Float Switches with Permanent Magnet For Vertical Installation Model RSM

Similar documents
Float switch For industrial applications, plastic version Model RLS-2000

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Absolute pressure gauge with output signal For the process industry Models APGT and APGT43.160, NS 100 and 160

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Mechatronic pressure measurement. Applications. Special features. Description

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

Gas-actuated combi-thermometer with Pt100 electrical output signal Model 76, stainless steel version

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Resistance thermometer Model TR30, compact design

Resistance thermometer Model TR30, compact design

KFS. Flap-type flow meter. Design and range of application

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Submersible pressure sensor For oils and fuels Model LF-1

Submersible pressure sensor For water and wastewater Model LW-1

In-Line Resistance Thermometers Model TR25

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Resistance Thermometers Model Series TR7X0, Sheathed Design

Miniature resistance thermometer Model TR33, thread-mounted

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Design and applications

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Submersible pressure sensor For superior applications Model LF-1

Indicator for panel mounting Model

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

KSR Magnetostrictive Level Transmitters (High Accuracy)

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

Resistance thermometers for process technology

Flush pressure transmitter For viscous and solids-containing media Model S-11

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Resistance thermometer Model TR30, compact design

Field indicator for current loops with HART communication Models DIH50, DIH52

Resistance thermometer Model TR31, miniature design

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Field indicator for current loops with HART communication Models DIH50, DIH52

Level sensor Magnetostrictive, high-resolution measuring principle For sanitary applications, model FLM-H

Miniature resistance thermometer For sanitary applications Model TR21-B, for orbital welding

Pressure transmitter For general industrial applications Model A-10

Electrical Temperature Measurement

Level gauges Series LT Level indicator, switch and transmitter for liquids

Page Type Resolution (mm) min. max. Output

Pressure transmitter For sanitary applications Model SA-11

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

FLOAT LEVEL SENSOR TFC. Applications. Reference. Features

Pressure transmitter For general industrial applications Model A-10

Metal tube variable area flowmeters for gases, liquids and steam

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Miniature resistance thermometer For sanitary applications, for orbital welding Model TR21-B

Magnetic level switches ERH-xx-20

Electrical Alarm Contacts

Target disk flowmeter for liquids and gases

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases

Pressure transmitter for general industrial applications Model A-10

Electronic temperature switch with display Model TSD-30

Miniature resistance thermometer For sanitary applications Model TR21-C, with integrated sterile connection

Electrical Alarm Contacts

Pressure transmitter for general industrial applications Model A-10

High-quality pressure transmitter For general industrial applications Model S-10

Level and Pressure. Product Information. Vibrating level switches

OEM pressure transmitter For mobile working machines Model MH-3

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

Digital indicator for panel mounting With multi-function input Model DI25

Process pressure transmitter Model IPT-10, standard version Model IPT-11, flush diaphragm

OPTIFLUX 5000 Technical Datasheet

KFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite

Ultra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26

In-line resistance thermometer Model TR25

SALES SERVICE +358 (0)

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

TMU. Coriolis Mass Flow Meter. for liquids and gas

Tension/compression force transducer. With thin film technology up to 100 kn. Models F2301, F23C1, F23S1. Force. Applications.

ECHOTEL 961/962. Ultrasonic level switches. Loop or line powered D E S C R I P T I O N F E AT U R E S A G E N C Y A P P R O VA L S

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

Technical Information Condumax CLS21D/CLS21

FOR RELIABLY MEASURING +

Load pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1

OPTIMASS 1000 Technical Datasheet

LEVEL SWITCH CATALOGUE

OEM radar transmitter, for aggressive media level measurement

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

OPTIFLUX 5000 Technical Datasheet

Coriolis Massflowmeter

INSTALLATION AND OPERATION MANUAL

ECHOTEL 915 series. 2 Wire, current shift Ultrasonic level switch. Worldwide level and flow solutions DESCRIPTION. Compact and universal level switch

Digital inductive conductivity transmitter

Level Switch Catalogue

MEGGITT MOBREY LTD. MOBREY SQUING Vibrating fork liquid level switch. Product data sheet IP202

Inductive sensor slot-type SI2-K08-AP7

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Process Automation. Sensors and Systems: Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors

Safety Instructions Nivotester FTC625, FTC325

Condumax CLS21 and CLS21D

TIDALFLUX 2300 F Technical Datasheet

Hand-held temperature calibrator Model CEP3000

Condumax W CLS15 and CLS15D

Liquid Level Switches

Transcription:

Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring for defined filling levels Chemical industry, petrochemical industry, natural gas, offshore, shipbuilding, machine building, power generating equipment, power stations Process water and drinking water treatment, food and beverage industry Special Features Large scope of application due to the simple, proven functional principle For harsh operating conditions, long service life Operating limits: - Operating temperature: T = -196... +300 C - Working pressure: P = vacuum to 100 bar - Limit S. G.: 400 kg/m 3 Wide variety of different electrical connections, process connections and materials Explosion-protected versions Description A float with a permanent magnet moves reliably along with the liquid level on a guide tube. Within the guide tube is fitted a reed contact (inert gas contact), which is energised, through the non-magnetic walls of the float and guide tube, by the approach of the float magnet. By using a magnet and reed contact the switching operation is non-contact, free from wear and needs no power supply. The contacts are potential-free. WIKA float switches with permanent magnets are also available with several switch points. Float Switches with Permanent Magnet, for vertical installation, Model RSM Fig. left: Stainless steel version, mounting thread Fig. right: Plastic version, flange connection The switch functions always refer to a rising liquid level: normally open / normally closed / change-over contacts. Through the use of a float for a max. of switch points a bistable switch operation can be achieved, meaning that the switching status also remains available, when the filling level continues to rise above or drop below the switch point. The float switch is simple to mount and maintenance-free, so the costs of mounting, coissioning and operation are low. Page 1 of 14 Data Sheets showing similar devices: Float Switches with Permanent Magnet, horizontal installation; Model HIF; see data sheet LM 30.0 Float Switches with Permanent Magnet, lateral mounting; Model RSB; see data sheet LM 30.03

Further special features Process connection, guide tube material and float made of stainless steel 1.4571 or plastic Universal signal processing: connection direct to a PLC is possible, NAMUR connection, signal amplification / contact protection relays Works independently of foaming, conductivity, dielectricity, pressure, vacuum, temperature, steam, condensation, blistering, boiling effects and vibrations Multiple functionality in a single instrument - up to 8 potential-free contacts Exact repeatability of the switch points Float switches with permanent magnets qualify as passive electrical equipment in accordance with DIN IEC 60 079-11 and can be installed in 'Zone 1' hazardous areas without certification, so long as the equipment is operated in a certified intrinsically safe circuit with a minimum explosion protection of EEx ib Options Customer-specific solutions Specific designs for interface layer detection - 50 kg / m 3 Process connection, guide tube material and float made of stainless steel 1.4435, 1.4539, titanium, Hastelloy (others on request) Page of 14

Application examples Level switch (EEx i) Intrinsically safe Intrinsically safe Intrinsically safe relay e.g.: KR 4 Ex Intrinsically safe relay e.g.: KR 4 Ex Ex zone non Ex zone Ex zone non Ex zone Level control (min.-max. control) Contact protection relay e.g.: KR 30 Contact protection relay e.g.: KR 4 Product prograe Selection of process connection, material and design further information on the indicated pages. Process connection Material Explosion-protected Material Stainless steel version PVC / PP / PVDF (without terminal box) G 1/8"... G " Page 4 Page 5 (adjustable guide tube) Page 7 (Mini float) - Page 8 G 1/"... G " Page 4 Page 5 (adjustable guide tube) Page 7 (Mini float) Page 6 Page 8 Flange DN 50... DN 00 PN 6... PN 100 Page 4 Page 5 (adjustable guide tube) Page 9 (E-CTFE coated) Page 6 Page 8 Float versions: page 10 and 11 Contact protection measures: page 1 Connection diagrams: page 13 and 14 Page 3 of 14

Standard version Process connection, guide tube material and float made of stainless steel 1.4571 Connection cable (without terminal box) Flange Electrical connection Process connection Connection cable PVC grey PVC blue PUR upwards G 3/8" (others on request) G 1/" (others on request) downwards G 1 1/" or G " Aluminium 64 x 58 x 34, with 1 contact Aluminium 80 x 75 x 57, or more contacts Option: Polypropylene, polyester, stainless steel Mounting flange DN 50... DN 00, PN 6... PN 100 ANSI "... 8", Class 150... 600 Guide tube diameter 1 or 14 18 1 or 14 18 1 or 14 18 Guide tube length L max. 3000 6000 3000 6000 3000 6000 Float Temperature range standard Material stainless steel 1.4571 (Option: Buna, titanium) Float diameter from 44... 10 Float selection depending on guide tube diameter and process conditions (see page 10 and 11) PVC / PUR cable -10... +80 C Silicone cable -30... +150 C -30... +150 C Option: High temperature version: +150... +300 C Option: Low temperature version: -196... -30 C Switch function Max. number of contacts Switch position Distance between switch points Optionally contact makes S, contact breaks O or change-over U - at increasing level PVC cable 6 x S or O, or 4 x U Silicone cable 5 x S or O, or 3 x U 6 x S or O, or 4 x U Dimensions L 1, L, L 3... (from sealing face, starting from top) Minimum 0 (depending on the selection of the float and the contacts, see page 10 and 11) Contact rating Contact makes 30 V AC; 100 VA; 1 A 30 V DC; 50 W; 0.5 A Contact breaks 30 V AC; 100 VA; 1 A 30 V DC; 50 W; 0.5 A Please observe contact protection measures (see page 1)! Change-over 30 V AC; 40 VA; 1 A 30 V DC; 0 W; 0.5 A Attention: Versions without protective earth conductor - operation only at safety extra-low voltage e.g. WIKA contact protection relay or external earthing Mounting position Vertical ± 30 Ingress protection IP 65 per EN 60 59 / lec 59 Page 4 of 14

Version with adjustable guide tube Process connection, guide tube material and float made of stainless steel 1.4571 guide tube adjustable by loosening union nut Connection cable 7 flats guide tube adjustable by loosening union nut 7 flats guide tube adjustable by loosening union nut 7 flats 14 G 1/" (without terminal box) Flange Electrical connection Process connection Guide tube diameter Guide tube length L max. Float Nominal pressure Temperature range standard Switch function Max. number of contacts Switch position Distance between switch points Connection cable PVC grey PVC blue PUR upwards G 1/" (others on request) Aluminium 64 x 58 x 34, with 1 contact Aluminium 80 x 75 x 57, or more contacts Option: Polypropylene, polyester, stainless steel downwards G 1 1/" or G " (others on request) 1 3000 Material stainless steel 1.4571 (Option: Buna, titanium) Float diameter from 44... 83 Float selection depending on guide tube diameter and process conditions (see page 10 and 11) 5 bar PVC / PUR cable -10... +80 C Silicone cable -30... +150 C -30... +150 C Optionally contact makes S, contact breaks O or change-over U - at increasing level PVC cable 6 x S or O, or 4 x U Silicone cable 5 x S or O, or 3 x U 6 x S or O, resp. 4 x U Dimensions L 1, L, L 3... (from sealing face, starting from top) Minimum 0 (depending on the selection of the float and the contacts, see page 10 and 11) Mounting flange DN 50... DN 00, PN 6... PN 100 ANSI "... 8", Class 150... 600 Contact rating Contact makes 30 V AC; 100 VA; 1 A 30 V DC; 50 W; 0.5 A Contact breaks 30 V AC; 100 VA; 1 A 30 V DC; 50 W; 0.5 A Please observe contact protection measures (see page 1)! Change-over 30 V AC; 40 VA; 1 A 30 V DC; 0 W; 0.5 A Attention: Versions without protective earth conductor - operation only at safety extra-low voltage e.g. WIKA contact protection relay or external earthing Mounting position Vertical ± 30 Ingress protection IP 54 per EN 60 59 / lec 59 IP 65 per EN 60 59 / lec 59 Page 5 of 14

Explosion-protected version, intrinsically safe II 1/G EEx ia IIC T3-T6 KEMA 09 ATEX 018X II D T80 C IP6X Process connection, guide tube material and float made of stainless steel 1.4571 X X Process temperature Raised terminal box X < 60 C 0 < 135 C 60 < 180 C 80 Flange Electrical connection Aluminium 80 x 75 x 57 Option: Polyester, stainless steel Process connection downwards G 1 1/" or G " (others on request) Mounting flange DN 50... DN 150, PN 6... PN 64 ANSI "... 6", Class 150... 600 Guide tube diameter 1 or 14 18 1 or 14 18 Guide tube length L max. 3000 6000 3000 6000 Float Temperature class Process temperature Ambient temperature at terminal box Material stainless steel 1.4571 (Option: Buna, titanium) Float diameter from 44... 10 Float selection depending on guide tube diameter and process conditions (see page 10 and 11) T3 T4 T5 T6 Max. 180 C 130 C 95 C 80 C Max. 60 C 60 C 60 C 60 C Switch function Max. number of contacts Switch position Distance between switch points Contact rating Optionally contact makes S, contact breaks O or change-over U - at increasing level 6 x S or O, or 4 x U Dimensions L 1, L, L 3... (from sealing face, starting from top) Minimum 0 (depending on the selection of the float and the contacts, see page 10 and 11) Only for connection to a certified intrinsically safe circuit with U max 36 V, I max 100 ma Mounting position Vertical ± 30 Ingress protection IP 65 per EN 60 59 / lec 59 Options Temperature resistance Pt100 or Pt1000 Bimetal thermal contact 40... 10 C (in 5 degree steps) Page 6 of 14

Mini float version Process connection and guide tube material made of stainless steel 1.4571 Coupler connector ASC4 M1 x 1 Connection cable 1 G 1/8" 7 flats (without terminal box) Electrical connection Connection cable PVC grey PVC blue Silicone PUR Aluminium 64 x 58 x 34 Coupler connector Coupler connector Process connection upwards G 1/8" (others on request) downwards oder G 1" (others on request) Guide tube diameter 8 Guide tube length L max. 500 Float Temperature range Switch function Max. number of contacts Material stainless steel 1.4571 (Option: Buna, polypropylene, titanium) Float diameter from 3... 9 Float selection depending on guide tube diameter and process conditions (see page 10 and 11) -10... +100 C (Float material stainless steel or titanium) -10... +80 C (Float material Buna or polypropylene) Optionally contact makes S, contact breaks O or change over U - at increasing level 3 x S or O, or 1 x U Contact rating Contact makes 50 V AC; 10 VA; 0.5 A 50 V DC; 5 W; 0.5 A Contact breaks 50 V AC; 10 VA; 0.5 A 50 V DC; 5 W; 0.5 A Please observe contact protection measures (see page 1)! Change-over 8 V AC; 6 VA; 0.6 A 8 V DC; 3 W; 0.3 A Attention: Versions without protective earth conductor - operation only at safety extra-low voltage e.g. WIKA contact protection relay or external earthing Mounting position Vertical ± 30 Ingress protection IP 54 per EN 60 59 / lec 59 IP 65 per EN 60 59 / lec 59 Page 7 of 14

Plastic version Process connection, guide tube material and float made of PVC, polypropylene or PVDF Guide tube Ø 1 Connection cable 1 G 3/8" flats M0 x 1.5 M0 x 1.5 Guide tube Ø 16 Connection cable 14 G 1/" 7 flats Guide tube Ø 0 Connection cable 4 G 1" 3 flats (without terminal box) Flange Electrical connection Process connection Guide tube diameter Guide tube length L max. Connection cable PVC grey PVC blue PUR, upwards G 3/8" (Guide tube Ø 1 ) G 1/" (Guide tube Ø 16 ) G 1" (Guide tube Ø 0 ) (others on request) Polypropylene 80 x 8 x 55, downwards G 1 1/" or G " (others on request) 1, 16 or 0 (16 and 0 : strengthened with a metallic inner tube) 500 (Guide tube Ø 1 ) 3000 (Guide tube Ø 16 ) 5000 (Guide tube Ø 0 ) Mounting flange DN 50... DN 15, PN 10, Form A ANSI "... 5", Class 150 FF Float Material PVC Float diameter from 44... 80 Float selection depending on guide tube diameter and process conditions (see page 11) Temperature range PVC 0... +60 C -10... +80 C -10... +100 C Switch function Optionally contact makes S, contact breaks O or change-over U - at increasing level Max. number of 4 x S or O (PP max. 3) resp. 3 x U (PP max. ) contacts Switch position Dimensions L 1, L, L 3... (from sealing face, starting from top) Distance between Minimum 0 (depending on the selection of the float and the contacts, see page 11) switch points Contact rating Contact makes 30 V AC; 100 VA; 1 A 30 V DC; 50 W; 0.5 A Contact breaks 30 V AC; 100 VA; 1 A 30 V DC; 50 W; 0.5 A Please observe contact protection measures (see page 1)! Change-over 30 V AC; 40 VA; 1 A 30 V DC; 0 W; 0.5 A Attention: Versions without protective earth conductor - operation only at safety extra-low voltage e.g. WIKA contact protection relay or external earthing Mounting position Vertical ± 30 Ingress protection IP 54 per EN 60 59 / lec 59 IP 65 per EN 60 59 / lec 59 Page 8 of 14

Stainless steel version, E-CTFE coated Process connection, guide tube material and float made of stainless steel 1.4571, E-CTFE coated Flange (Guide tube diameter 1 ) Flange (Guide tube diameter 18 ) Electrical connection Aluminium 64 x 58 x 34, with 1 contact Aluminium 80 x 75 x 57, or more contacts Option: Polypropylene, polyester, stainless steel Process connections Mounting flange DN 50... DN 00, PN 6... PN 40 ANSI "... 8", Class 150... 300 Guide tube diameter 1 18 Guide tube length L max. 000 4000 Float Temperature range Switch function Max. number of contacts Switch position Distance between switch points Material stainless steel 1.4571 (E-CTFE coated) Float diameter from 45... 11 Float selection depending on guide tube diameter and process conditions (see page 10) Depending on medium Optionally contact makes S, contact breaks O or change-over U - at increasing level 3 x S or O, resp. x U Dimensions L 1, L, L 3... (from sealing face, starting from top) Minimum 0 (depending on the selection of the float and the contacts, see page 10) Contact rating Contact makes 30 V AC; 100 VA; 1 A 30 V DC; 50 W; 0.5 A Contact breaks 30 V AC; 100 VA; 1 A 30 V DC; 50 W; 0.5 A Please observe contact protection measures (see page 1)! Change-over 30 V AC; 40 VA; 1 A 30 V DC; 0 W; 0.5 A Attention: Versions without protective earth conductor - operation only at safety extra-low voltage e.g. WIKA contact protection relay or external earthing Mounting position Vertical ± 30 Ingress protection IP 65 per EN 60 59 / lec 59 Page 9 of 14

Spherical floats (K) Ø C D E B D = Limit S. G. of the medium iersed float volume 85 % E = Nominal S. G. of the medium iersed float volume 50 % Ø A Material Suits guide tube Ø Ø A B Ø C Max. working pressure bar Max. operating temperature C Limit S. G. 85 % kg/m 3 Nominal S. G. 50 % kg/m 3 Stainless steel 1.4571 8 9 8 9 6 100 977 1660 8 9 8 9 5 100 1069 1817 1 5 5 15 40 300 769 1307 1 6 61 15 3 300 597 1015 1 83 81 15 5 300 408 693 18 80 76 3 5 300 679 1155 18 98 96 3 5 300 597 1016 18 105 103 3 5 300 533 907 18 10 117 3 5 300 389 661 Titanium 3.7035 8 9 8 9 30 100 8 1397 1 5 5 15 5 300 707 101 1 5 5 15 60 300 85 1448 1 5 5 15 80 300 1060 180 1 6 6 15 5 300 505 859 1 83 81 15 5 300 78 473 18 80 76 3 5 300 665 1130 18 98 96 3 5 300 495 841 18 105 103 3 5 300 369 67 18 10 117 3 5 300 39 560 Stainless steel 1.4571 1 53 53 14 5 depending on medium 745 166 E-CTFE coated 1 63 6 14 5 depending on medium 591 1005 1 84 8 14 5 depending on medium 403 685 18 81 77 5 depending on medium 718 10 18 99 97 5 depending on medium 675 1148 18 106 104 5 depending on medium 633 1076 18 11 118 5 depending on medium 459 781 Note: The optimum float will be selected after a feasibility test carried out by WIKA. Page 10 of 14

Cylindrical floats (Z) Ø C D E B D = Limit S. G. of the medium iersed float volume 85 % E = Nominal S. G. of the medium iersed float volume 50 % Ø A Material Suits guide tube Ø Ø A B Ø C Max. working pressure bar Max. operating temperature C Limit S. G. 85 % kg/m 3 Nominal S. G. 50 % kg/m 3 Stainless steel 1.4571 8 7 31 10 16 100 787 1338 1 44 5 15 16 300 818 1390 Titanium 3.7035 1 44 5 15 16 300 70 14 Buna 8 0 0 9 3 80 939 1597 8 3 5 9 3 80 80 1364 8 5 14 9 3 80 787 1337 8 30 45 13 3 80 683 1161 1 40 30 15 3 80 581 988 1 40 10 15 3 80 409 694 18 50 45 19 3 80 498 847 PVC 1 44 44 14 3 60 651 1107 16 55 54 3 60 798 1357 0 55 80 6 3 60 919 1563 16 55 70 3 60 674 1145 0 80 79 5 3 60 573 974 Polypropylene 8 7 9 9 3 80 755 184 8 35 33 9 3 80 675 1148 1 44 44 14 3 80 478 81 16 55 54 3 80 58 989 0 55 80 6 3 80 669 1137 0 80 79 5 3 80 431 73 PVDF 1 44 55 14 3 100 78 139 16 55 69 3 100 81 1396 0 55 80 6 3 100 1140 1938 0 80 79 5 3 100 681 1157 Stainless steel 1.4571 E-CTFE coated 1 45 53 14 16 depending on medium 78 139 Note: The optimum float will be selected after a feasibility test carried out by WIKA. Page 11 of 14

Contact protection measures To ensure reliable operation of sensors with reed switches and highest possible service life, we recoend using one of the following circuits. Inductive load AC S1 Surge current measurement with oscilloscope S1 C R E 4-30V AC R C RC modules depending on operating voltage see table Example: C = 0.33 µf/4 V DC 4 V DC R M Inductive load DC + 4-50V DC S1 Shunt diode e.g. 1N4007 I (A) 4 3 1 3-10 without current limitation with current limitation not allowed allowed Current limitation with capacitive load e.g. PLC, DCS and cables > 50 m Protective RC modules t (? µ s) + 4 V DC S1 R S C 1 SPS Rs = Ohm (47 Ohm with 0 VA contacts) C 1 = internal capacitance RC modules are, depending on the operating voltage, to be used exclusively according to the table below. D L D = Ø 16 - Ø 5 L = 6-58 Current limitation with electronic timers 00 wire + 30 V AC S1 R S C 1 time Zeitrelais relay Rs = 0 Ohm (30 V AC) C 1 = internal capacitance For inert gas contacts from 10... 40 VA Capacitance Resistance Voltage 0.33 µf 100 Ohm 4 V AC 0.33 µf 0 Ohm 48 V AC 0.33 µf 470 Ohm 115 V AC 0.33 µf 1500 Ohm 30 V AC For inert gas contacts from 40... 100 VA Capacitance Resistance Voltage 0.33 µf 47 Ohm 4 V AC 0.33 µf 100 Ohm 48 V AC 0.33 µf 470 Ohm 115 V AC 0.33 µf 1000 Ohm 30 V AC Other types than the RC modules specified here might lead to destruction of the reed contact. Page 1 of 14

Connection diagrams Colour coding per IEC 757 PVC cable Silicone cable Contact makes or breaks Change-over Contact makes or breaks Change-over Contact makes or breaks Change-over switch points 3 switch points 4 switch points L4 5 switch points VT L4 L5 switch points 3 switch points / 4 switch points / VT / L4 switch points 3 switch points switch points 1 switch points 1 3 4 3 switch points 1 3 4 5 6 4 switch points 1 3 4 5 6 7 L4 8 5 switch points 1 3 4 5 6 7 L4 8 VT 9 L5 CLEAR 10 1 3 switch points 1 3 4 5 6 3 switch points 1 OG 3 4 5 6 7 8 9 4 switch points 1 OG 3 4 5 6 7 8 9 10 VT 11 L4 CLEAR 1 6 switch points 6 switch points / / VT L4 L5 L6 1 3 4 5 6 7 8 VT 9 CLEAR 10 11 OG 1 L4 L5 L6 Page 13 of 14

Connection diagrams Colour coding per IEC 757 Coupler connector ASC4 Coupler connector M1 Contact makes or breaks Change-over 1 1 3 1 4 3 3 switch points 1 3 1 3 4 5 PE 1 4 Float switches with thermal contacts PVC or silicone cable or terminal box PVC cable Silicone cable or terminal box PVC or silicone cable or terminal box PVC cable 1 Thermal contact Thermal contacts Thermal contacts 1 Thermal contact Thermal contacts Thermal contacts 1 3 4 55 C 75 C 1 3 4 5 6 55 C 75 C 1 3 4 5 / 55 C 75 C 1 OG 3 4 5 6 7 55 C 75 C Coupler connector ASC4 Coupler connector M1 Coupler connector M1 1 Thermal contact 1 3 1 Thermal contact 1 3 4 1 Thermal contact 1 3 4 5 Ordering information Model / Version / Electrical connection / Process connection / Guide tube diameter / Guide tube length L / Information about contact (switch function, number of switch points, switch position) / Process details (operating temperature and pressure, Limit S. G.) / Options Modifications may take place and materials specified may be replaced by others without prior notice. Specifications and dimensions given in this leaflet represent the state of engineering at the time of printing. Page 14 of 14 WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. (+49) 937/13-0 Fax (+49) 937/13-406 E-mail info@wika.de www.wika.de 01/010 GB