Optical Performance of Nikon F-Mount Lenses. Landon Carter May 11, Measurement and Instrumentation

Similar documents
Optical design of a high resolution vision lens

OPTICAL IMAGE FORMATION

Determining MTF with a Slant Edge Target ABSTRACT AND INTRODUCTION

Defense Technical Information Center Compilation Part Notice

A Study of Slanted-Edge MTF Stability and Repeatability

Criteria for Optical Systems: Optical Path Difference How do we determine the quality of a lens system? Several criteria used in optical design

Be aware that there is no universal notation for the various quantities.

Fast MTF measurement of CMOS imagers using ISO slantededge methodology

Measurement of the Modulation Transfer Function (MTF) of a camera lens. Laboratoire d Enseignement Expérimental (LEnsE)

Point Spread Function Estimation Tool, Alpha Version. A Plugin for ImageJ

This experiment is under development and thus we appreciate any and all comments as we design an interesting and achievable set of goals.

Implementation of Adaptive Coded Aperture Imaging using a Digital Micro-Mirror Device for Defocus Deblurring

PROCEEDINGS OF SPIE. Measurement of the modulation transfer function (MTF) of a camera lens

TECHSPEC COMPACT FIXED FOCAL LENGTH LENS

Imaging Optics Fundamentals

On spatial resolution

ECEN 4606, UNDERGRADUATE OPTICS LAB

Sharpness, Resolution and Interpolation

Bias errors in PIV: the pixel locking effect revisited.

IMAGE SENSOR SOLUTIONS. KAC-96-1/5" Lens Kit. KODAK KAC-96-1/5" Lens Kit. for use with the KODAK CMOS Image Sensors. November 2004 Revision 2

Examination, TEN1, in courses SK2500/SK2501, Physics of Biomedical Microscopy,

MINIATURE X-RAY SOURCES AND THE EFFECTS OF SPOT SIZE ON SYSTEM PERFORMANCE

EE-527: MicroFabrication

ABOUT RESOLUTION. pco.knowledge base

Εισαγωγική στην Οπτική Απεικόνιση

Modulation Transfer Function

Astronomical Cameras

Correlation of mid-spatial features to image performance in aspheric mirrors

Optical Coherence: Recreation of the Experiment of Thompson and Wolf

Some of the important topics needed to be addressed in a successful lens design project (R.R. Shannon: The Art and Science of Optical Design)

FRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION

ISO INTERNATIONAL STANDARD. Photography Electronic still-picture cameras Resolution measurements

Focus-Aid Signal for Super Hi-Vision Cameras

BASLER A601f / A602f

Advanced Camera and Image Sensor Technology. Steve Kinney Imaging Professional Camera Link Chairman

EMVA1288 compliant Interpolation Algorithm

E X P E R I M E N T 12

ME 297 L4-2 Optical design flow Analysis

Evaluating Commercial Scanners for Astronomical Images. The underlying technology of the scanners: Pixel sizes:

Variable microinspection system. system125

The Formation of an Aerial Image, part 3

Application Note #548 AcuityXR Technology Significantly Enhances Lateral Resolution of White-Light Optical Profilers

BIG PIXELS VS. SMALL PIXELS THE OPTICAL BOTTLENECK. Gregory Hollows Edmund Optics

Reikan FoCal Aperture Sharpness Test Report

Katarina Logg, Kristofer Bodvard, Mikael Käll. Dept. of Applied Physics. 12 September Optical Microscopy. Supervisor s signature:...

Testing Aspheric Lenses: New Approaches

Performance Factors. Technical Assistance. Fundamental Optics

Tech Paper. Anti-Sparkle Film Distinctness of Image Characterization

Photons and solid state detection

ECEN 4606, UNDERGRADUATE OPTICS LAB

Bioimage Informatics

Practical Flatness Tech Note

LCD handheld displays characterization by means of the MTF measurement

Fourier transforms, SIM

Modulation Transfer Function

VISUAL PHYSICS ONLINE DEPTH STUDY: ELECTRON MICROSCOPES

Nikon AF-S Nikkor 50mm F1.4G Lens Review: 4. Test results (FX): Digital Photograph...

Reducing Proximity Effects in Optical Lithography

Reikan FoCal Aperture Sharpness Test Report

New foveated wide angle lens with high resolving power and without brightness loss in the periphery

digital film technology Resolution Matters what's in a pattern white paper standing the test of time

Optical and mechanical parameters. 100 mm N. of elements 20.5 mm Dimensions 11.7 degrees Weight F/N = 4 (fixed) N.A.

Topic 6 - Optics Depth of Field and Circle Of Confusion

Using Optics to Optimize Your Machine Vision Application

MICRO AND NANOPROCESSING TECHNOLOGIES

OPAC 202 Optical Design and Instrumentation. Topic 3 Review Of Geometrical and Wave Optics. Department of

Low Contrast Dielectric Metasurface Optics. Arka Majumdar 1,2,+ 8 pages, 4 figures S1-S4

Optical basics for machine vision systems. Lars Fermum Chief instructor STEMMER IMAGING GmbH

TSBB09 Image Sensors 2018-HT2. Image Formation Part 1

Lecture Notes 10 Image Sensor Optics. Imaging optics. Pixel optics. Microlens

Reikan FoCal Aperture Sharpness Test Report

Nikon. King s College London. Imaging Centre. N-SIM guide NIKON IMAGING KING S COLLEGE LONDON

OCT Spectrometer Design Understanding roll-off to achieve the clearest images

EE119 Introduction to Optical Engineering Spring 2003 Final Exam. Name:

GEOMETRICAL OPTICS Practical 1. Part I. BASIC ELEMENTS AND METHODS FOR CHARACTERIZATION OF OPTICAL SYSTEMS

1.Discuss the frequency domain techniques of image enhancement in detail.

Nikon 200mm f/4d ED-IF AF Micro Nikkor (Tested)

Supplementary Figure 1. Effect of the spacer thickness on the resonance properties of the gold and silver metasurface layers.

Vocabulary: Description: Materials: Objectives: Safety: Two 45-minute class periods (one for background and one for activity) Schedule:

Table of Contents. 1. High-Resolution Images with the D800E Aperture and Complex Subjects Color Aliasing and Moiré...

Imaging Particle Analysis: The Importance of Image Quality

Refractive index homogeneity TWE effect on large aperture optical systems

An Evaluation of MTF Determination Methods for 35mm Film Scanners

CODE V Introductory Tutorial

On the rendering of synthetic images with specific point spread functions F. van den Bergh

Reikan FoCal Aperture Sharpness Test Report

Reikan FoCal Fully Automatic Test Report

SUPPLEMENTARY INFORMATION

The predicted performance of the ACS coronagraph

Fabrication of Probes for High Resolution Optical Microscopy

Design Description Document

Chapters 1 & 2. Definitions and applications Conceptual basis of photogrammetric processing

OPTICAL SYSTEMS OBJECTIVES

Applications of Optics

Measurement of Temperature, Soot Diameter and Soot Volume Fraction in a Gulder Burner

ELEC Dr Reji Mathew Electrical Engineering UNSW

Nikon Instruments Europe

ILLUMINATION AND IMAGE PROCESSING FOR REAL-TIME CONTROL OF DIRECTED ENERGY DEPOSITION ADDITIVE MANUFACTURING

IMAGE FORMATION. Light source properties. Sensor characteristics Surface. Surface reflectance properties. Optics

Technical Guide Technical Guide

Transcription:

Optical Performance of Nikon F-Mount Lenses Landon Carter May 11, 2016 2.671 Measurement and Instrumentation

Abstract In photographic systems, lenses are one of the most important pieces of the system towards determining whole-system performance. Recently, lens resolution has been superseded by sensor resolution as Moore s law drives the transistors and pixels smaller and smaller, making lens resolution the limiting factor as modern photographic lenses struggle to resolve the 5 m pixels of modern sensors. Lens performance is typically not reported in enough detail - notably, most lens data does not include data for multiple apertures, but aperture can have a huge effect on lens resolution. In order to study lens performance, a specialized superresolution sensor was used to directly measure lens s optical characteristics by resolving the step function of the lens and deriving the transfer function. So far, lens performance has been ascertained for one lens and matches published values, while also providing a far more complete view of the lens performance characteristics through a full transfer function determination at every aperture, showing that this novel method can be applied successfully towards lens performance testing. 1 Introduction Lens performance is not perfect - lens designers need to make choices when considering the design, including complexity, cost optimization, weight, size, material properties, and tolerances. All of these can lead to lenses with sub-optimal performance, and in fact, designing a perfect lens is essentially impossible. Many manufacturers, including Nikon, publish some sort of lens data. This is typically presented in an MTF (Modulation Transfer Function) chart. Unfortunately, these MTFs typically present a very limited view of lens performance, usually only specifying performance at one (usually unspecified) aperture, and two spatial frequencies (typically 10 and 30 lp/mm), while we really desire the lens performance at all apertures and showing the performance at spatial frequencies that are useful for modern sensors (at least 50 lp/mm). Knowing performance at all apertures is especially important, because two different factors can affect performance at different apertures - manufacturing and design flaws, which dominate at wide apertures, and diffraction limit, which dominates at small apertures. In order to fill in the missing information regarding the full range of aperture values and extending the performance information out to the spatial resolutions that match modern sensors, new measurement methods must be employed - rather than simply imaging resolution targets, we can image a step function and examine the transfer function through a bit of math - the theory behind this will be covered in more detail in the background section. 2 Background 2.1 Lens Basics Lenses are composed of different elements - individual pieces of glass that are arranged very precisely to achieve the total lens performance. In Figure 1 (Nikon), the elements are white. Lenses also contain an aperture, which serves to decrease the amount of light that 1 Landon Carter May 11, 2016

is let through a lens, by forcing it through a smaller or larger hole. This is illustrated in Figure 2 (PixeLarge). Fig. 1: Lens diagram for Nikon 50mm f/1.8d lens. (Nikon) Fig. 2: Various aperture sizes, showing relationship between photographic aperture and opening diameter. (PixeLarge) The MTF shows the gain of selected spatial frequencies and orientations across the radial axis of the lens, measured as mm across a standard sensor size (which sits a standard distance from the back of the lens). An example MTF for the Nikon 50mm f/1.8d is shown in Figure 3 (Nikon). A graphic detailing the difference between sagital and meridonial traces is in Figure 4 (Nikon). We see that the gain at 30 lp/mm is about 0.6, and decreases as we move away from the center of the lens. Though this data is useful, it only presents data at two specific spatial frequencies and does not present data at different apertures. In particular, many MTF s are specified at 30 lp/mm, while modern sensors can resolve better than 50 lp/mm of spatial resolution, leaving us unsure of how much the lens is handicapping the system. In general, lenses can be thought of as optical low-pass filters, given spatial frequencies, so knowing the performance at 30 lp/mm, we can only extrapolate that the performance at 50 lp/mm will be worse. Unfortunately, it is not really possible to guess the shape of the transfer function based off of two points. 2 Landon Carter May 11, 2016

Fig. 3: Nikon s published MTF for the Nikon 50mm f/1.8d lens. Note that only 10 and 30 lp/mm are represented, and aperture is not specified. (Nikon) Fig. 4: Diagram illustrating the difference between sagital and meridonial lines in the MTF chart. (Nikon) Finally, the effect of aperture on lens performance must be mentioned. At smaller apertures (higher numerical apertures), depth of field improves, but the diffraction limit is reached. The diffraction limit is the highest resolution that any optical system can achieve, given by the aperture and wavelength of light. This fundamental limit can only be surpassed by specialized techniques such as interferometric microscopy, near-field microscopy, and other specialized microscopy techniques. The diffraction limit is given as d = λ 2NA Where d is the radius of the smallest circle a point of light can be focused to, λ is the wavelength of light, and N A is the numeric aperture, where the photographic aperture is 1/(2 NA). The diffraction limit sets a gold standard for lenses - the perfect lens will be diffraction limited at all apertures. In reality, most lenses are diffraction limited at apertures smaller than about f/4 through f/16, depending on the lens. This brings us to the crux of this research - measuring a lens ultimate resolving power, and determining at what aperture this occurs. 2.2 Theoretical Background In order to understand how to measure a lens ultimate resolving power, we must first discuss the Point Spread Function (PSF), Line Spread Function (LSF), Edge Spread Function (ESF), and Optical Transfer Function (OTF). The MTF is the absolute value of the complex-valued OTF, and does not include information on phase shift that is contained within the OTF. The PSF is the response to a 2-dimensional impulse - a point of light. As with all systems, the Fourier Transform of the system s impulse response is the system s transfer function. In this case, taking a 2D Fourier Transform of the PSF gives the OTF, from which the absolute value can be taken to obtain the MTF. However, getting a point source of light small enough (1) 3 Landon Carter May 11, 2016

to be considered a point is difficult - at a focused distance of 1m, this point would have to be about 200 µm across. Instead, it is easier to image a black square next to a white square - a step function input, whose response is the ESF. From there, you can take the derivative of the ESF to obtain the LSF, the 1-dimensional analog of the PSF. As such, the Fourier Transform can be taken to reveal the 1-dimensional OTF. If the lens can be assumed to be radially symmetric, which is an assumption we will make, this is just a slice from the symmetric 2D OTF, and can thus be used to compute the 2D OTF. This series of relationships is summarized in Figure 5 (Schowengerdt [2000]). Fig. 5: Diagram describing the relationships between various functions and responses relevant to lens performance. In this research, we will measure the ESF directly, and compute the OTF from this. (Schowengerdt [2000]) As briefly mentioned, directly measuring the PSF is impossible, but measuring the ESF is easy - we simply need a black square and a white square with a sharp boundary, which is a standard test target for photographic systems. From there, taking the first derivative, then the Fourier Transform yields the 1D OTF. Then, taking the absolute value yields the MTF. 4 Landon Carter May 11, 2016

2.2.1 Airy Disk The prototypical PSF of an optical system is the Airy Disk, which is described by the equation ( ) 2 2J1 (ka sin θ) I(θ) = I 0 (2) ka sin θ Where I(θ) is the intensity at θ, the angle of observation from the optical axis. I 0 is the intensity at θ = 0. J 1 is the Bessel Function of the first kind of order one, k = 2π/λ is the wavenumber, and a is the radius of the aperture. In particular, ka sin θ = πq, where q is λn the radial distance from the optical axis and N is the photographic aperture. The shape of the Airy Disk is shown in Figure 6. Fig. 6: Airy Disk, with normalized intensity. 3 ESF Measurement Our basic goals in this experiment are to measure the ESF of a lens, while maintaining enough resolution for detailed analysis. Therefore, we made us of a special pixel-shifting camera, the Vieworks VN-29-MC, which is a 29MP 35mm monochrome machine vision camera featuring 5.47 µm pixels. This camera is special and particularly well-suited to lensmeasurement applications because the sensor is mounted on a piezo-drive stage, which can be moved laterally and vertically with a published resolution of 1 nm, allowing interpolation of virtual pixels down to a theoretical resolution of 1 nm. This resolution is well beyond the theoretical best resolution of any photographic lens. In order to measure the ESF, we 5 Landon Carter May 11, 2016

selected a common focusing target, a grid of white and black squares (from which a single edge transition was selected), which was illuminated with a 100W white LED to eliminate sensor noise. The exposure time was tuned to avoid saturating the sensor while providing maximum dynamic range. In order to allow for precise focusing, the lens was mounted on focusing bellows. In order to achieve sufficient resolution while decreasing experimental time, a 1823 nm shift was selected, for 3 frames total per test point. This was selected on the basis of the smallest diameter we might see, 1.8 µm, based on the Airy disk diameter for an f/1.8 lens with green light. If we had noticed resolution suffering as the lens performs better than expected, we could have decreased the shift further, though this did not turn out to be necessary. In Figure 7 is an example output from the camera in the final setup. Fig. 7: Sample output from the test setup. Most important is the white/black edge transition, which is a spatial step function, from which we can measure the ESF directly, and indirectly compute the MTF. 3.1 Pixel-Shift Validation In order to validate the pixel-shifting capabilities of the camera, a high-contrast, irregular object (in this case, a scrap aluminum billet with irregular surface finish) was imaged twice - once with a pixel shift of 0 nm, once with a pixel shift of +5470 nm (1 pixel). Then, the 2-dimensional cross-correlation was taken between these two images. As expected, a peak was observed at a 1-pixel offset, confirming that the sensor shifted the correct amount. 6 Landon Carter May 11, 2016

4 Results and Discussion From the raw data, we first interleave the three images, effectively tripling the resolution, and achieving an effective pixel pitch of 1.82µm. We extract the ESF by vertically averaging a small region of the edge, then normalizing. Shown in Figure 8 is an example of the ESF obtained from this technique. There are 15 micropixels between an intensity of 0.9 and 0.1 at f/22. This indicates that we have increased our resolution to a sufficient threshold to resolve the transition from white to black. Fig. 8: The edge spread function of a Nikon 50mm f/1.8d at f/22, measured by averaging columns of pixels around the white/black transition mentioned in Figure 7. Notably, our camera has enough resolution through micropixel stepping to resolve the S-curve nature of the step response. After obtaining the ESF, we can take a numerical derivative to obtain the LSF, as shown in Figure 9. Notice that the noise is much higher on the high side, which is due to photon noise - the noise due to different numbers of photons hitting the system follow a Gaussian distribution, centered around the true value, where the standard deviation increases with the mean. Thus, the white side has higher noise. Finally, after obtaining the LSF, we run a Fast Fourier Transform (FFT) to obtain the OTF, then take the absolute value to obtain the MTF, as shown in Figure 10. To validate our method, compare the value at 30 lp/mm to Nikon s published data. At 30 lp/mm, Nikon s published data indicates a gain of 0.6 in the center of the image, decreasing slightly from there. Our test location is fairly close to the center of the image - the region of interest was 684 pixels from the center of the image vertically and 601 pixels away from the center of the image horizontally, for a total real world distance of 4.98mm. Reading off Nikon s MTF chart, we therefore expect a gain of about 0.51. Indeed, we calculate a gain of 0.473 ± 0.074 at 30 lp/mm. The two results match, confirming our experimental setup produces reasonable results. 7 Landon Carter May 11, 2016

Fig. 9: The line spread function of a Nikon 50mm f/1.8d at f/22. The plot has been inverted, equivalent to reversing the transition from black to white instead of white to black. Fig. 10: The MTF of a Nikon 50mm f/1.8d at f/2. Finally, we arrive at the data we re interested in - how aperture affects the MTF. As mentioned previously, there are two factors at play - manufacturing and design flaws limiting performance, which will dominate at the wide apertures, and diffraction limit, which will dominate at the small apertures. In Figure 11, we can see the gain at 30 lp/mm for each aperture, and see clearly that lens performance is optimal at f/4. At wider apertures, the lens performs significantly worse than the diffraction limits, and at smaller apertures, it is mostly controlled by the diffraction limit. A full comparison of the MTF for all apertures is presented in Figure 12. 8 Landon Carter May 11, 2016

Fig. 11: Comparison of gain at 30 lp/mm for all apertures of the Nikon 50mm f/1.8d. We can clearly see that at f/2 and f/2.8, manufacturing or design flaws clearly limit lens performance, while the steady decline in performance from f/4 through f/22 is the result of diffraction limiting. The information gleaned from this - namely that f/4 is the best-performing aperture, can not typically be found in lens specifications. Fig. 12: MTF comparison for all whole apertures of the Nikon 50mm f/1.8d. Here we can see that all apertures exhibit similar decline in performance at higher spatial resolutions, and can compare different apertures at each spatial resolution. f/4 clearly remains the bestperforming aperture for most of the frequency range, while f/2 is the worst for most of the frequency range. 9 Landon Carter May 11, 2016

5 Conclusions A new method for computing the MTF of lenses has been tested and works as desired, making use of a pixel-shifting camera to achieve extremely high resolution capable of testing the resolution limits of modern lenses. This method can give the full MTF at all spatial frequencies, which is superior to the published MTF curves, which give an incomplete view of lens performance. This data matches published data to within 10%, which is almost certainly within sample-to-sample variation of the lens tested. In particular, the measured gain at 30 lp/mm and an offset of 5mm was 0.473±0.074, while the published gain was 0.51. In future work, we hope to confirm the results by testing against different lenses, testing different radial distances from the optical axis, and characterizing the performance further, including the effects of focus on lens performance. We also would like to characterize sampleto-sample variation among lenses, especially to quantify (if it exists) a relationship between lens price and sample-to-sample variance. Acknowledgements The author would like to thank Bayley Wang for use of his camera, Peter Krogen for helpful discussions, and Dr. Hughey and Professor Fang for support, including purchasing of the bellows and helpful discussions. References Nikon. Af nikkor 50mm f/1.8d. URL http://www.nikonusa.com/en/nikon-products/ product/camera-lenses/af-nikkor-50mm-f\%252f1.8d.html. PixeLarge. Aperture tutorial. URL http://pixelarge.com/ aperture-quick-photography-tutorials/. Robert Schowengerdt. Diffraction optics. ECE 425 Class Notes, 2000. 10 Landon Carter May 11, 2016