Incandescent Lighting: Enclosed and Gasketed

A-51 Incandescent Factory Sealed Luminaires Explosionproof Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.

FLUORESCENT/AREA: NEC/CEC EXPLOSIONPROOF. Applications. Illustrated Features

Class II, Division 1 and 2, Groups E, F, G Class III CSA 4X

AVP SERIES Aluminum Lighting for Hazardous and Severe Environments

Mercmaster LED Low Profile Luminaires with Emergency Battery Backup Enclosed and Gasketed Fixtures

BVP SERIES Brass Lighting for Marine and Hazardous Environments

EVLP Low Profile Hazard Gard (H.I.D.) Luminaires

AGUB Instrument and Meter Enclosures Explosionproof, Dust-Ignitionproof Furnished with aluminum body and solid or window cover.

Cl. I, Div. 1, Group B (with suffix GB), C, D Cl. I, Zone 1, Group IIB + H2

10 Hazlux Lighting US Brochure

Description Cast Device Box, Height Inch; Width 2.81 Inch; Depth 2.69 Inch; Capacity 25 Cu Inch; 1 Gang; 2 Hub(S); Hub Location End;

Baymaster LED Luminaire High Bay for Hazardous Locations

Baymaster HL LED Luminaire High Bay for Hazardous Locations

Industrial Mercmaster LED Generation 3 Series Luminaires For Ordinary Locations

Bullet EL Volt Die-Cast Aluminum, PAR38 Incan. / Halogen / R40 Incan. revision 8/15/11 el220.pdf

FSK1VDRA 1G Al DPLX RCPT CVR

Class 1 Division 2 Fluorescent Light - 2 Foot 3 Lamp - Corrosion Resistant Requirements

COMMERCIAL AND INDUSTRIAL FITTINGS: CAST DEVICE BOXES. Applications

Areamaster Generation 2 HL LED Luminaire Floodlight for Hazardous Locations

Lowlighter KLV Volt Die-Cast Brass, MR16 Halogen revision 2/25/14 kl_klv275_spec.pdf. Ravenna TM. Specifications. Approvals: Type: Job:

AERODOME PARKING/ROADWAY (TYPE III)

commercial and industrial fittings: cast DEVICE BOXES Applications Illustrated Features

Micro-Flood EL / 277 Volt Die-Cast Aluminum LED revision 4/11/11 el217.pdf

Spun Copper Bullet C to 277 Volt Spun Copper LED revision 11/7/14 kl_c24led_spec.pdf

EVLS Hazard Gard. Compact & Rugged, Explosionproof Luminaire. High-Pressure Sodium Metal Halide Pulse Start Metal Halide

Class 1 Division 2 Fluorescent Light - 4 foot 2 lamp - UV bulbs - Glass Lens

Series 5 Die Cast Aluminum Conduit Outlet Bodies, Covers and Gaskets

Floor Boxes. Concealed Service Floor Boxes. Engineering Data 663 Series. Faces Plates for 663 Floor Box. 663 Series Floor Box

AREA LIGHTING HYPAK SERIES HYPAK - HP3 HYPAK - HP4

VG Series LED Parking Structure Luminaire

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4

INSTALLATION INSTRUCTIONS F Series Floodlight

Exterior Decor LIGHTING. Bulkheads. architectural lighting. See our Bulkhead family sizes. Over 50 styles to choose from.

SECTION LIGHTING FIXTURES AND LAMPS

Atlantic LED Exit and Emergency Light AI EECXERB1

DISCONTINUED. LTV10 Series Composite Housing Accent. Specifications. Lightvault. Type: Job: Catalog number: Approvals: Fixture Options: / / /

For energy savings select ceiling-mounted luminaires that use fluorescent lamps.

10W Vapor Proof LED Fixture V AC - Replacement for 100W Incandescent - IP65

Cree Edge Series LED Canopy Luminaire

Industrial Areamaster Generation 2 HL LED Luminaire Floodlight for Ordinary Locations

LUXTRAN Luminaires for Tunnel Applications

Commercial/Retail Lighting

Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB)

IL 3525 Series. LED Industrial Lighting. Advantages of IL3525. Application

SECTION LIGHTING PART 1- GENERAL

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description

EPL-48-1L Surface Mount Explosion Proof, Waterproof Fluorescent Lights -Paint Booth, Rigs - 1 Lamp -

Explosion Proof Fluorescent Ultraviolet Light - Class 1 & 2-4' 2 lamp - Paint Booths, Rigs, Marine

DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications. Patent Pending

LOW LEVEL LE1/2/3. Lantern Bollard. Era. For pathways, courtyards and entrances.

F5513 APOGEE 30"DIA 3LTS PENDANT INSTALLATION INSTRUCTIONS WARNING

VM5 CATALOG ORDERING LOGIC

Designed for flexibility and performance, wherever people need durable outdoor luminaries. Paraflood Series

GE Lighting. High Bay Lighting. (ABV-Series) imagination at work

Cree Edge Series LED Area Luminaire Round

INSTALLATION INSTRUCTIONS IMPORTANT SAFEGUARDS SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS

Decorative luminaires for open ceiling commercial and retail applications. Indy Commercial/Retail Lighting

Square Straight Steel - 4 Bolt Base Light Poles

Jefferson Electric Inc Product Catalog JE901

Basics Series Retrofit LED. Economical 4", 5" and 6" Downlight Trims

Introducing the SIGNATURE SERIES

Conduit End Bells...EA1 Hex Reducing Bushings...EA2 Conduit Hubs...EA3-EA4. Split Couplings...EA5 Three Piece Couplings...EA6 Conduit Nipples...

Cree Edge Series LED Area/Flood Luminaire

FUEL GAS PIPING SECTION A. The provisions of SECTION 15010, MECHANICAL GENERAL REQUIREMENTS, apply to this section.

General Installation Instructions LED

LUXTRAN Luminaires for Tunnel Applications

RAIL 4 INSTALLATION INSTRUCTIONS. RM4DOD Recessed GENERAL SAFETY INSTRUCTIONS: NOTE:

GLASS GLOBE MOBILE LINEAR CHANDELIER

(SMS MOUNT SHOWN) Prefix Mounting Optics Lamp Wattage Length Volts Finish Options & Accessories 14W 21W 28W 2' 3', 6' 4', 8' T5HO 2' 3', 6' 4', 8'

CY3 3-1/2" Integrated LED Indoor and Outdoor Cylinders

Interior Accent. Lighting. Kaleidoshade 2

PRELIMINARY. 2700K, 3000K, 3500K, 4000K, Static Red, Static Green, Static Blue, Static Amber

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

SECTION LIGHTING

Bulletin 800R 30.5 mm Push Button Stations Hermetically Sealed for Division 2/Zone 2

Olivio Medio LED 5YEAR LED WARRANTY. Order Code: Pole Order Code: Series Height Finish Options. Customer: Date: Project: Qty: Type:

FFW / LED Flood / Wall Pack Combo

THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

Steps for Selecting the Proper Transformer

HD4 Cans. Features Aperture Shape. Dimensions and Weight. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 4.

GE Evolve Canopy LED Soffit ECLS

R L L D R L M S T A N D A R D D O M E

Sienna Pendant Drop Lens PENDANT

SERIES C87/C88 Low Voltage LED Cylinder for Remote Driver/Power Supply

SELECTIONS LED LIGHTING NOW AVAILABLE! Wraparound 39W Dimmable LED. Futra 25W Dimmable. LED Ceiling Fixture. Ceiling Fixture

Ground Clamps Cable Tray

2.5. Contents Description Motor Drive Isolation Transformers... Mini Power Centers... Totally Enclosed Non-Ventilated Transformers

GE Lighting. Albeo LED Luminaire. High Bay Lighting. (ABV-Series) imagination at work

Series 80 In-Line Mounted Centrifugal Pumps

INDIRECTTM. Cubic INDIRECT INDIRECT/CUBIC INDIRECT

Ductwork Controls and Instrumentation Outlets (HVAC) HVAC Control System.

Hazardous area LED lighting Pauluhn Summit linear LED luminaires. Pauluhn Summit. Linear, high bay LED luminaires designed for hazardous areas

Evolve LED Roadway Lighting

Hollywood Style. Theater Dressing Room Make-up Mirror Lighting. Beautiful. 2+2 or SLC Decorative Strip Lights

HSAF Era Stepped Aluminum Fluted Pole revision 10/6/15 kl_hasf_spec.pdf

This specification describes the minimum requirements for service water piping systems (ie: cooling water, process water, etc.), located on surface.

ELECTRICAL. Hertz 50/60 Input Current.7 -.3A. -20 C to +45 C Operating Temp. -4 F to +113 F. Power Factor > 0.9 THD. 1.5 (38.1mm)

Your Expression is our Passion The CAST Impressionist Series

05 Pg A75-90.qxp 6/9/2008 9:36 AM Page A75 RACO Floor Boxes

Transcription:

Stylmaster Incandescent Luminaires NEC: CSA: V Class II, Division 1 and 2, Groups E, F, G Class III Enclosure 4X Lighting Lighting: Area Incandescent Applications Enclosed and gasketed lighting fixtures for use in storage areas, tunnels, subways, chemical plants and other areas where moisture, dirt or corrosive atmospheres are a problem. Suitable for use in wet locations. Standard fixtures designed for 60 to 300 Watt medium base incandescent lamps. Pendant, feed-thru, ceiling, stanchion and wall mounts available. Ventilated steel reflectors with white porcelain finish are available for standard applications. Fiberglass reinforced polyester reflectors are designed for installations where fixture is subject to severe corrosive conditions or vandalism. Features Modern styling, with clean-line mounting hood and prismatic glass globe, plus optional guard. Prismatic globe, furnished as standard, eliminates glare and distributes light evenly. Globe seats firmly against composition gasket in mounting hood to keep out dirt and moisture. Full threads eliminate cross threading. Fixture is complete with gaskets and socket. Socket is shockabsorbing to prolong lamp life and can be easily removed for wiring without tools. Porcelain socket construction assures long trouble-free operation in high ambient installations. Both porcelain steel and polyester reflectors are secured to mounting hoods with screws (furnished). Guards have exclusive snap-on attachment feature for quick installation and fast servicing. Choice of reflector styles: (1) steel reflector with white porcelain enamel in standard dome and 30º angle (2) fiberglass reinforced polyester reflector in standard dome and 30º angle. Maximum input voltage 277 V (suitable for DC applications). Standard Materials Mounting hoods: copperfree (4/10 of 1% max.) aluminum Guards: pressure cast copperfree (4/10 of 1% max.) aluminum Reflectors: porcelain steel or fiberglass reinforced polyester Socket: porcelain with brass screw shell Globes: prismatic glass Standard Finishes Mounting hoods and guards: epoxy powder coat Steel reflectors: baked white porcelain enamel Fiberglass reinforced polyester reflectors: natural finish Socket and globes: natural finish Options To order fixture with other than standard clear glass globe, add suffix letters to catalog number as indicated in table, and adjust difference in price. Color Glass Globe Plastic Globe Amber -AM -PAM Blue -BL -PBL Green -GR -PGR Red -RE -PRE Clear Heat-Resistant -HR Illustrated Features Mounting Hood Pendant style shown has setscrew to prevent fixture stem from turning. Other styles include stanchion, ceiling and wall mounting. Shock-Absorbing Medium Base Socket Spring absorbs vibration to prolong lamp life. Porcelain construction for trouble-free operation in high ambient installations. Globe Attractive, tapered prismatic glass globes for glare elimination and uniform light distribution. Colors available also vandal-resistant plastic globes. Globe seats firmly against gasket to exclude moisture, dirt and vapors. Guard Snap-on guards (and reflectors) simply snap-in and twist. Spring action balls snap into detents of fixture body. Guard and Reflectors Certifications and Compliances UL Standard: UL 1598, UL 844 UL Listed: E10444 CSA Standard: C22.2 No. 250, C22.2 No. 137 CSA Certified: 025428 1126

Stylmaster Incandescent Luminaire Thermal Suitability NEC: CSA: V Class II, Division 1 and 2, Groups E, F, G Class III Enclosure 4X Fixture is suitable for Class I, Division 2 where the fixture operating temperature does not exceed the ignition temperature of the atmosphere in which fixture is installed. T Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations Supply Wire: 392 ºF/200 ºC T Number T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6 Temp. Range ( ºF) 664-842 619-662 574-617 538-572 502-536 448-500 421-446 394-419 358-392 331-356 322-329 277-320 250-275 214-248 187-212 185 Temp. Range ( ºC) 351-450 326-350 301-325 281-300 261-280 231-260 216-230 201-215 181-200 166-180 161-165 136-160 121-135 101-120 86-100 85 VPGL-1HR (60-200 W) VPGL-2HR (200-300 W) Reflector A-21 100 W A-21 150 W A-23 200 W A-23 200 W PS-25 200 W PS-30 200 W PS-25 300 W PS-30 300 W None T3 T2D T2C T2C T2C T2C 325 325 Standard Dome T2D T2D T2B T2B T2B T2C 325 325 30º Angle T2D T2C T2B T2B T2B T2B 325 325 Fixture Ambient Suitability: Fixture Ambient Suitability: Class II, Groups E, F, G; Class III; Enclosure 4X Areas ºF ºC Fixture Watts Non-Classified 392 200 A-23 60 to 300 Classified 104 40 PS-30 60 to 300 Lighting: Area Incandescent Lighting 1127

Stylmaster Incandescent Luminaires NEC: CSA: V Class II, Division 1 and 2, Groups E, F, G Class III Enclosure 4X Without Guard With Guard Type Lamp Watts Hub Size (Inches) Pendant 3/4 tapped opening Furnished with 3/4 to 1/2 reducer NEC Catalog Numbers CSA Catalog Numbers V With With Globe With Globe Only and Guard Globe Only With Globe and Guard A-23 60-200 1/2 or 3/4 VPA1075G VPA1075 VCA1075G VCA1075 PS-30 200-300 1/2 or 3/4 VPA2075G VPA2075 VCA2075G VCA2075 Ceiling Five Tapped Openings With mounting lugs and four close-up plugs 1/2 VPX1050G VPX1050 A-23 60-200 3/4 VPX1075G VPX1075 VCX1075G VCX1075 Lighting Lighting: Area Incandescent PS-30 200-300 1/2 VPX2050G VPX2050 3/4 VPX2075G VPX2075 VCX2075G VCX2075 Ceiling Outlet Box Mounting Fits SEH ➊ or VPJB cast outlet box, or 4 octagonal outlet box Furnished with screws and gasket Octagonal outlet boxes for non-classified areas only A-23 60-200 3/4 VPOB10G VPOB10 VCOB10G VCOB10 45 Stanchion 1-1/4 Conduit PS-30 200-300 3/4 VPOB20G VPOB20 VCOB20G VCOB20 A-23 60-200 1-1/4 VPAN10125G VPAN10125 VCAN10125G VCAN10125 PS-30 200-300 1-1/4 VPAN20125G VPAN20125 VCAN20125G VCAN20125 ➊ Order SEH box from catalog Fittings Section, 4 octagonal steel boxes from the Commercial Products Section and VPJB cast box from this Section. 1128

Stylmaster Incandescent Luminaires NEC: CSA: V Class II, Division 1 and 2, Groups E, F, G Class III Enclosure 4X NEC Catalog Numbers CSA Catalog Numbers V Without Guard With Guard Type Lamp Watts Hub Size (Inches) With Globe and Guard With Globe Only With Globe and Guard Wall Body includes outlet box with five tapped openings With mounting lugs and four close-up plugs A-23 60-200 1/2 VPWB1050G VPWB1050 With Globe Only 3/4 VPWB1075G VPWB1075 VCWB1075G VCWB1075 PS-30 200-300 1/2 VPWB2050G VPWB2050 3/4 VPWB2075G VPWB2075 VCWB2075G VCWB2075 Wall Outlet Box Mounting Fits SEH ➊ or VPJB cast outlet box, or 4 octagonal outlet box Furnished with screws and gasket Octagonal outlet boxes for non-classified areas only A-23 60-200 VPOBW10G VPOBW10 VCOBW10G VCOBW10 PS-30 200-300 VPOBW20G VPOBW20 VCOBW20G VCOBW20 Wall Outlet Box Mounting with Side Hubs With two side hubs and one close-up plug A-23 60-200 3/4 VCW1075G VCW1075 PS-30 200-300 3/4 VCW2075G VCW2075 Lighting: Area Incandescent Lighting ➊ Order SEH box from catalog Fittings Section, 4 octagonal steel boxes from the Commercial Products Section and VPJB cast box from this Section. 1129

Stylmaster Incandescent Luminaire Accessories Pendant Description Hub Size (Inches) NEC Catalog Numbers CSA V Furnished with setscrew, 3/4 to 1/2 reducer for 1/2 stem, medium base socket. VPA75 VCA75 Ceiling Five Tapped Openings Four close-up plugs 1/2 VPX50 VCX50 3/4 VPX75 VCX75 45º Stanchion 1-1/4 VPAN125 VCAN125 Lighting LIGHTING: ENCLOSED AND GASKETED AREA INCANDESCENT Wall Five Tapped Openings in Outlet Box ➊ Four close-up plugs Cast Outlet Box Only Five Tapped Openings Four close-up plugs. No socket. Fits VPOB, VPOBW and VPWB. Ceiling For Outlet Box Wall For Outlet Box ➊ (Octagonal outlet boxes for non-classified areas only) Fits SEH or VPJB cast outlet box, or 4 octagonal outlet box. With screws and gasket. (Octagonal outlet boxes for non-classified areas only) Fits SEH or VPJB cast outlet box, or 4 octagonal outlet box. With screws and gasket. Wall Outlet Box Mounting with Side Hubs With two side hubs and one close-up plug (Octagonal outlet boxes for non-classified areas only) 1/2 VPWB50 3/4 VPWB75 1/2 VPJB50 VCJB50 3/4 VPJB75 VCJB75 VPOB1 VPOBW1 VCOB1 VCOBW1 3/4 VCB75 ➊ Use 30º angle reflectors for wall installations center line of fixture must be located at least 5-3/4 away from wall. Has four 3/16 dia. mounting holes located 90º apart on a 3-1/2 dia. center. 1130 November 2011

Stylmaster Incandescent Luminaire Accessories Glass and Polycarbonate Globes ➊ Catalog Numbers Type Lamp Watts Color Glass Polycarbonate Clear VPGL-2PL Clear Heat-Resistant VPGL-1HR Amber VPGL-1AM VPGL-2AMPL A-23 60-200 Blue VPGL-1BL VPGL-2BLPL Glass Globe (VPGL-1HR) Glass Globes Polycarbonate Globe (VPGL-2PL) PS-30 Green VPGL-1GR VPGL-2GRPL Red VPGL-1RE VPGL-2REPL 200-300 Clear Clear Heat-Resistant VPGL-2HR Amber VPGL-2AM Blue VPGL-2BL Green VPGL-2GR Glass Globe (VPGL-2HR) Red VPGL-2RE Coated Tuff-Skin Glass Globes Contains globe safely even if glass is broken Guards VPGU-1 VPGL-2HRT VPGU-2 Heat-Resistant VPGL-2HRT Type Replacement Porcelain Shock-Absorbing Sockets Medium Base Replacement Gasket for Globes Lamp Watts NEC Catalog Numbers CSA V A-23 60-200 VPGU-1 VCFGU-1 PS-30 200-300 VPGU-2 VCFGU-2 A-23 60-200 PS-30 200-300 VPLR-123 VCLR-1 Lighting: Area Incandescent Lighting Globe Gasket Neoprene for all Stylmaster globes VPGL-GK VCGL-GK Registered trademark of Thomas Manufacturing Corporation, Parkton, Md. ➊ Shatter-resistant for use in food processing plants, canneries, dairies, breweries, bakeries or anywhere broken glass would prove a hazard. Ideally suited for areas where vandalism, high replacement and high maintenance costs are a problem. CAUTION: Use maximum 200 W lamp less reflector, 100 W max. with reflector or colored globe. Do not use in ambients exceeding 25 ºC/77 ºF. For burning in vertical base-up position only. 1131

Stylmaster Incandescent Luminaire Reflectors and Accessory Weights Description Porcelain Steel Catalog Number Polyester Standard Dome Reflector LPR-25ST LPRP-25ST 30º Angle Reflector LPR-25AN LPRP-25AN Weights Lighting Lighting: Area Incandescent Typical Mounting Hoods Pendant lbs/kg Ceiling lbs/kg Wall lbs/kg Stanchion lbs/kg VPA75 VPX75 VPOBW10 VPAN-125 2/0.9 2/0.9 3/1.4 VCA75 VCX75 VCOBW10 VCAN-125 Globes and Guards Type Globe lbs/kg Guard lbs/kg Reflectors 3/1.4 Standard Dome lbs/kg 30 º Angle lbs/kg 60-200 W VPGL-1 2/0.9 VPGU-1 1/0.5 LPR-25ST 3/1.4 LPR-25AN 2/0.9 200-300 W VPGL-2 3/1.4 VPGU-2 1/0.5 LPRP-25ST 2/0.9 LPRP-25AN 2/0.9 1132

Stylmaster Incandescent Luminaire Dimensions Pendant Mount ➊ 45 Stanchion Mount ➊➋ 3.00"/ 76.2 mm 7.00"/ 177.8 mm 3.00"/ 76.2 mm 10.55"/268.0 mm 9.23"/ 234.4 mm 12.08"/306.8 mm 11.19"/ 284.2 mm 6.52"/ 165.6 mm 6.08"/ 154.4 mm 8.52"/ 216.4 mm 8.08"/ 205.2 mm 6.88"/ 174.8 mm 5.96"/ 151.4 mm 8.40"/ 213.4mm 7.52"/ 191.0 mm Ceiling Outlet Box Mount Ceiling Mount for Junction Box Wall Mount with Junction Box Wall Outlet Box Mount 7.00"/ 177.8 mm 4.00"/ 101.6 mm 1.68"/ 42.7 mm 0.33"/8.4 mm R (+ DFT) (2 PLACES) 0.22"/5.6 mm R (+ DFT) (2 PLACES) 3.50"/ 88.9 mm B.C 3.60"/ 91.44 mm Dia. -2" DFT 4.00"/ 101.6 mm Dia. +2" DFT 4.75"/ 120.7 mm 7.00"/ 177.8 mm 4.06"/ 103.1 mm 1.58"/ 40.1 mm Dia. + DFT 3.56"/ 90.4 mm 7.13"/ 181.1 mm 10.63"/ 270.0 mm Junction Box Mounting Body 0.13"/3.3 mm R. Max (8 Places) 3.31"/ 84.1 mm 3.50"/ 88.9 mm 0.19 /4.8 mm Dia. Mtg. Hole 4.00"/ 101.6 mm 4.00"/ 101.6 mm 1.88"/ 47.8 mm 5.25"/ 133.4 mm 8.75"/ 222.3 mm 3.31"/ 84.1 mm Lighting: Area Incandescent Lighting ➊ Height of hood is measured to bottom of flange. Height of globe and guard is from bottom of flange. ➋ Dimensions of angle are from center of pipe. Height is measured from pipe stop in stanchion hood. 1133

Stylmaster Incandescent Luminaire Dimensions Without Reflector Effective Floor Cavity Reflectance (Rfc) is 20% % Ceiling Rcc 80 70 50 30 10 0 % Walls Rw 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 1.739.689.645.684.640.598.583.548.517.489.464.439.404.384.365.322 2.618.548.489.572.509.456.484.435.391.403.365.331.329.299.273.234 ROOM CAVITY RATIOS 3.527.449.386.487.416.360.411.355.308.340.297.259.275.240.210.176 4.460.378.316.425.351.294.358.299.253.297.250.212.239.202.172.140 5.398.319.258.370.296.240.313.252.206.258.209.172.208.169.138.110 6.353.273.216.325.253.199.274.215.170.227.178.141.183.143.112.087 7.312.234.181.288.216.167.242.183.141.199.152.116.161.122.092.069 8.279.204.152.257.189.142.217.161.120.180.133.099.144.106.077.056 9.251.179.130.232.166.121.196.141.102.162.116.083.130.092.065.045 10.226.157.112.208.146.104.177.124.087.146.102.070.118.081.054.037 Lighting Lighting: Area Incandescent Standard Dome Effective Floor Cavity Reflectance (Rfc) is 20% 30 Angle % Ceiling Rcc 80 70 50 30 10 0 % Walls Rw 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 ROOM CAVITY RATIOS 1.777.747.719.759.731.706.724.701.681.693.676.658.666.650.636.620 2.679.631.589.665.620.583.636.599.566.610.580.552.587.561.537.521 3.593.534.486.581.525.481.557.510.471.535.495.461.514.480.451.435 4.523.459.409.513.453.405.492.440.398.473.428.391.456.416.384.367 5.459.391.340.449.385.337.433.376.334.416.366.328.401.358.323.307 6.406.337.289.397.333.285.382.325.282.368.317.278.356.310.274.259 7.359.291.246.352.287.242.339.279.238.326.274.235.316.269.232.217 8.323.257.211.316.254.210.305.248.208.295.243.205.284.238.203.188 9.291.227.182.286.223.182.275.219.180.266.214.178.257.210.175.161 10.262.200.159.257.199.159.249.194.157.240.290.154.234.187.152.140 Photometric data shown on this page is based on a 200 Watt A-23 lamp and is representative of the performance for all Stylmaster incandescent fixtures. For candlepower values of fixtures with other lamps, multiply the given candlepower values by the following multipliers: for 75 W A19 0.31; for 100 W A19 0.45; for 150 W A21 0.75; and for 300 W PS25 1.65. For candlepower values of fixtures with guard, multiply by 0.90. 1134