PSR-SCP- 24DC/ESD/5X1/1X2/300

Similar documents
Safety relays - PSR-SCP- 24DC/ESD/4X1/

DEK-OV- 12DC/ 24DC/ 3

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

SMKDSP 1,5/ 8. Extract from the online catalog. Order No.:

AKG 4 GNYE. Extract from the online catalog. Order No.:

KDS10/SO. Extract from the online catalog. Order No.:

MC 1,5/ 4-ST-3,5. Extract from the online catalog. Order No.:

FRONT 2,5-H/SA 5. Extract from the online catalog. Order No.:

MKKDSH 3/ 2. Extract from the online catalog. Order No.:

MACX MCR-EX-SL-RPSSI-I

MCR-C-UI-UI-DCI. Extract from the online catalog. Order No.:

MVSTBR 2,5/ 2-ST. Extract from the online catalog. Order No.:

MKDSN 1,5/ 4-5,08. Extract from the online catalog. Order No.:

SMKDS 2,5/ 2-5,08. Extract from the online catalog. Order No.:

KDSP 4. Extract from the online catalog. Order No.:

UTTB 4. Extract from the online catalog. Order No.:

UTTB 2,5. Extract from the online catalog. Order No.:

MSTB 2,5/ 4-ST. Extract from the online catalog. Order No.:

MVSTBW 2,5/ 5-ST. Extract from the online catalog. Order No.:

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

Extract from the online catalog

MSTB 2,5/ 3-ST. Extract from the online catalog. Order No.:

SAC-3P- 5,0-PUR/M12FR SH

SLKK 5. Extract from the online catalog. Order No.:

SAC-5P- 1,5-PUR/M12FS SH

VC-MEMV-S1. Extract from the online catalog. Order No.:

MKDS 3/ 4. Extract from the online catalog. Order No.:

High-current terminal block - UKH

Signal conditioner - MACX MCR-UI-UI-NC

VC-MEMV-K3. Extract from the online catalog. Order No.:

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

VC-MP-K1. Extract from the online catalog. Order No.:

Datasheet - PROTECT-IE-02

Feed-through terminal block - PT 10-TWIN

Safety Technique. SAFEMASTER Emergency Stop Module With Time Delay BH 5928, BI 5928

Safety Technique. Emergency Stop Module With Time Delay BH 5928, BI 5928

Switching power supplies CP range, Linear power supplies CP-L range. Content

QUINT-PS-24DC/24DC/10

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

E-STOP relays, safety gate monitors

DIK 1,5 General data Technical data General

Installation / Monitoring Technique

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

E-STOP relays, safety gate monitors

EMD-FL-3V Phase Voltage Monitoring Relay INTERFACE. Data Sheet. Description

EN GWT compliant Low profile: 15.7mm.618inch height 1a/1c 16A power relay

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)

MINI-PS AC/24DC/1.3

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF

650 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

QUINT-PS AC/24DC/40

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

Output of three-phase motors at 50 Hz and 400 V

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Online data sheet UE48-3OS2D2 UE48-3OS SAFETY RELAYS

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

Compact size 2 Form A and 2 Form A 1 Form B 35A power relays for energy management and industrial equipment. Conditions. Mirror contact mechanisms

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

Thermistor motor protection relays

Extract from the online catalog

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

General data. Technical data DIKD 1,5. General. Dimensions

2 pole (1 NO + 1 NC) 1 NO + 1 NC 2 NO + 2 NC, 3 NO + 1 NC 4 NO + 2 NC Rated current / Max. peak current Rated load AC1

STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Circuit diagram. Applications. Function. Function (Continued) Page 23 SNO 4062K /K-A /KM /KM-A

QUINT-PS/ 3AC/24DC/10

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Online data sheet UE48-2OS2D2 UE48-2OS SAFETY RELAYS

PLC INTERFACE With Leakage Current and Interference Voltage Suppression

ISOMETER IRDH575. Approvals

E-STOP relays, safety gate monitors

MINI MCR-SL-UI-I-LP-NC

QUINT-PS/ 3AC/24DC/40

PHOENIX CONTACT - 03/2007

Low profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b

Suitable for lighting and motor load, 1 Form A 50A latching relays

Online data sheet UE43-3AR3D2 UE43-3AR SAFETY RELAYS

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Electronic timer CT-TGD.22

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Contactors and Contactor Assemblies

Subject to changes 11/2003 Page 1/7

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

Type CP-S, CP-C & CP-A Switch mode

This data sheet is only valid in association with the IL SYS INST UM E user manual.

Transformers, Power Supply Units and Socket Outlets

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

MINI-PS AC/2X15DC/1

MINI MCR-SL-UI-f(-SP)

Power supply CP-E 24/2.5

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Transcription:

Extract from the online catalog PSR-SCP- 24DC/ESD/5X1/1X2/300 Order No.: 2981428 Safety relay with adjustable delay time 0-300 s, screw version Commercial data EAN 4017918975227 Pack 1 pcs. Customs tariff 85364900 Weight/Piece 0.4724 KG Catalog page information Page 24 (IF-2009) Product notes WEEE/RoHS-compliant since: 03/29/2007 http:// www.download.phoenixcontact.com Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation. The General Terms and Conditions of Use apply to Internet downloads. Technical data Input data Nominal input voltage U N 24 V DC Input voltage range in reference to U N 0.85... 1.1 Typical input current at U N Voltage at input/start and feedback circuit 155 ma DC Approx. 24 V DC PHOENIX CONTACT Inc., USA Page 1 / 6

Typical response time 70 ms (manual start) 600 ms (Auto-start) Typical release time 20 ms (undelayed contacts) Typical release time range 0.2 s... 300 s Concurrence input 1/2 Infinite Recovery time 1 s Max. permissible overall conductor resistance 11 Ω (Input and start circuits at U N ) Output data Contact type 3 enabling current paths undelayed, 2 delayed, 1 signaling current path undelayed Contact material AgSnO 2 Maximum switching voltage Minimum switching voltage Limiting continuous current Maximum inrush current Inrush current, minimum 250 V AC/DC 15 V AC/DC 6 A (N/O contact) 3 A (N/C contact) 6 A 25 ma Sq. Total current 55 A 2 (I TH 2 = I 1 2 + I 2 2 + I 3 2 + I 4 2 + I 5 2 ) Interrupting rating (ohmic load) max. Maximum interrupting rating (inductive load) Switching capacity min. Output fuse 144 W (24 V DC, τ = 0 ms) 288 W (48 V DC, τ = 0 ms) 77 W (110 V DC, τ = 0 ms) 88 W (220 V DC, τ = 0 ms) 1500 VA (250 V AC, τ = 0 ms) 42 W (24 V DC, τ = 40 ms) 40 W (48 V DC, τ = 40 ms) 35 W (110 V DC, τ = 40 ms) 33 W (220 V DC, τ = 40 ms) 0.4 W 6 A fast blow (undelayed) C6 (24 V AC/DC) automatic device (undelayed) 10 A gl/gg NEOZED (delayed) General data Width Height Depth 45 mm 114.5 mm 99 mm PHOENIX CONTACT Inc., USA Page 2 / 6

Ambient temperature (operation) -20 C... 55 C Ambient temperature (storage/transport) -20 C... 70 C Service life mechanical Mounting position Category in acc. with EN 954-1 Performance Level as per ISO 13849-1 Functional safety (SIL) Stop category Name Approx. 10 7 cycles Any 3 (For delayed contacts) 4 (For non-delayed contacts) d (For delayed contacts) e (For non-delayed contacts) SIL 2 as per IEC 61508 for delayed contacts SIL 3 as per IEC 61508 for undelayed contacts SIL 2 as per IEC 62061 for delayed contacts SIL 3 as per IEC 62061 for undelayed contacts 0 (For non-delayed contacts) 1 (For delayed contacts) Standards/regulations DIN EN 50178/VDE 0160 Rated surge voltage / insulation Rated insulation voltage Pollution degree 2 Surge voltage category MTTF d Air and creepage distances between the power circuits 4 kv / basic isolation, (safe isolation, reinforced insulation and 6 kv between the enabling current paths (13/14, 23/24, 33/34) and the remaining current paths and between 13/14, 23/24, 33/34 between each other.) 250 V III Approx. 65 years T10d DC PFH 6.5 years (maximum usage time of the device) 60% (low) for delayed contacts > 90% (medium) for undelayed contacts High demand: 1.1 x 10-7 1/h (proof test interval (T 1 ): 20 months) for delayed contacts High demand: 1.2 x 10-8 1/h (proof test interval (T 1 ): 33 months) for undelayed contacts PFD AV Low demand: 5.0 x 10-3 (proof test interval (T 1 ): 20 months) for delayed contacts Low demand: 9.6 x 10-4 (proof test interval (T 1 ): 33 months) for undelayed contacts Connection data Conductor cross section solid min. 0.2 mm² PHOENIX CONTACT Inc., USA Page 3 / 6

Conductor cross section solid max. 2.5 mm² Conductor cross section stranded min. 0.2 mm² Conductor cross section stranded max. 2.5 mm² Conductor cross section AWG/kcmil min. 24 Conductor cross section AWG/kcmil max 12 Stripping length 7 mm Screw thread M3 Type of connection Screw connection Certificates / Approvals Certification BG, CUL Listed, GOST, UL Listed Drawings Circuit diagram 1 = logics a = RESET b = Emergency stop Two-channel emergency stop circuit with cross circuiting detection and monitored reset button (bridge on S33/S35: Automatic activation), suitable up to safety category 4. PHOENIX CONTACT Inc., USA Page 4 / 6

a = RESET b = Emergency stop Single-channel emergency stop circuit with monitored reset button (bridge on S33/S35: Automatic activation), suitable up to safety category 2, safety category 4 only when automatically disconnecting switches are used and cables are installed in separate plastic sheaths. a = RESET b = semiconductor output Two-channel limit switch monitoring with semiconductor output and monitored reset button (bridge on S33/S35: Automatic activation), suitable up to safety category 4 depending on the limit switch. PHOENIX CONTACT Inc., USA Page 5 / 6

Address PHOENIX CONTACT Inc., USA 586 Fulling Mill Road Middletown, PA 17057,USA Phone (800) 888-7388 Fax (717) 944-1625 http://www.phoenixcon.com 2009 Phoenix Contact Technical modifications reserved; PHOENIX CONTACT Inc., USA Page 6 / 6