FieldLink MC at 20 x outer diameter Torsion

Similar documents
Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified

Continuous Flex Data Cable

SUBMERSIBLE PUMP CABLES

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...

DB EN valid from: Application SERVO LK SMS FX8PLUS SIGNAL

Lutze Inc. Flexible Control Cables USA Selection Guide V. 2.6

BUS cable. BUS cable. Cables for use in automation- and communication technique.

Servo Cable Selection

THE WORLD OF LAPP. Cables for power chains

TPE-INSULATED CABLES TPE-INSULATED CABLES. Products. TPE - Cables HEW-KABEL/CDT

Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3

CIR (Crush & Impact Resistant) VFD Power Cable

CUSTOM DESIGN COAXIAL CABLES BY SICAB

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable

Caledonian. Profibus L2 Indoor BUS CABLE. Application: Construction:

High Temperature Flexible Control Cable

INTRODUCTION PRODUCT LINES GREEN ENERGY. In drive technology, the trend is towards ever more complex

Selection table for flat & ribbon cables

Addison. Profibus SK Indoor + Outdoor BUS CABLE. Application: Construction:

High Temperature Flexible Control Cable OLFLEX

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09)

CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES

ABOUT US ABOUT US 1 CRANE CABLES

Extremely Oil-Resistant & Flexible Tray Cable with UL & CSA; Unshielded & Shielded. Complete the Installation. SKINTOP Strain Relief page 488

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV

EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE. 24 AWG (0,23mm 2 ), 7/32 (7x0,20mm), Insulation Thickness: 0.010" (0,25mm)

HARAX. Contents Technical characteristics circular connector with HARAX rapid termination 50.02

RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø

BUS 1010F ssa (INTERBUS Remote Bus, 2-wire) xed installation

MarineLine YOZp 0,6/1 kv

Table of contents. Phone: Fax:

Motor, Servo & Feedback Cables

ÖLFLEX HEAT. Cable Solutions for Extreme Temperature

Instrumentation Cables

14 AWG 2 AWG: 600 Volt

Photo: HELUKABEL. Motor, Servo & Feedback Cables D 1

Electrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a.

SAC-5P- 1,5-PUR/M12FS SH

Data sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations

EcoCable and EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.

EcoCable and EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.

Electric cables. Cranes

EcoCable and EcoFlex Cable. Smaller. Lighter. 100% Recyclable.

Installation Solutions. Cable assembly according to Siemens 6FX standard

Challenges to automation

Data sheet Connection line M12 jack straight - RJ45 plug straight 4-pole, D-coded 2.0 m

Cores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc.

GEXOL WORLD CLASS OIL & GAS CABLES

Install & Go Cat.8 S/FTP Trunk Cable Assembly Description

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable

Innovative Eldra Solar Cabling System SOLINQ total system for solar cabling Sustainability

SAC-3P- 5,0-PUR/M12FR SH

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable

TIGER BRAND MINING CABLES

ÖLFLEX FORTIS 55 Highly Flexible and Extremely Oil-Resistant Tray Cable; -40 C Flexible/-55 C Stationary

Installation Solutions. Cable assemblies according to SIEMENS 6FX standard

For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation.

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft

ÖLFLEX HEAT. Cable Solutions for Extreme Temperature

WIRE & CABLE. 99 Wire Low fire hazard wire and cable

TRAXLINE CABLES FOR MOTION

Industrial Data Solutions Industrial Ethernet Cables Category 5e DataTuff Twisted Pair Cables Heavy Duty Sunlight- and Oil-Resistant Jackets

Contents. Han Hv ES / Han Hv E Technical characteristics Han Hv ES Technical characteristics Han Hv E Han 3 Hv ES

Incandescent Lampholders: Edison Screw and Bayonet Cap

Data sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft

NETWORK CONNECTIVITY SYSTEMS

Wire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable. Features & Benefits

Detailed Specifications & Technical Data

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

Conductix-Wampfler Cables for Festoon Systems, Energy Guiding Chains & Others

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

Welding Cables Rubber Insulated

ÖLFLEX. Lift & Crane Cable LIFT & CRANE CABLE

Cables and connectors for demanding connectivity solutions. LOW LOSS RF COAX CABLES single screen 75 Ω double screen 75 Ω

Medium Voltage Power Cables

Caledonian. VG Series. Caledonian Navy Cables.

COPPER + LWL RAW CABLES

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS

Kerman & Kavian Cable Industries ( KCI )

VFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE

OLFLEX. Flexible Tray Cable MARYLAND METRICS. LAPP products are available from

Section 4. Multi-Conductor

MHR-2 Two Conductor Mini High Resolution S-Video Cable

Detailed Specifications & Technical Data

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking

Detailed Specifications & Technical Data

Communication, Control, and Industrial Cable

C400-UMUM-100. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

UNIRAIL D RS485 and BUS cables

Information technology. Generic cabling systems, General requirements

15 years of experience

Power Cables and their Application

Shielded Fire Alarm Cables

HYDROFIRM(T) EMV-FC S1BC4BF KTW/W270 Drinking Water Application, shielded version ENERGY. Exclusive Authorised UK Distributor

Multi-Paired Cable Product Finder

A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES

Transcription:

Power cable for permanent installation and flexible applications with low mechanical stress DIN VDE 0281 Part 1 / HD21.1S3 Conductor Stranded bare copper wire acc. to IEC 60228 Cl.5 and Cl. 6, insulation optional of Polyolefine and PVC, wire identification V/L2, U/L1/C/L+, W/L3/L-, GNYE Four wires twisted in layers with fillers in gaps Jacket Polyvinylchloride (PVC) orange acc. to RAL 2003 0.6 / 1 kv (DIN VDE), 1000 V (UL / CSA) 4 kv 50Hz AC (wires) Minimum bending radius allowed 5 x outer diameter (single), 20 x outer diameter (repeated) 2 m/s² (6.56 ft/s²) 30 m/min (98.43 ft/min) 100 000 at 20 x outer diameter ± 30 /m ( ± 9.15 /ft) 20 C to + 80 C ( 4 F to + 176 F) single, + 0 C to + 60 C (+ 32 F to + 140 F) repeated, Order number Dimensions Outer diameter LEC 003344 4 x 1.50 8.0 (0.31) LEC 003346 4 x 2.50 9.6 (0.38) LEC 003348 4 x 4.00 11.0 (0.43) LEC 003350 4 x 6.00 13.1 (0.52) LEC 003352 4 x 10.00 19.5 (0.77) LEC 003354 4 x 16.00 23.5 (0.93) LEC 003356 4 x 25.00 27.0 (1.06) LEC 003358 4 x 35.00 30.5 (1.20) LEC 003360 4 x 50.00 36.5 (1.44) 52 LEONI

Power cable for flexible installation with high mechanical stress high endurance trailing applicable DIN VDE 0282 Part 10 / HD 22.10 S1 halogen free acc. to IEC 60754 Conductor Stranded bare copper wire acc. to IEC 60228 Cl. 6, insulation of TPE and PP, wire identification V/L2, U/L1/C/L+, W/L3/D/L-, GNYE Four wires twisted in layers with fillers in gaps Jacket Thermoplastic Polyurethane (TPU) orange acc. to RAL 2003 0.6 / 1 kv (DIN VDE), 1000 V (UL / CSA) Minimum bending radius allowed 6 x outer diameter (single), 12 x outer diameter (repeated) 5 m/s² (16.40 ft/s²) 180 m/min (590.55 ft/min) 10.000.000 at 12 x outer diameter ± 30 /m ( ± 9.15 /ft) 50 C to + 80 C ( 58 F to + 176 F) single, 20 C to + 60 C ( 4 F to + 140 F) repeated, Order number Dimensions Outer diameter LEC 002106 4 x 1.50 10.0 (0.39) LEC 002109 4 x 2.50 11.7 (0.46) LEC 002112 4 x 4.00 12.8 (0.50) LEC 002116 4 x 6.00 15.0 (0.59) LEC 002119 4 x 10.00 18.5 (0.73) LEC 002121 4 x 16.00 22.0 (0.87) LEC 002450 4 x 25.00 25.5 (1.00) LEC 002452 4 x 35.00 29.5 (1.16) LEC 002454 4 x 50.00 33.5 (1.32) LEONI 53

Hybrid cable for permanent installation and flexible applications with low mechanical stress DIN VDE 0281 Part 1 / HD21.1S3 Conductor Stranded bare copper wire acc. to IEC 60228 Cl.5 and Cl. 6, insulation optional of Polyolefine, TPE and PVC, wire identification power: V/L2, U/L1/C/L+, W/L3/L-, GNYE, signal: black, white Signal wires: twisted to a pair, tape-wrapped foil, spinning of copper wires (covering 85 %); pair and four wires twisted in layer with fillers in gaps and central filler Jacket Polyvinylchloride (PVC) orange acc. to RAL 2003 0.6 / 1 kv for power and 24 V for signal (DIN VDE), 1000 V for power and signal (UL / CSA) Minimum bending radius allowed 5 x outer diameter (single), 20 x outer diameter (repeated) 2 m/s² (6.56 ft/s²) 30 m/min (98.43 ft/min) 100.000 at 20 x outer diameter ± 30 /m ( ± 9.15 /ft) 20 C to + 80 C ( 4 F to + 176 F) single, + 0 C to + 60 C (+ 32 F to + 140 F) repeated, 54 LEONI

Order number Dimensions Outer diameter LEHC 003363 4 x 1.00 + (2 x 0.50) 9.6 (0.38) LEHC 003364 4 x 1.00 + (2 x 0.75) 10.0 (0.39) LEC 003962 4 x 1.00 + (2 x 1.00) 10.2 (0.40) LEHC 003963 4 x 1.00 + (2 x 1.50) 10.5 (0.41) LEHC 003365 4 x 1.50 + (2 x 0.50) 10.0 (0.39) LEHC 003366 4 x 1.50 + (2 x 0.75) 10.3 (0.41) LEHC 003057 4 x 1.50 + (2 x 1.00) 10.4 (0.41) LEHC 003345 4 x 1.50 + (2 x 1.50) 10.5 (0.41) LEHC 003367 4 x 2.50 + (2 x 0.50) 11.5 (0,45) LEHC 003368 4 x 2.50 + (2 x 0.75) 11.8 (0.46) LEHC 003369 4 x 2.50 + (2 x 1.00) 12.0 (0.47) LEHC 003347 4 x 2.50 + (2 x 1.50) 12.0 (0.47) LEHC 003370 4 x 4.00 + (2 x 1.00) 13.4 (0.53) LEHC 003371 4 x 6.00 + (2 x 1.00) 15.3 (0.60) LEHC 003372 4 x 10.00 + (2 x 1.00) 20.8 (0.82) LEHC 003373 4 x 16.00 + (2 x 1.00) 24.0 (0.94) LEHC 003349 4 x 4.00 + (2 x 1.50) 13.5 (0.53) LEHC 003351 4 x 6.00 + (2 x 1.50) 15.6 (0.61) LEHC 003353 4 x 10.00 + (2 x 1.50) 21.0 (0.83) LEHC 003355 4 x 16.00 + (2 x 1.50) 24.1 (0.95) LEHC 003357 4 x 25.00 + (2 x 1.50) 28.5 (1.12) LEHC 003359 4 x 35.00 + (2 x 1.50) 31.5 (1.24) LEHC 003361 4 x 50.00 + (2 x 1.50) 36.5 (1.44) LEONI 55

Hybrid cable for flexible installation with high mechanical stress high endurance trailing applicable DIN VDE 0282 Part 10 / HD 22.10 S1 halogen free acc. to IEC 60754 Conductor Stranded bare copper wire acc. to IEC 60228 Cl. 6, insulation of TPE and PP, wire identification power: V/L2, U/L1/C/L+, W/L3/D/L-, GNYE, signal: black, white Signal wire: twisted to pair, tape-wrapped foil, spinning of tinned copper wires (covering 85 %); pair and four wires twisted in layer with fillers in gaps and central filler Jacket Thermoplastic Polyurethane (TPU) orange acc. to RAL 2003 0.6 / 1 kv for power and 24 V for signal (DIN VDE), 1000 V for power and signal (UL / CSA) Minimum bending radius allowed 6 x outer diameter (single), 12 x outer diameter (repeated) 5 m/s² (16.40 ft/s²) 180 m/min (590.55 ft/min) 10.000.000 at 12 x outer diameter ± 30 /m ( ± 9.15 /ft) 50 C to + 80 C (-58 F to +176 F) single, 20 C to + 60 C (+ 68 F to + 140 F) repeated, 56 LEONI

Order number Dimensions Outer diameter LEHC 003605 4 x 0.75 + (2 x 0.50) 9.9 (0.39) LEHC 003393 4 x 1.00 + (2 x 0.50) 10.1 (0.40) LEHC 003394 4 x 1.00 + (2 x 1.00) 10.8 (0.43) LEHC 003395 4 x 1.50 + (2 x 0.50) 11.5 (0.45) LEHC 003396 4 x 1.50 + (2 x 0.75) 11.8 (0.46) LEHC 003397 4 x 1.50 + (2 x 1.00) 12.1 (0.48) LEHC 002107 4 x 1.50 + (2 x 1.50) 12.5 (0.49) LEHC 003398 4 x 2.50 + (2 x 0.50) 13.0 (0.51) LEHC 003399 4 x 2.50 + (2 x 0.75) 13.3 (0.52) LEHC 003400 4 x 2.50 + (2 x 1.00) 13.5 (0.53) LEHC 002110 4 x 2.50 + (2 x 1.50) 13.8 (0.54) LEHC 003401 4 x 4.00 + (2 x 1.00) 14.7 (0.58) LEHC 003402 4 x 6.00 + (2 x 1.00) 16.5 (0.65) LEHC 003403 4 x 10.00 + (2 x 1.00) 19.5 (0.77) LEHC 003404 4 x 16.00 + (2 x 1.00) 23.2 (0.91) LEHC 002114 4 x 4.00 + (2 x 1.50) 15.0 (0.59) LEHC 002117 4 x 6.00 + (2 x 1.50) 16.7 (0.66) LEHC 002120 4 x 10.00 + (2 x 1.50) 19.5 (0.77) LEHC 002139 4 x 16.00 + (2 x 1.50) 23.2 (0.91) LEHC 003527 4 x 25.00 + (2 x 1.00) 27.0 (1.06) LEHC 002140 4 x 25.00 + (2 x 1.50) 27.0 (1.06) LEHC 003980 4 x 35.0 + (2 x 1.00) 31.0 (1.22) LEHC 002141 4 x 35.00 + (2 x 1.50) 31.0 (1.22) LEHC 002455 4 x 50.00 + (2 x 1.50) 35.0 (1.38) LEONI 57

diese Zeichnungen habe ich nicht gefunden FieldLink MC Hybrid cable for permanent installation and flexible applications with low mechanical stress oil resistant acc. to DIN VDE 0281 Part 1 / HD21.1S3 Conductor Stranded bare copper wire acc. to IEC 60228 Cl.5 and Cl. 6, insulation optional of Polyolefine or PVC, wire identification power: black, white with numbers 1, 2, 3, GNYE, signal: 1st pair 5, 6, 2nd pair, 7, 8 Signal wires: twisted to pairs, tape-wrapped foils, braidings of tinned copper wires (covering 85 %); pairs and four wires twisted in layer with fillers in gaps and central filler Jacket Polyvinylchloride (PVC) orange acc. to RAL 2003 0.6 / 1 kv for power and 24 V for signal (DIN VDE), 1000 V for power and signal (UL / CSA) Minimum bending radius allowed 5 x outer diameter (single), 20 x outer diameter (repeated) 2 m/s² (6.56 ft/s²) 30 m/min (98.43 ft/min) 100.000 at 20 x outer diameter ± 30 /m ( ± 9.15 /ft) 20 C to + 80 C ( 4 F to + 176 F) single, + 0 C to + 60 C (+ 32 F to + 140 F) repeated, Order number Dimensions Outer diameter LEHC 003378 4 x 0.75 + 2 x (2 x 0.34) 10.6 (0.42) LEHC 003379 4 x 1.00 + 2 x (2 x 0.75) 12.0 (0.47) LEHC 003380 4 x 1.50 + 2 x (2 x 0.75) 12.3 (0.48) LEHC 003381 4 x 2.50 + 2 x (2 x 0.75) 13.8 (0.54) LEHC 003382 4 x 2.50 + 2 x (2 x 1.00) 14.2 (0.56) LEHC 003383 4 x 4.00 + (2 x 1.00) + (2 x 1.50) 15.7 (0.62) LEHC 003384 4 x 6.00 + (2 x 1.00) + (2 x 1.50) 17.7 (0.70) LEHC 003385 4 x 10.00 + (2 x 1.00) + (2 x 1.50) 22.8 (0.90) LEHC 003386 4 x 10.00 + 2 x (2 x 1.50) 23.0 (0.91) LEHC 003387 4 x 16.00 + 2 x (2 x 1.50) 26.8 (1.06) LEHC 003388 4 x 25.00 + 2 x (2 x 1.50) 29.5 (1.16) 58 LEONI

Hybrid cable for flexible installation with high mechanical stress high endurance trailing applicable DIN VDE 0282 Part 10 and VDE 472-803 Part B halogen free acc. to IEC 60754 Conductor Stranded bare copper wire acc. to IEC 60228 Cl. 5 and Cl. 6, insulation of TPE and PP, wire identification power: black, white with numbers 1, 2, 3, GNYE, signal: 1st pair 5, 6, 2nd pair 7, 8 Signal wires: twisted to pairs, tape-wrapped foils, braidings of tinned copper wires (covering 85 %); pairs and four wires twisted in layer with fillers in gaps and central filler, fleece foil overlapped Jacket Thermoplastic Polyurethane (TPU) orange acc. to RAL 2003 0.6 / 1 kv for power and 24 V for signal (DIN VDE), 1000 V for power and signal (UL / CSA) Minimum bending radius allowed 6 x outer diameter (single), 12 x outer diameter (repeated) 5 m/s² (16.40 ft/s²) 180 m/min (590.55 ft/min) 10.000.000 at 12 x outer diameter ± 30 /m ( ± 9.15 /ft) 50 C to + 80 C ( 58 F to + 176 F) single, 20 C to + 60 C ( 4 F to + 140 F) repeated, Order number Dimensions Outer diameter LEHC 003377 4 x 0.75 + 2 x (2 x 0.34) 10.8 (0.43) LEHC 002479 4 x 1.00 + 2 x (2 x 0.75) 12.0 (0.47) LEHC 002054 4 x 1.50 + 2 x (2 x 0.75) 12.4 (0.49) LEHC 003306 4 x 2.50 + 2 x (2 x 0.75) 13.8 (0.54) LEHC 003335 4 x 2.50 + 2 x (2 x 1.00) 15.2 (0.60) LEHC 003406 4 x 4.00 + (2 x 1.00) + (2 x 1.50) 16.7 (0.66) LEHC 003407 4 x 6.00 + (2 x 1.00) + (2 x 1.50) 18.6 (0.73) LEHC 003336 4 x 10.00 + (2 x 1.00) + (2 x 1.50) 22.5 (0.89) LEHC 003408 4 x 10.00 + 2 x (2 x 1.50) 23.0 (0.91) LEHC 003409 4 x 16.00 + 2 x (2 x 1.50) 25.5 (1.00) LEHC 003410 4 x 25.00 + 2 x (2 x 1.50) 28.5 (1.12) LEONI 59