400Amp True RMS AC Clamp Meter + NCV

Similar documents
200Amp AC Clamp Meter + NCV Model MA250

400Amp True RMS AC/DC Clamp Meter Model EX613

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

400Amp True RMS AC/DC Clamp Meter with IR Thermometer Model EX623

User s Guide. 400A AC/DC Clamp Meter. Model MA220

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

R/C SMD Tweezers Multimeter Model RC200

Compact MultiMeters + Voltage Detector

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

Safety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.

USER'S MANUAL DMR-6700

User s Guide. Model MA A AC Mini Clamp-on Meter

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer

Autoranging Multimeter Extech EX503

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

PCMT20 PYLE C;",D J WWWPYLEAUDIO.COM

Model True RMS AC/DC 30A Mini Clamp-on Meter. User Guide

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

User s Guide. Digital AC/DC Clamp Meter Model 38394

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

User Guide. Digital AC/DC Clamp Meter Model 38394

User Guide. AC/DC Mini Clamp Meter. Model

DM-45 Digital Multimeter

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

USER GUIDE. Extech EX850 True RMS 1000 Amp Clamp Meter. Bluetooth TM and Android TM ready. Patented

USER MANUAL. Extech EX850 True RMS 1000 Amp Clamp Meter. Bluetooth TM and Android TM ready. Patented

AUTORANGING TRUE RMS MULTIMETER USER GUIDE. INST151 Doc 1.00

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

Not for Reproduction

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

AC/DC CLAMP METER USER S MANUAL

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

Operating Instructions 22070T True RMS AC/DC CLAMP METER Instrucciones de uso. Pinza amperimétrica de CA/CC de RMS verdadera

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

ET-3888 True RMS Clamp Meter. User Manual

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

OPERATING INSTRUCTION

Pen Multimeter. Model

User Manual Digital Clamp Multimeter. model no.: MSR-C600

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

PeakTech 3355 / 3360

User Manual. All rights reserved. Specifications are subject to change without notice.

User s Guide Shop online at omega.com For latest product manuals: omegamanual.info

MODEL: D03128 CLAMP METER

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

USER S MANUAL DMR-1500

Sales: Technical: Fax:

User Manual Digital Multimeter. model no.: MSR-U1000

USER'S MANUAL DMR-4350

UT207A/208A/209A Operating Manual. Table of Contents

AC Clamp Meter + Phase Rotation Tester

User Manual 4 wire Earth Resistance Tester Model GRT300

NOTE: Fully read and understand this manual before using this Digital Multimeter.

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

Digital Clamp Meter (TRMS) Model : 2727

USER'S MANUAL AM-100 AM-105 TRMS AM-110 TRMS. Digital Multimeters

AMM-1022 Digital Multimeter USER`S MANUAL

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

600A Clamp Meters w/tightsight Display

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

DIGITAL MULTIMETER with Non-Contact Detection

DDM350 Pen-Type Digital Multimeter User s Manual

CONTENTS MS2033A. 1.Introduction Safety Information...01

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

DIGITAL CLAMP METER Use s Manual

USER'S MANUAL TBM061 TBM062 TBM063 TBM065

USER'S MANUAL DMR-4300

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

User Manual. All rights reserved. Specifications are subject to change without notice.

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

Digital Clamp Meter Model: &

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

DIGITAL MULTIMETER INSTRUCTION MANUAL

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

MW3105 DIGITAL CLAMP MULTIMETER

Digital Clamp Meter. User Manual

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

1.General instructions Specifications Description...7

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

True RMS AC / DC Power Clamp Meter Model

Contents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.

Passive Component LCR Meter

Transcription:

User Guide 400Amp True RMS AC Clamp Meter + NCV Model MA410T

Introduction Thank you for selecting the Extech MA410 Clamp Meter. This meter measures AC Current, AC/DC Voltage, Resistance, Capacitance, Frequency, Diode Test, Duty Cycle and Continuity. Custom features include Thermocouple Temperature and Non-Contact Voltage detection. The double molded case is designed for heavy duty use. This meter is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Extech Instruments is an ISO-9001 Certified company. Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present Double insulation WARNING CAUTION This WARNING symbol indicates a potentially hazardous situation, which if not avoided, could result in death or serious injury. This CAUTION symbol indicates a potentially hazardous situation, which if not avoided, may result damage to the product. PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY OVERVOLTAGE CATEGORY I Equipment of OVERVOLTAGE CATEGORY I is equipment for connection to circuits in which measures are taken to limit the transient over voltages to an appropriate low level. Note Examples include protected electronic circuits. OVERVOLTAGE CATEGORY II Equipment of OVERVOLTAGE CATEGORY II is energy-consuming equipment to be supplied from the fixed installation. Note Examples include household, office, and laboratory appliances. OVERVOLTAGE CATEGORY III Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations. Note Examples include switches in the fixed installation and some equipment for industrial use with permanent connection to the fixed installation. OVERVOLTAGE CATEGORY IV Equipment of OVERVOLTAGE CATEGORY IV is for use at the origin of the installation. Note Examples include electricity meters and primary over-current protection equipment 2

SAFETY NOTES WARNINGS Do not exceed the maximum allowable input range of any function. Do not apply voltage to meter when resistance function is selected. Set the function switch OFF when the meter is not in use. Remove the battery if meter is to be stored for longer than 60 days. Set function switch to the appropriate position before measuring. When measuring volts do not switch to current/resistance modes. Do not measure current on a circuit whose voltage exceeds 600V. When changing ranges always disconnect the test leads from the circuit under test. CAUTIONS Improper use of this meter can cause damage, shock, injury or death. Read and understand this user manual before operating the meter. Always remove the test leads before replacing the battery or fuses. Inspect the condition of the test leads and the meter itself for any damage before operating the meter. Repair or replace any damage before use. Use great care when making measurements if the voltages are greater than 25VAC rms or 35VDC. These voltages are considered a shock hazard. Always discharge capacitors and remove power from the device under test before performing Diode, Resistance or Continuity tests. Voltage checks on electrical outlets can be difficult and misleading because of the uncertainty of connection to the recessed electrical contacts. Other means should be used to ensure that the terminals are not "live". If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Function A AC, V DC, V AC Resistance, Capacitance, Frequency, Diode Test, Continuity, Temperature Maximum Input 400A 600V DC/AC 250V DC/AC 3

Description Meter Description 1. Current clamp 2. NCV LED indicator 3. Clamp opening trigger 4. MODE button 5. HZ/% button 6. LCD Display 7. Negative input jack 8. Non-Contact Voltage Detector 9. HOLD button 10. Function switch 11. Relative Button 12. Battery compartment (rear) 13. Positive input jack Display icons Description HOLD AUTO DC AC REL V A F Hz Data Hold Autoranging Direct Current Alternating Current Low battery Relative Volts (Voltage) Ohms (Resistance) Amperes (Current) Farad (Capacitance) Hertz (Frequency) % Duty Ratio o F and o C Fahrenheit and Celsius units (Temperature) n, m,, M, k Unit of measure prefixes: nano, milli, micro, mega, and kilo ))) Continuity test Diode test 4

Operation NOTES: Read and understand all Warning and Caution statements in this operation manual prior to using this meter. Set the function select switch to the OFF position when the meter is not in use. Non-Contact Voltage Detector WARNING: Risk of Electrocution. Before use, always test the Voltage Detector on a known live circuit to verify proper operation. 1. Rotate the Function switch to any measurement position. 2. Place the detector probe tip on the conductor to be tested. 3. If AC voltage is present, the NCV detector light will turn on with a steady red light. NOTE: The conductors in electrical cord sets are often twisted. For best results, move the probe tip along a length of the cord to assure placing the tip in close proximity to the live conductor. NOTE: The detector is designed with high sensitivity. Static electricity or other sources of energy may randomly trip the sensor. This is normal operation. AC Current Measurements WARNING: Disconnect the test leads before making clamp measurements. 1. Rotate the Function switch to the 400A position 2. Press the trigger to open jaw. Fully enclose only one conductor. 3. Read the current value in the display. 4. If the value is less than 40A, rotate the function switch to the 40A position to improve resolution. 5

AC/DC Voltage, Frequency, Duty Cycle Measurements CAUTION: Do not measure voltages if a motor on the circuit is being switched ON or OFF. Large voltage surges may occur that can damage the meter. 1. Rotate the function switch to the V position. 2. Press the MODE button to select AC or DC Voltage. 3. Insert the black test lead banana plug into the negative COM jack. Insert the red test lead banana plug into the positive V jack. 4. Touch the black test probe tip to the negative side of the circuit. Touch the red test probe tip to the positive side of the circuit. 5. Read the voltage value in the display. 6. Press the Hz % button to display Frequency 7. Press the Hz % button to display Duty Cycle Resistance, Diode, Continuity Measurements Note: Remove power from the device under test before making resistance measurements 1. Set the function switch to the position. 2. Insert the black test lead banana plug into the negative COM jack. Insert the red test lead banana plug into the positive V jack. 3. Touch the black test probe tip to one side of the device. Touch the red test probe tip to the other side of the device. 4. Read the resistance value in the display. 5. Press the MODE button to select the DIODE mode. The Diode symbol will appear in the display. 6. Press the MODE button to select the Continuity mode. The continuity symbol will appear in the display. If the resistance is <150 ohms the tone will sound. 6

Capacitance Measurements WARNING: To avoid electric shock, discharge the capacitor before measuring. 1. Rotate the function switch to the CAP capacitance position. 2. Insert the black test lead banana plug into the negative COM jack. Insert the red test lead banana plug into the positive jack. 3. Touch the black test probe tip to one side of the device. Touch the red test probe tip to the other side of the device. 4. Read the capacitance value in the display. Type K Temperature Measurements 1. Rotate the function switch to the F or C temperature position. 2. Insert the Temperature Probe into the input jacks. 3. Place the temperature probe tip(s) where needed. 4. Read the temperature on the display. Note: In case of an open input or a temperature overrange, the meter will display OL. Data Hold To freeze the LCD reading, press the HOLD button. The HOLD icon appears on the LCD. Press the HOLD button again to return to normal operation. Relative Press the REL button (REL will appear in the display) to zero the reading and create a reference point. All future reading will be the difference between the actual reading and the stored REL reading. In the REL mode, autoranging is disabled and measurements are limited to the range active when the REL button was pressed. Press the REL button to exit the mode. Note: Relative does not function in Frequency or Duty Cycle mode. Automatic Power Off In order to conserve battery life, the meter will automatically turn off after approximately 30 minutes. To turn the meter on again, change the position of the function switch. Low battery indication When the icon appears in the display, the battery should be replaced. Refer to the battery replacement procedure in the maintenance section. 7

Maintenance WARNING: To avoid electrical shock, disconnect the meter from any circuit, remove the test leads from the input terminals, and turn OFF the meter before opening the case. Do not operate the meter with an open case. Cleaning and Storage Periodically wipe the case with a damp cloth and mild detergent; do not use abrasives or solvents. If the meter is not to be used for 60 days or more, remove the battery and store it separately. Battery Replacement 1. Remove the 2 Phillips head screws that secure the rear battery cover 2. Open the battery compartment 3. Replace the 2 AAA 1.5V batteries. 4. Secure the battery compartment door All EU users are legally bound by the Battery Ordinance to return all used batteries to community collection points or wherever batteries / accumulators are sold! Disposal in household trash or refuse is prohibited! Disposal: Follow the valid legal stipulations in respect of the disposal of the device at the end of its lifecycle. 8

Specifications Accuracy (% of reading + digits) 40.00 AAC 0.01A ±(2.5% + 12 digits) 400.0 AAC 0.1A ±(2.8% + 8 digits) AC Current ranges specified from 5% to 100% of range 4.000 VAC 0.001V 40.00 VAC 0.01V ±(1.8% + 10 digits) 400.0 VAC 0.1V Function Range Resolution AC Current 50/60Hz AC Voltage 50 to 400Hz DC Voltage Resistance Capacitance Frequency Duty Cycle Temperature Type K 600 VAC 1V ±(2.5% + 10 digits) AC Voltage ranges specified from 5% to 100% of range 400.0 mvdc 0.1mV ±(0.8% + 2 digits) 4.000 VDC 0.001V 40.00 VDC 0.01V 400.0 VDC 0.1V ±(1.5% + 2 digits) 600 VDC 1V ±(2.0% + 2 digits) 400.0 0.1 ±(1.0% + 4 digits) 4.000k 40.00k 400.0k 0.001k 0.01k 0.1k ±(1.5% + 2 digits) 4.000M 0.001M ±(2.5% + 3 digits) 40.00M 0.01M ±(3.5% + 5 digits) 40.00nF 0.01nF ±(4.0% + 20 digits) 400.0nF 40.00µF 100.0µF 0.1nF 0.01µF 0.1µF ±(3.0% + 5 digits) 10 to 10kHz 0.01Hz ±(1.5% + 2 digits) Sensitivity: 15V rms 0.5% to 99.0% 0.1% ±(1.2% + 2 digits) Pulse width: 100s to 100ms, Frequency: 10Hz to 10kHz -4.0 to 1400 F -20 to 760 C 0.1 <400 1 >400 ±(3% + 9 F/5 C) Specification does not include probe accuracy. Range of supplied probe is -4 to 482 F (-20 to 250 C). 9

General Specifications Clamp jaw opening 30mm (1.18") approx. Display 4,000 count LCD Continuity check Threshold <150; Test current < 0.5mA Diode test Test current of 0.3mA typical; Open circuit voltage 1.5VDC typical Low Battery indication Battery symbol is displayed Over-range indication OL display Measurement rate 2 readings per second, nominal Thermocouple sensor Type K thermocouple required Input Impedance 10M (VDC and VAC) AC bandwidth 50 to 400Hz (VAC) AC response True rms Operating Temperature 5C to 40C (41F to 104F) Storage Temperature -20C to 60C (-4F to 140F) Operating Humidity Max 80% up to 31C (87F) decreasing linearly to 50% at 40C (104F) Storage Humidity <80% Operating Altitude 2000meters (7000ft) maximum. Battery Two AAA 1.5V batteries Auto power OFF After approx. 30 minutes Dimensions & Weight 200x66x37mm (7.9x2.6x1.5 ); 205g (7.23oz) Safety For indoor use and in accordance with the requirements for double insulation to IEC1010-1 (2001): EN61010-1 (2001) Overvoltage Category III 600V, Pollution Degree 2. Approvals CE, Copyright 2012 Extech Instruments Corporation (a FLIR company) All rights reserved including the right of reproduction in whole or in part in any form ISO-9001 Certified www.extech.com 10