication is finely trimmed using potentiometer P4. To adjust: remove the enclosure s right-hand end plate and set the straps as shown below. Placement of the decimal point No decimal point 000 The strap placed across pos. 1 & 2. Decimal point after the first digit 0.00 The strap in pos. 2. Decimal point after the second digit 00.0 The strap in pos. 1. Adjusting the indication using potentiometer P4 The adjustment s for P4 stated below apply when the flow linear output signal is 50% (25% differential pressure). Also refer to the diagram on the next page that shows the indicator s value as a function of the flow linear output signal at the 4 different s. Adjustment 0...300 BN Strap across pos. 3 & 4 on the lowest row closest to the circuit card Adjustment 300...570 B3" Pos. 3 strapped. Adjustment 570...810 B4" Pos. 4 strapped. Adjustment 810...999 BU Strap across pos. 3 & 4 on the upper row. Connect pressure to the pressure transmitter and read off the pressure on the s indicator with the switch on the front in the left-hand position ( p). Now turn the switch to the right (V) and adjust the value using P4 on the right-hand side of the upper card according to the value read off from the measurement station s diagram or the calculated value. Formula for calculating the velocity and flow. v=k m p m/s V=A K pm 3 /s m v = velocity in m/s K m = measurement probe s flow constant p = differential pressure in Pa V = flow in m 3 /s A = duct area in m 2 Principle diagram of the s upper card Digital indicator Test outlet during manufacturing and servicing SW1 Pin strip for strapping Switch for the indicator Right position flow Left position pressure P4 Potentiometer to adjust the flow indication

Display 999 800 BU B4 600 B3 400 200 BN 10 20 30 40 Flödesutsignal (%) Flow linear output signal (%) Example: When the flow linear output signal is 65% (6.5 Volt with output signal 0-10 Volt) the indicator shall show 44.0 m 3 /h. The strap shall then be placed in position 3 ( B3 ). 50 60 70 80 90 100 TECHNICAL DATA, PRESSURE TRANSMITTER Supply voltage: 20 VDC (max 23,0 VDC) Protection class: IP66 Highest power that may be applied: P i = 0,64 W Enclosure material: Powder coated sheet steel Highest current that may be applied: Internal inductance: Internal capacitance: Output signal: I i = 111 ma L i = Negligible C i = 137 nf 4...20 ma, R Lmax = 500 Ω Colour: Electrical connection: Pressure connection: Dimensions: RAL 7032 (Beige) 1 pc. PR 15.2 8/6 mm pneumatic hose B x HxD= 175x130x75mm Ambient temperature: : standard : special Overload: Underload: 0...40 C 0...100 Pa 0...200 Pa 0...500 Pa 0...1 kpa 0...2 kpa 0...5 kpa Contact Micatrone for information regarding available measuring s(i.e -50...+50 Pa) Max 50 kpa Max 10 kpa Weight: 1.6 kg accuracy according to IEC 770 < ± 0.8 % of the measurement error: Hysteresis: Repeatability: Temperature operation: < ±1%ofthemeasurement < 0.2 % of the measurement < 0.05 % / C

-6- TECHNICAL DATA, SUPPLY UNIT Supply voltage: Power consumption: Output signal: pressure linear or flow linear (Electric isolation from supply voltage) Indication: Scales: Ambient temperature: Protection class: 230 ± 20 VAC 50/60 Hz Max 8 VA at 230 VAC 0...20 ma, R Lmax = 400 Ω 4...20 ma, R Lmax = 400 Ω 0...10 Volt, R i =28Ω 2...10 Volt, R i =28Ω Pressure, flow or velocity with 3 digits Pa, kpa, m/s, m 3 /s, m 3 /h or l/s 0...40 C IP44 Accuracy according to IEC 770 The measuring accuracy for the pressure transmitter (MG-1000-T-EEx) is included in the following values: error: Pressure linear output signal error: Flow linear output signal Hysteresis: Repeatability: Temperature operation: <±1%ofthemeasurement < ± 10 % of the measurement at 0...10 % p <±3%ofthemeasurement at 10...100 % p < ±1%ofthemeasurement < 0.2 % of the measurement < 0.05 % / C Material enclosure: Electrical connection: Dimensions: Aluminium/Plastic 6 PCS. PR 22,5 B xhxd= 234x141x95mm WIRING DIAGRAM Matningsdon Left-hand Vänster sidesida Protective Skyddsjord earth PE Phase Fas L Neutral Noll N Right-hand Höger sida side i+ i- Tryckgivare Pressure transmitter + - Tvåtrådsgivare Two-wire transmitter Weight: 1.7 kg Output Utsignal signal + _ Supply to the pressure transmitter Max supply Nominal 20 VDC voltage: (max 22.2 VDC) Current: Output power: Capacitance: Max 111 ma Max 0.62 W Max 175 nf for the pressure transmitter and cable ACCESSORIES * Impulse pipe kit, type VR-DR * Monoblock valve 2-TK with wall bracket * Flow measurement probe MFS Inductance Max 2.0 mh for the pressure transmitter and cable Internal resistance: 450 Ω AB MICATRONE REGULATOR Phone: Fax: Dalvägen 8 +46 8 470 25 00 +46 8 83 27 80 S-169 56 SOLNA http://www.micatrone.se