NEW! XL2 EXELLINE HANDHELD AUDIO AND ACOUSTIC ANALYZER LESS NOISE. MORE SOUND. Sound Level Meter. Real Time Analyzer. FFT Analyzer.

Similar documents
NEW! XL2 EXELLINE HANDHELD AUDIO AND ACOUSTIC ANALYZER LESS NOISE. MORE SOUND. Sound Level Meter. Real Time Analyzer. FFT Analyzer.

FLEXUS fx100 AU D I O A N A LY Z E R AUDIO TEST & MEASUREMENT SOLUTIONS. Analog & Digital Audio. Fast Measurements.

21. Technical Data XL2

OPERATING MANUAL HANDHELD AUDIO AND ACOUSTIC ANALYZER

Technical Data Measurement Microphones

Minirators MR-PRO / MR2

OPERATING MANUAL. Measurement Microphones

What you Need: Exel Acoustic Set with XL2 Analyzer M4260 Measurement Microphone Minirator MR-PRO

How To... Commission an Installed Sound Environment

OPERATING MANUAL. Measurement Microphones

Microphone Test System

Dodecahedron Speaker Set

Audio & Acoustic. Test & Measurement Solutions. Switzerland

Airborne Sound Insulation

Design and Production. Analog & Digital Audio. Fast & Accurate Measurements. Scalable Architecture. Superior Specifications.

SpeechLine Digital Wireless SL Lavalier Set

CLIO Pocket is Audiomatica's new Electro-Acoustical Multi-Platform Personal measurement system.

SpeechLine Digital Wireless SL Headmic Set

SL Handheld Set. Product specification FEATURES SPECIFICATIONS DELIVERY INCLUDES

SL Lavalier Set. Product specification FEATURES SPECIFICATIONS DELIVERY INCLUDES

NTI Minirator MR-PRO Mike Rivers

SL TS 133 GN Set DW FEATURES

SpeechLine Digital Wireless SL TS 133 GN Set DW

SpeechLine Digital Wireless SL TS 153 GN-L Set DW

SL Headmic Set. Product specification FEATURES SPECIFICATIONS DELIVERY INCLUDES

SL TS 153 GN-L Set DW

evolution wireless G4 ew 300 G4-HEADMIC1-RC Bodypack Headmic Set

evolution wireless G4 ew 500-G4-MKE 2 Lavalier Set

evolution wireless G4 ew 300 G4-865-S Handheld Set

TA-80. Digital Plug-on Transmitter

SP395 SoundPro Audio Integrator Operation Manual (Firmware version 1.32)

PPA 377. Personal PA FM Listening System FM SPECIFICATION DATA. System Includes:

Minilyzer ML1 User Manual

evolution wireless G4 ew 112 P G4 Camera Lavalier ME 2 Set ew 122 P G4 Camera Lavalier ME 4 Set

Microphones & Accessories

evolution wireless G4 ew 135 P G4 Camera Handheld Set

evolution wireless G4 ew 500 FILM G4 Pro Camera Lavalier MKE 2 +

evolution wireless G4 ew 100 G4-ME2 ew 100 G4-ME4 Lavalier Set

evolution wireless G4 ew 100 ENG G4 Camera Lavalier + Plug-on Transmitter Set

NoiseMeters. The Practical & Easy To Use Solution for Industrial & Environmental Noise Measurements.

evolution wireless G4 ew 500-G4-935 ew 500-G4-945 ew 500-G4-965 Vocal Set

CEL63x Sound Level Meter CEL630, CEL631, CEL632, CEL633 Class 1 or Class 2. Integrating. Advanced Logging. Audio Recording

SpeechLine Digital Wireless SL Boundary Set DW

evolution wireless G4 ew 100 G4-835-S ew 100 G4-845-S ew 100 G4-865-S Vocal Set

evolution wireless G4 ew 512 P G4 Pro Camera Lavalier MKE 2 Set

Minilyzer ML1 User Manual

Bosch Communications Systems Get your message across, effectively.

MP-1 Microphone Preamplifier User Guide and Technical Information

C1.1 Specification of the SVAN 971 as SLM in the standard configuration

RT-2M Audio Analyzer Measure what you hear...and beyond

DEDICATED TO SPEECH. Experience Simplicity with SpeechLine Digital Wireless

Production Analyzer Rev (USB + FireWire) Rev. 2.x (USB only)

Manufacturer Calibration Certificate

SHURE INCORPORATED KSM109 CARDIOID CONDENSER MICROPHONE. Thank you for selecting the KSM109

evolution wireless G4 ew 300 G4-Base SK-RC Bodypack Base Set

Product Information TLM 127. Large Diaphragm Microphone

Speech Intelligibility

Universal audio/midi interface USER MANUAL

DMS 700 Digital Microphone System

Real time spectrum analyser sound level meters

Exposure Level Tester ELT-400

SW Series Impedance Tube Solutions

Impulse response. Frequency response

Dante Kit MEG basic

User Guide. 2003, Shure Incorporated 27B3138 (CD) Printed in U.S.A.

NTI Minilyzer Mike Rivers

WMS 450 Wireless Microphone System

Trademark Notices: Patent Notice:

User Guide. Version 1.0.

evolution wireless G4 ew 500 BOOM G4 Pro Camera Plug-on Transmitter set

User Guide. Version 1.0 POWER

Dante Kit MEB 114-S. Thanks to its rugged housing and its high-quality microphone capsule the MEB 114-S ensures the best speech intelligibility.

DIGITAL WIRELESS. Transparent 24-bit digital audio captures every performance detail. Incredibly Efficient Wireless. Powerful Networking Features

User Guide FFFA

Dante Kit MEG FEATURES DELIVERY INCLUDES PRODUCT VARIANTS

Speech Intelligibility

Making Your Tour. State of the Art. TourGuide 2020-D

MAGNETIC FIELD METER Operator s Manual

EM 6000 EM 6000 DANTE True bit diversity receiver

IMPORTANT SAFETY INSTRUCTIONS

Audio Analyzers UP 300/UP 350

Appendix G - Specifications. G Specifications. Appendix G - Specifications ANALOG SIGNAL OUTPUTS. Low Distortion Sine Wave. Frequency Accuracy

Appendix D - Specifications. D Specifications. Appendix D - Specifications ANALOG SIGNAL OUTPUTS. Low Distortion Sine Wave

System Two Cascade Plus Audio Test and Measurement System

DMS-7AS DRUM MICROPHONE SET 7 MICROPHONES, 12 PIECE FEATURES CONTENTS

A Guide to Environmental Noise Measurement Terminology

Audio Analyzer R&S UPV. Up to the limits

SPL3220. Stereo Multiband Sound Processor / Loudness Maximizer / Limiter. Features

User Guide FFFA

Agilent U2000 Series USB Power Sensors. Data Sheet

LBC 3201/00 Line Array Indoor Loudspeaker

BM-500 Professional studio recording microphone

100 dbv to dbv (10 μv to V) for 600 Ω 24 dbu 100 dbv to dbv (10 μv to 6.22 V)

User Guide FFFA

datasheet TQ-315 QLIGHT SERIES ENGINEERING INFORMATION FEATURES APPLICATIONS CEW technology Trapezoidal cabinet Rotatable HF waveguide

Transparent 24-bit digital audio captures every performance detail. Incredibly Efficient Wireless. Powerful Networking Features

ODEON APPLICATION NOTE Calculation of Speech Transmission Index in rooms

n CLIO 12, by Audiomatica, is the newest measurement software for the CLIO System. The CLIO System is capable of measuring: n electrical networks n

SpeechLine Wired MEB 102 (-L), MEB 104 (-L) Install Boundary Layer Microphone

SC160. Integrating Sound Level Meter Real time frequency Analyser* in Octave Band

Transcription:

LESS NOISE. MORE SOUND NEW! Sound Level Meter Real Time Analyzer FFT Analyzer STI-PA Analyzer XL2 HANDHELD AUDIO AND ACOUSTIC ANALYZER Audio Analyzer EXELLINE Made in Switzerland www.nti-audio.com

Introduction FLEXIBLE USER INTERFACE The XL2 analyzer forms the unique combination of a stateof-the-art Sound Level Meter, a comprehensive Acoustical Analyzer as well as a powerful Audio Analyzer. The wide range of functionalities are tailored for challenging applications in Installations, Live Sound, Studio, Broadcast and Environmental Noise measurements. The measurement microphones M4260 (Class 2) and M2210 (Class 1 frequency response) are available for acoustical measurements. The XL2 generates the 48 V phantom power supply for the microphones and reads the included electronic data sheet of the M4260 and M2210 automatically. This promotes faster setup and ensures accurate measurements. Additionally the XL2 logs the calibration data and microphone serial number at each measurement. A remarkable advantage of the XL2 is the flexible user interface. The measurement screens may be personalized and only a limited subset of the comprehensive functionalities enabled for simplified operator interfaces. Advanced users may access all menus, settings and store their preferred measurement configurations. For basic users offers the XL2 Audio and Acoustic Analyzer fixed operator interfaces with specific pre-defined settings. The XL2 boots up with exactly the required measurement parameters according the predefined instrument configurations. This ensures accurate measurements achieved by advanced and basic users. The four fast access buttons together with the rotary wheel enable an intuitive instrument operation for precise measurements. The recorded measurement data can be transferred to PC either by the USB interface or directly from the Mini-SD card for later documentation. 02

FUNCTIONS Sound Level Meter The XL2 provides together with the measurement microphone a precise sound level meter for monitoring of live sound events, environmental noise. For example Actual, Lmin, Lmax, Leq, LCpeak are measured with frequency weighting A, C, Z and time weightings F and S at the same time. All measurement results are simultaneously available. Customers may log all acquired level information onto a removable Mini-SD card including real time information. Additionally the XL2 offers wave file recording for a complete documentation of the measured sound pressure levels, as well voice notes might be added for each measurement. The accuracy of the XL2 exceeds IEC 61672-1, class 1. The XL2 measures correction values between the loudest point of the live event and the actual measurement positions according DIN 15905-5 and SLV 2007. The measured signal can be monitored acoustically at the internal speaker, e.g. at applications with the microphone positioned in another room. Real Time Analyzer In addition to the wide band parameters the XL2 measures in parallel the real time spectrum either in 1/1 or 1/3 octave-band resolution. The RTA perfectly suits tasks, such as optimizing of sound systems. FFT Analyzer The real-time FFT is the ideal tool for visualization of comb filters and narrow band effects. It measures the actual level and the averaged level Leq in three ranges over the entire audio band. Extended Acoustic Pack (optional) The Extended Acoustic Pack offers additional features for sound level- and acoustical measurements. These are statistical distribution as Percentiles, TaktMax, Sound exposure level, impulse time weighting and high resolution FFT. RT60 Reverberation Time The XL2 measures the energy decay in from 63 Hz to 8 khz by the Schroeder method. As test signal serves either an impulse source or gated pink noise. Delay Time The delay function suits the accurate setup of delay line arrangements, thus the directionality of the signal source will be optimized. The XL2 measures the delay time between the electrical reference signal and the acoustical signal from the speaker. The required acoustical delay settings are displayed automatically, thus the audio engineer may set the measured delay time directly at the delay device in the rack. Speech Intelligibility STI-PA (optional) The STI-PA function measures the speech intelligibility of public announcement systems according the latest revision of IEC 60268-16:2003 standard. The XL2 displays the measurement results as STI or as CIS results, accompanied by the individual levels and modulation indices of the seven octave bands. The measurement results are acquired from the NTi Audio STI-PA test signal, generated by the included STI-PA Test CD, Minirator MR-PRO or the NTi Audio TalkBox. Audio Analyzer Together with the balanced XLR and unbalanced RCA inputs includes the XL2 a comprehensive audio analyzer. It measures simultaneously level, distortion (THD+N) and frequency. The internal loudspeaker or headphone output offers audible monitoring of the test signal or just listening to the residual distortion. The optimized low distortion and low noise design enable level measurements down to -112 dbu and residual distortions typically lower than -100 db, which is unmatched in handheld instruments. 03

LIVE SOUND SOLUTIONS SPL,Leq RTA Logging Wav-File Polarity Delay The XL2 Audio and Acoustic Analyzer offers all tools to optimize the performance of live sound systems within one instrument. It complies with the most recent international standards for environmental noise monitoring. The acoustic analyzer XL2 fulfills class 1 requirements throughout the hardware and algorithms. The broad list of functions compels: Sound level meter displays up to five levels simultaneously Visual limit indication at exceeding sound levels Real time analyzer in 1/3 octave or 1/1 octave resolution Logging of all measurements to the internal Mini-SD Card Simplified operation using application profiles Correction value measurement wizard Built-in real time clock WAV-file recording to Mini-SD Card 04

INSTALLED SOUND, STUDIO BROADCAST SOLUTIONS XL2 s broad range of functionalities provides contractors and audio engineers a comprehensive set of diagnostic and measurements tools. The instruments is perfectly tailored for installing, commissioning and troubleshooting sound- and audio systems in studios, broadcast and fixed installations. The feature list includes: Analyzer for acoustic and electrical audio measurements Balanced signal input from -112 dbu (2µV) up to 30 dbu (25 V) with residual distortions of typically < -100 db (0.001%) High-resolution FFT for narrowband analysis, 5 Hz to 20 khz Reverberation time with impulse source or gated pink noise Delay and polarity measurements Built-in loudspeaker with automatic gain control Speech intelligibility STI-PA acc. to IEC 60268-16 (optional) SPL,Leq RTA FFT RT60 Delay Level THD+N STI-PA 05

MEASUREMENT MICROPHONES The plug-on measurement microphones M4260 (class 2) and M2210 (class 1 frequency response) form with the XL2 a comprehensive sound level meter and acoustic analyzer. The microphones include an electronic data sheet. Thus the automated sensor detection of the XL2 recognizes the sensitivity and calibration data of the connected microphone automatically. M4260 Measurement Microphone M2210 - Enhanced Performance Measurement Microphone Microphone Type Capsule / Transducer 1/4 permanently installed capsule Flatness M4260 M2210 - Enhanced Performance Omni-directional, pre-polarized condenser, free field microphone Class 2 (IEC61672-1) < ±1.4 db @ 100 Hz - 1250 Hz < ±3.5 db @ 20 Hz - 20 khz 1/2 detachable capsule with 60UNS2 thread Class 1 (IEC61672-1) < ±1.1 db @ 100 Hz - 4 khz < ±2.5 db @ 10 Hz - 20 khz Frequency Range 20 Hz - 20 khz 1 Hz - 20 khz Residual Noise Floor typ. 27 db(a) 18 db(a) Maximum SPL @ THD 3%, 1 khz Sensitivity typical 136 db 145 db -30 dbv/pa ±4 db (30 mv/pa) @ 1kHz -34 dbv/pa ±3 db (20 mv/pa) @ 1kHz Temperature coefficient 0.05 db / C @ +10 to +50 C 0.01 db / C @ -10 to +50 C Electronic Data Sheet NTi Audio ASD according IEEE P1451.4 V1.0, Class 2, Template 27 Output Impedance Power Supply 100 Ohm balanced 48 VDC phantom power, 3 ma typical Dimensions Lenght 150 mm (5.9 ), diameter 20.5 mm (0.8 ) Connector Balanced 3-pole XLR ACCESSORIES ORDER INFORMATIONEN Battery Charger with Spare Battery Exel System Case delivery without content Product NTi Audio # XL2 + M4260 600 000 340 XL2 + M2210 - Enhanced Performance 600 000 350 XL2 without Measurement Microphone 600 000 330 M4260 Measurement Microphone, Class 2 600 040 025 M2210 Measurement Microphone, Class 1 Frequency Response 600 040 020 Calibration Certificate for XL2, M4260 or M2210 600 000 018 Ever-ready Pouch 06 Mains Power Adapter ASD Cable (special audio cable for the transmission of the electronic data sheet from measurement microphone to the XL2, length = 5 metre) 600 000 336 Battery Charger with Spare Battery 600 000 332 Spare Battery 600 000 337 Mains Power Adapter 600 000 333 Ever-ready Pouch 600 000 335 Exel System Case 600 000 334 XL2 STI-PA Option 600 000 338 Extended Acoustic Pack 600 000 339

TECHNICAL SPECIFICATIONS XL2 Sound Level Meter Product XL2 with M2210 microphone: Class 1 freq. response acc. to IEC 61672 Configurations XL2 with M4260 microphone: Class 2 acc. to IEC 61672 Conforms with Standards Measurements Functions Extended Acoustic Pack (optional) Weighting Linear Measurement Range Real Time Analyzer RTA IEC 61672, IEC 60651, IEC 60804, ANSI S1.4, ANSI S1.43, DIN 15905-5, DIN 45645-1*, DIN 45645-2, SLV 2007 SPL actual, Leq, Lmin, Lmax, LCpeak Gliding LAeq with t = 5, 60 and 60 All measurement results are simultaneously available Level Resolution: 0.1 db Logging all data or subsets in selectable intervals Correction value measurement wizard Recording of WAV-files (ADPCM) and voice notes Percentiles: 1%, 5%, 10%, 50%, 90%, 95%, 99% Time Weighting: Impulse Sound Pressure Level LIeq, Sound Exposure Level L AE TaktMax and values as specified in DIN 45645-1 High-resolution FFT with selectable frequency ranges and resolution up to 0.4 Hz in the range of 5 Hz - 20 khz Frequency Weighting: A, C, Z Time Weighting: Fast, Slow, Impulse* Overall linear measurement range 3 µv - 25 VRMS parted in 3 overlapping ranges based on the preset sensitivity, e.g. Sensitivity = 50 mv/pa -> overall measurement range = 0-140 db Sensitivity = 20 mv/pa -> overall measurement range = 10-150 db Internal noise: 1.3 µv A-Weighted Frequency Resolution: 1/3 octave, 1/1 octave, wide band Frequency Range: 6.3 Hz to 20 khz, level resolution: 0.1 db Band pass filters conform IEC 61260 class 0, ANSI S1.11-2004, class 1 Acoustic Analyzer FFT Analysis Real time FFT with LZF and Leq, level resolution 0.1 db Ranges: 7 Hz - 215 Hz, 58 Hz - 1.72 khz, 484 Hz - 20.5 khz High-resolution FFT with selectable frequency ranges and resolution up to 0.4 Hz in the range of 5 Hz - 20 khz* Reverberation 1/1 octave bands results from 63 Hz - 8 khz, based on T20 Time RT60 1/3 octave bands results by post processing Range: 10 ms - 14 seconds Measurement according to ISO3382 by Schroeder-method Test signal: Impulse source or gated pink noise generated by the MR-PRO, MR2 or the included NTi Audio Test CD Delay Time Polarity STI-PA Speech Intelligibility (optional) Propagation delay between electrical reference signal and acoustical signal using the internal microphone Range: 0 ms - 1 second (0 m - 344 m), Resolution: 0.1 ms Test signal: NTi Audio delay test signal generated by the MR-PRO, MR2 or the included NTi Audio Test CD Checks polarity of speakers and line signals Positive/Negative detection of wideband and individual 1/1 octave bands through internal microphone or XLR/RCA connector Test signal: NTi Audio polarity test signal generated by the MR-PRO, MR2 or the included NTi Audio Test CD Single value STI and CIS test result according to IEC 60268-16, 2003 release, DIN VDE 0833-4, IEC 60849, DIN VDE 0828-1 Modulation indices and individual band level results with error indicator, post processing with recorded spectra supported Test signal: NTi Audio STI-PA signal generated by the MR-PRO, NTi Audio TalkBox or the STI-PA Test CD Audio Analyzer Level RMS Frequency THD+N (Total Harmonic Distortion + Noise) Filter True RMS detection in V, dbu and dbv Range XLR/RCA input: 2 µv - 25 V (-112 dbu to +30 dbu) Accuracy: ± 0.5 % @ 1 khz Flatness: ± 0.1 db Bandwidth: 20 Hz to 20 khz Resolution: 3 digits (db scale),5 digits (linear scale) or 6 digits (x1 scale) Range: 9 Hz to 20 khz Resolution: 6 digits Accuracy: < ± 0.003% Range: -100 db to 0 db (0.001% to 100%) Minimum level: > -90 dbu Bandwidth: 10 Hz to 20 khz Resolution: 3 digits (db scale) or 4 digits (linear scale) Residual THD+N @ XLR/RCA input: < 2 µv Frequency weighting: A, C, Z, Highpass 400 Hz, Highpass 19 khz Input / Output Interfaces Audio Inputs XLR balanced with input impedance = 200 kohm, phantom power: +48 V switchable, automated sensor detection for M4260/M2210 RCA unbalanced with input impedance >30 kohm Built-in condenser microphone for polarity testing, delay measurements and voice note recording Audio Outputs USB Interface Digital I/O TOSLink Memory Power Supply General Clock Calibration Mechanics Temperature Humidity Electromagnetic Compatibility Built-in speaker Headphone connector 3.5 mm Minijack Stereo USB mini connector for data transfer to PC and charging of Li-Po battery Serial I/O interface, programmable (prepared for later firmware extension) 24 bit linear PCM audio signal output (prepared for later firmware extension) Mini-SD card, 2 GByte, removable, storing ASCII data, screenshots, voice notes and WAV-files Rechargeable Li-Po battery included, type 3.7 V / 2260 mah, typical battery lifetime > 4 hours Dry cell batteries type AA, 4 x 1.5 V, typical battery lifetime > 4 hours Linear external power supply 9 VDC (charges Li-Po battery in operation) Real time clock with lithium backup battery Recommended calibration interval: one year Microphone calibration supported with external calibrator Calibration certificate for new instruments optional available Tripod mount and wire stand mounted on rear side Display: 160 x 160 pixels grey scale with LED back light Dimensions: 180 mm x 90 mm x 45 mm (7.1 x 3.5 x 1.8 ) Weight: 480 g (1 lbs) including built-in Li-Po battery Operation: +5 C to +45 C (41-113 F) Storage: -10 C to +60 C (14-140 F) 5% to 90% RH, non condensing CE compliant: EN 61326-1 Class B, EN 55011 class B, EN 61000-4-2 to -6 & -11 * optional 07

LESS NOISE. MORE SOUND NTi Audio WORLDWIDE NTi Audio AG Im alten Riet 102 9494 Schaan Liechtenstein / Europe Phone: +423 239 60 60 Fax: +423 239 60 89 info@nti-audio.com NTI Americas P.O. Box 231027 Tigard, Oregon 97281, United States Phone: +1 503 684 7050 Fax: +1 503 684 7051 americas@nti-audio.com NTI China Room 722, 7F, Building 6-3A, No 1388, Bin He Rd. 215000 Suzhou Phone: +86 512 6802 0075 Fax: +86 512 6802 0097 china@nti-audio.com NTI Japan Ryogokusakamoto Bldg.1-8-4 Ryogoku 130-0026 Sumida-ku Tokyo, Japan Phone: +81 3-3634-6110 Fax: +81 3-3634-6160 japan@nti-audio.com All information are subject to change without notice. Exel, XL2, M4260, M2210, Minirator MR-PRO, MR2 and TalkBox are trademarks of NTi Audio. Made in Switzerland www.nti-audio.com dth 10000-11.09