Stormwater Solutions. Jacopa Penstocks. Key Features & Benefits: How We Create Value:

Similar documents
Digital flow ELEMENT transmitter for continuous flow measurement

Planning and realising of penstocks

PENSTOCKS Sluice Gates

Digital flow transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement

INLINE flowmeter for continuous flow measurement

VALVES AND PENSTOCKS FOR WATER

2/2 way Proportional Valve (motordriven)

PENSTOCK VALVES. Performance through Excellence

FES SUBSEA HOT STAB. FES Subsea Merchant Court, Ashington, Northumberland, England, NE63 0YH

SLIDE GATE SERVICE CONDITIONS

Digital inductive conductivity transmitter

INLINE flowmeter for continuous flow measurement

RCM DIRECT READING FLOWMETER

Electromagnetic Flow Transmitter

KFS. Flap-type flow meter. Design and range of application

QUALITY THROUGH EXPERIENCE-SINCE 1963

INLINE flowmeter for continuous flow measurement

Volumetric flow controller

2-way motor valve. Power consumption. Type 8746 MFC/MFM. Technical data Materials Body Housing Seals 1) Pressure Range 2) < 1 % FS Sensitivity Span

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector

SonoMeter 31 Energy Meters

SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

INSERTION paddle wheel flowmeter for continuous flow measurement

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

200 x x 3000mm

AVK PENSTOCK SOLUTIONS PENSTOCK SOLUTIONS

SLIDE GATE. The MU series is used mainly in water treatment, irrigation, hydraulic works and hydro-electric power plants.

ANDERSON GREENWOOD SAFETY SELECTOR VALVE

WATERFLUX 3070 Technical Datasheet

Flush pressure transmitter For viscous and solids-containing media Model S-11

Type overview. Technical data

CONSTRUCTION MATERIALS

WATER METERS M SERIES WATER METERS INSTALLATION, OPERATION AND MAINTENANCE GUIDE METAL M SERIES WATER METER PLASTIC M SERIES WATER METER

CONSTRUCTION MATERIALS SERVICE CONDITIONS. Alternative alloy materials, like AISI 904L or DUPLEX stainless steel, are available if required.

Ambient Conditions. Operating Conditions. Pressure

Maintenance Hole Structures Technical Addendum Background

SM-10. Features. Variable Area Flowmeter with Sight Glass for Small Flow Volumes. Description: Application: / Indication without power supply

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector

2/2-Way Solenoid Control Valve

Size : Connection End : Min Temperature : Max Temperature : Materials : Cast iron body

MBC /602(L) MBC /602(L) MBC /602(L)

INVICTA PENSTOCK SOLUTIONS PENSTOCK SOLUTIONS

WATERFLUX 3000 Quick Start

Design and applications

Essex County College - West Essex Campus Addition And Renovations dlb # / SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

ph or ORP Transmitter

Condumax W CLS15 and CLS15D

Swivel Sector Radial Penstock

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016

TIDALFLUX 2300 F Technical Datasheet

KFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite

SONO 1500 CT Ultrasonic flow sensor

Insertion Flow sensor for continuous flow measurement

Ancillary Equipment.

ELECTROMAGNETIC FLOW METER AFLOWT MF

Digital conductivity transmitter

Madison Metropolitan Sewerage District Notice of Request for Proposals

RS /E-EV BLU SERIES

SECTION MANHOLES

WATERFLUX 3000 Quick Start

RS /M MZ SERIES

UFM 800 W, C Ultrasonic flowmeter for water and wastewater

7000 Series Bronze Globe Valves Two-Way Normally Open

ATG SERIES Growco Servo Tank Gauges

Magnetic Inductive Flow Sensors VMI Series

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement

A. Compatibility: Products shall be suitable for piping service fluids, materials, working pressures, and temperatures.

Atlantic. Industrial High Power Picosecond Lasers. features

RS /E-EV BLU SERIES

Magnetic Inductive Flow Sensors induq. Series VMI

Ring Type Joint CALVOSEALING DESCRIPTION

Aronde range. Development. Modular assembly of rotomoulded tanks. Balance-float automatic closing device. Extension of the modular range

USER MANUAL MODEL USFT-CS ULTRASONIC FLOW TRANSMITTER. Rev04009 USER MANUAL DEI MODEL USFT-CS

This specification describes the minimum requirements for service water piping systems (ie: cooling water, process water, etc.), located on surface.

FA-3300 Heavy Duty Electric Actuator. Features and Benefits. FA-3300 Actuator with VG8000 valve. Constant running time. Fixed close-off force.

The transducer component converts the measured signal and displays the actual value.

Chapter 3. Experimental set up. 3.1 General

COMMERCIAL LOW PROFILE 8 Electric Heated Air Curtain Data Sheet

Evaporator E2 Series. Innovative Refrigeration Solutions. Medium & Low Temperature Models. Issue: 05/14

MR Modulo Adjustable Constant Airflow Regulator

Rosemount TGU 65 Tank Radar Gauge, Still Pipe Antenna

BOX CULVERTS DRAINAGE & WATER MANAGEMENT. v2.1

Coriolis Mass Flow Measuring System promass 40 E

Design Data 12M. Hydraulic Capacity of Precast Concrete Boxes. RISE, Millimeters. Span Millimeters

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Condumax CLS15 and CLS15D

Vacuum Chamber Datum QFC Case

Conductivity sensor for hygienic applications

OPTIFLUX 5000 Technical Datasheet

KMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm)

Condumax CLS15 and CLS15D

This specification describes the minimum requirements for piping systems for the following service:

THE IMPORTANCE OF THE FITTING

OPTIFLUX 1000 Technical Datasheet

Model LBS Miniature Compression Load Button

SITRANS F flowmeters SITRANS F US. Flowmeter FUE380 with approval. 4/230 Siemens FI Overview

HBS-AP ASSEMBLING INSTRUCTIONS

BOX CULVERTS DRAINAGE & WATER MANAGEMENT. v2.1

Transcription:

Key Features & Benefits: Suitable for Sewerage systems Suitable for Surface water systems Suitable for the control of Watercourses How We Create Value: Can provide a level of Flow control Provides high degree of Isolation Bespoke manufacture accommodated

Type FS Penstock Is a robust product made from high quality stainless steel, either 304 or 316L with brass wedges and EPDM ring seal, providing a low maintenance solution. Standard sizes available are from 100 mm to 1000 mm diameter in 50 mm increments. Where a penstock is required to be installed within a circular chamber, Jacopa can supply a stainless steel adapter, manufactured to the chamber curvature. Overall Dimensions of FS & DS Penstocks Nominal H W D A Weight Diameter Height Width Depth Flange mm mm mm mm mm Kg 100 400 250 70 40 18 150 500 300 70 40 23 200 600 350 70 40 34 250 700 400 70 40 42 300 800 450 72 40 54 350 900 550 72 40 73 400 1000 600 72 40 86 450 1100 650 75 40 95 500 1200 700 75 40 112 550 1400 850 75 70 600 1500 900 95 95 650 1600 950 95 70 700 1700 1000 95 70 750 1800 1050 95 70 800 1900 1100 95 70 850 2000 1150 115 70 900 2100 1200 115 70 950 2200 1250 115 70 1000 2300 1300 115 70

Type FS EL Penstock (with Electrical Actuator) The FS Penstock range can be fitted with an electrical actuator to enable powered control of the opening / closing/ this can be controlled via a level controller / control panel to action the penstock at certain level conditions. Rotork or Auma modulating Actuator, operated via local Control panel.

Type DS Penstock (Throttle Penstock) The throttle penstock is used to reduce the flow passing downstream to prevent hydraulic overloading of the downstream network. As the maximum flow rate is achieved at maximum head, the orifice of the penstock can be calculated to have a certain opening to limit the maximum flow required. Adjustment: The required flow rate is pre-calibrated at the factory in accordance with the adjustment table. This initial flow rate can be adjusted by the client on site. The unit can be adjusted in-situ by using the scale located on the side of the unit. DS Standard Flow Rates Nominal Max Flow Rate Size Head From To DN m l/s 100 2 2 10 150 2 8 26 200 2 10 48 250 2 20 82 300 2 35 128 350 2 60 185 400 2 80 256 450 3 140 340 500 3 210 438 550 3 300 550 600 3 370 680 650 3 450 820 700 3 540 990 750 3 650 1170 800 3 760 1370 850 3 890 1590 900 3 1020 1830 950 3 1170 2090 1000 3 1330 2400 Comments Not recommended for use in foul sewers with flows less than 60 l/s. Higher heads available on application

SA Float Controlled Penstock The SA Penstock has a float which operates a shutter to open / close the orifice. This type of penstock can be used to prevent surcharging up a lateral pipe, or limit the water level within a chamber. The SA Penstock can be used to close an inlet or outlet of a chamber at a pre-determined position. This unit is non-powered and can be a cost effective option to using a powered penstock. When the float is in its lowest position, the orifice is fully open; as the float rises, the shutter reduces the orifice area, reducing the flow. When the float reaches its top position the orifice is completely closed. DN H W T A L1 Float Position* L2 Float Position* D Weight Height Width Min Open Closed Max Open Closed mm mm mm mm mm O1** C1 mm O2** C2 mm Kg mm mm mm mm 100 400 250 220 40 560 190 300 640 190 316 150 18 150 500 300 250 40 640 265 450 770 265 488 150 23 200 600 350 280 40 770 340 600 950 340 661 200 34 250 700 400 310 40 900 415 750 1130 415 836 250 42 300 800 450 350 40 1020 490 900 1300 490 1013 300 54 350 900 550 380 40 1160 565 1050 1490 565 1188 350 73 400 1000 600 420 40 1300 640 1200 1670 640 1359 400 86 450 1100 650 460 40 1430 715 1350 1850 715 1537 450 95 500 1200 700 490 40 1550 790 1500 2020 790 1715 500 112 550 1400 850 570 70 1830 865 1650 2220 865 1817 550 152 600 1500 900 600 70 1970 940 1800 2410 940 1992 600 231 650 1600 950 640 70 2110 1015 1950 2600 1015 2167 650 700 1700 1000 700 70 2260 1090 2100 2800 1090 2341 700 750 1800 1050 740 70 2390 1165 2250 2980 1165 2518 750 410 800 1900 1100 760 70 2530 1240 2400 3170 1240 2693 800 650 850 2000 1150 820 70 2680 1315 2550 3370 1315 2868 850 900 2100 1200 840 70 2810 1390 2700 3550 1390 3045 900 950 2200 1250 890 70 2950 1465 2850 3740 1465 3221 950 1000 2300 1300 930 70 3040 1540 3000 3880 1540 3403 1000 *Nominal Condition, can differ depending upon water head. **Vertical position as shown on drawing detail. Sizes from 100 mm to 1000 mm are manufactured as standard units, but other sizes and requirements can be accommodated. The float radius can be adjusted to alter open / closed positions if required. The standard models are manufactured to resist an upstream head of 3m, but can be strengthened if a higher head is likely. This needs to be determined at time of design. The following table provides size details of the standard units and open / closed positions.

Copyright 2017 Jacopa. All rights reserved.