Digital Interface Card DEC005000

Similar documents
Potentiometer Control EC20200

Sealed Interface Control: EC20300

TECHNICAL DATASHEET #TD1400AX PWM Controlled Solenoid Driver (DIN rail mount) P/N: PWMC-DR-2A, PWMC-DR-1.2A

Coils & Electronic Controls

ELECTRONIC REGULATOR FOR OPEN LOOP

Apitech Valve Drive Board

Precision Voltage Control System

815-BR SERVO AMPLIFIER FOR BRUSH SERVOMOTORS

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B

DENISON HYDRAULICS Proportional Pressure Control Valves

AMC-100 AMC-101 AMC-100 AMC-100B AMC-100D AMC-101 AMC-101B AMC-101D AMC-100A AMC-100C AMC-100E AMC-101A AMC-101C AMC-101E. AC Motor Controllers

TECHNICAL DATASHEET #TDAX INPUTS, 5 OUTPUTS VALVE CONTROLLER

Electronic amplifier for the control of proportional valves without position control Model VT 3006, Series 3X H/A 4240/94 VT X

AD-8100 & AD-8200 Servo Amplifiers

EPA-M*** POWER AMPLIFIER FOR OPEN LOOP PROPORTIONAL VALVES SERIES 20

PROPORTIONAL PRESSURE CONTROLS TECNORD

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

with Electronic Assistant

INSPECTION 1. Take the cover off the relay, taking care to not shake or jar the relay or other relays around it.

MCHXXX. Simple to install MECHANICAL. HANDLE STROKE ± 30 (60 total travel)

YVPC ELECTRONIC REGULATOR FOR PWM CONTROLLED SOLENOID

BME/ISE 3511 Bioelectronics I - Laboratory Exercise #4. Variable Resistors (Potentiometers and Rheostats)

1525-BRS INFORMATION MANUAL SERV O D YN A M ICS. D y n ad r iv e Ave Crocker Suite 10 Valencia, CA

DENISON HYDRAULICS Multi-Function Proportional Valve Dual Driver ( Encapsulated )

DynaDrive INFORMATION MANUAL SDFP(S)

P o w e r. C O N T R O L S A N D a t h e n a c o n t r o l s. c o m. ATHENA CONTROLS, INC Campus Drive Plymouth Meeting, PA U.S.A.

Electronic amplifier for the control of proportional valves without position control Model VT 3024, Series 3X H/A 4149/94 VT X

FT201 PRODUCT MANUAL PART NUMBER: SG REVISION: A

Electronic regulator for PWM controlled proportional solenoid valves FABER -

TECHNICAL DATASHEET #TDAX Universal Input, Single Output Valve Controller CAN (SAE J1939)

Electronic Amplifier Model VT 3017 and VT 3018 (Series 3X) for the control of proportional directional valves, without positional feedback

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8" to 1/2" NPT. Proportional Valves. Features.

P/N: AX TECHNICAL DATASHEET #TDAX Single Input, Dual Output Valve Controller 1 Universal Input, +5V reference CAN (SAE J1939)

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

PHASE CUT SIGNAL DRIVERS

TECHNICAL DATASHEET #TDAX INPUT, 12 OUTPUT VALVE CONTROLLER,

DeviceCraft Revision #1 11/29/2010

Built-in soft-start feature. Up-Slope and Down-Slope. Power-Up safe start feature. Motor will only start if pulse of 1.5ms is detected.

Analog amplifier RA. RE Edition: Replaces:

Electro Controls. Input-Output Modules WattsIndustries.co.uk

Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet

Digital amplifier for proportional valves PEM XD

PROPORTIONAL PRESSURE CONTROLS TECNORD

Applications: oil and gas equipment automation; off-highway machine automation; agricultural equipment

DVC700 Series Programmable System Controller

MDSD (Series 2X) Mobile Dual Solenoid Driver

Controller. 1 Proportional amplifier module ESSK 103. ESSK 103 and ELSK Description. 1.2 Application examples. 1.

PreLab 6 PWM Design for H-bridge Driver (due Oct 23)

HAU Series Controllers

KEY FEATURES. Selectable modes of control : Phase Angle or Burst Fire (Single- Cycle/Dual-Cycle & adjustable STD Burst Firing)

HT101V Reference Manual

Electronic plugs for valves MSE

T6+ Analog I/O Section. Installation booklet for part numbers: 5/4-80A-115 5/4-90A-115 5/4-80A /4-90A-1224

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/4" to 1/2" NPT. Proportional Valves. Features.

Valve amplifier for proportional directional valves and proportional pressure valves. Type VT-VSPA2-1. Features. Contents

EMA Series, EMC Series

Overview. Features. Specifications. Important Notes

DVC700 Series Programmable System Controller

Owner s Manual S10 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL

40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR

4/3 Proportional Directional Valve, Size SAE 10

MODEL AT-10 ANALOG TRANSMITTER

Accessories Power Amplifiers

Drive electronics pq11

Catalog HY /US SERIES DESCRIPTION PAGE NO. SUPER COILS CC... 1/2 Solenoid Tubes... CE3-CE4 CA... 5/8 Solenoid Tubes...

EXAMPLE. Use this jack for the red test lead when measuring. current from 0 to 200mA. Figure P-1

Continental Hydraulics Installation Manual CEM-RA-A

PART # mA Positioner

TECHNICAL DATASHEET #TDAX022420

SERIES 70. R SERVO PRO Version 3.0 OPERATION AND MAINTENANCE MANUAL. The High Performance Company

SITRANS F flowmeters. SITRANS F R Rotary-piston meters Accessory modules 4/431. Overview. Siemens AG 2009

Operator Manual 1.4 FRACSIM MINI

TECHNICAL DATASHEET #TDAX A DC MOTOR CONTROLLER P/N: AX Variable Speed Control, Onboard I/O CAN SAE J1939, Rugged Packaging

AMC mA Positioner

MAE3. Absolute Magnetic Kit Encoder Page 1 of 8. Description. Mechanical Drawing. Features

RENATO DESIRÒ PARABIAGO (MI) Via Sant Anna, 51 Tel Fax

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Sensors Q625A Remote Setpoint Module

Continental Hydraulics Installation Manual CEM-PA-A

Drive Electronics pq11

Section 11 Electronic Position Controls & Encoders

FC Series Signal Conditioners

Proportional Directional Control Valves Series D1FB. General Description. Features. D1FB*3 OBE Spool/Body Design. D1FB*0 OBE Spool/Sleeve Design

BFS / BFSM SERIES Installation & Maintenance Manual

Installation Tech Note Dallas, Texas

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

10 Amp Digital PWM Motor Speed Controller CV-2110-HD and CV-2110-HDS

DPC-100LC. Proportional Valve Driver. Features. Applications

Spring Return DuraDrive Proportional Actuator

MODEL KBWD-15 Pulse Width Modulated (PWM)

MicroManager. Velocity Mode PID Dancer/Loadcell Control. Instruction Manual MM3000-PID

with Electronic Assistant

S1 Programming Chart Program Description S1 Switch Positions. Constant ON High/Low Track, WR

INSTALLATION AND OPERATION MANUAL IODA INPUT/OUTPUT MULTI-FUNCTION BOARD (Part No. 9668)

Your Global Flow Control Partner. Series 70 SERVO PRO Version 3.0 Operation and Maintenance Manual

J1 Line APPLICATION FEATURES DESCRIPTION RUGGED-DUTY SHAFTED ENCODERS

TECHNICAL DATASHEET #TDAX QUAD VALVE CONTROLLER P/N: AX SERIES

Thornwood Drive Operating Manual: Two-SCR General Purpose Gate Firing Board FCRO2100 Revision H

Current consumption ma solenoid current consumption ( max 300 ma) Hz % V ma. Housing dimensions mm 120(d) x 99(h) x 23(w)

Service Instructions. The Conductor Controls. Conductor DC15-A, Enclosed Unit CH15-A, Open Chasis Unit

Transcription:

Engineering & Manufacturing Solutions Digital Interface Card DEC005000 APPLICATION: The DEC005000 conveniently interfaces industry standard signals 4-20mA, 0-5V or 0-10V with a proportional solenoid valve ISO 9001:2008 WITH DESIGN Certificate #02.002.1

Features / Description / Specifications DEC005000Digital Interface Card FEATURES: Din rail mount, Din35 and Din 32. Reverse polarity protection. Active, short circuit monitoring and lockout. Open load detection. Diagnostic indicator. Pulse Width Modulated Output. Current controlled output, maintains output current regardless of supply voltage and coil resistance variations. Capable of accepting four industry standard signal types: Potentiometer, 0-10V, 0-5V, or 4-20mA. Reference voltage provided for control via an external potentiometer. Two Enable lines are provided, one with adjustable soft stop, both with adjustable soft start. (See details on page 4) Independent ramp adjustments up and down (0.1-30s). Maximum and minimum current adjustments completely independent of one another. Wide voltage supply range (9-30V) for 12V or 24V systems. Full, industrial temp spec (-40 C - 85 C) operation. DESCRIPTION: The DEC005000 has been designed to meet the various requirements of mobile and industrial hydraulic control applications. DEC005000 cards are versatile, cost effective and easily integrated into new or pre-existing designs. Much of this is a result of the unique ability each card has to accept 4 different signals. The DEC005000 can accept any of the following input types: Potentiometer, 0-10V, 0-5V, or 4-20mA. The card takes these signals and converts them into a PWM output suitable for a Brand EFC-Series valve or other proportional valves that meet the proper specifications. SPECIFICATIONS: Voltage Supply Operating Temperature Storage Temperature Max Continuous Output Current Overcurrent Lockout Current Short Circuit Lockout Current 9-30 VDC -40 C - 85 C (-40 F - 176 F) -40 C - 85 C (-40 F - 176 F) 3.0 Amps 4.5 Amps 5.0 Amps A-107 REV(D)

Output Type PWM, Pulse Width Modulation, 0-100% Duty cycle PWM Output Frequency 30Hz - 500Hz +/- 5 Hertz (Factory Set) Weight, fully assembled 0.151kg (0.332lb.) INPUT SPECIFICATIONS: Potentiometer Terminal block 2, Pin 7 Wiper Input Impedance 10K Ohms Wiper Input range.6v - 4.4V Resistance 10K Ohms Minimum Power rating 1/8th Watt Maximum Operating Input Voltage 7.2V +/-.5V (Higher voltages will lock out input) Maximum Protected Input Voltage 30V 0-10 Volt Input Terminal block 2, Pin 9 Input Impedance 10K Ohms Step response Output current will equal: ((Input voltage x 0.1) (max current - min current)) + (min current) For every volt of input, output will change 1/10 its full range. Maximum Operating Input Voltage 12.3V +/-.5V (Higher voltages will lock out input) Maximum Protected Input Voltage 30V 0-5 Volt Input Terminal block 2, Pin 10 Input Impedance 10K Ohms Step response Output current will equal: ((Input voltage x 0.2) (max current - min current)) + (min current) For every volt of input, output will change 1/5 its full range. Maximum Operating Input Voltage 7.8V +/-.5V (Higher voltages will lock out input) Maximum Protected Input Voltage 30V 4-20mA Input Terminal block 2, Pin 11 Input Impedance 250 Ohms Step response Output current will equal: ((Input current - 4mA) (0.0625) (max current - min current)) + (min current) For every milliamp of input, output will change 1/16 its full range. Maximum Operating Input Voltage 8.0V +/-.5V (Higher voltages will lock out input) Maximum Protected Input Voltage 30V Enable Input When Enable is left open (high) the unit is operational. When the enable line is connected to ground (low) the board output immediately goes to 0 Amps. Impedance 560K Ohms High state REN pin voltage 4.61V +/- 0.1V Output Type / Input Specifications A-108

Input Specifications / Adjustments DEC005000Digital Interface Card Source current while pulled low 3.67mA Ramping Enable Input When Enable is left open (high) the unit is operational. When the enable line is connected to ground (low) the board output ramps down to the minimum output setting at the rate set by ramp adjustments. Impedance 560K Ohms High state REN pin voltage 4.61V +/- 0.1V Source current while pulled low 3.67mA Auxiliary Output Terminal block 1, Pin 2 Maximum Current 2.5A ADJUSTMENTS: Minimum output or zero setting Maximum output Ramping Down or Fall Ramping Up, or Rise Clockwise rotation increases minimum output 0.1-3 Amps Maximum output will always be 50mA greater than the minimum output Clockwise rotation increases maximum output 0.1-3 Amps Maximum output will always be 50mA greater than the minimum output Clockwise rotation increases ramp time 0.1-30 Seconds, Clockwise rotation increases ramp time 0.1-30 Seconds ADJUSTMENT PROCEDURE: Adjustments are made by turning a trim pot screw. The trimmers are 25 turn, end to end devices. The trimmers have a built in slip clutches so over rotations do not damage them. It may be necessary to turn the adjustment screw several turns to observe a change in output. Start by adjusting the min output, and then adjust the max output to the desired level. The best way to fine tune adjustments is to observe the function response or speed. It is important to make adjustments in the following order. 1. Minimum output: Start by setting the master Potentiometer or input signal to zero. Turn the trimmer clockwise until the function begins to move. Now turn the trimmer back counter clockwise, one full rotation past the point of any visible movement. 2. Maximum output: Start by setting the master Potentiometer to the 100 position on the dial. Turn the trim pot counter clockwise to decrease function speed. Turn the trim pot clockwise to increase function speed. Function maximum speed will be limited to the max flow capabilities of your hydraulic system. Do not rotate the trim pot past the point of an observable increase in function speed. A-109 REV(D)

3. Ramp up: This feature changes how quickly the valve can open. Clockwise turns increase the amount of delay. Counterclockwise turns decrease the amount of delay. 4. Ramp down: This Feature changes how quickly the valve can close. Clockwise turns increase the amount of delay. Counterclockwise turns decrease the amount of delay. Use discretion when making this adjustment, this will affect how quickly your function stops. MIN/MAX Adjustments Ramping Adjustments / Enable Inputs Offset = MIN trim Signal Input Control Output Slope = MAX trim Control Output Control Input Signal Rise Fall ENABLE INPUTS: The Enable Inputs can be used to turn the controllers output on and off, without having to switch on/off the main power source. The DEC005000 cards are supplied with two unique types of Enable inputs, EN and REN. When the EN line is switched to ground the control will go into sleep mode. It will be as if the controls power source has been turned off. When the EN line is switched back to its normal state, open to ground, the control output will again respond to user input. A soft start can be achieved using the controllers Ramp Up adjustment. The Ramping enable input, REN, allows for soft start and soft stop enabling. The REN input is also activated by being switched to ground. When the REN is activated the control will respond as if the user input signal has been turned off and the controls output will ramp down to the set minimum output value. When the REN input is returned to its normal state the control output will ramp up to the output level that corresponds with the user input signal. Soft start ramp and Soft stop ramp times are set using the onboard trim pots that are labeled UP and DOWN. Enable Ramping Enable Enable Input Ramping Enable Input üüü Output üüü Output Rise Rise Fall A-110

Typical System Configurations DEC005000Digital Interface Card TYPICAL SYSTEM CONFIGURATIONS: Note: Inputs are additive when two or more are used simultaneously. Other configurations are possible, contact factory for more information. A-111 REV(D)

DEC/EFC - SERIES SCHEMATIC DRAWING: Schematic Drawing / Dimensional Data DIMENSIONAL DATA: inches & [millimeters] A-112

Internal Layout DEC005000 INTERNAL LAYOUT: REV(D) A-113 Digital Interface Card

OUTPUT: Output / Parts And Accessories Note: All the above readings were taken with the DEC005000 adjusted for a.5 Amp maximum output at 100 Hz. A 14.6V supply was used for 12V coil tests and a 26V supply was used for 24V coil tests. EC - ACCESSORIES: E1049...Panel mount fuse holder E1050...Knob, Black E1071...Potentiometer shaft seal E1747...Power switch, SPST, screw terminals E1758...Switch boot seal E1803...Long Life Potentiometer, 10K w/ 6 Leads A-114