Model P2000 onfigurable Pressure Transducer SIPTION The P2000 series is a configurable pressure transducer which allows the customer to select the configuration which best fits the needs of the application. hoose from multiple accuracies, outputs, pressure ports, electrical terminations, and pressure ranges. The P2000 is available with gage, absolute, barometric, vacuum reference, or differential (wet/wet, wet/dry) and, best of all, they deliver in two weeks or less. pproved pproved TUS mv/v, 0 Vdc to, 0 Vdc to, 4 m to age, absolute, barometric, vacuum ifferential (wet/wet, wet/dry) Intrinsically safe option 5 available 6 P2000 pressure sensors are custom built from stocked components, and most are shipped in 10 business days or less. Please see http://measurementsensors.honeywell.com for updated listings
Model P2000 POMN SPIITIONS haracteristic ccuracy 1 Output (selectable) esolution Measure See accuracy table mv/v (see accuracy table), 0 Vdc to, 0 Vdc to, or 4 m to (two wire) Infinite LTIL SPIITIONS haracteristic xcitation (calibration) mplified (4 m to ; 0 Vdc to ) mplified (0 Vdc to ) Unamplified (mv/v) Measure 9 Vdc to 28 Vdc 1 to 28 Vdc MHNIL SPIITIONS haracteristic Media Overload - safe (positive direction) Model & Model P, P, P, PV 1000 psi and below 1500 psi and above Overload - safe (negative direction) Model & Overload - burst (positive direction) Model & Model P, P, P, PV Measure as, liquid 4X full scale or 3000 psi, whichever is less 4X full scale or 3000 psi, whichever is less 4X full scale or 15000 psi, whichever is less 4X full scale or 250 psi, whichever is less 3000 psi 1000 psi and below 3000 psi 1500 psi and above 15000 psi Overload - burst (negative direction) Model & Pressure port etted parts material 500 psi 200 % over capacity Ha 276 & 316L stainless steel TYPIL SYSTM IM daptors compatible with: 1/4-18 NPT male 1/4-18 NPT female 7/16-20 UN male 7/16-20 UN female 1/4 male 1/4 female 6q 6r 6a 6n Model P2000 6m Mating connectors & cables PT06-10-6S (option 6a) mv/v - 4 conductor cable 4 m to - 3 conductor cable 0-5/ 0- - 3 conductor cable Standard IN 43650 (option 6m) Mini IN 40050 (option 6n) In-line amplifiers (Used with unamplified units only) mplifier Output Universal in-line amplifiers U2 4 m to (2-wire) isplay units S500 S2000 S2001 S3004 M (unamp. only) M- (amp. only) NK (unamp. only) HH (unamp. only) ustomer supplied hart recorder larm panel ata acquisition omputer PL 2 Honeywell Sensing and ontrol
NVIONMNTL SPIITIONS Order ange Temperature, ompensated P PV P 26 in-hg to 32 in-hg 16 in-hg to 32 in-hg 10 to 45 [50 to 110 ] 30 in-hg 5 to 60 [40 to 140 ] less than 1 psi 10 to 45 [50 to 110 ] 1 psi and less than 5 psi 5 to 50 [40 to 120 ] 5 psi and above 5 to 60 [40 to 140 ] less than 1 psi 10 to 45 [50 to 110 ] 1 psi and less than 5 psi 5 to 50 [40 to 120 ] 5 psi and above 5 to 60 [40 to 140 ] P 5 psi and above 5 to 60 [40 to 140 ] Temperature, error band less than 1 psi 10 to 45 [50 to 110 ] 1 psi and less than 5 psi 5 to 50 [40 to 120 ] 5 psi and above 5 to 60 [40 to 140 ] less than 1 psi 10 to 45 [50 to 110 ] 1 psi and less than 5 psi 5 to 50 [40 to 120 ] 5 psi and above 5 to 60 [40 to 140 ] onfigurable Pressure Transducer Temperature, Operating Unamplified Output: Option 2U -40 to 116 [-40 to 240 ] 0.10 % accuracy ±0.5 % full scale 0.25 % accuracy ±1.0 % full scale Temperature, Operating Voltage Output: Option 2,2,2,2 urrent Output: Option 2P,2Y,2N -29 to 85 [-20 to 185 ] Honeywell Sensing and ontrol 3
Model P2000 PSSU NS N N OS psi ange torr ange mar ange kpa ange ar ange in Hg ange mm Hg ange in H 2 O ange age/ bsolute 0.5* N 1* P 2* 2.5* S 5 T 10 V 15 J 25 L 30 M 50 N 75 P 100 150 J 200 L 250 N 300 P 400 Q 500 600 S 750 T 1000 V 1500 J 2000 L 2500 M 3000 N 5000 6000 S 7500 T 10000 V 15** H 50** H 135** H 250 H 750 H 1500 H 35** J 70** J 175** J 350 J 700 J 750 J 1000 J 3500 JH 7000 JI 10000 JK 2** K 7** K 15** K 35 K 70 K 100 K 200 K 300 KH 700 KJ 1000 KL 1500 KM 1700 KN 2000 KP 3000 KQ 5000 K 7000 KS 10000 KT 15000 KU 20000 KV 35000 K 50000 KY 70000 KZ 0.035** M 0.1** M 0.2 M 0.5 M 1 M 2 M 3.5 N 5 M 7 N 10 MH 20 MI 30 MJ 35 N 50 MK 70 N 100 ML 135 N 350 N 500 MM 700 NH 1** U 2** U 5 U 10 U 15 U 20 U 30 U 50 UI 60 UK 80 UM 100 UP 200 UH 300 UJ 500 UL 1000 UN 0-32 US 16-32 UQ 26-32 U 15** V 50** V 135 V 250 V 750 V 1500 V 5** 10** 20** 30** 50** 100 I 120 K 150 M 200 P 300 500 S arometric (Order P) 0-30 U 16-32 UQ 26-32 U Vacuum (Order PV) 1 P 5 T 10 V 15 J 50 H 135 H 250 H 750 H 35 J 70 J 175 J 350 J 700 J 750 J 1000 J 7 K 15 K 35 K 100 K 0.035 M 0.1 M 0.2 M 0.5 M 1 M 10 U 20 U 30 U 15 V 50 V 135 V 250 V 750 V 10 20 30 50 100 I ifferential (Order s, ) 0.5 N 1 P 2 2.5 S 5 T 10 V 15 J 25 L 30 M 50 N 75 P 100 150 J 200 L 250 N 300 P 400 Q 500 600 S 750 T 1000 V 15 H 50 H 135 H 250 H 750 H 1500 H 35 J 70 J 175 J 350 J 700 J 750 J 1000 J 3500 JH 7000 JI 10000 JK 2 K 7 K 15 K 35 K 70 K 100 K 200 K 300 KH 700 KJ 1000 KL 1500 KM 1700 KN 2000 KP 3000 KQ 5000 K 7000 KS 10000 KT 15000 KU 20000 KV 35000 K 50000 KY 0.035 M 0.1 M 0.2 M 0.5 M 1 M 2 M 3.5 N 5 M 7 N 10 MH 20 MI 30 MJ 35 N 50 MK 70 N 1 U 2 U 5 U 10 U 15 U 20 U 30 U 50 UI 60 UK 80 UM 100 UP 200 UH 300 UJ 500 UL 1000 UN 0-32 US 16-32 UQ 26-32 U 15 V 50 V 135 V 250 V 750 V 1500 V 5 10 20 30 50 100 I 120 K 150 M 200 P 300 500 S * 0.5 psi to 2.5 psi ranges are not available for absolute pressure ** Not available in absolute 4 Honeywell Sensing and ontrol
INTNL MPLIIS mplifier specifications Unamplified output: Option 2u Option 2d onfigurable Pressure Transducer Option 2g urrent two-wire: Option 2p Output signal See accuracy table 0 Vdc to 0 Vdc to 4 m to Input power (voltage) 9 Vdc to 28 Vdc 1 to 28 Vdc 9 Vdc to 32 Vdc Input power (current) 2 m @ 10 m 15 m 4 m to 24 m requency response Natural frequency 300 Hz 300 Hz 300 Hz Power supply rejection N/ 60 d 60 d 60 d Operating temperature -40 to 116 [-40 to 240 ] -29 to 85 [-20 to 185 ] -29 to 85 [-20 to 185 ] everse voltage protection N/ Yes Yes Yes Short circuit protection N/ Momentary Momentary Yes -29 to 85 [-20 to 185 ] mplifier specifications Option 2e Option 2f Intrinsically safe amp: Option 2n (2N)*** urrent two-wire: Option 2y Output signal 0 Vdc to 0 Vdc to 4 m to 4 m to Input power (voltage) 9 Vdc to 28 Vdc 1 to 28 Vdc 9 Vdc to 28 Vdc 9 Vdc to 32 Vdc Input power (current) 10 m 15 m 4 m to 24 m 4 m to 24 m requency response 2000 Hz 2000 Hz 2000 Hz 2000 Hz Power supply rejection 60 d 60 d 60 d 60 d Operating temperature -29 to 85 [-20 to 185 ] -29 to 85 [-20 to 185 ]` -29 to 85 [-20 to 185 ] everse voltage protection Yes Yes Yes Yes Short circuit protection Momentary Momentary Yes Yes -29 to 85 [-20 to 185 ] UY Non-amplifed output @ excitation age and absolute Vacuum arometric ifferential 0.10 % accuracy 50 mv 4 25 mv 40 mv 50 mv 4 0.25 % accuracy 100 mv 50 mv 80 mv 100 mv Honeywell Sensing and ontrol 5
Model P2000 MOUNTIN IMNSIONS lectrical termination ode 6a: 6-pin, vented, endix style ode 6m: 4-pin, vented, standard IN (43650) ode 6n: 4-pin, vented, mini IN ode 6q: 4-conductor, vented, integral cable, 1,52 m [5 ft] ode 6r: 4-conductor, vented, integral cable, conduit fitting 1,52 m [5 ft] P, P, P, PV Pressure ports ode 5a 1/4-18 NPT female ode 5b 1/4-18 NPT male ode 5c 7/16-20 UN female ode 5d 7/16-20 UN male ode 5f 1/4 female ode 5g 1/4 male Less than 1000 psi reater than 1500 psi ode 5h 1/8-27 NPT female ode 5i 1/8-27 NPT male ode 5p M12-1.5 male ode 5q M12-1.5 female ode 5r 9/16-18 S male ode 5s 9/16-18 S female Less than 1000 psi reater than 1500 psi 6 Honeywell Sensing and ontrol
onfigurable Pressure Transducer IIN OS Unamplified output: Option 2u endix PTIH-10-6P (Option 6a) Option 2d/2e Option 2g/2f urrent two-wire: Option 2p/2y Intrinsically safe amp: Option 2n (2N)*** No shunt cal (+) xcitation (+) xcitation (-) xcitation (-) xcitation (+) Output 0 Vdc to (+) Output 0 Vdc to (+) Output Vdc ase ground ith shunt (+) xcitation (-) xcitation (+) Output Shunt al 0 Vdc to (+) Output 0 Vdc to (+) Output Std. IN 43650 (Option 6m) No shunt cal 1 (+) xcitation 3 4 (-) xcitation 1 3 Supply/ output com. N No connect. to case 1 3 Supply/ output com. N No connect. to case 1 4 m to 3 N 1 3 ase ground N ith shunt Not pplicable 1 N 1 N 1 4 m to 3 N 1 3 ase ground N Mini IN 40050 (Option 6n) No shunt cal 1 (+) xcitation 3 4 (-) xcitation 1 N No connect. to case 1 N No connect. to case 1 4 m to 3 N to case 1 3 ase ground N ith shunt Not pplicable 1 N 1 N 1 4 m to 3 N 1 3 ase ground N 1.83 m [5 ft] integral cable (Option 6q) No shunt cal (+) xcitation (-) xcitation (+) Output ase ground ith shunt Not pplicable ase ground onduit fitting (Option 6r) No shunt cal (+) xcitation (-) xcitation (+) Output ase ground ith shunt Not pplicable ase ground Note: or wiring s, =red; = black; = white; = green. olor specifies cable and letter or number specifies connection *** See Honeywell s eb site for most up-to-date information regarding Intrinsically Safe approvals ref. #008-0547-00. Honeywell Sensing and ontrol 7
Model P2000 How to order The P2000 Order ode is an easy way for you to order exactly what you want the factory to build. Simply make one selection in each of the six required categories. hoose adders and accessories only if you require them. y visiting our eb site at www.honeywell.com/sensing you can view complete technical specifications for the P2000, or click to our on-line shopping site and actually place your order. Step 1 Step 2 Step 3 Transducer type Type ode o Pressure - gage P o Pressure - absolute P o ifferential - wet/wet o Pressure - barometric P o ifferential - wet/dry o Pressure - vacuum PV Unit type o psi o bar o torr o in Hg o mar o mm Hg o kpa o in H 2 O Step 4 dders dder o nhanced thermals 1y age: 0 to 180 bsolute: 0 to 180 ifferential: 0 to 180 arometric: 30 to 170 Vacuum: 10 to 170 o 3d o IS rating 9d o rating 9e o IS and rating 9f o Zero and span adjustments 14c o mv/v 2u o 2e o 2f o 4 m to ( only) 2y o 4 m to (IS only 2n (2N) o 4 m to (IS and ) 2n (2N) NOT: If you choose any adder output from step 4, you must revise your output selection using this output chart. IS outputs available only on ranges up to 5000 psi. ccessories Mating connectors only cc. o Mini IN 161 o endix 111 Mating conn. with 15 ft. cable for endix connector (6) ithout ith shunt shunt ( o mv/v 113 513 o 4 m to 116 516 o 0 to 5/0 to 117 517 Pressure range age, absolute, and differential ange ange o 0.5 psi N o 250 psi N o 1 psi P o 300 psi P o 2 psi o 400 psi Q o 2.5 psi S o 500 psi o 5 psi T o 600 psi S o 10 psi V o 750 psi T o 15 psi J o 1000 psi V o 25 psi L o 1500 psi J o 30 psi M o 2000 psi L o 50 psi N o 2500 psi M o 75 psi P o 3000 psi N o 100 psi o 5000 psi o 150 psi J o 6000 psi S o 200 psi L o 7500 psi T o 10000 psi V arometric Vacuum o 16-32 in Hga UQ o 1 psi P o 26-32 in Hga U o 5 psi T o 0-30 in Hga U o 10 psi V o 15 psi J ccuracy ccuracy o 0.10 % 1 o 0.25 % 2 Step 5 xample order Output asic If adding If adding output 9d or 9f 1y, 3d, 9e (<5000 psi) or 14c o mv/v 2u N 2u o 2d N 2e o 2g N 2f o 4 m to 2p 2n(2N) 2y NOT: If any S are required, the output must be revised. See step 4. Pressure Port Port o 1/4-18 NPT female 5a o 1/4-18 NPT male 5b o 7/16-20 UN female 5c o 7/16-20 UN male 5d o 1/4 female 5f o 1/4 male 5g o 1/8-27 NPT female 5h o 1/8-27 NPT male 5i o M12 x 1.5 male 5p o M12 x 1.5 female 5q o 9/16-18 UN S male 5r o 9/16-18 UN S female 5s lectrical connector onnector o endix PTIH-10-6P 6a o IN 43650 6m o Mini IN (40050) 6n o Integral polyurethane 5 ft cable 6q o 1/2 x 14 NPT conduit 5 ft cable exit 6r 1 N 2y 5b 6a 1y 116 Selection escription ode Transducer type ifferential wet/wet ccuracy 0.10 % 1 Pressure range 250 psi N Output 4 m to 2y Pressure port 1/4-18 NPT male 5b lectrical output connections endix PTIH-10-6P 6a dders nhanced temperature range 1y ccessories Mating connector with cable 116 There must be a in each of the six basic boxes. If there are no adders or accessories chosen, leave the boxes blank. escription asic dder (see step 4) Type ccuracy ange Output Pressure lect. conn. xtended. IS/ rated Pots Order ccessory Zero and span adjustments are located on the side. See drawing for details. No zero and span adjustments are available on mv/v output option. 8 Honeywell Sensing and ontrol
Model P2000 onfigurable Pressure Transducer NOTS 1. ccuracies stated are expected for best-fit straight line for all errors, including linearity, hysteresis, and non-repeatability through zero. 2. or low pressure ranges, temperature effects may vary. 3. The wet/wet differential pressure transducer has two separate, welded Hastelloy diaphragms. In wet/dry unit, the wet port (high port) has all-welded stainless steel and Hastelloy construction. The dry port (low port) has no isolation diaphragm. 4. or low gage and differential pressure ranges at 0.10 % accuracy, non-amplified output @ excitation = 100 mv. 5. ange up to and include 5000 psi. 6. Not available with 6m. arranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. hile we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. or more information about Sensing and ontrol products, visit www.honeywell.com/sensing or call +1-815-235-6847 mail inquiries to info.sc@honeywell.com NIN PSONL INJUY O NOT US these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. ailure to comply with these instructions could result in death or serious injury. NIN MISUS O OUMNTTION The information presented in this catalogue is for reference only. O NOT US this document as product installation information. omplete installation, operation and maintenance information is provided in the instructions supplied with each product. ailure to comply with these instructions could result in death or serious injury. Sensing and ontrol Honeywell 1985 ouglas rive North olden Valley, MN 55422 US honeywell.com 008608-3-N IL50 LO June 2014 opyright 2014 Honeywell International Inc. ll rights reserved.