Installation Manual. UL 325 Compliant. For Pre-2016 Convenience Open Operators ONLY

Similar documents
601/602 Series Inductive Loop Detector

G703. Installation instructions. residential gate opener for sliding gates. remote control openers security at your fingertips

IRRIGATION 810-3R RECEIVER GUIDE

Operating Instructions

MFJ ENTERPRISES, INC.

Blue Point Engineering

Keyed latch. Cover. Service Outlet 115VAC, 15A. Plastic base. Unpack. Operator. the Operator

The Smallest, Quietest & Safest Garage Door Operator in the World!

IRRIGATION 810-R RECEIVER GUIDE

HANDS-FREE KEYLESS ENTRY AUTHF500

With Audible Detect Signal

BFS / BFSM SERIES Installation & Maintenance Manual

MODEL 421 Over/Under Motor Load Monitor

MFJ ENTERPRISES, INC.

R PROFLAME Instruction Book Collection

LRA Linear Residential Actuator Installation Guide

TEAM DIGITAL. SMC4 Servo & Motor Controller

LBI-31807D. Mobile Communications MASTR II REPEATER CONTROL PANEL 19B234871P1. Maintenance Manual. Printed in U.S.A.

GATE LIMIT RELAY KIT INSTALLATION INSTRUCTIONS GATE OPERATORS:

S1 Programming Chart Program Description S1 Switch Positions. Constant ON High/Low Track, WR

AMERITRON SDC-102 Screwdriver Antenna Controller

Sealed Interface Control: EC20300

Wireless Rain and Wireless Rain/Freeze Sensor

IMPORTANT! Please take the time to read through the manual before you start to install/program your equipment.

Blue Point Engineering

MD12-2 Metal Loop Detector

IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K

MBC Bipolar Microstep Driver. User s Guide E. Landon Drive Anaheim, CA

LONG RANGE REMOTE RECEIVER WITH TRANSMITTER FOR BUNGALOWS AND BANKS MODEL KE - 2 L R

High/Low Bay Passive Infrared Occupancy Sensor

Blue Point Engineering

USERS GUIDE MATRIX P/N SINGLE DIGITAL INDUCTIVE LOOP SENSOR

CS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL

Installation Notes. SCR Single Channel

DECORATOR COMFORT CONTROL (DCC)

IRRIGATION 810-T PLUS TRANSMITTER GUIDE

Series 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual

POWER TRACE TM TASCO, INC.

IMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED. READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION.

HT101V Reference Manual

Lazerpoint TM RF RX-91 Basic Receiver Installation Instructions

SA-027HQ 365-Day Annual Timer

SF Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

T-L 810-T TRANSMITTER GUIDE

Detcon Model FP Transmitter Test Fixture Operators Instruction Manual June 17, 2008 * Document 3389 * Revision 1.1

LP 600 Orion Electronic Dimmer for Magnetic Adapters in Poultry Houses User Manual

Radio Control Installation and Operating Instructions System 4

Model 935A. Dual Tone Sender INSTRUCTION MANUAL

Service Instructions. The Conductor Controls. Conductor DC15-A, Enclosed Unit CH15-A, Open Chasis Unit

SCHLAGE WIRELESS ACCESS SYSTEM (WAS)

WARRANTY. Long Range Systems, LLC, 20 Canal St, Suite 4N, Franklin, NH 03235

Instructions for programming and use Starline Roldeck - floorpanel control RD-2001

IMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

IRRIGATION 810-T TRANSMITTER GUIDE

Installation Instructions

SHIRTS AND SKINS JUNIOR EDITION COASTAL AMUSEMENTS INC SWARTHMORE AVE LAKEWOOD, NJ TEL: FAX:

TR1000 IRRIGATION MANUAL

CAME QP- V4.4 SPECIFICATION STANDARDS CABLE PLAN CABLE TYPES Z SERIES AUDIOCODE CONTROL SET FOR DOUBLE LEAF GATES

Quantizer step: volts Input Voltage [V]

3 CHANNEL LOAD CELL SIGNAL CONDITIONER. Owner's Manual

3.0 Operating the MIB* Barrier Gate. 4.0 MLC Controller. Operation Instructions. 4.1 General

USERS GUIDE MATRIX2 DIGITAL INDUCTIVE LOOP SENSORS

Wireless Vehicle Sensor Installation Manual

2.4GHZ WIRELESS SYSTEM FOR POLICE VIDEO RECORDING

Operations Manual. Model NT11 & NT11-E. June 18 th 2002

RCDC2 Radio Controlled Device Controller- 2 channel

The wireless alternative to expensive cabling...

Figure 1. DMC 60 components.

Installation and Operation Manual

X80 Activator. User's Manual. Version 1.1.

OWNERS MANUAL FOR STERLING SERIES CONTROLLERS

TECHNICAL PRODUCT DATASHEET

Underground Loops and Loop Detectors. DoorKing Plug-In Loop Detectors and Loop Accessories Single Channel CH1

Scorpion Antennas Controller. Instruction Manual. Firmware V11.8 November Please Read This Manual Completely Before Operating The Controller

Installation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION

UNIT A 8-30VDC 8-28VAC POWER V IN3 IN4 COM1/2 NO3 NO4 IN1 IN2 GND NO1 NO2 COM3/4 ANY 8-28VAC OR 8-30VDC POWER ADAPTER (SOLD SEPARATELY)

Series 962. Operation Manual. Electronic Stager Control TIME OF DAY TIME OF REGEN HARDNESS FLOW SERIES 962 CAPACITY REGEN TIME REMAINING

SHORT FORM. Product Catalog. (800) time-mark.com

OPERATING INSTRUCTIONS AND SERVICE MANUAL HOCKEY SCOREBOARD MODEL MP-5529 WITH MP-5000 CONTROL

YD (MOD A-C) WITH OPTIVIEW CONTROL CENTER FIELD CONTROL MODIFICATIONS

PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL

BAPI-Stat 4 X-Combo, Room %RH and Temp. Sensor BA/BS4XC Installation & Operating Instructions

Channel Remote Programming: For the (35R Motor with or without a Plug) LEFT SIDE AND RIGHT SIDE MOTORS

V-Maxx G2 Hopper Spreader VX-1500

SG - SG-D Barrier Gate Operator Installation Guide

Model 7000 Low Noise Differential Preamplifier

DMX Digital-Servo Board

Aqua-Gen 3PV INSTRUCTIONS

Dual Gate Controller 24 Volt Gate Control System DCB-05V2

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

Q-SERIES. Amplifiers. QPAIR Redundancy Switch Amplifier System. Installation & Operation Manual

Heavy Duty Rolling Door Openers

LINCO MEASUREMENT MODEL CP-2B MASTER METER PROVER COUNTER INSTRUCTION MANUAL

Wireless Temp/Setpoint & Override Room Transmitter

TEAM DIGITAL. Servette TM Single Servo Controller

Process Calibrator. TechChek 820

Directions for Wiring and Using The GEARS II (2) Channel Combination Controllers

Series 3000 Model R-107A

Transcription:

CFORMS TO ANSI/UL- CERTIFIED TO CAN/CSA C.. CLASS MODEL SERIAL HP CFORMS TO ANSI/UL- CERTIFIED TO CAN/CSA C.. CLASS MODEL SERIAL HP CLASS MODEL SERIAL HP Installation Manual Use this manual for circuit board -00. Replacement Convenience Open Board For Pre-0 Convenience Open Models: 00, 0, 0, 00, 00, 00, 0 and 0 s LY For Pre-0 Convenience Open s LY -0-F-- Replacement Board for 0-00 Convenience Open Board 00 0 VEHICULAR GATE OPERATOR VOLTS PHASE AMPS 0 Hz MAX GATE LOAD DoorKing, Inc., Inglewood, CA J VAC WARNING MOVING GATE CAN CAUSE SERIOUS INJURY OR DEATH Operate gate only when gate area is in sight and free of people and obstructions. Do not allow children to play in gate area or operate gate. Do not stand in gate path or walk through path while gate is moving. Read owner s manual and safety instructions. VEHICULAR GATE OPERATOR VOLTS PHASE AMPS 0 Hz MAX GATE LOAD DoorKing, Inc., Inglewood, CA 00 0 0 P BATT 00-00 0 R AC ACT SW WARNING MOVING GATE CAN CAUSE SERIOUS INJURY OR DEATH Operate gate only when gate area is in sight and free of people and obstructions. Do not allow children to play in gate area or operate gate. Do not stand in gate path or walk through path while gate is moving. Read owner s manual and safety instructions. CFORMS TO ANSI/UL- CERTIFIED TO CAN/CSA C.. VEHICULAR GATE OPERATOR VOLTS PHASE AMPS 0 Hz MAX GATE LOAD DoorKing, Inc., Inglewood, CA 0 Date Installed: 0 Installer/pany Name: Phone Number: Leave Manual with Owner Circuit Board Serial Number and Revision Letter: Copyright 0 DoorKing, Inc. All rights reserved. UL pliant

TABLE OF CTENTS CVENIEE OPEN BOARD INTRODUCTI Board Overview DIP-Switches SPECIFIC GATE OPERATOR INSTALLATI 00, 00 Swing Gate (s) 00 Swing Gate (s) 0 Slide Gate (s) 0 Slide Gate (s) 0, 0, 0 Barrier Gate (s) - - - 0- - Replacement Parts for Convenience Open System DoorKing, Inc. reserves the right to make changes in the products described in this manual without notice and without obligation of DoorKing, Inc. to notify any persons of any such revisions or changes. Additionally, DoorKing, Inc. makes no representations or warranties with respect to this manual. This manual is copyrighted, all rights reserved. No portion of this manual may be copied, reproduced, translated, or reduced to any electronic medium without prior written consent from DoorKing, Inc. -0-F--

CVENIEE OPEN BOARD INTRODUCTI Use this manual when replacing a 0-00 convenience open board on an existing PRE-0 gate/barrier operator LY. The 0-00 control board is obsolete and cannot be replaced. IMPORTANT The convenience open board is a REPLACEMENT board for an existing 0 convenience open board LY. The convenience open system cannot provide continuous gate operation during a power outage. Operation of this system is limited to cycling the gate to the open (up) position E LY. The convenience open system requires testing on a monthly basis to insure the batteries are fully charged and that the system is operational. The convenience open system uses two -volt,.0 amp-hour gel-cell batteries. These batteries should be replaced every two years on average, or sooner if required. A reminder beeper has been designed in the board, see below. are affected by temperature. Cold temperatures will reduce the effectiveness of the batteries and the backup system. High temperatures will result in a shortened battery life. are not covered under warranty. This system cannot be used with SLIDE gate operators that are configured in the Fail-SECURE mode. If your access control system requires 00% power backup and continuous operation when primary (AC) power has failed, a power inverter / backup system, such as DoorKing s Model 000 can be purchased separately. Board Overview VAC Input (J) Connect to gate operator s terminal inputs as shown on following pages, REQUIRED. DO T connect to 0/0 VAC input. 0-Pin Terminal (P) COMM- mon for open, radio receiver or open limit switch. Note: Radio receiver cannot be connected when the is installed in a 0, 0, 0, 00 or 0 gate operator. OPEN ()- Open input. (Open limit switch for 0, 0, 0, 00, 0). RADIO POWER- -Volt power for radio receiver (0 and 00/00 gate operators only). Radio gets powered by operator batteries during power outage. ACTIVATI OUTPUT- Radio relay activation or switch closure across terminals and will send an activation signal out of this terminal to the gate operator single-button activation input. VAC --Not Used VAC COMM- BATTERY POSITIVE - BATTERY NEGATIVE - DC MOTOR POSITIVE OUTPUT- DC MOTOR NEGATIVE OUTPUT-0 Note: See pages - for your specific gate operator(s) terminal connection. 0 J VAC P R BATT AC ACT SW -00 DIP-Switches See next page. Reset Button Press to reset board. LED Blinking:Indicates board is operating normally. Adjustment DIP-Switch MUST be OFF to adjust - sec. Clockwise increases the run time, Counter-clockwise decreases the run time. See next page. Clear Stat Button Press and hold the button for secs clears the battery replacement reminder counter and resets the beeping indication. Beeper A beep every 0 seconds indicates that battery replacement is needed. Press and hold the button to reset the battery reminder beeping and clear the counter. Battery LEDs BATT LED Blinks: Replace batteries. Blinks: Battery level is too low. Blinks: are not connected. Blinks: Bad battery. Blinks: Battery charge current exceeds maximum, possible shorted cell. LED Steady LED: Battery is fully charged and a trickle charge is being used to maintain a full charge. LED Steady LED: Battery is being bulk charged. Blinking LED: Battery is 0% of a full charge. LED Blinks: Extreme temperature, charging suspended. -0-F--

DIP-Switches Switch Function Setting Description Auto Open Operation After Power Outage Motor Dir Motor Direction AC on ACT Restore Power Operation Timer-OFF Limit- Type OFF OFF OFF Timer-OFF Limit- (Manual Mode) Residential application: For 00/00 or 0 operators LY. Gate will remain closed after a power outage. A radio receiver input or switch closure device across terminals and will run the operator motor s Run Time set on the to the open position. (0, 0, 0, 00 or 0 models will T function in this mode). (Auto Mode) Apartment complexes, gated communities, etc.: Gate will automatically run the operator motor s Run Time set on the OR use the operator s limits to the open position. This switch MUST be for 0, 0, 0, 00 and 0 operators. Sets the opening direction (up) of the gate. If the gate won t open after a power outage, reverse this switch. Physical Input Required: An input (push button, loop, radio receiver, etc.) is required to return the gate to normal operation again. Auto: a -second pulse is automatically sent to the gate operator input to restore normal operation again. run timer is used and MUST be adjusted. For 0 OR 00/00 gate operators LY. limits are used to stop gate at open/up position. For 0, 0, 0, 00 and 0 operators LY. Switch OFF: Manual Mode - Residential LY Manual mode is designed for residential applications only, for 00/00 or 0 operators LY. (0, 0, 0, 00 or 0 models will T function in this mode). DIP-Switch OFF: the will not open the gate if a power failure occurs until a manual input is received, either from a wired push button or RF transmitter. This allows the gate to remain closed upon a loss of AC power, but provides a method to open the gate when desired. In manual mode, the STAND-ALE RF receiver is connected directly to the control board and is powered by this board. During normal daily operation, when the relay in the radio receiver closes (a valid transmitter code has been received), this signal is passed through the control board s terminal that has been wired to the gate operator s main control board terminal open input. If a power failure occurs, the radio receiver is powered from the operator batteries maintaining its operation. When a valid RF transmitter code is received under these conditions, the control board signals the operator DC motor to run for the set Run Time. A push button device wired to terminals and on the control board will also open the gate after a power outage has occured. Note: The RF transmitter will open the gate when using a stand-alone type receiver. If the gate system uses a receiver that outputs the transmitter code in weigand format to a phone entry system (such as DoorKing s,, or ), then opening the gate from the RF transmitter under power outage conditions will T be possible when the system has been set up this way. Switch : Auto Mode - Apartment plexes, Gated munities, Etc. DIP-Switch : the will automatically open the gate or raise the barrier arm approximately - seconds AFTER loss of AC power occurs. Automatic mode is always used for gates in general access applications such as gated communities, apartment complexes, etc. Automatic mode MUST be used with 0, 0, 0, 00 and 0 operators. Switch : Opening Direction The operator MUST open (Barrier arm goes UP) when power outage occurs. If the operator doesn t open during a power outage, reverse this switch s position. Switch : Restarting AFTER AC Power Has Been Restored DIP-Switch : Automatically Re-keys the gate operator to establish normal operation again. DIP-Switch OFF: Requires a physical input (push button, loop, radio receiver, etc.) BEFORE the gate operator will resume normal operation again. Switch : Using or s Limits for Open Position DIP-Switch : Uses the gate operator S to stop the gate/arm at the open position. For 0, 0, 0, 00 and 0 operators LY. Not for use on 00/00 or 0 operators. DIP-Switch OFF: Uses the R setting ( to secs) to stop the gate at the open position. For 00/00 or 0 operators LY. Not for use on 0, 0, 0, 00 and 0 operators. Description Used for 00/00 or 0 gate operators LY. The run timer sets the amount of time that the operator s DC motor will run after it gets activated by the circuit board. Adjust the run timer so that the gate opens to approximately six inches shy of the full open position and stops. DO T allow the DC motor to run beyond the full open position and slip the operator clutch or stall the DC motor. Damage to the circuit board may result from this. Clockwise adjustment increases the run time, counter-clockwise adjustment decreases the run time. Note: The run timer is not used when the circuit board is installed in the 0, 0, 0, 00 or 0 operators. -0-F--

SPECIFIC GATE OPERATOR INSTALLATI Select YOUR specific gate operator(s) installation on this page or the following pages. 00, 00 Single Swing Gate 00 00 R AC ACT SW -00 0 BATT P Adjust Control Board VAC J Emergency Vehicle Access Dry Contact N.O. Push Button Manual Mode Dry Contact Volt Relay Stand-Alone -Wire Radio Receiver Manual Mode This radio receiver will work during normal daily operation as well as during a power outage. The radio receiver will be powered from the operator s batteries during a power outage. Connect a normally open device to terminals -. This allows another method to open the gate when a power outage occurs if the auto-open mode is T used ( DIP-Switch is OFF). 0 0 0 Single Control Board KEY SWITCH SW SW 0-00 DATA P / DC /OFF will function in either manual or auto open mode ( DIP-Switch ). DIP-Switch MUST be OFF (Timer) and run timer MUST be adjusted. V V / -0-F--

00, 00 Bi-Parting Swing Gate s 00 00 Connect a normally open device to terminals - of the PRIMARY LY. This allows another method to open the gate when a power outage occurs if the auto-open mode is T used ( DIP-Switch is OFF). R AC ACT SW -00 Control Board 0 BATT P Adjust Gray to # - not required if the auto open feature is turned on. VAC J Emergency Vehicle Access Dry Contact N.O. Push Button Manual Mode Dry Contact Volt Relay Chassis Ground Stand-Alone -Wire Radio Receiver Manual Mode This radio receiver will work during normal daily operation as well as during a power outage. The radio receiver will be powered from the operator s batteries during a power outage. Wht Purple 0 0 0 KEY SWITCH SW SW Motor Terminal 0-00 LED LED DATA Control Board / DC /OFF SECDARY operator s board s VAC Input MUST interconnect to PRIMARY main terminals #- & #-. DoorKing Interconnection Cable Sold Separately / V V will function in either manual or auto open mode ( DIP-Switch ). DIP-Switch MUST be OFF (Timer) and run timer MUST be adjusted. R AC ACT SW -00 0 to # - not required if the auto open feature is turned on. Control Board BATT DC /OFF VAC Input Adjust VAC J / / Terminal. RED VAC Motor V. BLUE VAC Motor. WHITE VAC Neutral V Purple. PURPLE VAC. YELLOW VAC. BROWN Pulse. ORANGE mon. GRAY Not Used Optional - Gray See above Chassis Ground -0-F--

00 Single Swing Gate 00 will LY function in auto open mode ( DIP-Switch ). DIP-Switch MUST be (Limit). This allows the to use the 00 s magnetic limit for the gate OPEN position. EXIT P REVERSE POWER Limit Sensors Plug P LMT SECDARY DELAY Single Control Board SW SW PRIMARY 0-00 0 0 0 VAC J P BATT 0-00 AC ACT SW R / / DO T use V V DC /OFF Power Switch -0-F--

00 Bi-Parting Swing Gate s EXIT P REVERSE Chassis Ground Control Board POWER Motor Limit Sensors Plug P Motor LMT Neutral VAC SECDARY Limit DELAY Spare SW PRIMARY Limit Purple 0-00 Gray SW COM 0 -Pin Interface Terminal 0 0 SECDARY operator s board s VAC Input MUST interconnect to PRIMARY main terminals #- & #0-. VAC J P will LY function in auto open mode ( DIP-Switch ). DIP-Switch MUST be (Limit). This allows the to use the 00 s magnetic limit for the gate OPEN position. Control Board 00 DO T use BATT 0 DC /OFF Power Switch / / -00 AC ACT SW V V R Motor Motor Neutral VAC DoorKing Interconnection Cable Sold Separately Terminal Limit Spare Limit COM DO T use BATT -00 AC ACT SW R DC /OFF Chassis Ground Purple Gray VAC J VAC Input P 0 / / V V -0-F--

0 Single Slide Gate 0 VAC Gate Power Terminal Hot Neu R AC ACT SW -00 0 BATT P Adjust VAC J Emergency Vehicle Access Dry Contact N.O. Push Button Manual Mode Dry Contact Volt Relay Stand-Alone -Wire Radio Receiver Manual Mode This radio receiver will work during normal daily operation as well as during a power outage. The radio receiver will be powered from the operator s batteries during a power outage. Connect a normally open device to terminals -. This allows another method to open the gate when a power outage occurs if the auto-open mode is T used ( DIP-Switch is OFF). 0 Single Control Board KEY SWITCH EXIT 0-00 SW SW SW SW / DC /OFF will function in either manual or auto open mode ( DIP-Switch ). DIP-Switch MUST be OFF and run timer MUST be adjusted. V V / -0-F--

0 Bi-Parting Slide Gate s VAC Power Terminal Chassis Ground Hot will function in either manual or auto open mode ( DIP-Switch ). DIP-Switch MUST be OFF and run timer MUST be adjusted. Gray to # - not required if the auto open feature is turned. 0 Control Board / / R AC ACT SW -00 V V 0 BATT DC /OFF V V DC /OFF Power Switch / P Adjust Control Board / R AC ACT SW VAC J Chassis Ground -00 Emergency Vehicle Access Dry Contact N.O. Push Button Manual Mode Dry Contact Volt Relay Stand-Alone -Wire Radio Receiver Manual Mode This radio receiver will work during normal daily operation as well as during a power outage. The radio receiver will be powered from the operator s batteries during a power outage. Connect a normally open device to terminals - of the PRIMARY LY. This allows another method to open the gate when a power outage occurs if the auto-open mode is T used ( DIP-Switch is OFF). Control Board Hot 0 VAC Power Terminal Neu BATT P Adjust Optional - Gray to # See above VAC J Entrapment Protection -Wire Cable Purple Gray # # # # Purple Gray # # # # 0 DoorKing -Wire Interconnection Cable Sold Separately 0 KEY SWITCH 0-00 SW Entrapment Protection Terminal SW KEY SWITCH 0-00 SW Entrapment SW EXIT Control Board Protection Terminal SW EXIT SW -0-F--

0 Single Slide Gate will LY function in auto open mode ( DIP-Switch ). DIP-Switch MUST be (Limit). This allows the to use the 0 s magnetic limit for the gate OPEN position. 0 EXIT LMT REVERSE Connects to OPEN limit or wire, depending on mounting position (open left/open right) of the operator. Wire Limit Wire Limit PRT Limit Sensor Plug POWER 0-00 OPEN DELAY CLOSE Single Control Board 0 0 0 VAC J P R BATT AC ACT SW DO T use -00 Control Board / DC /OFF / V V 0-0-F--

0 Bi-Parting Slide Gate s EXIT LMT REVERSE Connects to OPEN limit or wire, depending on mounting position (open left/open right) of the operator. Wire Limit Wire Limit PRT Limit Sensor Plug 0-00 OPEN DELAY CLOSE Control Board 0 0 will LY function in auto open mode ( DIP-Switch ). DIP-Switch MUST be (Limit). This allows the to use the 0 s magnetic limit for the gate OPEN position. Gray Jumper DoorKing Interconnection Cable Sold Separately / 0 VAC J P 0 Control Board R BATT AC ACT SW DO T use -00 DC /OFF EXIT LMT REVERSE Wire Limit Wire Limit PRT Connects to OPEN limit or wire, depending on mounting position (open left/open right) of the operator. POWER Limit Sensor Plug 0-00 OPEN DELAY CLOSE Control Board 0 0 Gray / / 0 VAC J P / R BATT AC ACT SW V V Control Board DO T use -00 DC /OFF V V -0-F--

0, 0, 0 Single Barrier Gate 00 Control Board DELAY UP 0 P VAC J Factory Installed DC Magnetic Up Limit Sensor N.O. R AC ACT SW BATT 0-00 POWER -00 DO T use Control Board DOWN REVERSE SENSITIVITY 0 / DC /OFF Purple / V V will LY function in auto open mode ( DIP-Switch ). DIP-Switch MUST be (Limit). This allows the to use the 00 s magnetic limit for the arm UP position. -0-F--

0, 0, 0 Bi-Parting Barrier Gate s Control Board DELAY 00 Chassis Ground UP 0 P VAC J Factory Installed DC Magnetic Up Limit Sensor 0-00 POWER R REVERSE SENSITIVITY AC ACT SW BATT N.O. DOWN / / -00 Control Board V V V V DC /OFF DC /OFF / / DO T use Factory Installed DC Magnetic Up Limit Sensor R AC ACT SW -00 will LY function in auto open mode ( DIP-Switch ). DIP-Switch MUST be (Limit). This allows the to use the 00 s magnetic limit for the arm UP position. Chassis Ground Control Board 0 BATT P DO T use VAC J DoorKing Purple Gray Interconnection Cable Sold Separately Purple Gray 0 UP DOWN Control Board 0-00 REVERSE SENSITIVITY POWER DELAY 0-0-F--

Replacement Parts for Convenience Open System Part Number -00 0-00 0-0 00-0- 00-00- 0-00 Quantity Description Control Board Battery, Volt,.0 Amp Hour Toggle Switch Assembly Magnetic Sensor Switch, Barrier s Only Magnet, Barrier s Only V-Belt VAC Cable Harness Battery Volt P/N 0-00 Two () required. Magnetic Sensor Switch P/N 0- Barrier s Only Magnet P/N 00- Barrier s Only VAC J Toggle Switch P/N 0-0 VAC Cable Harness P/N 0-00 0 P BATT -00 R AC ACT SW Control Board P/N -00 V-Belt P/N 00- P/N 00- Control Board Kit P/N - Control board, wire harness and installation manual -0-F--

-0-F--

Installation Manual Use this manual for circuit board -00. Replacement Convenience Open Board For Pre-0 Convenience Open Models: 00, 0, 0, 00, 00, 00, 0 and 0 s LY For Pre-0 Convenience Open s LY -0-F-- Replacement Board for 0-00 Convenience Open Board www.doorking.com DoorKing, Inc. 0 S. Glasgow Avenue Inglewood, California 00 U.S.A. Phone: 0--00 Fax: 0--