Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

Similar documents
ET-3888 True RMS Clamp Meter. User Manual

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

User Guide. Digital AC/DC Clamp Meter Model 38394

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

User s Guide. Digital AC/DC Clamp Meter Model 38394

OPERATOR S INSTRUCTION MANUAL

ATK Clamp Meter

Pen-type DIGITAL MULTITESTER

CONTENTS MS2033A. 1.Introduction Safety Information...01

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

Multifunction Digital

INSTRUCTION MANUAL UTL260

User Manual Digital Clamp Multimeter. model no.: MSR-C600

AC Clamp Meter + Phase Rotation Tester

MS2030 CAT III 600 V A V AUTO RS232

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

Digital Clamp Meter Model: &

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

R/C SMD Tweezers Multimeter Model RC200

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

User Guide. AC/DC Mini Clamp Meter. Model

400Amp True RMS AC Clamp Meter + NCV

AC/DC CLAMP METER USER S MANUAL

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

400Amp True RMS AC/DC Clamp Meter Model EX613

AMM-1022 Digital Multimeter USER`S MANUAL

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

User s Guide. 400A AC/DC Clamp Meter. Model MA220

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

Mini Clamp Meter Model:

200Amp AC Clamp Meter + NCV Model MA250

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

312, 316, 318. Clamp Meter. Users Manual

UT207A/208A/209A Operating Manual. Table of Contents

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

MT /6 Smart Digital Clamp Meter. User s Manual 1 st Edition, 2016 Copyright by Prokit s Industries Co., Ltd.

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

User's Manual. Clamp-on Power Datalogger. Model

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

ACA LEAKAGE TESTER OPERATION MANUAL. auto range, true rms. Model : DL-9954

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

Sales: Technical: Fax:

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

OPERATOR S INSTRUCTION MANUAL

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

Digital Clamp Meter (TRMS) Model : 2727

374/375/376 Clamp Meter. Users Manual

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

User Guide. 4 wire Earth Resistance Tester Model GRT Washington Street Melrose, MA Phone Toll Free

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

NOTE: Fully read and understand this manual before using this Digital Multimeter.

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

USER'S MANUAL DMR-6700

Instruction Manual ICM A9 Electrical Clamp Multimeter EN FR IT DE ES

Model True RMS AC/DC 30A Mini Clamp-on Meter. User Guide

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

User Manual 4 wire Earth Resistance Tester Model GRT300

HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

MS8223A. CAT.IIi 600 V

Model: &

MODEL: D03128 CLAMP METER

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

DM-46 Instruction Manual

Instruction Manual IDM 98-III & IDM 99-III Digital Multimeters

True RMS Digital Multimeter Model:

374/375/376 Clamp Meter

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

Digital Clamp Meter. User Manual

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

IDM 98-III & IDM 99-III Digital Multimeters

1.General instructions Specifications Description...7

2,000 counts, 200 Amp ACA/DCA, 600 V ACV/DCV, True RMS, OHMS, Continuity, Hold, Peak Hold FORK CURRENT TESTER. Model : FT-9950

Instruction Manual IDM 61/62T Digital Multimeter EN DE ES IT FR

KMD-S04 Multímetro de bolsillo

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

DM-45 Digital Multimeter

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

Table of Contents Title Page

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

Model DIGITAL MULTIMETER

8PK-ST1520 Digital Earth Resistance Tester

# Digital Multimeter

MS2109A AC/DC Clamp Meter. User Manual. Contents

400Amp True RMS AC/DC Clamp Meter with IR Thermometer Model EX623

netzerotools.com 374/375/376 Users Manual Clamp Meter

Transcription:

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

TABLE OF CONTENTS / EN TITLE TABLE OF CONTENTS PAGE 1. SAFETY INFORMATION... 1 2. TECHNICAL SPECIFICATIONS... 2 3. PARTS & CONTROLS... 6 4. OPERATING INSTRUCTIONS... 9 5. MAINTENANCE... 15 6. BATTERY REPLACEMENT... 16 12/09/11 Version No. 00

SAFETY INFORMATION / EN 1. SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter. To avoid damage to the instrument do not exceed the maximum limits of the input values shown in the technical specifications tables. Never measure current while the test leads are inserted into the input jacks. Do not use the meter or test leads if they appear to be damaged. Use extreme caution when working around bare conductors or bus bars. Accidental contact with the conductor could result in electric shock. Use the meter only as specified in this manual; otherwise, the protection provided by the meter may be impaired. Read the operating instructions before use and follow all safety information. Use caution when working with voltages above 60VDC or 30VAC RMS. Such voltages pose a shock hazard. Before taking resistance measurements or testing acoustic continuity, disconnect circuit from main power supply and all loads from circuit. Safety symbols on the meter: Caution, refer to this manual before using the meter. Dangerous voltages. Dangerous voltages. Meter is protected throughout by double insulation or reinforced insulation. When servicing, use only specified replacement parts. Comply with EN-61010-1, IEC 1010-2-032 12/09/11 Version No. 00 EN-1

TECHNICAL SPECIFICATIONS / EN 2. TECHNICAL SPECIFICATIONS 2-1 General Specifications Environment conditions: 1 Installation Category III 600V 400A 2 Pollution Degree 2 3 Altitude up to 2000 meters 4 Indoor use only 5 Relatively humidity 80% max. 6 Operation Ambient 0 to 40 Maintenance & Clearing: 1 Repairs or servicing not covered in this manual should only be performed by qualified personnel. 2 Periodically wipe the case with a dry cloth. Do not use abrasives or solvents on this instruments. Maximum Voltage between any terminal and earth ground : 600Vrms. Operating Principle:Dual slope integration Display:3 3/4 digit liquid crystal display (LCD)Max. reading 3999. Automatic indication of functions and symbols. Range Selection:Automatic. Over Range Indication: LCD will display OL. If measured value is over 4000V the LCD will display OL. (ACV & DCV range). EN-2 12/09/11 Version No. 00

TECHNICAL SPECIFICATIONS / EN Low Battery Indication: The + is displayed when the battery voltage drops below the operating voltage. Power Supply:Two 1.5V, AA (UM-3) battery. Battery Life:100hr approx. Polarity:Automatic polarity display for negative input. Auto power OFF time:30 minutes Operating Temperature and Humidity: 0 to 40 ( 32 to 104 ) ( R.H.<80% non-condensing ) Storage Temperature and Humidity: -10 to 60 ( 14 to 140 ) ( R.H.<70% non-condensing ) Dimensions:192 64 31 mm Weight:250g. approx. ( battery included ). Accessories:Instruction manual, Test leads, Carry Case. Jaw Opening Diameter:Cables φ25.4 mm. 12/09/11 Version No. 00 EN-3

TECHNICAL SPECIFICATIONS / EN 2-2 Measurement Specifications Alignment Marks 1. Position the conductor within the jaws at the intersection of the indicated marks as much as possible in order to meet this meter s accuracy specifications. 2. If the conductor is positioned elsewhere within the jaws, the maximum additional error result is 1.5 percent. Measurement Limits: AC Amperes : 1A to 400A AC Voltage : 1V to 600V DC Voltage : 0V to 600V Resistance : 0.3Ω to 400Ω Accuracy : ±(% of reading + number of digits) at 18 to 28 ( 64 to 82 ) with relative humidity to 80%. AC Current(Autorange) Range Resolution Accuracy 40A 0.01A 400A 0.1A Overload protection Frequency Response ±(2%+10) 660A 50 / 60 Hz EN-4 12/09/11 Version No. 00

TECHNICAL SPECIFICATIONS / EN DC Voltage(Autorange) Range Resolution Accuracy 400V 0.1V 600V 1V AC Voltage(Autorange) Range Resolution 400V 0.1V 600V 1V 400V 0.1V 600V 1V Accuracy ±(1.5%+10) ±(3%+15) Resistance Ω(Autorange) Range Resolution Accuracy Input Impedance Overload protection ±(1%+5) 1M 660Vrms Input Frequency Overload impedance Response protection 1MΩ 50Hz to 60Hz 400Hz Open circuit Voltage 660Vrms Overload protection 400Ω 0.1Ω ±(1%+5) 0.4V 660Vrms Audible continuity Range Continuity beeper Open Circuit Voltage Overload protection 60Ω 0.4V 660Vrms 12/09/11 Version No. 00 EN-5

PARTS & CONTROLS / EN 3. PARTS & CONTROLS 4 1 9 5 6 10 2 7 3 8 1 Jaw opening trigger. 2 Function switch [Fig-2] 3 COM measuring input terminal : Connect negative lead ( black test lead ) for voltage, resistance, continuity measurement as a common reference. EN-6 12/09/11 Version No. 00

PARTS & CONTROLS / EN 4 Transformer jaws : Pick up the AC current flowing through the conductor. 5 Data Hold Button : Press it once to hold the measured value and store the value in memory. Press again to release hold function. 6 AC/DC button. 7 LCD Display : Digital LCD with indications for measurement values, unit symbols, decimal point, polarity, over range, and low battery etc. 8 VΩ input terminal : Connect positive lead ( red test lead ) for voltage, resistance, continuity, measurement. 9 NCV (Non Contact Voltage) LED. 10 NCV function button : Press and hold this button to enable the NCV function. 12/09/11 Version No. 00 EN-7

PARTS & CONTROLS / EN LCD Display 1. Negative Polarity : Automatically indicates negative inputs. 2. Auto-range Mode : When the meter is in voltage range or current range, the proper scale will be selected automatically. 3. DC input indicator. 4. Data Hold Indicator. 5. AC input indicator. 6. Low Battery : Appears when battery charge is insufficient. 7. Ampere measuring indicator. 8. Voltage measuring indicator. 9. Ohm measuring indicator. EN-8 12/09/11 Version No. 00

OPERATING INSTRUCTIONS / EN 4. OPERATING INSTRUCTIONS 4-1 Measurement Procedures 1). Make sure that the selected range is suitable for the measurement to be taken. 2). If the current under measurement is higher than the selected value for a long period, overheating may take place, compromising the safety and operation of inner circuits. 3). Do not measure currents on uninsulated high-voltage conductors > 600V to avoid risks of discharge and/or incorrect readings. 12/09/11 Version No. 00 EN-9

OPERATING INSTRUCTIONS / EN 4-2 AC Current Measurements WARNING Make certain that all test leads are disconnected from the meter terminals. 1). Set the function switch to the A range. 2). Clamp the current transducer (jaw) around one of the conductors under test. Make sure that the clamp jaw is fully closed. 3). Read the display value. CORRECT INCORRECT [Fig-3] [Fig-4] EN-10 12/09/11 Version No. 00

OPERATING INSTRUCTIONS / EN 4-3 DC Voltage Measurements WARNING Maximum input voltage for the DC VOLT Range is 600VDC. Do not attempt to take any voltage measurement that exceeds 600VDC to avoid electrical shock and/or damage to the instrument. 1). Set the function switch to the V range. 2). Press / button to select DC function. 3). Connect the black and red test leads to the COM and + terminals respectively. 4). Connect the test leads to the circuit being measured and read the displayed value. [Fig-5] 12/09/11 Version No. 00 EN-11

OPERATING INSTRUCTIONS / EN 4-4 AC Voltage Measurements WARNING Maximum input voltage of AC VOLT Range is 600Vrms Do not attempt to take any voltage measurement that exceeds 600Vrms to avoid electrical shock hazard and/ or damage to the instrument. 1). Set the function switch to the V range. 2). Press / button to select AC function. 3). Connect the black and red test leads to the COM and the + terminals respectively. 4). Connect the test leads to the circuit being measured and read the displayed value. [Fig-6] EN-12 12/09/11 Version No. 00

OPERATING INSTRUCTIONS / EN 4-5 Resistance Measurement WARNING Before taking any in-circuit resistance measurement, remove power form the circuit being tested and discharge all capacitors. 1). Set the function switch to Ω range. 2). Before taking resistance measurements, make sure the circuit is not live and discharge any capacitors present in the circuit. 3). Connect the black test lead to the COM terminal and the red test lead to the + terminal. 4). Connect the test leads to the circuit being measured and read the displayed value. [Fig-7] 12/09/11 Version No. 00 EN-13

OPERATING INSTRUCTIONS / EN 4-6 Continuity Measurement WARNING Before taking any in- circuit measurement, remove power from the circuit being tested and discharge all capacitor in the circuit. CONTINUITY MEASUREMENT 1). Connect red test lead to the + terminal and black test lead to the COM terminal. 2). Set range switch to the Ω position. 3). Remove power from the circuit being tested and discharge all capacitors. 4). Connect the test leads in the circuit being measured. 5). The internal sounder will operate if the resistance is below 60Ω. Note: Continuity test is available to check open / short circuits. 4-7 NCV (Non Contact Voltage) Function Press and hold the NCV key at all functions except for OFF, the red NCV LED lights up and the internal sounder will operate when an electric field is detected by the sensor installed in the current clamp jaws. The NCV function indicates the presence of voltage in an electrical circuit or equipment without touching them. The NCV sensor can detect electrical fields only from the direction indicated in the follow figure. Note: Detection from a mains socket outlet is not possible. EN-14 12/09/11 Version No. 00

MAINTENANCE / EN 5. MAINTENANCE WARNING To avoid electrical shock or damage to the meter, do not permit water to get inside the case. Remove the test leads and any input signals before opening the case. Periodically wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents. 12/09/11 Version No. 00 EN-15

BATTERY REPLACEMENT / EN 6. BATTERY REPLACEMENT WARNING To prevent electrical hazard or shock turn the clamp meter off and disconnect test leads before removing back cover. The meter is powered by two 1.5V AA batteries. Replace batteries as soon as the + symbol is displayed. 1 Turn meter off. Disconnect and remove the test leads. 2 Position the meter face down. Unscrew the battery cover screw. Remove the battery cover 3 Replace the batteries. 4 Replace the battery cover. 5 Do not short-circuit used batteries, disassemble them, or throw them in a fire. Doing so may cause the batteries to explode. 6 Dispose of the used batteries in accordance with local regulations. Measurement Category III Application Measurement Category III is for measurements performed in the building installation. Examples include: measurements on distribution boards, junction boxes, socket-outlets and wiring and cables in the fixed installation. EN-16 12/09/11 Version No. 00