Power cable for permanent installation and flexible applications with low mechanical stress DIN VDE 0281 Part 1 / HD21.1S3 Conductor Stranded bare copper wire acc. to IEC 60228 Cl.5 and Cl. 6, insulation optional of Polyolefine and PVC, wire identification V/L2, U/L1/C/L+, W/L3/L-, GNYE Four wires twisted in layers with fillers in gaps Jacket Polyvinylchloride (PVC) orange acc. to RAL 2003 0.6 / 1 kv (DIN VDE), 1000 V (UL / CSA) 4 kv 50Hz AC (wires) Minimum bending radius allowed 5 x outer diameter (single), 20 x outer diameter (repeated) 2 m/s² (6.56 ft/s²) 30 m/min (98.43 ft/min) 100 000 at 20 x outer diameter ± 30 /m ( ± 9.15 /ft) 20 C to + 80 C ( 4 F to + 176 F) single, + 0 C to + 60 C (+ 32 F to + 140 F) repeated, Order number Dimensions Outer diameter LEC 003344 4 x 1.50 8.0 (0.31) LEC 003346 4 x 2.50 9.6 (0.38) LEC 003348 4 x 4.00 11.0 (0.43) LEC 003350 4 x 6.00 13.1 (0.52) LEC 003352 4 x 10.00 19.5 (0.77) LEC 003354 4 x 16.00 23.5 (0.93) LEC 003356 4 x 25.00 27.0 (1.06) LEC 003358 4 x 35.00 30.5 (1.20) LEC 003360 4 x 50.00 36.5 (1.44) 52 LEONI
Power cable for flexible installation with high mechanical stress high endurance trailing applicable DIN VDE 0282 Part 10 / HD 22.10 S1 halogen free acc. to IEC 60754 Conductor Stranded bare copper wire acc. to IEC 60228 Cl. 6, insulation of TPE and PP, wire identification V/L2, U/L1/C/L+, W/L3/D/L-, GNYE Four wires twisted in layers with fillers in gaps Jacket Thermoplastic Polyurethane (TPU) orange acc. to RAL 2003 0.6 / 1 kv (DIN VDE), 1000 V (UL / CSA) Minimum bending radius allowed 6 x outer diameter (single), 12 x outer diameter (repeated) 5 m/s² (16.40 ft/s²) 180 m/min (590.55 ft/min) 10.000.000 at 12 x outer diameter ± 30 /m ( ± 9.15 /ft) 50 C to + 80 C ( 58 F to + 176 F) single, 20 C to + 60 C ( 4 F to + 140 F) repeated, Order number Dimensions Outer diameter LEC 002106 4 x 1.50 10.0 (0.39) LEC 002109 4 x 2.50 11.7 (0.46) LEC 002112 4 x 4.00 12.8 (0.50) LEC 002116 4 x 6.00 15.0 (0.59) LEC 002119 4 x 10.00 18.5 (0.73) LEC 002121 4 x 16.00 22.0 (0.87) LEC 002450 4 x 25.00 25.5 (1.00) LEC 002452 4 x 35.00 29.5 (1.16) LEC 002454 4 x 50.00 33.5 (1.32) LEONI 53
Hybrid cable for permanent installation and flexible applications with low mechanical stress DIN VDE 0281 Part 1 / HD21.1S3 Conductor Stranded bare copper wire acc. to IEC 60228 Cl.5 and Cl. 6, insulation optional of Polyolefine, TPE and PVC, wire identification power: V/L2, U/L1/C/L+, W/L3/L-, GNYE, signal: black, white Signal wires: twisted to a pair, tape-wrapped foil, spinning of copper wires (covering 85 %); pair and four wires twisted in layer with fillers in gaps and central filler Jacket Polyvinylchloride (PVC) orange acc. to RAL 2003 0.6 / 1 kv for power and 24 V for signal (DIN VDE), 1000 V for power and signal (UL / CSA) Minimum bending radius allowed 5 x outer diameter (single), 20 x outer diameter (repeated) 2 m/s² (6.56 ft/s²) 30 m/min (98.43 ft/min) 100.000 at 20 x outer diameter ± 30 /m ( ± 9.15 /ft) 20 C to + 80 C ( 4 F to + 176 F) single, + 0 C to + 60 C (+ 32 F to + 140 F) repeated, 54 LEONI
Order number Dimensions Outer diameter LEHC 003363 4 x 1.00 + (2 x 0.50) 9.6 (0.38) LEHC 003364 4 x 1.00 + (2 x 0.75) 10.0 (0.39) LEC 003962 4 x 1.00 + (2 x 1.00) 10.2 (0.40) LEHC 003963 4 x 1.00 + (2 x 1.50) 10.5 (0.41) LEHC 003365 4 x 1.50 + (2 x 0.50) 10.0 (0.39) LEHC 003366 4 x 1.50 + (2 x 0.75) 10.3 (0.41) LEHC 003057 4 x 1.50 + (2 x 1.00) 10.4 (0.41) LEHC 003345 4 x 1.50 + (2 x 1.50) 10.5 (0.41) LEHC 003367 4 x 2.50 + (2 x 0.50) 11.5 (0,45) LEHC 003368 4 x 2.50 + (2 x 0.75) 11.8 (0.46) LEHC 003369 4 x 2.50 + (2 x 1.00) 12.0 (0.47) LEHC 003347 4 x 2.50 + (2 x 1.50) 12.0 (0.47) LEHC 003370 4 x 4.00 + (2 x 1.00) 13.4 (0.53) LEHC 003371 4 x 6.00 + (2 x 1.00) 15.3 (0.60) LEHC 003372 4 x 10.00 + (2 x 1.00) 20.8 (0.82) LEHC 003373 4 x 16.00 + (2 x 1.00) 24.0 (0.94) LEHC 003349 4 x 4.00 + (2 x 1.50) 13.5 (0.53) LEHC 003351 4 x 6.00 + (2 x 1.50) 15.6 (0.61) LEHC 003353 4 x 10.00 + (2 x 1.50) 21.0 (0.83) LEHC 003355 4 x 16.00 + (2 x 1.50) 24.1 (0.95) LEHC 003357 4 x 25.00 + (2 x 1.50) 28.5 (1.12) LEHC 003359 4 x 35.00 + (2 x 1.50) 31.5 (1.24) LEHC 003361 4 x 50.00 + (2 x 1.50) 36.5 (1.44) LEONI 55
Hybrid cable for flexible installation with high mechanical stress high endurance trailing applicable DIN VDE 0282 Part 10 / HD 22.10 S1 halogen free acc. to IEC 60754 Conductor Stranded bare copper wire acc. to IEC 60228 Cl. 6, insulation of TPE and PP, wire identification power: V/L2, U/L1/C/L+, W/L3/D/L-, GNYE, signal: black, white Signal wire: twisted to pair, tape-wrapped foil, spinning of tinned copper wires (covering 85 %); pair and four wires twisted in layer with fillers in gaps and central filler Jacket Thermoplastic Polyurethane (TPU) orange acc. to RAL 2003 0.6 / 1 kv for power and 24 V for signal (DIN VDE), 1000 V for power and signal (UL / CSA) Minimum bending radius allowed 6 x outer diameter (single), 12 x outer diameter (repeated) 5 m/s² (16.40 ft/s²) 180 m/min (590.55 ft/min) 10.000.000 at 12 x outer diameter ± 30 /m ( ± 9.15 /ft) 50 C to + 80 C (-58 F to +176 F) single, 20 C to + 60 C (+ 68 F to + 140 F) repeated, 56 LEONI
Order number Dimensions Outer diameter LEHC 003605 4 x 0.75 + (2 x 0.50) 9.9 (0.39) LEHC 003393 4 x 1.00 + (2 x 0.50) 10.1 (0.40) LEHC 003394 4 x 1.00 + (2 x 1.00) 10.8 (0.43) LEHC 003395 4 x 1.50 + (2 x 0.50) 11.5 (0.45) LEHC 003396 4 x 1.50 + (2 x 0.75) 11.8 (0.46) LEHC 003397 4 x 1.50 + (2 x 1.00) 12.1 (0.48) LEHC 002107 4 x 1.50 + (2 x 1.50) 12.5 (0.49) LEHC 003398 4 x 2.50 + (2 x 0.50) 13.0 (0.51) LEHC 003399 4 x 2.50 + (2 x 0.75) 13.3 (0.52) LEHC 003400 4 x 2.50 + (2 x 1.00) 13.5 (0.53) LEHC 002110 4 x 2.50 + (2 x 1.50) 13.8 (0.54) LEHC 003401 4 x 4.00 + (2 x 1.00) 14.7 (0.58) LEHC 003402 4 x 6.00 + (2 x 1.00) 16.5 (0.65) LEHC 003403 4 x 10.00 + (2 x 1.00) 19.5 (0.77) LEHC 003404 4 x 16.00 + (2 x 1.00) 23.2 (0.91) LEHC 002114 4 x 4.00 + (2 x 1.50) 15.0 (0.59) LEHC 002117 4 x 6.00 + (2 x 1.50) 16.7 (0.66) LEHC 002120 4 x 10.00 + (2 x 1.50) 19.5 (0.77) LEHC 002139 4 x 16.00 + (2 x 1.50) 23.2 (0.91) LEHC 003527 4 x 25.00 + (2 x 1.00) 27.0 (1.06) LEHC 002140 4 x 25.00 + (2 x 1.50) 27.0 (1.06) LEHC 003980 4 x 35.0 + (2 x 1.00) 31.0 (1.22) LEHC 002141 4 x 35.00 + (2 x 1.50) 31.0 (1.22) LEHC 002455 4 x 50.00 + (2 x 1.50) 35.0 (1.38) LEONI 57
diese Zeichnungen habe ich nicht gefunden FieldLink MC Hybrid cable for permanent installation and flexible applications with low mechanical stress oil resistant acc. to DIN VDE 0281 Part 1 / HD21.1S3 Conductor Stranded bare copper wire acc. to IEC 60228 Cl.5 and Cl. 6, insulation optional of Polyolefine or PVC, wire identification power: black, white with numbers 1, 2, 3, GNYE, signal: 1st pair 5, 6, 2nd pair, 7, 8 Signal wires: twisted to pairs, tape-wrapped foils, braidings of tinned copper wires (covering 85 %); pairs and four wires twisted in layer with fillers in gaps and central filler Jacket Polyvinylchloride (PVC) orange acc. to RAL 2003 0.6 / 1 kv for power and 24 V for signal (DIN VDE), 1000 V for power and signal (UL / CSA) Minimum bending radius allowed 5 x outer diameter (single), 20 x outer diameter (repeated) 2 m/s² (6.56 ft/s²) 30 m/min (98.43 ft/min) 100.000 at 20 x outer diameter ± 30 /m ( ± 9.15 /ft) 20 C to + 80 C ( 4 F to + 176 F) single, + 0 C to + 60 C (+ 32 F to + 140 F) repeated, Order number Dimensions Outer diameter LEHC 003378 4 x 0.75 + 2 x (2 x 0.34) 10.6 (0.42) LEHC 003379 4 x 1.00 + 2 x (2 x 0.75) 12.0 (0.47) LEHC 003380 4 x 1.50 + 2 x (2 x 0.75) 12.3 (0.48) LEHC 003381 4 x 2.50 + 2 x (2 x 0.75) 13.8 (0.54) LEHC 003382 4 x 2.50 + 2 x (2 x 1.00) 14.2 (0.56) LEHC 003383 4 x 4.00 + (2 x 1.00) + (2 x 1.50) 15.7 (0.62) LEHC 003384 4 x 6.00 + (2 x 1.00) + (2 x 1.50) 17.7 (0.70) LEHC 003385 4 x 10.00 + (2 x 1.00) + (2 x 1.50) 22.8 (0.90) LEHC 003386 4 x 10.00 + 2 x (2 x 1.50) 23.0 (0.91) LEHC 003387 4 x 16.00 + 2 x (2 x 1.50) 26.8 (1.06) LEHC 003388 4 x 25.00 + 2 x (2 x 1.50) 29.5 (1.16) 58 LEONI
Hybrid cable for flexible installation with high mechanical stress high endurance trailing applicable DIN VDE 0282 Part 10 and VDE 472-803 Part B halogen free acc. to IEC 60754 Conductor Stranded bare copper wire acc. to IEC 60228 Cl. 5 and Cl. 6, insulation of TPE and PP, wire identification power: black, white with numbers 1, 2, 3, GNYE, signal: 1st pair 5, 6, 2nd pair 7, 8 Signal wires: twisted to pairs, tape-wrapped foils, braidings of tinned copper wires (covering 85 %); pairs and four wires twisted in layer with fillers in gaps and central filler, fleece foil overlapped Jacket Thermoplastic Polyurethane (TPU) orange acc. to RAL 2003 0.6 / 1 kv for power and 24 V for signal (DIN VDE), 1000 V for power and signal (UL / CSA) Minimum bending radius allowed 6 x outer diameter (single), 12 x outer diameter (repeated) 5 m/s² (16.40 ft/s²) 180 m/min (590.55 ft/min) 10.000.000 at 12 x outer diameter ± 30 /m ( ± 9.15 /ft) 50 C to + 80 C ( 58 F to + 176 F) single, 20 C to + 60 C ( 4 F to + 140 F) repeated, Order number Dimensions Outer diameter LEHC 003377 4 x 0.75 + 2 x (2 x 0.34) 10.8 (0.43) LEHC 002479 4 x 1.00 + 2 x (2 x 0.75) 12.0 (0.47) LEHC 002054 4 x 1.50 + 2 x (2 x 0.75) 12.4 (0.49) LEHC 003306 4 x 2.50 + 2 x (2 x 0.75) 13.8 (0.54) LEHC 003335 4 x 2.50 + 2 x (2 x 1.00) 15.2 (0.60) LEHC 003406 4 x 4.00 + (2 x 1.00) + (2 x 1.50) 16.7 (0.66) LEHC 003407 4 x 6.00 + (2 x 1.00) + (2 x 1.50) 18.6 (0.73) LEHC 003336 4 x 10.00 + (2 x 1.00) + (2 x 1.50) 22.5 (0.89) LEHC 003408 4 x 10.00 + 2 x (2 x 1.50) 23.0 (0.91) LEHC 003409 4 x 16.00 + 2 x (2 x 1.50) 25.5 (1.00) LEHC 003410 4 x 25.00 + 2 x (2 x 1.50) 28.5 (1.12) LEONI 59