ACS600, ACS800. Installation Guide

Similar documents
Switching Power Supply Type SPP1 60W Enclosed type

EN 50178, IEC

Emotron FDU 2.0 Variable Speed Drive

Emotron FDU 2.0 Variable Speed Drive

vacon 100 industrial vacon 100 flow vacon 100 hvac vacon 100 x ac drives du/dt filter technical guide

CP-T range Benefits and advantages

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

CP-T range Product group picture

ACH550 HVAC Drive Submittal

LXM32CD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Three-phase monitoring relays CM-PFE and CM-PFE.2

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

LXM32AD18M2 motion servo drive - Lexium 32 - single phase supply voltage 115/230V - 0.5/1kW

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

LXM32MD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

Subject to changes 11/2003 Page 1/7

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 690 Volts, 50Hz

Power supply CP-T 48/20.0 Primary switch mode power supply

LXM32MU60N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

LXM32AD72N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

Solid State Relay, 1-phase

Power supply CP-T 24/20.0 Primary switch mode power supply

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

ILA2E572PC1A0 integrated drive ILA with servo motor V - EtherCAT - indus connector

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Drive IT Low Voltage Drives. User's Guide for type ACS50 AC Drives from 0.18 to 0.75 kw

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Power Electronics. POWERSWITCH Solid-State Contactor BF 9250, BH 9250

TETRA COMPACT - E AND FLEXI - PRO

VMS-300A - XX - XXX - X

High Frequency Sinewave Guardian TM Filter

User's Guide for type ACS55 AC Drives from 0.18 to 2.2 kw

SKS SL 80 GD 50/10 - E4 P1

Power supply CP-E 24/2.5

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-E 24/20.0

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

ATS01N222LU soft starter for asynchronous motor - ATS01-22 A V KW

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

C B. Models. Models 2MOPP

CP-E range Benefits and advantages

Three-phase monitoring relays

VFB40 Frequency inverters 004 to 016 (B1) VFX40 Frequency inverters 018 to 037 (S2)

Measuring current transformers of the W, W series

Power supply CP-T 48/5.0 Primary switch mode power supply

Electronic timer CT-SDD.22

Control module CP-A CM

DSM Dynamic Shunt

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Electronic timer CT-TGD.22

Electronic timer CT-SDS.22

VOF XX - XXX - X

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

RE17LLBM asymmetrical flashing relay s V AC - solid state output

High Frequency SineWave Guardian TM Filter

Primary switch mode power supplies Product group picture

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

This Chapter contains:

PowerFlex 400 Submittal

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

To be automatically connected to the nearest North American Technical Sales Office:

SWF DV/DT Solutions Sinewave Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

TBX-1329 AC/DC COUPLING TERMINAL BLOCK

NLP65 SERIES 75 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.26

Solid-State Relays Zero-point switching, without heatsink

LDC240 Series is a single phase, ultra compact DIN Rail Switching Power Supply with active PFC, ideal for many applications.

Power supply CP-E 24/0.75

FP-RTD-124 AND CFP-RTD-124. Features. FieldPoint Operating Instructions. Eight-Channel Four-Wire RTD and Resistance Input Modules

Three-phase monitoring relay CM-PFS

Manual. MOVITRAC LTE-B/LTP-B Accessories Braking Resistors, Filters, Chokes, Shielding * _0515*

ATS22C21Q soft starter-ats22-control 220V-power 230V(55kW)/ V(110kW)

Power supply CP-T 24/10.0 Primary switch mode power supply

Series P. Applications

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

Zelio Control Measurement Relays

Power supply CP-T 24/40.0 Primary switch mode power supply

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

SKS SL 150 GD 50/10 - E4 P1

Transcription:

ACS600, ACS800 Installation Guide du/dt Filters AOCH0260-70 AOCH0400-70 NOCH0016-6x NOCH0030-6x NOCH0070-6x NOCH0120-6x NOCH0260-60 NOCH0400-60 NOCH0760-60

2003 ABB Oy. All Rights Reserved. 3AFE 58933368 REV D EN EFFECTIVE: 20.10.2003

3 Table of contents Table of contents Contents...................................................................... 5 General notes and restrictions..................................................... 5 Technical data.................................................................. 7 Ambient conditions, operation................................................... 7 Ambient conditions, storage..................................................... 7 Ambient conditions, transportation................................................ 8 Internal circuit diagrams.......................................................... 9 Power connections............................................................. 10 Filter selection tables............................................................ 17 Dimensional drawings.......................................................... 19 Table of contents

4 Table of contents

5 Contents This document contains the following information: General notes and restrictions Technical data (including allowable ambient conditions) Internal circuit diagrams Power connection diagrams Filter selection tables Dimensional drawings (including terminal sizes and tightening torques). General notes and restrictions Observe the following before you start to install the du/dt filters: WARNING! Do not attempt any work on a powered drive. After switching off the mains, always allow the intermediate circuit capacitors 5 minutes to discharge before working on the frequency converter, the motor or the motor cable. It is good practice to check (with a voltage indicating instrument) that the drive is in fact discharged before beginning work. Unprotected (IP00) filters must be encased to meet the local safety requirements. The surface of the IP22/IP54 filter housing can reach a temperature up to 40 C higher than the ambient temperature. Shielded cable must be used between enclosures. Filters must be grounded to the protective earth (PE) by using the fixing holes in the mounting legs. Maximum drive output frequency: 120 Hz Maximum average switching frequency: 3 khz (converter units with supply voltage < 500 V) or 2 khz (converter units with supply voltage > 500 V) Maximum cable length between the drive output and the filter: 3 m Maximum motor cable length for AOCH0xxx-70 filters: 300 m (cumulative for several parallel-connected motors)

6 Maximum motor cable length for NOCH0xxx-6x filters (cumulative for several parallel-connected motors): NOCH0016-60/62 NOCH0030-60/62 NOCH0070-60/62 NOCH0120-62 NOCH0016-65 NOCH0030-65 NOCH0070-65 NOCH0120-65 NOCH0120-60 NOCH0260-60 NOCH0400-60 NOCH0760-60 150 m (can be increased to 300 m by connecting two filters in series) 50 m (can be increased to 100 m by connecting two filters in series) 300 m The following free space requirements apply for the AOCH0xxx-70 filters: 150 mm free space on each free side. Exception: 500 mm above the filter if installed below the drive. Exception: 50 mm between single phase filters on the same transmission line. If filters are mounted on top of each other with SingleDrive types 0320-5, 0610-5 and 0610-7, the filters need a minimum of 700 m 3 /h of forced cooling. Maximum of three filters can be mounted on top of each other. 150 / 500 mm 150 / 500 mm 150 mm 150 mm 150 mm 150 / 50 mm 150 mm 150 mm 150 mm AOCH filters on top of each other AOCH filters side by side

7 Technical data NOCH0xxx-6x filters are designed to cool by natural convection, thus the following free space requirements apply: Wall-mounted filter units: 300 mm on each free side. Exception: 500 mm above the filter if installed below the drive. Floor-mounted filter units: 300 mm on each free side. Exception: 50 mm between single-phase filters on the same transmission line. Exception: 500 mm above the filter if installed below the drive. Nominal voltage: 380 690 V ± 10%. Rated short-time withstand current: 50 ka 1 s. Applicable standards and markings: EN 60204-1, EN 60529, EN 61800-3, EN 50178, CE marking, UL approval. Ambient conditions, operation Ambient operating conditions refer to the conditions du/dt filters are subjected to when installed for stationary use. Air temperature: -15 to +50 C. At temperatures from +40 C to +50 C, the rated output current is decreased by 1% for every additional 1 C. The output current is calculated by multiplying the current given in the rating table by the derating factor. Relative humidity: 5% to 95%, no condensation allowed. Maximum allowed relative humidity is 60% in the presence of corrosive gases. Installation site altitude: 0 to 4000 m. At altitudes from 1000 to 4000 m above the sea level, the rated output current is decreased by 1% for every 100 m. Vibration: AOCH0xxx-70: Max 1 mm (5 to 13.2 Hz), max 7 m/s 2 (13.2 to 100 Hz) sinusoidal (IEC 60068-2) NOCH0xxx-6x: Max 0.3 mm (2 to 9 Hz), max 1 m/s 2 (9 to 200 Hz) sinusoidal (IEC60068-2) Shock: Max 70 m/s 2, 22 ms (IEC 60068-2-27)

8 Ambient conditions, storage Ambient storage conditions refer to the conditions du/dt filters are subjected to during storage in the protective package. Temperature: -40 to +70 C. Relative humidity: Less than 95%, no condensation allowed Atmospheric pressure: 70 to 106 kpa Vibration: AOCH0xxx-70: Max 1 mm (5 to 13.2 Hz), max 7 m/s 2 (13.2 to 100 Hz) sinusoidal (IEC 60068-2) NOCH0xxx-6x: Max 0.3 mm (2 to 9 Hz), max 1 m/s 2 (9 to 200 Hz) sinusoidal (IEC 60068-2) Shock: Max 100 m/s 2, 11 ms (IEC 60068-2-27) Ambient conditions, transportation Ambient transportation conditions refer to the conditions du/dt filters are subjected to during transportation in the protective package. Temperature: -40 to +70 C Relative humidity: Less than 95%, no condensation allowed. Atmospheric pressure: 60 to 106 kpa Vibration: Max 3.5 mm (2 to 9 Hz), max 15 m/s 2 (9 to 200 Hz) sinusoidal (IEC 60068-2) Shock: Max 100 m/s 2, 11 ms (IEC 60068-2-27) Bump: Max 300 m/s 2, 6 ms (IEC 60068-2-29) Free fall: 250 mm

9 Internal circuit diagrams input 1.2 2.2 1 (A) 2 (X) 1.1 2.1 output AOCH0xxx-70: Connect the input terminals together. 1 (A) 1 (A) 1.1 1.2 2.1 2.2 2 (X) NOCH0120-60 2 (X) NOCH0260-60 NOCH0400-60 NOCH0760-60 PE U1 V1 W1 PE U1 V1 W1 U2 V2 W2 NOCH0016-6x NOCH0030-6x NOCH0070-6x U2 V2 W2 NOCH0120-6x

10 Power connections NOCH0260-60 NOCH0400-60 NOCH0760-60 NOCH0400-60

11 NOCH0016-6x NOCH0030-6x NOCH0070-6x NOCH0120-6x NOCH0260-60 NOCH0400-60 NOCH0760-60 AOCH0260-70 AOCH0400-70

12 NOCH0760-60

13 NOCH0400-60

14 NOCH0400-60

15 AOCH0400-70 AOCH0260-70

16 NOCH0120-6x: Cable lug installation [16to70mm 2 (6 to 2/0 AWG) cables] PE Isolate the ends of the cable lugs with insulating tape or shrink tubing. NOCH0120-6x: Cable terminal installation [95to185mm 2 (3/0 AWG to 350 MCM) cables] b a PE a. Connect the cable to the terminal. b. Connect the terminal to the drive.

17 Filter selection tables 60x- 0005-3, 0006-3 0009-3, 0011-3 SingleDrive 400 V 500 V 690 V 0006-5, 0009-5 0011-6, 0016-6 0009-6, 0011-6 0016-6 0016-3, 0020-3 0020-5, 0025-5 0020-6, 0025-6 0030-6 0025-3, 0030-3 0040-3, 0050-3 0060-3 0070-3,0100-3 0120-3 0140-3, 0170-3 0210-3 0030-5, 0040-5 0050-5, 0060-5 0070-5 0100-5, 0120-5 0140-5 0170-5, 0210-5 0260-5 0040-6, 0050-6 0060-6, 0070-6 0100-6, 0120-6 0140-6, 0170-6 0210-6, 0260-6 du/dt filter type (* 3 filters included in kits marked with *) *AOCH0260-70 x=0 IP 00, x=2 IP22, x=5 IP 54 0260-3, 0320-3 0320-5, 0400-5 0320-6, 0400-6 1 0400-3 0490-5 0490-6 2 0490-3, 0610-3 0610-5, 0760-5 0610-6, 0760-6 2 0900-6 1 0760-3, 0930-3 0930-5, 1090-5 1040-6, 1380-6 3 1120-3 1380-5 1710-6 2 1440-3, 1770-3 1760-5, 2160-5 2120-6, 2540-6 6 2140-3, 2340-3 2620-5, 2850-5 2800-6, 3350-6 4 2820-3 3450-5 3880-6, 5140-6 12 800-01- 0003-3, 0004-3 0004-5, 0005-5 0011-7 800-04- 0005-3, 0006-3 0006-5, 0009-5 1 0009-3, 0011-3 0011-5, 0016-5 0016-3, 0020-3 0020-5 0016-7, 0020-7 0025-7 1 0025-3, 0030-3 0040-3, 0050-3 0060-3, 0070-3 0100-3 0025-5, 0030-5 0040-5, 0050-5 0060-5 0070-5, 0100-5 0120-5 *AOCH0400-70 NOCH0016-6X 1 NOCH0030-6X 1 NOCH0070-6X 0030-7, 0040-7 0050-7, 0060-7 1 1 *NOCH0120-6x 0070-7, 0100-7 0120-7 1 0120-3 0140-5 1 0140-3, 0170-3 0170-5, 0210-5 0140-7, 0170-7 1 0210-3, 0260-3 0260-5, 0320-5 0210-7, 0260-7 1 0320-3 0400-5 0320-7, 0400-7 2 0400-3, 0440-3 0490-3 0440-5, 0490-5 0550-5, 0610-5 0440-7, 0490-7 0550-7, 0610-7 2 1 *NOCH0260-60 1 *NOCH0400-60 *NOCH0760-60

18 du/dt filter type (3 filters included in kits marked with *) MultiDrive x=0 IP 00, x=2 IP22, x=5 IP 54 6xx- 0005-3, 0006-3 0009-3, 0011-3 400 V 500 V 690 V 0006-5, 0009-5 0011-6, 0016-6 0009-6, 0011-6 0016-6 0016-3, 0020-3 0020-5, 0025-5 0020-6, 0025-6 0030-6 0025-3, 0030-3 0040-3, 0050-3 0060-3 0070-3, 0100-3 0120-3 0030-5, 0040-5 0050-5, 0060-5 0070-5 0100-5, 0120-5 0140-5 *AOCH0260-70 *AOCH0400-70 NOCH0016-6X 1 NOCH0030-6X 1 NOCH0070-6X 0040-6, 0050-6 0060-6, 0070-6 1 0100-6, 0120-6 0185-3, 0225-3 0215-5, 0255-5 0185-6, 0205-6 0255-6, 0315-6 1 0265-3, 0335-3 0325-5, 0395-5 0375-6, 0485-6 1 0405-3, 0500-3, 0630-3 0495-5, 0610-5, 0770-5 0600-6, 0750-6 0900-6 0765-3, 0935-3 0935-5, 1095-5 1045-6, 1385-6 3 1125-3 1385-5 1715-6 2 1440-3, 1775-3 1760-5, 2165-5 2125-6, 2545-6 6 2145-3, 2340-3 2625-5, 2850-5 2800-6, 3350-6 4 2820-3 3450-5 3880-6, 5140-6 12 800-104- 0003-3, 0004-3 0004-5, 0005-5 0011-7, 0016-7 0005-3, 0006-3 0006-5, 0009-5 1 0009-3 0011-5 0011-3, 0016-3 0016-5, 0020-5 0020-7, 0025-7 0030-7 1 0020-3, 0025-3 0030-3 0040-3, 0050-3 0060-3 0025-5, 0030-5 0040-5, 0050-5 0060-5, 0070-5 0040-7, 0050-7 0060-7 1 *NOCH0120-6x 1 1 *NOCH0260-60 *NOCH0400-60 *NOCH0760-60 1

19 Dimensional drawings AOCH0260-70, single phase filter du/dt filter kit includes 3 pieces of single phase filters.

20 Cable size: Screw size: Power loss: 3x(3x185) M12 147 W AOCH0260-70 Weight: I TH L 15.9 kg (35.1 lbs) 227 A rms 74 µh

21 AOCH0400-70, single phase filter du/dt kit includes 3 pieces of single phase filters.

22 Cable size: Screw size: Power loss: 3x(3x185) M12 250 W AOCH0400-70 Weight: I TH L 20.7 kg (45.6 lbs) 355 A rms 52 µh

23

24 NOCH0760-60 Weight: 43 kg (95 lbs) 1.1 1.2 2.1 2.2

25

26 NOCH0120-62, NOCH0120-65 Weight 45 kg (99 lbs) 64787845-A

3AFE 58933368 REV D / EN EFFECTIVE: 20.10.2003 ABB Oy AC Drives P.O. Box 184 FIN-00381 HELSINKI FINLAND Telephone +358 10 22 11 Fax +358 10 22 22681 Internet http://www.abb.com ABB Inc. Automation Technologies Drives & Motors 16250 West Glendale Drive New Berlin, WI 53151 USA Telephone 262 785-3200 800-HELP-365 Telefax 262 780-5135