Refractive phakic intraocular lenses (IOLs) are being

Similar documents
Behaviour of the phakic iris-claw intraocular lens (Artisan /Verisyse ) during accommodation: An optical coherence biometry study

Technicians & Nurses Program

Causes of refractive error post premium IOL s 3/17/2015. Instruction course: Refining the Refractive Error After Premium IOL s.

Refractive Surgery: Vance Thompson, MD, FACS Refractive Surgeon. Oculeve Wavetec Zeiss Mynosys LRG Equinox Precision Lens ORA Amaken EXCELLens

NOW. Approved for NTIOL classification from CMS Available in Quar ter Diopter Powers. Accommodating. Aberration Free. Aspheric.

Headline. IOLMaster. Subline. The gold standard in biometry

OPTI-201/202 Geometrical and Instrumental Optics Copyright 2018 John E. Greivenkamp. Section 16. The Eye

Section 22. The Eye The Eye. Ciliary Muscle. Sclera. Zonules. Macula And Fovea. Iris. Retina. Pupil. Optical Axis.

Corneal Asphericity and Retinal Image Quality: A Case Study and Simulations

Anterior Chamber Width Measurement by High-Speed Optical Coherence Tomography

Subjective refraction OPTICS OF HUMAN EYE & REFRACTIVE ERRORS

Customized intraocular lenses

THE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening

Corporate Perspective Alcon Unanswered Technical Challenges that Still Need to be Overcome

Surgical data reveals that Q-Factor is important for good surgical outcome

EXCHANGE. Financial Disclosure. Clinical pearls In advanced anterior segment surgery being able to do a IOL exchange is a must. Why Do an Exchange

Product Portfolio. Sulcoflex Pseudophakic Supplementary IOLs

Analysis of intraocular positions of posterior implantable collamer lens by full-scale ultrasound biomicroscopy

Optical Zone Diameters for Photorefractive Corneal Surgery

Dr. Magda Rau Eye Clinic Cham, Germany

User s Guide and Reference Manual

Product Portfolio. Sulcoflex Pseudophakic Supplementary IOLs. Your skill. Our vision.

Crystalens AO: Accommodating, Aberration-Free, Aspheric Y. Ralph Chu, MD Chu Vision Institute Bloomington, MN

case report Scleral lens fit based on OCT data

LASIK & Refractive Surgery

IOL Types. Hazem Elbedewy. M.D., FRCS (Glasg.) Lecturer of Ophthalmology Tanta university

THE XTRAFOCUS IS AN ELEGANT SOLUTION TO COMPLEX CASES.

By Dr. Abdelaziz Hussein

10/25/2017. Financial Disclosures. Do your patients complain of? Are you frustrated by remake after remake? What is wavefront error (WFE)?

Sutureless, Glueless, Scleral Fixation of Single-Piece and Toric Intraocular Lens: A Novel Technique

Retinal stray light originating from intraocular lenses and its effect on visual performance van der Mooren, Marie Huibert

The Dysphotopsia Mystery. John J. Bussa, M.D.

Patient information. Your options for cataract treatment Enjoy clear vision at all distances with multifocal IOLs

Roadmap to presbyopic success

*Simulated vision. **Individual results may vary and are not guaranteed. Visual Performance When It s Needed Most

Sulcoflex. For when perfection is the only option! Pseudophakic Sulcus Fixated Secondary IOLs. Sulcoflex Aspheric. Sulcoflex Toric

Choosing the Proper Power for the IOL. Brannon Aden, MD Miles H. Friedlander, MD, FACS

AHEAD Superior technology, thoughtfully designed with you in mind for an intelligent approach to cataract surgery.

HIGH DEFINITION VISION SOLUTIONS THE COMPLETE GUIDE TO LASER VISION CO R R EC T I O N

Unique Aberration-Free IOL: A Vision that Patients

Treatment of Presbyopia during Crystalline Lens Surgery A Review

DEFECTS OF VISION THROUGH APHAKIC SPECTACLE LENSES*t

Choices and Vision. Jeffrey Koziol M.D. Thursday, December 6, 12

Improving Lifestyle Vision. with Small Aperture Optics

Trust your eyes. Presbyopic treatment methods on the cornea. PresbyMAX Decision criteria and patient s acceptance

Optical Biometer. AL-Scan. US Edition

Multifocal Intraocular Lenses for the Treatment of Presbyopia: Benefits and Side-effects

Table of contents. 5 Swiss precision for clear vision. 6 What types of defective eyesight are there? 8 What is refractive eye surgery?

Rediscover quality of life thanks to vision correction with technology from Carl Zeiss. Patient Information

New Materials for Perfect Vision

Wave Front Topography. ReSeeVit Evolution Topography Module for Modi Topographer

OpenStax-CNX module: m Vision Correction * OpenStax

OCULUS Pentacam AXL Always an Axial Length Ahead

Visian implantable contact lens versus AcrySof Cachet phakic intraocular lenses: comparison of aberrmetric profiles

Fitting Manual Use with kerasofttraining.com

ABO Certification Training. Part I: Anatomy and Physiology

Visual Outcomes of Two Aspheric PCIOLs: Tecnis Z9000 versus Akreos AO

Subjective refraction

Diagnostic Technologies for Enhanced Cataract Surgery Outcomes

Maximising Treatment Outcomes with Premium IOL Technology. Saturday 13 September 2014 XXXII Congress of the ESCRS London, UK.

ROTATIONAL STABILITY MAKES THE DIFFERENCE

Optical Biometer AL-Scan

Vision Shaping Treatment

Evaluate Your Patient s Total Visual System With the OPD-Scan III

Modulation transfer function: Rigid versus foldable phakic intraocular lenses

Soft CL Multifocals Design and Fitting. Soft Multifocal Lens Designs. Issues Surrounding Multifocals. Blur Interpretation. Simultaneous Vision Designs

Improving outcomes LENSTAR LS 900. Biometry

THE ASPHERIC PRELOADED INJECTION

Clinical Update for Presbyopic Lens Options

Optical Biometer AL-Scan

The complete choice in refractive lens solutions

Clinical Evaluation 3-month Follow-up Report

Choices and Vision. Jeffrey Koziol M.D. Friday, December 7, 12

Intraocular lens Difficulties

Optics of the crystalline lens and accommodative response

4/2/2015. Bonnie An Henderson MD Clinical Professor of Ophthalmology Tufts University School of Medicine Ophthalmic Consultants of Boston

The design is distinctive. The outcomes are clear. Defocus tolerance 1 Glistening-free performance 1,2 Predictable outcomes 1

Goldmann Visual Field. Humphrey Visual Field 4/25/2017. What s So Special About Special Testing?! Houston, we have a problem.

Accommodating IOL s History and Clinical Management

Maximum Light Transmission. Pupil-independent Light Distribution. 3.75D Near Addition Improved Intermediate Vision

In this issue of the Journal, Oliver and colleagues

EP A1 (19) (11) EP A1 (12) EUROPEAN PATENT APPLICATION. (43) Date of publication: Bulletin 2010/16

EYE-REFRACTIVE ERRORS

What s New in Ocular Biomechanics?

Technicians & Nurses Program

Advanced Technology IOLs

(12) Patent Application Publication (10) Pub. No.: US 2016/ A1

Refractive Power / Corneal Analyzer. OPD-Scan III

FOR PRECISE ASTIGMATISM CORRECTION.

Principles and clinical applications of ray-tracing aberrometry (Part II)

Please feel to contact Sonomed for any suggestions, comments or request about this bulletin.

Assessing Visual Quality With the Point Spread Function Using the NIDEK OPD-Scan II

What you should know about LASIK and Femto-LASIK Understanding Laser Vision Correction. Patient information

Optical Biometer AL-Scan

Colvard Pupillometer Measurement of Scotopic Pupil Diameter in Emmetropes and Myopes

Cataract Information. victoriaeye.com

3. Study the diagram given below and answer the questions that follow it:

MEASUREMENTS OF THE SAGITTAL AXIS OF THE HUMAN

SEE BEYOND WITH FULLRANGE OPTICS. Developed by Hanita Lenses

(12) Patent Application Publication (10) Pub. No.: US 2004/ A1

Transcription:

case reports Contact between 3 phakic intraocular lens models and the crystalline lens: An anterior chamber optical coherence tomography study Georges Baikoff, MD, Eric Lutun, Jay Wei, Caroline Ferraz, MD Three phakic intraocular lens (IOL) models were implanted in 3 different patients. With the usual slitlamp examination, it was not possible to determine whether there was contact between the IOLs and the natural crystalline lens. Using the anterior chamber optical coherence tomography (AC OCT) scanner, direct contact between the natural crystalline lens and the 3 phakic IOLs was revealed. A dynamic study of the contact was performed during accommodation. These observations show that examination of the anterior segment with the AC OCT scanner provides new data about the status of the anterior segment after implantation of phakic IOLs. J Cataract Refract Surg 2004; 30:2007 2012 2004 ASCRS and ESCRS Refractive phakic intraocular lenses (IOLs) are being used more frequently to correct high ametropia and/or associated astigmatism. Three models are available: angle-supported anterior chamber (AC) IOLs (ZB, ZB5M, NuVita [Bausch & Lomb]; GBR [Ioltech]; Vivarte [Ciba Vision]); iris-fixated AC IOLs (iris claw, Artisan /Verisyse [Ophtec]); and posterior chamber (PC) IOLs (ICL [Staar Surgical], PRL [Medennium]). Refractive IOLs were introduced because of the limitations of laser in situ keratomileusis (LASIK) and better understanding of how the cornea reacts to surgery (eg, post-radial keratotomy hyperopia, post-lasik keratectasia, haze, regression, dry eyes, and optical aberrations). Accepted for publication February 23, 2004. From Clinique Monticelli (Baikoff, Lutun, Ferraz), Marseille, France, and Carl Zeiss Meditec (Wei), Dublin, California, USA. Mr. Wei was employed by Carl Zeiss Meditec. None of the other authors has a financial or proprietary interest in any material or method mentioned. Supported by Carl Zeiss Meditec. Reprint requests to Georges Baikoff, MD, Clinique Monticelli, 88, rue du Commandant Rolland, 13008 Marseille, France. E-mail: g.baik. opht@wanadoo.fr. Knowledge of anterior segment physiology (endothelium, biomaterial tolerance) has improved IOL toler- ance. Today, AC IOLs induce few or no cataracts and do not endanger the natural crystalline lens. The most important development in the design of these IOLs is related to the endothelial safety factor. Reports of extensive corneal edema secondary to phakic IOL surgery have almost disappeared from recent literature. However, even if PC IOLs do not appear to damage the corneal endothelium, numerous questions about the state of the crystalline lens at midterm and long term remain unanswered. We studied the way 3 phakic IOL models came in contact with the natural crystalline lens. With 2 models, we were unable to produce evidence of contact using standard examination methods. However, contact was visible using a new device, the AC optical coherence tomography device (OCT) scanner. The AC OCT scanner is described in a related article in this issue. 1 Interest in the device lies in its micron-scale resolution (10 m) and its ability to capture the entire anterior segment in 1 step. The operator can choose to scan the horizontal, vertical, or oblique diameter of the anterior segment. This device is different 2004 ASCRS and ESCRS 0886-3350/04/$ see front matter Published by Elsevier Inc. doi:10.1016/j.jcrs.2004.05.018

from other OCT devices that have been described. 2 4 Case 2 Once the image is taken, the device s software restores Within 1 week, a 10.00 D PRL was implanted in the image to its real dimensions, avoiding the errors both eyes of a 24-year-old patient to correct high hyperopia. induced by differences in ray transmission through the The preoperative visual acuity was 0.8 with 11.0 D; the ACD was 3.40 mm (IOLMaster). The IOP was 14 mm Hg cornea. Specific software can measure the distance beand the endothelial cell count, 3000 cells/mm 2. Two weeks tween 2 points the curvature radius and the angles. after surgery, the UCVA was 0.5, the residual spherical equivalent (SE) refraction was 1.00 D, and the IOP was Case Reports 14 mm Hg. The position of the PRL was studied clinically with a slitlamp and the AC OCT tomographer. With the Case 1 slitlamp and an undilated pupil, it was impossible to see whether there was contact between the PRL and the natural In March 2003, a 25-year-old woman presented with crystalline lens. After dilation, it appeared there might be hyperopia of 5.00 diopters (D) in the right eye. A 7.00 D contact between the PRL edges and the crystalline lens near Artisan IOL was implanted in the right eye, with the IOL the pupil margin. In images taken with the AC OCT scanner, fixated in the horizontal axis of the iris. The patient had an the edges of the PRL optic were seen to touch the crystalline uncorrected visual acuity (UCVA) of 0.9 postoperatively, lens (Figure 4). with a residual refraction of 0.75 D. The intraocular presdynamic As in the first case, the patient was reexamined and a sure (IOP) and cell count were normal. The preoperative study of the relationship between the PRL and the anterior chamber depth (ACD) was 3.31 mm (IOLMaster, crystalline lens during accommodation was performed. Pupil Carl Zeiss Meditec). At the last examination, the endothelial contraction was observed concurrent with accommodation cell count was 3000 cells/mm 2 (the same as preoperatively). and forward steepening and bulging of the crystalline lens During a recent postoperative examination, a complete anterior pole (Figures 5 and 6). In the unaccommodated anterior segment examination was performed with and with- state, there was a space between the posterior surface of the out dilation. After pupil dilation, biomicroscopy seemed to IOL and the anterior pole of the crystalline lens; this space indicate a tilt of the Artisan IOL, which appeared to pivot was largest at the center of the PRL. It seemed to decrease around the horizontal axis under the influence of gravity. toward the periphery, which is hidden by the iris. In the The lower edge of the IOL appeared extremely close to and accommodated state, the entire posterior surface of the PRL was visible in the pupil area and was in direct contact with possibly in contact with the crystalline lens. The anterior the crystalline lens. This indicated that during efforts to segment was then photographed in the vertical plane in myaccommodate, as a result of zonular slackening and steepening driatic conditions with the AC OCT scanner. This showed of the crystalline lens anterior curvature, the forward movethe lower part of the IOL was slightly oblique posteriorly ment of the anterior pole caused contact. To date, the crystaland was in contact with the crystalline lens (Figure 1). This line lens remains clear. can be explained by the tilting of the Artisan IOL around the horizontal axis, which was the fixation axis. When the Case 3 pupil is not dilated, the crystalline lens is protected by the In 1993, a ZB5M refractive AC IOL was implanted in iris tissue, which comes between the IOL and the anterior a 30-year-old woman to treat unilateral high myopia. The surface of the crystalline lens. preoperative best corrected visual acuity in the left eye was The patient was reevaluated a few days later with a 0.7 with a refraction of 12.0 D. The patient was seen dynamic examination of the anterior segment. Pictures of every year to monitor the corneal endothelium. Ten years the unaccommodated (Figure 2) and accommodated (Figure after implantation, the UCVA was 0.4, the residual SE refrac- 3) eye were taken. The natural movement of the crystalline tion was 2.00 D, and the IOP was 14 mm Hg. The angle lens was observed, with a forward bulge of the anterior pole was normal with no synechias, the pupil was round, and the of approximately 268 m for 7.00 D of accommodation. mean endothelial cell density was 2000 cells/mm 2. For the During accommodation, the crystalline lens came extremely first time, the slitlamp examination showed possible contact close to the posterior face of the IOL. During this natural between the crystalline lens and the posterior surface of the accommodation, unexpected pupil movement that showed IOL optic in the pupil area. Examination with the AC OCT no accommodative miosis was noted (Figures 2 and 3). Under scanner was performed without dilation. Since this patient examination conditions, the space between the anterior sur- was 40 years old, the dynamics of accommodation were not face of the IOL and the natural crystalline lens was consider- studied as the images from the unaccommodated eye were ably reduced and it was easy to see the inclination of the sufficiently conclusive. Contact between the posterior surface IOL relative to the anterior curvature of the crystalline lens. of the IOL optic and the central part of the natural lens was The crystalline lens is currently clear. confirmed (Figure 7). There is no cataract to date. 2008 J CATARACT REFRACT SURG VOL 30, SEPTEMBER 2004

Figure 1. (Baikoff) Vertical profile of an Figure 2. (Baikoff) The ACD (posterior Figure 3. (Baikoff) The ACD of the eye in Artisan IOL after mydriatic contact on the 6 face of the cornea to anterior face of crystal- Figure 1 (accommodated) was 2.518 mm. o clock meridian between the crystalline lens line lens) in the eye in Figure 1 (unaccommoand the posterior IOL surface. dated) with an Artisan IOL was 2.786 mm. Figure 4. (Baikoff) After dilation, the edges of the PRL are in con- Figure 5. (Baikoff) The PRL in the eye in Figure 4 tact with the crystalline lens. (unaccommodated). Figure 6. (Baikoff) The PRL in the eye in Figure 4 with 12.0 D of Figure 7. (Baikoff) The ZB5M IOL 10 years after implantation. accommodation; the anterior surface of the crystalline lens touches There is contact between the anterior face of the crystalline lens and the IOL. the posterior face of the phakic IOL. J CATARACT REFRACT SURG VOL 30, SEPTEMBER 2004 2009

Discussion IOL and the anterior capsule of the crystalline lens. When the subject accommodates, which happens constantly in everyday life, the anterior pole of the crystalline lens is pushed forward under recurrent modifications of the anterior segment and comes in contact with the poste- rior surface of the PRL. The question is whether, in the long term, this intermittent but repetitive contact is dangerous to the natural crystalline lens of a young subject. Anterior Segment Examination of Refractive Phakic IOL Candidates Today, anatomical inclusion criteria for a refractive phakic IOL rest essentially on the quality of the endo- thelium, the ACD, an open angle, and the white-to- white diameter. The endothelium is easily evaluated with the specular microscope; the angle opening can be analyzed clinically by gonioscopy; and the ACD (generally considered the distance between the corneal epithelium and the anterior surface of the crystalline lens) is measured without difficulty by A-scan, B-scan, or ultrasound biomicroscopy (UBM). Optical systems such as the IOLMaster are also routinely used. However, these measures are static and are performed in an unac- commodated eye; the ACD and its variations during accommodation cannot be evaluated. The AC OCT scanner offers something new: First, because it is a noncontact examination, it is simple and rapid. Second, by focusing or defocusing with positive or negative lenses, it is possible to relax or stimulate the subject s accommodation in a natural way. Consid- ering our observations in Cases 1 and 2, this dynamic study will become essential because no one imagined the crystalline lens could come in contact with the posterior surface of a phakic AC IOL during accommo- dation. We had doubts concerning PC IOLs, but we now have proof that a genuine risk exists. The technique used with the 1310 nm OCT prototype gives a much better image than the 820 nm OCT used for the poste- rior segment. 14 Various white-to-white methods are used to evalu- ate the internal diameter of the AC. Ultra-high-frequency UBM devices 12 offer excellent images. The progress made in lower-frequency UBM scans is equally significant, but in our experience, no equipment other than the AC OCT tomographer allows visualization of the diameter of the AC simply and with such precision. These 3 cases raise the following issues: the risk for induced cataract after refractive lens surgery in a phakic eye, the importance of developing new technologies to explore the anterior segment, and the need for new inclusion criteria for refractive phakic IOLs. Risk for Induced Cataract After Refractive Phakic IOL Implantation The ZB, ZB5M, and NuVita IOLs are not known to induce cataracts. During a multicenter study performed by Baikoff et al., 5 the cataract rate was extremely low. Alió and coauthors 6 report 9 cases of cataract that occurred in extremely myopic eyes with axial lengths greater than 30.0 mm. It is well known that highly myopic patients have a greater risk for spontaneous cataract development than the normal population. In- troducing a foreign body into the AC may modify the metabolism of the crystalline lens. Nevertheless, AC IOLs are not considered an important contributing factor to cataracts in a population already at risk (highly myopic patients). An increase in crystalline lens thick- ness from aging should be considered and the patient informed of this possibility. Iris-claw IOLs 7 9 are not considered more cataract inducing than angle-supported IOLs. However, it is different with PC IOLs, especially the ICL. Zaldivar and coauthors 10 demonstrate that during successive modifications of the lens, the V3 model induced a number of cataracts that increased with time. Gonvers and coauthors 11 report that with the ICL, the increase in cataracts seems proportionate to age. A 20-year-old patient has a low risk for developing cataract; a 40 year old runs a higher risk. The ICL generally rests in the iridociliary sulcus, and the vault was modified in later generations of the lens. Today, a higher vault is recommended to maintain sufficient space between the posterior surface of the ICL and the crystalline lens to reduce the risk for cataract. The PRL is also placed in the PC. It is made of silicone and floats in the PC without touching the ciliary sulcus. Some images of myopic PRLs show signifi- cant space between the posterior surface and the crystal- line lens. 12 The cataract rate after PRL IOL implantation appears to be less than 2%. 13 However, in 1 hyperopic case, observation showed that if the eye is undilated when the examination is done, there is a space between the 2010 J CATARACT REFRACT SURG VOL 30, SEPTEMBER 2004

Figure 8. (Baikoff) Evolution of the ACD relative to age. The relationship between the internal diameter and the AC IOL must be studied separately. CASE REPORTS: BAIKOFF between the position of the IOL and the crystalline lens relative to theoretical aging and modifications of the AC with age. Conclusions These 3 cases establish the possibility that contact between a refractive phakic IOL and the crystalline lens is not always well detected with the slitlamp (or biomicroscopy). The AC OCT is a better tool to ascertain whether such contact exists. This means we can evoke accommodative trauma as a cause of cataract in subjects with phakic IOLs; in particular, subjects with PC phakic IOLs, in whom contact between the posterior surface of the IOL and the crystalline lens is more frequent than we imagined from the recurrent accommodative movements of a young subject in everyday life. This study recommends extending the safety criteria for implanting refractive phakic IOLs in young subjects. As soon as new examination procedures such as the AC OCT tomographer are available, it will be vital to carry out a dynamic examination and simulate aging in an eye with a refractive IOL. A simple way of describing the problem is that the phakic IOL is going to hang out in the anterior segment and it is essential to know whether this hanging out will be safe and for how long. Our observations have to be confirmed by other refractive surgery centers, but reporting these analyses provides new perspectives on refractive phakic IOLs. In our opinion, the AC OCT tomographer or similar equipment should become as necessary for phakic IOL implantation as topography is for corneal refractive surgery. New Inclusion Criteria for Refractive IOLs The 3 observations reported here are crucial. The ACD, open angle, endothelial cell density, and whiteto-white diameter are considered essential implantation criteria today, but in the light of our observations, they appear insufficient. It is urgent and advisable that surgeons have more advanced technologies such as the AC OCT tomographer, which seems to be a significant advancement because of its simplicity. We suggest that the software of anterior segment examination systems include the dimensions and profiles of different refractive IOL models, with visualization of the different powers. This allows us to preoperatively superimpose the selected IOL on the image of the patient s anterior segment. If safety criteria are not met (eg, a safe distance between the endothelium and the IOL, the posterior surface of the IOL and the iris, and the posterior surface of the IOL and the crystalline lens), the model will have to be changed or implantation not performed. Moreover, it will be possible to simulate the position of an IOL in the eye and know in advance its position during accommoda- References 1. Baikoff G, Lutun E, Ferraz C, Wei J. Static and dynamic tion. Statistical studies of AC OCT observations of the analysis of the anterior segment with optical coherence anatomical modifications of the anterior segment during tomography. J Cataract Refract Surg 2004; 30:1843 accommodation and aging are described in a related 1850 article in this issue. 1 The statistical studies of the forward 2. Wirbelauer C, Winkler J, Scholz C, et al. Experimental movement of the crystalline lens anterior pole relative to imaging of intracorneal ring segments with optical coher- accommodation (see Figure 11 1 ), the maximum forward ence tomography. J Refract Surg 2003; 19:367 371 movement of the crystalline lens anterior pole relative 3. Wirbelauer C, Pham DT. Intraoperative optical coher- ence pachymetry during laser in situ keratomileuto age (see Figure 12 1 ), and the ACD relative to age sis first clinical experience. J Refract Surg 2003; 19: (Figure 8) should be integrated into the software to carry 372 377 out static and dynamic simulations of the IOL position 4. Wirbelauer C, Karandish A, Aurich H, Pham DT. Imaging scleral expansion bands for presbyopia with in a young subject and then simulate the relationship optical J CATARACT REFRACT SURG VOL 30, SEPTEMBER 2004 2011

coherence tomography. J Cataract Refract Surg 2003; 10. Zaldivar R, Davidorf JM, Oscherow S. Posterior chamber 29:2435 2438 phakic intraocular lens for myopia of 8 to 18 5. Baikoff G, Arne JL, Bokobza Y, et al. Angle-fixated diopters. J Refract Surg 1998; 14:294 305 anterior chamber phakic intraocular lens for myopia of 11. Gonvers M, Bornet C, Othenin-Girard P. Implantable 7 to 19 diopters. J Refract Surg 1998; 14:282 293 contact lens for moderate to high myopia; relationship 6. Alió JL, de la Hoz F, Ruiz Moreno JM, Salem TF. of vaulting to cataract formation. J Cataract Refract Surg Cataract surgery in highly myopic eyes corrected by 2003; 29:918 924 phakic anterior chamber angle-supported lenses. J Cataract 12. Kim DY, Reinstein DZ, Silverman RH, et al. Very high Refract Surg 2000; 26:1303 1311 frequency ultrasound analysis of a new phakic posterior 7. Landesz M, Worst JGF, Van Rij G. Long-term results chamber intraocular lens in situ. Am J Ophthalmol of correction of high myopia with an iris claw phakic 1998; 125:725 729 intraocular lens. J Refract Surg 2000; 16:310 316 13. Hoyos JE, Dementiev DD, Cigales M, et al. Phakic 8. Menezo JL, Aviño JA, Cisneros A, et al. Iris claw phakic refractive lens experience in Spain. J Cataract Refract intraocular lens for high myopia. J Refract Surg 1997; Surg 2002; 28:1939 1946 13:545 555 14. Bechmann M, Ullrich S, Thiel MJ, et al. Imaging of 9. Alió JL, Mulet ME, Shalaby AMM. Artisan phakic iris posterior chamber phakic intraocular lens by optical coclaw intraocular lens for high primary and secondary herence tomography. J Cataract Refract Surg 2002; 28: hyperopia. J Refract Surg 2002; 18:697 707 360 363 2012 J CATARACT REFRACT SURG VOL 30, SEPTEMBER 2004