AN IN-LINE POWER MONITOR FOR HE11 LOW LOSS TRANSMISSION LINES

Similar documents
PERFORMANCE OF THE 110 GHz SYSTEM ON THE DIII D TOKAMAK

THE 110 GHz MICROWAVE HEATING SYSTEM ON THE DIII D TOKAMAK

GA A26816 DESIGNS OF NEW COMPONENTS FOR ITER ECH&CD TRANSMISSION LINES

INFRARED MEASUREMENTS OF THE SYNTHETIC DIAMOND WINDOW OF A 110 GHz HIGH POWER GYROTRON

GA A24691 STATUS OF THE ELECTRON CYCLOTRON HEATING SYSTEM ON DIII D

INITIAL RESULTS FROM THE MULTI-MEGAWATT 110 GHz ECH SYSTEM FOR THE DIII D TOKAMAK

GA A22776 THE DESIGN AND PERFORMANCE OF WAVEGUIDE TRANSMISSION LINE COMPONENTS FOR PLASMA ELECTRON CYCLOTRON HEATING (ECH) SYSTEMS

GA A26150 PROGRESS ON DESIGN AND TESTING OF CORRUGATED WAVEGUIDE COMPONENTS SUITABLE FOR ITER ECH AND CD TRANSMISSION LINES

GA A22963 RECENT DEVELOPMENTS ON THE HIGH POWER ECH INSTALLATION AT THE DIII D TOKAMAK

HIGH-POWER CORRUGATED WAVEGUIDE COMPONENTS FOR mm-wave FUSION HEATING SYSTEMS

THE MEASURED PERFORMANCE OF A 170 GHz REMOTE STEERING LAUNCHER

GA A22897 QUASI-OPTIC COMPONENTS IN OVERSIZED CORRUGATED WAVEGUIDE FOR MILLIMETER-WAVE TRANSMISSION SYSTEMS

GA A22583 FAST WAVE ANTENNA ARRAY FEED CIRCUITS TOLERANT OF TIME-VARYING LOADING FOR DIII D

GA A22574 ADVANTAGES OF TRAVELING WAVE RESONANT ANTENNAS FOR FAST WAVE HEATING SYSTEMS

GA A25836 PRE-IONIZATION EXPERIMENTS IN THE DIII-D TOKAMAK USING X-MODE SECOND HARMONIC ELECTRON CYCLOTRON HEATING

PRACTICAL EXPERIENCES WITH THE 6 GYROTRON SYSTEM ON THE DIII D TOKAMAK

GA A25793 CW OPERATION OF CORRUGATED WAVEGUIDE TRANSMISSION LINES FOR ITER ECH AND CD SYSTEM

GA A22577 AN ELM-RESILIENT RF ARC DETECTION SYSTEM FOR DIII D BASED ON ELECTROMAGNETIC AND SOUND EMISSIONS FROM THE ARC

HIGH-POWER CORRUGATED WAVEGUIDE COMPONENTS FOR mm-wave FUSION HEATING SYSTEMS

A REGULATED POWER SUPPLY FOR THE FILAMENTS OF A HIGH POWER GYROTRON

GA A24030 ECE RADIOMETER UPGRADE ON THE DIII D TOKAMAK

Measurements of edge density profile modifications during IBW on TFTR

Testing of ITER-Class ECH Transmission Line Components at the JAEA Radio-Frequency Test Stand

FAST WAVE ANTENNA ARRAY FEED CIRCUITS TOLERANT OF TIMElVARYING LOADING FOR DIII-D

Study of Elliptical Polarization Requirement of KSTAR 84-GHz ECH System

GA A SOLID-STATE HIGH VOLTAGE MODULATOR WITH OUTPUT CONTROL UTILIZING SERIES-CONNECTED IGBTs by J.F. TOOKER and P. HUYNH

AN ELM=RESlLlENT RF ARC DETECTION SYSTEM FOR DIII-D BASED ON ELECTROMAGNETIC AND SOUND EMISSIONS FROM THE ARC

GA A27238 MEASUREMENT OF DEUTERIUM ION TOROIDAL ROTATION AND COMPARISON TO NEOCLASSICAL THEORY IN THE DIII-D TOKAMAK

GA A22712 DIII D ICRF HIGH VOLTAGE POWER SUPPLY REGULATOR UPGRADE

GA A25824 A NEW OVERCURRENT PROTECTION SYSTEM FOR THE DIII-D FIELD SHAPING COILS

INITIAL TESTS AND OPERATION OF A 110 GHz, 1 MW GYROTRON WITH EVACUATED WAVEGUIDE SYSTEM ON THE DIII D TOKAMAK

TESTS AND PERFORMANCE ON THE SIX GYROTRON SYSTEM ON THE DIII-D TOKAMAK

Estimation of the Loss in the ECH Transmission Lines for ITER

GA A23281 EXTENDING DIII D NEUTRAL BEAM MODULATED OPERATIONS WITH A CAMAC BASED TOTAL ON TIME INTERLOCK

Introduction to Radar Systems. The Radar Equation. MIT Lincoln Laboratory _P_1Y.ppt ODonnell

Radio Frequency Current Drive for Small Aspect Ratio Tori

GA A FABRICATION OF A 35 GHz WAVEGUIDE TWT CIRCUIT USING RAPID PROTOTYPE TECHNIQUES by J.P. ANDERSON, R. OUEDRAOGO, and D.

RF HIGH VOLTAGE PERFORMANCE OF RF TRANSMISSION LINE COMPONENTS ON THE DIII-D FAST WAVE CURRENT DRIVE (FWCD) SYSTEM

UCRL-ID Broad-Band Characterization of the Complex Permittivity and Permeability of Materials. Carlos A. Avalle

+o GENEML ATOMfCS. RF POWER DIAGNOSTICS AND CONTROL ON THE DIII-D, 4 MW MHz FAST WAVE CURRENT DRIVE SYSTEM (FWCD)

The ACT External HEPA Push-Through Filter Assembly. A. A. Frigo, S. G. Wiedmeyer, D. E. Preuss, E. F. Bielick, and R. F. Malecha

2. Achievement of reliable long pulse operation of 1 MW 170 GHz gyrotron

GA A23983 AN ADVANCED COLLABORATIVE ENVIRONMENT TO ENHANCE MAGNETIC FUSION RESEARCH

National Accelerator LaboratoryFERMILAB-TM-1966

Design study for JT-60SA ECRF system and the latest results of JT-60U ECRF system

Sandia National Laboratories MS 1153, PO 5800, Albuquerque, NM Phone: , Fax: ,

Detector And Front-End Electronics Of A Fissile Mass Flow Monitoring System

CT-7Ra Development of Gyrotron and JT-60U EC Heating System for Fusion Reactor

ENLARGEMENT OF GLASS AND PLASTIC SHELLS TO 2 mm IN DIAMETER BY REDROPPING THROUGH A SHORT HEATED TOWER

Measurements of MeV Photon Flashes in Petawatt Laser Experiments

MAPPING INDUCED POLARIZATION WITH NATURAL ELECTROMAGNETIC FIELDS FOR EXPLORATION AND RESOURCES CHARACTERIZATION BY THE MINING INDUSTRY

National Accelerator Laboratory

Introduction to Radar Systems. Radar Antennas. MIT Lincoln Laboratory. Radar Antennas - 1 PRH 6/18/02

GYROTRON-BASED MILLIMETER-WAVE: BEAMS FOR MATERIAL PROCESSING. Thomas Hardek Wayne Cooke. William P e r r y D a n i e l Rees

Nanosecond, pulsed, frequency-modulated optical parametric oscillator

Hardware-in-the-Loop Testing of Wireless Systems in Realistic Environments

J.Shafii, J.N. Talmadge, R.J. Vernon, HSX team HSX Plasma Laboratory, University of Wisconsin-Madison T. S. Bigelow, ORNL K.M.

Development of the 170GHz gyrotron and equatorial launcher for ITER

Five-beam Fabry-Perot velocimeter

MONITORING POWER PLANT EFFICIENCY USING THE MICROWAVE-EXCITED PHOTOACOUSTIC EFFECT TO MEASURE UNBURNED CARBON. Quarterly Technical Progress Report

MAPPING INDUCED POLARIZATION WITH NATURAL ELECTROMAGNETIC FIELDS FOR EXPLORATION AND RESOURCES CHARACTERIZATION BY THE MINING INDUSTRY

High Explosive Radio Telemetry System. Federal Manufacturing & Technologies. R. Johnson, FM&T; B. Mclaughlin, FM&T;

Detection of Targets in Noise and Pulse Compression Techniques

' Institut fuer Kernphysik, Strahlenzentrum, JLU Giessen, Germany 3

Armlication For United States Patent For HOT CELL SHIELD PLUG EXTRACTION APPARATUS. Philip A. Knapp Moore, ID. and. Larry K. Manhart Pingree, ID

GA A24463 CONTROL SYSTEM FOR THE LITHIUM BEAM EDGE PLASMA CURRENT DENSITY DIAGNOSTIC ON THE DIII D TOKAMAK

Up-conversion Time Microscope Demonstrates 103x Magnification of an Ultrafast Waveforms with 300 fs Resolution. C. V. Bennett B. H.

GA A25780 STABILIZATION OF NEOCLASSICAL TEARING MODES IN TOKAMAKS BY RADIO FREQUENCY CURRENT DRIVE

Increased Stable Beta in DIII D by Suppression of a Neoclassical Tearing Mode Using Electron Cyclotron Current Drive and Active Feedback

Final. NO.Report CRADA. Date: September 11, 1997

Reducing space charge tune shift with a barrier cavity

SOL Reflectometer for Alcator C-Mod

Accelerator and Fusion Research Division Lawrence Berkeley Laboratory University of California Berkeley, CA 94720

National Accelerator Laboratory

Diagnostic development to measure parallel wavenumber of lower hybrid waves on Alcator C-Mod

Active Control for Stabilization of Neoclassical Tearing Modes

1997 Particle Accelerator Conference, Vancouver, B.C., Canada, May 12-16, 1997 BNL

Test Results of the HTADC12 12 Bit Analog to Digital Converter at 250 O C

DEVELOPMENT OF THE PULSE TRANSFORMER FOR NLC KLYSTRON PULSE MODULATOR* Abstract

Stimulated Emission from Semiconductor Microcavities

U.S. DEPARTMENT OF ENERGY. YlAMT-485 Y-I 2. Project Accomplishment Summary for Project Number 92-Y12P-013-B2 HYDROFORMING DESIGN AND PROCESS ADVISOR

k SLAC-PUB-7583 July 1997 Co/vF PULSE TRANSFORMER R&D FOR NLC KLYSTRON PULSE MODULATOR*

P. Koert, P. MacGibbon, R. Vieira, D. Terry, R.Leccacorvi, J. Doody, W. Beck. October 2008

High-]FrequencyElectric Field Measurement Using a Toroidal Antenna

&wf-9+/ob/--21*~~ II. Ron Harper and Robert A. Hike

SUMMARY OF THE EXPERIMENTAL SESSION EC-10 WORKSHOP

Fundamental Mode RF Power Dissipated in a Waveguide Attached to an Accelerating Cavity. Y. W. Kang

Los Alamos. Low-Field Magnetic Resonance Imaging of. David M. Schmidt, Michelle A. Espy, P-21

RECENT UPGRADES AND EXTENSIONS OF THE ASDEX UPGRADE ECRH SYSTEM

Implementation of an Acoustic Emission Proximity Detector for Use in Generating Glass Optics. M. A. Piscotty, J. S. Taylor, K. L.

Positron Beam Position Measurement for a Beam Containing Both Positrons and Electrons *

Performance of Image Intensifiers in Radiographic Systems

Introduction to Radar Systems. Clutter Rejection. MTI and Pulse Doppler Processing. MIT Lincoln Laboratory. Radar Course_1.ppt ODonnell

STP-NU ROADMAP TO DEVELOP ASME CODE RULES FOR THE CONSTRUCTION OF HIGH TEMPERATURE GAS COOLED REACTORS (HTGRS)

Recent advances in ALAMO

D. F. Spencer R. Aryaeinejad E. L. Reber. October 2001

Report on Ghosting in LL94 RAR Data

Evaluation of Roof Bolting Requirements Based on In-Mine Roof Bolter Drilling

High Speed Infrared Emitting Diode, 850 nm, GaAlAs Double Hetero

GA A22869 BOUNCE COATING INDUCED DOMES ON GLOW DISCHARGE POLYMER COATED SHELLS

Transcription:

GA A24757 AN IN-LINE POWER MONITOR FOR HE11 LOW LOSS TRANSMISSION LINES by R.W. CALLIS, J. LOHR, I.A. GORELOV, K. KAJIWARA, D. PONCE, J.L. DOANE, J.F. TOOKER JUNE 2004 QTYUIOP

DISCLAIMER This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise, does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof.

AN IN-LINE POWER MONITOR FOR HE11 LOW LOSS TRANSMISSION LINES GA A24757 by R.W. CALLIS, J. LOHR, I.A. GORELOV, K. KAJIWARA,* D. PONCE, J.L. DOANE, J.F. TOOKER This is a preprint of a paper to be presented at the Joint 29th International Conference on Infrared and Millimeter Waves and 12th International Conference on Terahertz Electronics, Karlsruhe, Germany, September 27 October 1, 2004 and to be published in the Proceedings. *Oak Ridge Institute for Science Education, Oak Ridge, Tennessee Work supported by the U.S. Department of Energy under Contract DE-FC02-04ER54698 and Grant DE-AC05-76OR00033 GENERAL ATOMICS PROJECT 30200 JUNE 2004 QTYUIOP

ABSTRACT A power monitor has been developed for the DIII D 110 GHz EC transmission line, which allows for the measurement of power flowing in the transmission line before it reaches the launcher. The power monitor uses a small break in the transmission line to radiate power, which is then measured. INTRODUCTION High-power millimeter waves are used in fusion research to locally probe, heat, and drive current in thermonuclear plasmas. For most applications, the fusion researcher needs to have a reasonable estimate of the power delivered to the plasma in order to develop scaling laws, especially to identify the critical power density, that may trigger a transition-of-state within the plasma [1]. The simplest method of measuring the power is to divert a small quantity of power through small sampling holes milled into one of the miter bends used in the transmission line, rectifying the intercepted power and produces a signal proportional to power [2]. Nominally, the first miter bend located downstream from the gyrotron is used for this purpose. However, there are two serious problems with this process. First, the power coupled through the holes is extremely sensitive to both polarization and mode content. Second, the first miter bend is sometimes 100 m from the launcher with ten or more bends randomly placed throughout the transmission line, with each bend producing a limited but unknown quantity of mode conversion that may or may not propagate to the launcher. In other words, there is no simple relationship between the power signal measured at the first miter bend and the power launched into the plasma. Placing a power monitor at the last miter bend before the launcher results in a more accurate measurement but suffers from the polarization hyper-sensitivity found in this type of power monitor. And since the polarization can be changed from experiment to experiment, there would still be no consistent relationship between the signal measured and the power launched into the plasma. With this in mind, the DIII D EC program has developed an in-line power monitor that can be placed arbitrarily close to the launcher. (It is not limited to the location of the last miter bend, which could be six or more meters from the launcher.) IN-LINE POWER MONITOR Rather than use a series of holes in a mirror to produce a pick-off signal, the in-line power monitor uses the condition that when the HE 11 mode travels through a corrugated waveguide the wall currents are low to nonexistent and thus can tolerate a break in the transmission line. Even if the gap is larger than several wavelengths, the power leak is relatively low. By surrounding the gap with a stainless steel cylinder, the rf leakage is effectively trapped while the vacuum envelope of the waveguide is maintained. A narrow ring of TiO 2 is applied to the inside of the General Atomics Report GA A24757 1

stainless cylinder, which successfully absorbs the rf leaking out of the gap. Four resistive thermal detectors (RTDs) are placed around the outside of the stainless steel cylinder over the TiO 2 absorption zone, and a fifth RTD is placed at the end of the cylinder to act as a background monitor. The radiated signal fraction is given by F = 0.55(λG/D 2 ) 3/2, where G is the waveguide gap length, D is the waveguide diameter, and λ is the free space wavelength. For G = 2.5 mm and D = 31.75 mm, F = 0.03%, or 300 W for 1 MW transmitted rf power. Figure 1 shows the configuration of the in-line power monitor developed for DIII D. A waveguide gap radiates ~300 W when 1 MW is transmitted Lossy TiO 2 on inside of stainless steel tube absorbs radiation from the gap 113.3 51 51 31.75 102 2.5 505 An RTD on outside of stainless steel tube indicates the total absorbed energy 1.65 An RTD on end flange compensates for ambient temperature variations and for multiple-pulse temperature ratcheting Fig. 1. Cross-sectional view of the in-line power monitor developed for the DIII D EC system. The thermal transit time from the TiO 2 band through the stainless steel cylinder is less than 1 s, whereas the transit time through the stainless to the end flanges is 730 s. Thus, the simple measurement of the temperature over the band minus the base line temperature should give a signal linearly proportional to the power throughput. Figure 2 illustrates a typical differential temperature measurement from one of the RTD signals for a 1 s pulse at a power level of 550 kw. Note the strong signal-to-noise level and the fast rise in temperature during the pulse. In order to validate and calibrate the in-line power monitor, a long line of waveguide was set up in the gyrotron vault at DIII D. The length of the line was similar to the ~80 m used between the gyrotrons and the DIII D tokamak and contained 15 miter bends similar to that used in the most extreme DIII D EC transmission line. Two of the miter bends house polarizers so that the polarity of the rf power passing through the in-line power monitor could be swept over a range of 0 to 90 deg. The test transmission line was terminated into a dummy load from which total injected power could be measured. By measuring the temperature response of four RTDs placed equally around the outside of the stainless steel cylinder (every 90 deg), it was found that there was a nonuniform heating of the cylinder and that the nonuniformity changed as the polarization changed. Figure 3 shows the results of the measurements of the four RTDs (after the background is subtracted) as the polarization is rotated from 0 to 90 deg in 10-deg steps. Also included is a line representing the General Atomics Report GA A24757 2

average of the four RTDs for each polarity (signified as SUM/4 on the figure) and a straight line representing the average temperature rise of all 40 measurements (line labeled AVE). 10 8 T (K) 6 4 2 0 10 40 90 140 190 240 290 340 Time (s) Fig. 2. Typical t response for one of the RTDs on the in-line power monitor for a 1 s pulse at a power level of 550 kw. 20 15 T (K) 10 5 0 0 RTD1 RTD2 RTD3 RTD4 SUM/4 AVE 10 20 30 40 50 60 70 80 90 Polarizer Angle (deg) Fig. 3. Rise in temperature measured on the four RTDs mounted on the outside of the in-line power monitor, for 1 s pulses at 550 kw as the polarization is rotated over 90 deg. Also shown is the average for each polarization, SUM/4, and the average of all 40 measurements, AVE. It is obvious that no single RTD can be used to represent the power level of the rf passing through the power monitor. There could be an error as large as 25% if the polarity is unfavorable. Even the sum of all four signals has a 10% variation as the polarization is varied. Because not all miter bends have their mirror located in the same plane it was expected there would be some variation in the polarization sweep. This is the result of rf wave with a less desirable orientation (resulting in higher losses and mode conversion) on some miter bends and more favorable on others. Consequently, the ratio would change as the polarization was swept. However, it was General Atomics Report GA A24757 3

believed that this would be a 5% effect at most. To achieve reasonable accuracy, each power monitor will be calibrated in situ. And since the polarization sweep anticipated is on the order of 13 deg, the error bars on the signal should be small. SUMMARY The DIII D EC program has developed an in-line power monitor based on the concept that a small but consistent amount of rf power will leak out of a gap in a corrugated waveguide transmission line carrying the HE 11 mode. The magnitude of the power can be measured by detecting the temperature rise of a band of TiO 2 located over the gap. The design of the power monitor is such that for short pulses (<20 s) the increase in temperature is linear with power and pulse length, which makes it ideal for the DIII D program. However, the power monitor was found to be more sensitive to polarization rotation than expected. As a result, each power monitor will have to be calibrated in situ and limited to the small range of polarization (±6 deg) used for DIII D experiments. ACKNOWLEDGMENT Work Supported by the U.S. Department of Energy under Contract DE-FC02-04ER54698 and Grant DE-AC05-76OR00033. [1] R. Prater, Phys. Plasmas, vol. 11, 2004, 2349. REFERENCES [2] John Lohr, et al., The Electron Cyclotron Resonant Heating System on the DIII D Tokamak, to be published in Fusion Sci. and Technol., 2004. General Atomics Report GA A24757 4