HALSEY TAYLOR OWNERS MANUAL Contour TM Series Barrier-Free Water Coolers Refrigerated Fountains with Back Panel

Similar documents
Halsey Taylor Owners Manual

Installation/Care/Use Manual Soft Sides Freeze Resistant Fountain

Preference Collection and Treatment Console INSTALLATION GUIDE

Preference Collection 5531 Accessory Console I NSTALLATION GUIDE

CALLAS THERMOSTATIC SHOWER SET

ONASSIS SHOWER SET INSTALLATION

EXIRA SHOWER SET INSTALLATION

Preference Collection 5543 Central Console INSTALLATION GUIDE

INSTALLATION INSTRUCTIONS

MALEKO WALL-MOUNT FAUCET INSTALLATION

Quick-Drain Installation Requirements

This product is designed for a water supply pressure range of 20 psi (137kPa) minimum to 80psi (550 kpa) maximum.

Quick-Drain Installation Requirements Large Volume Drainage Models

Installation Instructions

Owner s Manual #TSGUARD

Form No Assembly & Operating Instructions for: SAFETY PRECAUTIONS

Installation Instructions 8115F 8115SF

SERVICE INSTRUCTIONS Model 9670 Lubricant Pump

OB1U INSTALLATION INSTRUCTIONS. Interactive Flat Panel Over White Board Mount

STEWARD ECO T01-B INSTALLATION INSTRUCTIONS L URINAL (REAR INLET) K-4986T-ER( ) , 2010 Copyright Kohler China Ltd.

TITAN2-EDGE Public Access Computer Station Dual Track

New Product Release: October 2014 Boone Racks

Preference Collection 5580 Treatment Console INSTALLATION GUIDE


Product Instruction Booklet

GLENBROOK/GLENGUARD VITREOUS CHINA DRINKING FOUNTAIN/CUSPIDOR

INSTALLATION INSTRUCTIONS HEAVY DUTY TILT WALL MOUNT Model: PPH-2000

HYDRO-TOWER INSTALLATION INSTRUCTIONS

P a r k c o n s o l e s i n k a s s e m b l y i n s t r u c t i o n s

Geberit Duofix. Installation Manual Montageanleitung Instructions de montage Istruzioni per il montaggio

installation instructions WC Frame 1180mm with Dual Flush Cistern

D3976 RECESSED EXIT INSTALLATION INSTRUCTIONS

JARVIS. Model25CL-4,5,6 Hock Cutter and Loin Dropper. 25CL--5 Front Legs and Horns. 25CL--4 Hind Legs and Horns. 25CL--6 Loins

The MUELLER method of making a main to service connection using the MUELLER E-5 Small Drilling Machine. The main is drilled out under pressure.

INSTALLATION INSTRUCTIONS

MPA-9000 Universal Ceiling Projector Mount Kit

JEWEL, SAPPHIRE, STAR and NOVA Turntables

LATTIMORE SHOWER SET INSTALLATION

Installation Guide. Overview

Senior Swing. Caution

WOLF PUP LOOM TM & WOLF PUP LT LOOM TM

INSTALLATION GUIDELINES

ABM International, Inc. Navigator Assembly Manual

General Array Layout Sketch

installation instructions

WILLIS WALL-MOUNT FAUCET INSTALLATION

Bend-Tech Dragon Assembly Manual

Constable Oak Extension Dining Table

INSTALLATION INSTRUCTIONS FOR WALL TUB SETS, TWO HANDLE SHOWER SETS AND WALL LAVATORY SET VALVES NUMBERED: RC & RC

The MUELLER method of making a main to service connection using the MUELLER E-5 Small Drilling Machine. Hand or power. kpa/34.

Fixed Wall Arm. Installation Guide. Part number Rev E 2012 PolyVision Corporation All rights reserved

PORTABLE ADJUSTABLE BASKETBALL SYSTEM

ClearSpan Hydroponic Table Kit

Star Trac Turbo Trainer Assembly & Setup

CleanBench Laboratory Tables

Shetland Stalls Installation Instructions

MODEL 83 Pail Handler

Installation, Operation & Maintenance Manual

Product Data (500) Wall thickness not to exceed 3"

- 1 - P/N REV E 9/15

The Bowflex Revolution XP Home Gym Assembly Instructions. P/N: Rev ( /0 )

Installation and Maintenance Instructions

A-dec 574L and 575L Dental Lights on a Cabinet or Wall INSTALLATION GUIDE

HZ301 & HZ321. Standard and Junior Flush Valve Installation Instructions

HYDRO-TOWER INSTALLATION INSTRUCTIONS

Arlink 8000 Workstation

WADE 2-1. Universal Carrier. Exclusive Features of 400 Series Universal Carrier for Lavatories, Urinals, Drinking Fountains.

* * 98/9950WDC. Fire-Rated Devices include these. additional components. 1-Point Latch (LBL)

Interactive Monitor Arm

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

ZIP CLOUD SUSPENDED INSTALLATION MANUAL

Line volt rail & fixtures. Low volt quick connect fixtures with transformers

Bodyspray INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS DODGE RAM 2 & 4WD 1500 PART # P5058

Installation Instructions

Portable System Owners Manual Customer Service Center N53 W24700 South Corporate Circle Sussex, WI U.S.A.

Installation Instructions

Reliance SG800 Series Steel Water Gage Valves

INSTALLATION INSTRUCTIONS

LCD LIFT Flat Panel Display System Installation Manual. Table of Contents

Gared Pro-S Portable Backstop

INSTALLATION INSTRUCTIONS KK-K9-F14-K K9 KIT FOR FORD EXPEDITION

CBT LW BATCHING SYSTEM 25, 50, 100 & 200 INSTALLATION GUIDE

A500 ASSEMBLY & INSTALLATION INSTRUCTIONS

EPPA2-KIT DUAL MONITOR ARM CONVERSION

caroma marc newson wall basin mixer

LAN84207 Installation Instructions Single Point Hydraulic Kit for 50 Series STS Combines. 270 West Park Avenue Huron, SD

STOP. V00029AC Rev. 04 READ ALL OF THE FOLLOWING INSTRUCTIONS BEFORE REMOVING CABINET FROM SKID TOOL LIST. NET-ACCESS S-Type Network Cabinets

Pack Mount Instructions:

FRONT BUMPER INSTALLATION INSTRUCTIONS Toyota 4Runner

Shipping/Receiving The internal framework and fabric components may arrive in different shipments.

Hatch Whiteboard: Portable Stand Installation Instructions

EXIT DEVICE OPERATION FIRE DOOR LABELS, STRIKES AND FRAME SCREWS FOR INFORMATION CALL OR VISIT RITEDOOR.COM

Pressure Balance Shower Only Dual Control (Volume & Temperature) Ceramic Disc Cartridge Platinum Shower Trim Kit

Band-Master ATS Nano Pneumatic Banding Tool Operating Instructions

Fisher 667 Diaphragm Actuators Size 80 and 100

Rhino r VE/CE Pneumatic Level Detect Modules. Description S S. The assembly detects two conditions during the downward movement of the follower:

PULL-THRU USER S MANUAL

Custom. Options Guide. and. Installation Instructions. GE Monogram 36" Built-In Refrigerators. Models: ZIS36NY ZISW36DY ZISB36DY

Transcription:

HALSEY TAYLOR OWNERS MANUAL Contour TM Series BarrierFree Water Coolers Refrigerated Fountains with Back Panel Figure HRFSERQ Figure HRFERQ Figure HRFSRQ Figure Not Shown Model HRFSERQ HRFERQ HRFSRQ HRFESRQ Description Contour TM Series Dual Installation Contour TM Series Extended Reach Contour TM Series Standard Reach Contour TM Series Dual Reversed Installation INSTALLER Review these instructions before beginning installation. Be sure that installation conforms to all plumbing, electrical and other applicable codes. When installation is complete, ensure these instructions are left in the plastic bag provided inside the installed unit for future reference. Service to be performed by authorized service personnel only. NOTE: It is common practice to ground electrical hardware such as telephones, computers and other devices to available water lines. This can, however, cause electrical feedback in the plumbing circuit, which results in an electrolysis effect occurring in the fountain. This may result in water which has a metallic taste to it or has a noticeable increase in the metallic content of the water. When inspecting plumbing circuit, remember the line may be grounded some distance from the installation, and may occur outside the building or area in which the unit is being installed. This condition can be avoided (in most cases) by using recommended materials during installation. Any drain fittings provided by the installer should be made of plastic which will electronically isolate the fountain from the remainder of the building s plumbing circuits. 97800C (Rev. F /0)

Installation Package /4" O.D. TUBE WATER INLET TO COOLER /8" O.D. UNPLATED COPPER TUBE CONNECT COLD WATER SUPPLY BUILDING WATER INLET The components for installation are packed in three separate boxes, regardless of the type of unit being installed. The boxes contain the following: NOTE: WATER FLOW DIRECTION Figure 4 Water Supply Connections SERVICE STOP (NOT FURNISHED) Box No. : Wall Frame(s) Box No. : Remote Chiller, SJ8Q Box No. : Fountain(s), Arm(s) and Panels Additional materials, as noted in the Parts List, are also shipped in these boxes. Parts List Number Required Item Part No. Description HRFERQ HRFSRQ HRFSERQ HRFESRQ See Fig. 4 5 7 8 9 0 4 5 7 8 9 0 LK44 5005C 45C 559C 45C 45C 5098C 5544C C 757C 754890 5599C 550005 550008 55000 550005 89C 708C 87C 40045C 509C 7057C 70C 8C 708C 708C 580C Drain Retaining Nut Strainer & Ferrule Assy Bubbler Nipple Assy Push Button Push Button Sleeve Regulator Holder Bubbler Regulator Cap screw Screw #04 X.50 PHTC Strainer (Supplied with Chiller) Fountain ArmShort Fountain ArmExtended Bottom Cover PlateShort Bottom Cover PlateExtended Back Panel HRFSER Back Panel HRFESR Back Panel HRFER/SR Hex Nut Poly Tubing /4 (Cut To Length) BracketRegulator Mounting Lower Panel HRFSER/ESR Lower Panel HRFER/SR Union /4" Tee /4" Edge Trim 7 5 8 7 8 8 7 7 7, 8 7 7 8 4, 5, 9 8 8 8 8,, 8 8,, 8 7 8 7 4, 8 4, 8 9 5 8 97800C (Rev. F /0)

Models HRFSERQ & HRFESRQ. Cut a rectangular wall opening 7/ (95 mm) W x 7/4 (959 mm) H and 4/ (4 mm) above the floor line (see Figure ). The dimensions are required to obtain proper rim and bubbler heights for compliance with ANSI standard A7... Reinforce the wall opening on all sides to adequately support the water fountain. This reinforcement must support up to 50 lbs. static load and provide a means for securing the frame assembly in place. NOTE: Building construction must allow for adequate air flow on both sides, top and back of chiller. A minimum of 4 (0 mm) on both sides and top is required. See chiller installation for additional instructions.. Install plumbing and electrical roughins. A junction box for a () wire, 0 amp branch circuit is provided on the inside of the chiller. (Standard 0 Volts, 0 Hz, and single phase.) Figure 5 HRFSERQ RoughIn 4. Remove frames and related hardware from packaging. Release the two shelf rods by cutting cable ties. Attach the two frames together through the upright supports with (4) 5/ x /4 (9 mm) long bolts and nuts (provided). Tighten securely. MAKE SURE FRAME CONFIGURATION MATCHES THE COOLER TO BE INSTALLED REVERSED CONFIGURATION: HIGHER UNIT ON THE RIGHT STANDARD CONFIGURATION HIGHER UNIT ON THE LEFT Figure RoughIn Assembly DualStation Mounting Frames 97800C (Rev. F /0)

5. Install the frame assembly squarely in wall opening with frame upright support edges flush with the finished wall face. Secure the frame to the wall through holes with () 5/ bolts or screws (not provided). Tighten securely. NOTE: Be sure that frame is squared in location. Do not use less than required screw quantity and size.. Attach the chiller shelf support rods to the right side of the frame uprights at the second set of holes counting from the bottom and to the shelf at the () side holes. Line up the other shelf holes with the frame bottom holes and fasten the assembly to the wall opening using appropriately sized screws or bolts and nuts (not provided). MODEL HRFESR MODEL HRFSER 97800C (Rev. F /0) Legend Item Description A /4 O.D. Tube Water Outlet Connection B /8 O.D. Tube Water Inlet Connection C /4 O.D. Waste Tube Not provided D Electrical Inlet on Chiller Figure 7 HRFSERQ & HRFESRQ RoughIn Dimensions 4

Models HRFERQ HRFSRQ. Cut a rectangular wall opening 8/4 (475 mm) W x 7/4 (959 mm) H and 4/ (4 mm) above the floor line (see Figure 9). The dimensions are required to obtain proper rim and bubbler heights for compliance with ANSI standard A7... Reinforce the wall opening on all sides to adequately support the water fountain. This reinforcement must support up to 50 lbs. static load and provide a means for securing the frame assembly in place. NOTE: Building construction must allow for adequate air flow on both sides, top and back of chiller. A minimum of 4 (0 mm) on both sides and top is required. See chiller installation for additional instructions.. Install plumbing and electrical roughins. A junction box for a () wire, 0 amp branch circuit is provided on the inside of the chiller. (Standard 0 Volts, 0 Hz, and single phase.) Figure 8 HRFERQ/HRFSRQ RoughIn 4. Remove frame and related hardware from packaging. Release the two shelf rods by cutting cable ties. Figure 9 RoughIn Assembly SingleStation Mounting Frames 5 97800C (Rev. F /0)

5. Install the frame squarely in wall opening with frame upright edges flush with the finished wall surface. Place shelf inside frame and line up the () holes on each. Insert loose ends of rods into holes on sides of shelf panel. Using appropriately sized screws or bolts (not provided), fasten the shelf and frame to the bottom of wall opening. Secure the frame sides and top to the wall using (0) 5/ bolts or screws (not provided). NOTE: Be sure that frame is squared in location. Do not use less than the required screw quantity and size. MODELS HRFER/HRFSR HRFERQ*C HRFSRQ*C HRFSERQ*C HRFESRQ*C REQUIRED TOOLS AND MATERIALS These tables show special tools and/or additional materials (not provided) which are necessary to complete installation of these units: Special Tools Item Description Quantity NONE Additional Materials Item Description Quantity Unplated copper inlet pipe Service Stop HRFERQ/HRFSRQ/HRFSERQ/HRFESRQ INSTALLATION. Assemble and place frame in wall as shown on preceding pages.. Install chiller: Remove front panel of chiller. Remove and discard cardboard inner pack from between compressor and side panel. Slide chiller onto the shelf and position it to the left within the guides on the shelf. NOTE: Building construction must allow for adequate air flow on both sides, top and back of chiller. A minimum of 4 (0mm) on both sides and top is required. See chiller installation for additional instructions. Legend Item Description A /4 O.D. Tube Water Outlet Connection B /8 O.D. Tube Water Inlet Connection C /4 O.D. Waste Tube Not provided Figure 0 HRFERQ/HRFSRQ RoughIn Dimensions 97800C (Rev. F /0) Figure Chiller Installation. Make water supply connections. Inlet port is marked on the chiller (/4 O.D. copper tube). Bend the copper tube (provided) at an appropriate length from the chiller to opening in frame. Install the inline strainer (provided with chiller) by pushing it in until it reaches a positive stop, approximately /4 (9mm) on the marked chiller inlet port. Attach an unplated and deburred copper water inlet line and a service stop (not provided) to the inline strainer. Turn on the water supply and flush the line thoroughly. 4. Hang the upper panel on the mounting frame hanger: Align holes in the panel with the holes in the mounting frame. Be sure that panel is engaged with hanger at top of frame before releasing it.

. Remove elbow from end of ptrap and attach it to drain tube. Reattach elbow to ptrap and cut waste tube to required length using plumbing hardware and trap as a guide. 7. Make connection between remote chiller outlet tube and fountain(s). Outlet port is marked on the chiller (/4 O.D. copper tube). Install a /4 union/tee (provided) on the marked chiller outlet port. Insert the /4 poly tubing coming from the fountain(s) into the union/tee. Turn on water supply and check for leaks. Figure HRFSERQ Upper Panel Installation 5. Install fountain: Remove access cover plate on underside of fountains and SAVE the screws. Mount the fountains to the upper panel and frame with (4) 5/ x /4 (9mm) long bolts and nuts provided. Tighten securely. Note: With HRFSERQ and HRFESRQ models, the standard reach fountain must be mounted at the upper position on panel. DO NOT SOLDER tubes while inserted into the strainer as damage to orings may result. 8. These products are designed to operate on 005 PSIG supply line pressure. If inlet pressure is above 05 PSIG, a pressure regulator must be installed in the supply line. Any damage caused by connecting these products to a supply line with pressure lower than 0 PSIG or higher than 05 PSIG IS NOT covered under warranty. 9. Make electrical connections to the chiller. See chiller instructions. 0. Check stream height from bubbler. Stream height is factory set at 540 PSI. If supply pressure varies greatly from this, adjust the screw on regulator item 9 by using a small screwdriver through the small hole in the push button item 5 (See Fig.7). Clockwise adjustment will raise stream height and counterclockwise movement will lower stream height. For best adjustment, stream height should be approximately / (8mm) above the bubbler guard. (See Figure ).. Mount lower panel. Loosen the two () #04 x 5/8 (mm) screws at frame bottom lip. Slide upper tongue of lower panel under lower edge of already installed upper panel. Tighten previously loosened screws securely.. Replace bottom access panel to fountain basin using screws provided. Tighten securely. Figure HRFSERQ Fountain Installation TO BUBBLER 7 7 0 CHILLER OUTLET CHILLER INLET Figure 4 HRFSERQ Lower Panel Installation Figure 5 HRFSERQ/HRFESRQ Tube Routing 7 97800C (Rev. F /0)

TO BUBBLER 7 7 CHILLER OUTLET CHILLER INLET Figure Stream Height 5 7 Figure 9 HRFERQ/HRFSRQ Tube Routing TROUBLESHOOTING & MAINTENANCE 0 8 Figure 7 Push Button Assembly 9 Orifice Assembly: Mineral deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from the orifice by poking with a small round file not over /8 diameter, or using a small diameter wire. DO NOT file or cut orifice material. Stream Regulator: If orifice is clean, regulate flow as in Step 0 of the installation instructions. If replacement is necessary, see parts list for correct regulator part number. 4, 8 SEE FIG. 5 Actuation of Quick Connect Water Fittings: Cooler is provided with leadfree connectors which utilize an oring water seal. To remove tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on the tubing. (See Figure 0) To insert tubing, push tube straight into fitting until it reaches a positive stop (approximately /4 ). SEE FIG. 7 7, 4 8 Figure 8 Fountain Assembly Side View Figure 0 Quick Connect Fittings CAMDEN COURT OAK BROOK, IL 05 0.574.500 PRINTED IN U.S.A. 97800C (Rev. F /0) www.drinkingfountaindoctor.com 80058588 8