CONCEALED ROD CRASH BAR PR-7085 SERIES EXIT DEVICE ASSEMBLY DETAILS PR mm. 10mm. Lock cylinder. 10mm. Cross bar length (see note #8) Dogging

Similar documents
CONCEALED VERTICAL ROD PANIC EXIT DEVICE

INSTALLATION INSTRUCTIONS CRL JACKSON

33/3527A. Devices covered by these instructions: 33/3527A-F (Fire) Surface Vertical Rod Exit Device

EXIT DEVICE OPERATION FIRE DOOR LABELS, STRIKES AND FRAME SCREWS FOR INFORMATION CALL OR VISIT RITEDOOR.COM

OVERVIEW. Mounting Post (2 places) Cylinder Cam. Handing Pin

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2

4600 Series Rim Narrow Stile Exit Device Installation Instructions I-ED01162

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

INSTALLATION INSTRUCTIONS CRL JACKSON

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY.

33/35A Series. Devices covered by these instructions: Rim Exit Device. CD33/35A Rim Exit Device EL33/35A Rim Exit Device SS33/35A Rim Exit Device

INSTALLATION INSTRUCTIONS CRL JACKSON

* * 98/9950WDC. Fire-Rated Devices include these. additional components. 1-Point Latch (LBL)

Installation Instructions

*D-1030* 1 PARTS CHECK 8 REVERSING INSTRUCTIONS F-XX-C & XX-C D Customer Service. Installation Instructions. Exit Devices

98/9927. Devices covered by these instructions: Surface Vertical Rod Exit Device

Active Push Bar. Safety glasses Measuring tape Level Pencil Power drill Drill bits: 5/32, 3/4 Center punch Phillips screw driver

Important: Read this first!

Note: The dimensions of the Template are shown in inches. See attached page for the Metric Conversion Table for millimeters.

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

ED5800 (A) Series. Installation Instructions. Concealed Vertical Rod. Exit Device WARNING

ED1100 /1100F SERIES RIM EXIT DEVICE INSTALLATION INSTRUCTIONS

MORTISE LOCK INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS. Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING

FRAME PREPARATION 3900/8900 SURFACE LATCH CONCEALED ROD EXIT DEVICE INSTALLATION INSTRUCTIONS HOW TO FIND BACKSET. Date: Appvd: *13/16 2 3/4" 3/4 HOLE

D3976 RECESSED EXIT INSTALLATION INSTRUCTIONS

ED5200(A) Series Rim Exit Devices

Safety glasses Measuring tape Level Pencil Power drill Center punch Phillips screw driver Saw horse

WPS crew Doors Installation instructions

33/3550AWDC. Fire-Rated Devices include these. additional. components. 1-Point Latch (LBL) Metal Edge Wrap required for 60 and 90-minute applications

LATCHBOLT FILLER PLATE ASA FILLER PLATE A. SINGLE DOOR B. DOUBLE DOOR WITH MULLION C. DOUBLE DOOR WITHOUT MULLION END COVER MOUNTING BRACKET

Vigilant Cigar Humidor Vault. Assembly Instructions

1790 Touchbar. Installation Instructions. Rim Panic Device ININST Index:

ED5200(A) Series Rim Exit Devices

7110(F), 7170(F)(LBR) Surface Vertical Rod Exit Device Series Installation Instructions

FIGURE 1, TYPE B Active leaf opens both doors. Overlap plates installed on the inactive

Shim (2) Supplied. Strike Plate. (3) x 5/8" PFHMS or 10 x 1" PFHWS. Top Latch. (3) x 1/4" PRHMS. Latch Cover. (2) 8 x 3/8" PFH AB SMS

351 DOOR CLOSER WITH DOUBLE LEVER ARM (OP) INSTALLATION INSTRUCTIONS

How To Measure Your Finished Opening

ASSA ABLOY. Installation Instructions. MP9800 Series Multi-Point Lock. MP9800 Series Multi-Point Lock Wood Doors. Wood Doors ASSA ABLOY.

ASSEMBLY INSTRUCTIONS DIY WALL BED KIT QUEEN BI FOLD DOOR CABINET & MECHANISM. Tools Required For Assembly. 6.5mm Masonry Drill Bit

ASSA ABLOY. Installation Instructions. MP9800 Series Multi-Point Lock. MP9800 Series Multi-Point Lock Hollow Metal & Aluminum Doors

1530(F) Mortise Exit Devices Installation Instructions

Sentinel Series Cigar Humidor End Tables

Sentinel Series Cigar Humidor End Tables

BEFORE STARTING INSTALLATION

INSTALLATION INSTRUCTIONS FOR VERTICAL ROD ASSEMBLY, MODEL VRA-143

WD WD7000 Series

* * 9875/ Customer Service #10-24 # Dogging Key (use to lock down pushbar)

INSTALLATION GUIDE 2009-CURRENT HUMMER H3T PRODUCT CODE:

Installation Instructions

Tools Required. * When installing on a fire door, please see instructions below. *

Item # Thanks for shopping with Improvements!

P USHbutton 500 series

SSRLS-3 / SSRLU-3 Installation Instructions

1500(F) Rim Exit Devices Installation Instructions

SERIES I MILLING MACHINES

4600 INSTALLATION INSTRUCTION W/ 2190

Installation Instruction

376E Series Exit devices

INSTRUCTIONS TS93 GSR PT RIGHT HAND ACTIVE LEFT HAND INACTIVE RIGHT HAND INACTIVE LEFT HAND ACTIVE

Installation Instructions FE6800 Series Multi-Point Lock

ED5200S(A) Series ED5200S(A) Series x M107 Windstorm Series SecureBolt Exit Device

Quill Stop V2 Installation Guide 11/16/2014

Queen Wingback Bed King Wingback Bed

Pet Door Panel Installation Manual

Installation Instructions Model # TEL-100 / 200 Manual Locking or Self Locking

Required Tools: Suggested Additional Tools: 1 Cordless Drill with Robertson Bits 1 Ratchet Wrench 1 7/16 or 11mm socket 1 7/16 or 11mm Gear Wrench

INSTALLATION INSTRUCTIONS

ASSEMBLY INSTRUCTIONS MANUAL

INSTALLATION INSTRUCTIONS

1.8. Panic Exit Devices. ED22 Series, ED2227 Series, ED22M Series, Accessories and Parts. Mechanics

PRL GLASS PANIC HANDLES DOOR MANUAL PL100 PANIC HANDLE PL100-A SERIES. For all glass doors

MANUAL e130. Wallstation

Rim-Lock Door Set Installation Instructions

LOWLINE SINGLE FOLD DOWN WALL BEDS

Box Track INSTALLATION INSTRUCTIONS

Installation Type. Edge of Door. Pull (Hinge) Side Mounted. Hinge Edge of Door. Push (Stop) Side Mounted

Assembly Instructions

Custom Wood Frame Overlay for Glass Doors Installation Instructions

American Morse Equipment

Cook's Corner Kitchen Assembly Instructions

Melamine Plastic Laminate. Toilet Partition Installation Manual

RH-412 STEEL DOORS INSTALLATION INSTRUCTIONS

98/ Customer Service # Dogging Key (use to lock down pushbar)

Therma-Tru Door Gallery Setup Instructions Swing Unit with Hardware Kit - Hardware Part # MADGSWU15 (Swing Unit) Part # MADGHKSU10 (Hardware Kit)

Thanks for shopping with Improvements! Item #553001

EASY SPIN ASSEMBLY GUIDE MAN CT Rev. B Model CT09001

Congratulations! You are now on your way to enriching your life with! Figure #5. Step 5 Install the Dummy Deadbolt. Step 3 Drill the Door

Privacy Wall & Glass Selections Pivot-Hinged Door (For products manufactured after September 14, 2009)

Installation Instructions

Installation Instructions for 45H & 47H Mortise Locks

Preference Collection and Treatment Console INSTALLATION GUIDE

v1.0 ASSEMBLY GUIDE Mia Wide Bookcase

Hookbolt. Non Handed. Flat LH Bevel RH Bevel Radius Radius with Weather-strip. Radius Flat Bevel

Oxford Stalls Installation Instructions

Installation Instructions for 45HW & 47HW Electrified Mortise Locks

MP Panic Exit Police Lock. Review Of March 2004 Installation

Joiner Kit For Models N388, C450, E402B, E411T, E415H, E440T, E442B, E521T and E522B

Transcription:

Floor line TITLE ASSEMLY DETAILS PR-7085 4:02 Hinge stile (inside) Lock stile (inside) Lock stile (outside) Drill 5mm (.20) and tap 1/4-20 (2) Drill 7mm (.266) holes (2) 9mm 12mm See note #6 160mm 9.5mm (.75) For lock cylinder only Drill 5mm (.20) clearance holes (2) and 6mm cylinder hole 10mm Drill 5mm (.20) & countersink () Drill 5mm (.188) and countersink (2) 9.5mm (.75) 51mm Lock cylinder 16mm 24mm 16mm 48mm 10mm 906mm to floor INSTALLATION OF ATUATOR LINK ross bar length (see note #8) Actuator link 160mm Actuator pin onnecting pin 47.5mm (1.875) Place actuator link over actuator pin & connect using connecting pin Dogging pin HEADER PREPARATION Adjustment screw Drill mm (.125) holes (4) Trip bracket used as release when door stop is not used 40mm 22mm x 27mm hole for strike or hole if strike not used 906mm 22mm Strike THRESHOLD PREPARATION Drill mm (.125) holes (2) Strike 22mm x 27mm hole for strike or hole if strike not used 10mm 19mm 14mm Drill 5.2mm (.20) and countersink () See note #6 MOUNTING INSTRUTIONS 1. Determine hand of door and prepare inside of lock and hinge stiles as show. 2. If ylinder Key Lock is to be used, prepare inside and outside of lock stile as shown.. Insert Rod and ase Assembly into lock stile and secure with (2) 1/4-20 Shoulder Studs. 4. If Key Lock is used, insert ylinder in Mounting Pad and secure with Locking Ring. Install using (2) #8-2x49mm Flat Head Machine Screws. 5. Position Exit Pad over stile and attach Actuator Link to Actuator Pin using onnecting Pin provided. Place on stile over 1/4-20 Shoulder Studs and tighten Socket Head Set Screws to secure in place. 6. Adjust length of top and bottom Latch olts by turning in or out. When the Panic Arm is fully depressed, the Latch olts should be slightly recessed from flush with the top and bottom of the door. NOTE: Flat notch side of olt must face the outside of the door. Install top and bottom Latch olt Guides using (6) #10x1mm Flat Head Self-threading Screws. 7. Install (2) 1/4-20 Shoulder Studs on hinge stile. Place other Exit Pad over Studs and tighten Socket Head Set Screws to secure in place. 8. Measure distance from inside edge to inside edge of Exit pads for proper ross ar length. ut ross ar. AUTION: ross ar length must be within ± 1mm for unit to function properly. 9. Loosen Set Screws on hinge stile Exit Pad and install ross ar using (2) 1/4-20x Oval Head Self-threading Screws. Tighten Set Screws to secure in place. 10. Prepare header and threshold as shown. If Header and Threshold Strikes are required, install using (4) #8x Flat Head All-purpose Screws. DOGGING EXIT DEVIE USING DOGGING PIN: Fully depress ross ar and hold, push up Dogging Pin with screwdriver and rotate 90 o in either direction. TO RELEASE EXIT DEVIE: Hold ross ar down and rotate Dogging Pin with screwdriver in either direction until Dogging Pin releases. DOGGING EXIT DEVIE USING YLINDER KEY: Fully depress ross ar and hold, turn Key clockwise approximately 60 o, return Key to centre and remove. TO RELEASE EXIT DEVIE: Turn key counterclockwise 90 o, return Key to centre and remove. MARH 2014

ASSEMLY DETAILS PR-7085 4:0

ASSEMLY DETAILS PR-7085 4:04 Secure trip bracket to header Secure fixing screws (1) thru stile into lock mechanism, and screws (2) into tapped holes in opposite stile. 1 2 1 2 Offer handle to stile and connect actuator link to actuator pin using connecting pin (A) provided. Position handle onto fixing screws () and secure using grub screws (). A Secure guide block to stile using screws () MARH 2014

FITTING GUIDE FOR DOGGING PIN DP-71 4:05 1) Remove securing screw in back of handle unit 2) Once securing screw is removed existing pin should be ejected by internal spring ) Replace existing pin with knurled pin (retaining original spring) 4) Replace securing screw holding knurled pin in far enough that notch on dogging pin can locate on securing screw MARH 2014

4:06 RIM YLINDERS PR-7085 LOK ODY AND MOUNTING PAD DETAILS AND DIMENSIONS 25.5 19 9.5 R4 R18 R 785 AL Rim cylinder & MP 786 mounting pad for use with 7085/7100 panic exit devices 51 7 R-785-AL Rim cylinder & mounting pad for use with 7085/7100 panic exit devices A = 29.5 Rim yliner table details R - 785 R 795 AL Rim cylinder = 25.0 for = 7.0 use with 7095 panic exit device D = 12.0 E = 6.0 A = 2.5 = 28.6 = 5.0 D= 1.0 E = 10.0 A = 7.5 =.6 = 7.0 D = 21.0 E = 5.0 A = 5.5 = 49.0 = 5.0 D = 14.0 E = 27.0 R - 787 R - 789 R - 791 R15 6.5Ø 6.5 10.5 R7.5 21 46mm Door Stile MP786 S = 57 mm 49mm Door Stile 54mm Door Stile 67mm Door Stile Mounting Pads MP790 MP790 MP792 Screw Length 16.5 S = 65 mm S = 65 mm S = 90 mm

KEY ONTROLLED OUTSIDE TRIM LOKING HANDLE FOR PR7085, PR7085P & PR7100 EXIT DEVIES 4:07 LH-725 Locking handle Key ontrolled Outside trim for use with PR7085, PR7085P, and PR7100 concealed rod Panic Devices. Uses Axim screw in Mortice cylinder with MS type AM. 45 22 Not handed. (Field reversible). All Axim Panic Exit Hardware is supplied with comprehensive instructions and full size templates for ease of installation. Handle rotation 45 anti-clockwise from centre. OR Handle rotation 45 clockwise from centre. See 4:08 for lock fitment. 29 110 1 181 172 57 Ensure operating dowel is engaged in slot. To change the hand of the trim, remove screw and reverse lever. Keep the black side of star washer facing upwards. Ensure screw is locked tight. utting Prep to fit to outer face. Dashed lines indicate panic exit position (4.5 & 6). Ensure the cylinder and cam operate the lock arm prior to installation.

LOKING HANDLES DETAILS AND DIMENSIONS LH-725 AND PR-7085 FARIATION DETAIL 4:08 Locking Handle Pin Length Door Stile LH-725 P = 6 mm 46mm LH-70 P = 9 mm 49mm LH-740 P = 14 mm 54mm LH-745 P = 27 mm 67mm