Indicator of Small Calcification Detection in Ultrasonography using Decorrelation of Forward Scattered Waves

Similar documents
High Range Resolution Ultrasonographic Vascular Imaging Using Frequency Domain Interferometry With the Capon Method

Introduction. Parametric Imaging. The Ultrasound Research Interface: A New Tool for Biomedical Investigations

MULTI-FREQUENCY ULTRASOUND IMAGING: PHANTOM STUDY

Optimization of Axial Resolution in Ultrasound Elastography

Parameter Estimation Techniques for Ultrasound Phase Reconstruction. Fatemeh Vakhshiteh Sept. 16, 2010

A miniature all-optical photoacoustic imaging probe

ACCURACY IMPROVEMENT ON NON-INVASIVE ULTRASONIC-DOPPLER FLOW MEASUREMENT BY UTILZING SHEAR WAVES IN METAL PIPE

Digital Quality Control Phantom for X-ray Mammography Image

Improved Tomosynthesis Reconstruction using Super-resolution and Iterative Techniques

Resolution Enhancement and Frequency Compounding Techniques in Ultrasound.

Experimental Study on Super-resolution Techniques for High-speed UWB Radar Imaging of Human Bodies

Optical coherence tomography

Ihor TROTS, Andrzej NOWICKI, Marcin LEWANDOWSKI

Exact Simultaneous Iterative Reconstruction Technique Algorithm-An Effective Tool In Biomedical Imaging

ULTRASONIC DEFECT DETECTION IN BILLET USING TIME- OF-FLIGHT OF BOTTOM ECHO

Super-Resolution UWB Radar Imaging Algorithm Based on Extended Capon with Reference Signal Optimization

Breast Ultrasound QA Phantom Recommended by Japan Association of Breast and Thyroid Sonology

SIGNAL PROCESSING FOR ADVANCED CORRELATION ULTRASONIC VELOCITY PROFILER

Testing a wavelet based noise reduction method using computersimulated

A Study On Preprocessing A Mammogram Image Using Adaptive Median Filter

BEAM DISTORTION IN DOPPLER ULTRASOUND FLOW TEST RIGS: MEASUREMENT USING A STRING PHANTOM

Ultrasound Physics. History: Ultrasound 2/13/2019. Ultrasound

Introduction, Review of Signals & Systems, Image Quality Metrics

THE PROBLEM of electromagnetic interference between

A Novel Transform for Ultra-Wideband Multi-Static Imaging Radar

Ultrasound Beamforming and Image Formation. Jeremy J. Dahl

Observer Performance of Reduced X-Ray Images on Liquid Crystal Displays

Fig. 1

Ultrasonic Linear Array Medical Imaging System

Bayesian Estimation of Tumours in Breasts Using Microwave Imaging

Lecture 25 Optical Coherence Tomography

ULTRASONIC IMAGING of COPPER MATERIAL USING HARMONIC COMPONENTS

Multi-spectral acoustical imaging

Medical Imaging. X-rays, CT/CAT scans, Ultrasound, Magnetic Resonance Imaging

ULTRASONIC GUIDED WAVE ANNULAR ARRAY TRANSDUCERS FOR STRUCTURAL HEALTH MONITORING

Acoustic resolution. photoacoustic Doppler velocimetry. in blood-mimicking fluids. Supplementary Information

Virtual monochromatic imaging in dual-source and dual-energy CT for visualization of acute ischemic stroke

Real Time Deconvolution of In-Vivo Ultrasound Images

PERFORMANCE MEASUREMENT OF MEDICAL IMAGING SYSTEMS BASED ON MUTUAL INFORMATION METRIC

Interaction of Sound and. logarithms. Logarithms continued. Decibels (db) Decibels (db) continued. Interaction of Sound and Media continued

Transmission- and side-detection configurations in ultrasound-modulated optical tomography of thick biological tissues

SECTION I - CHAPTER 2 DIGITAL IMAGING PROCESSING CONCEPTS

Noise-robust compressed sensing method for superresolution

Introduction. MIA1 5/14/03 4:37 PM Page 1

X-ray phase-contrast imaging

Acousto-optic imaging of tissue. Steve Morgan

Predicted image quality of a CMOS APS X-ray detector across a range of mammographic beam qualities

Ultrawideband (UWB) pulse radar with high range resolution

Analysis of spatial dependence of acoustic noise transfer function in magnetic resonance imaging

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

Global Journal of Engineering Science and Research Management

Original Contribution

Session: 2A NEW ULTRASOUND SYSTEMS Chair: H. Ermert University of Bochum 2A-1 10:30 a.m.

DESIGN OF SLOTTED RECTANGULAR PATCH ARRAY ANTENNA FOR BIOMEDICAL APPLICATIONS

High-range-resolution imaging using frequency domain interferometry with stabilization techniques for real-time vascular ultrasound

Mammography Solution. AMULET Innovality. The new leader in the AMULET series. Tomosynthesis, 3D mammography and biopsy are all available.

Tactile Sensation Imaging for Artificial Palpation

A pre-processing technique to improve the performance of a computer-aided detection scheme in mammography

Proceedings of Meetings on Acoustics

Image Enhancement in Spatial Domain

15 th Asia Pacific Conference for Non-Destructive Testing (APCNDT2017), Singapore.

Microwave Imaging of Biological Tissues: the current status in the research area

VHF Radar Target Detection in the Presence of Clutter *

TRIANGULATION-BASED light projection is a typical

Differentiation of Malignant and Benign Masses on Mammograms Using Radial Local Ternary Pattern

Imaging Technique Optimization of Tungsten Anode FFDM System

Advanced Ultrasonic Imaging for Automotive Spot Weld Quality Testing

HIGH RESOLUTION COMPUTERIZED TOMOGRAPHY SYSTEM USING AN IMAGING PLATE

12/26/2017. Alberto Ardon M.D.

CHAPTER 4 - BREAST CANCER STAGE DETECTION (BCSD) USING MULTI VIEW UNIVARIATE CLASSIFICATION

Non Invasive Electromagnetic Quality Control System

HISTORY. CT Physics with an Emphasis on Application in Thoracic and Cardiac Imaging SUNDAY. Shawn D. Teague, MD

Lesson 06: Pulse-echo Imaging and Display Modes. This lesson contains 22 slides plus 15 multiple-choice questions.

CHAPTER 1 INTRODUCTION

Ultrasound physical principles in today s technology

M5 Diagnostic Ultrasound System

Transmission of Ultrasonic Waves Via Optical Silica Glass Fiber Doped by 7.5% of TiO 2 with the Use of Power Sandwich Transducer

Microwave-induced acoustic imaging of biological tissues

Applications of a Pixellated Detection System to Digital Mammography

Attenuation and velocity of ultrasound in solid state materials (transmission)

Takuya Sakamoto Tel/Fax:

30 lesions. 30 lesions. false positive fraction

The physics of ultrasound. Dr Graeme Taylor Guy s & St Thomas NHS Trust

Diffraction-enhanced X-ray Imaging (DEXI) Medical Solutions. More information using less radiation

Non-Contact Ultrasound Characterization of Paper Substrates

Evaluation of a Chip LED Sensor Module at 770 nm for Fat Thickness Measurement of Optical Tissue Phantoms and Human Body Tissue

Sensors. CSE 666 Lecture Slides SUNY at Buffalo

COMPUTER-AIDED DETECTION OF CLUSTERED CALCIFICATION USING IMAGE MORPHOLOGY

Breast Tomosynthesis. Bob Liu, Ph.D. Department of Radiology Massachusetts General Hospital And Harvard Medical School

Image Quality/Artifacts Frequency (MHz)

EXPLORING POTENTIAL MECHANISMS RESPONSIBLE FOR OBSERVED CHANGES OF ULTRASONIC BACKSCATTERED ENERGY WITH TEMPERATURE VARIATIONS XIN LI THESIS

AN APPROXIMATION-WEIGHTED DETAIL CONTRAST ENHANCEMENT FILTER FOR LESION DETECTION ON MAMMOGRAMS

New spectral benefi ts, proven low dose

Development of an innovative LSO-SiPM detector module for high-performance Positron Emission Tomography

An Overview Algorithm to Minimise Side Lobes for 2D Circular Phased Array

Online Gauging As We Know It! by Udo Skarke Erhardt-Leimer Inc.

OPTIMAL POINT TARGET DETECTION USING DIGITAL RADARS

Ultrasound-modulated optical tomography of absorbing objects buried in dense tissue-simulating turbid media

EMBEDDED FBG SENSORS AND AWG-BASED WAVELENGTH INTERROGATOR FOR HEALTH MONITORING OF COMPOSITE MATERIALS

Photoacoustic imaging with coherent light

Transcription:

International Journal of Chemical and Biological Engineering 3:4 010 Indicator of Small Calcification Detection in Ultrasonography using Decorrelation of Forward Scattered Waves Hirofumi Taki, Takuya Sakamoto, Makoto Yamakawa, Tsuyoshi Shiina, and Toru Sato Abstract For the improvement of the ability in detecting small calcifications using Ultrasonography (US) we propose a novel indicator of calcifications in an ultrasound B-mode image without decrease in frame rate. Since the waveform of an ultrasound pulse changes at a calcification position, the decorrelation of adjacent scan lines occurs behind a calcification. Therefore, we employ the decorrelation of adjacent scan lines as an indicator of a calcification. The proposed indicator depicted wires 0.05 mm in diameter at cm depth with a sensitivity of 86.7% and a specificity of 100%, which were hardly detected in ultrasound B-mode images. This study shows the potential of the proposed indicator to approximate the detectable calcification sie using an US device to that of an X-ray imager, implying the possibility that an US device will become a convenient, safe, and principal clinical tool for the screening of breast cancer. Keywords Ultrasonography, Calcification, Decorrelation, Forward scattered wave I. INTRODUCTION LTRASONOGRAPHY (US) is a convenient and safe Uimaging tool with an excellent ability in depicting soft tissues; however, the ability of US in detecting a calcification is insufficient compared with X-ray computed tomography (CT) and other X-ray imaging techniques. For the evaluation of genitourinary calcifications, X-ray computed tomography (CT) has become the primary imaging modality, causing US to play a secondary role [1]. In general, US has difficulty detecting small calcifications 3.0 mm or less in sie []. US is also used as an adjunct to mammography in the diagnosis of breast cancer [3] [6]. The purpose of this study is to propose a useful indicator to detect small calcifications using US devices. The waveform of the echo behind a small calcification, being accompanied no acoustic shadowing, is supposed to be changed by the forward scattered wave originating at the calcification. In a recent study, H. Taki, T. Sakamoto, and T. Sato are with the Graduate School of Informatics, Department of Communications and Computer Engineering, Kyoto University, Kyoto, Japan (e-mail: hirofumi.taki@mb6.seikyou.ne.jp). M. Yamakawa is with the Advanced Biomedical Engineering Research Unit, Kyoto University, Kyoto, Japan. T. Shiina is with the Graduate School of Medicine, Kyoto University, Kyoto, Japan. we reported that the waveform change of the echo caused by a calcification results in the decorrelation between the echoes received at adjacent scan lines [7], [8]. These reports indicate that the existence of a small calcification is predictable from the waveform difference between adjacent scan lines by calculating cross-correlation coefficients. In this paper, we propose a novel indicator of calcifications and evaluate the method experimentally using a commercial US device. II. MATERIALS AND METHODS To detect calcifications, we utilie the decrease of cross-correlation coefficients between adjacent scan lines. Since the decrease of cross-correlation coefficients correspond to the phase change of the echo caused by a calcification, the proposed method is supposed to have higher sensitivity for the depiction of a calcification than acoustic shadowing, corresponding to the intensity change caused by a calcification. When a calcification exists in scan line, the waveform of an ultrasound pulse changes considerably at the calcification position in both transmit and receive paths, as shown in Fig. 1. Therefore the echo waveform of a scan line with a calcification is significantly different from that without a calcification, where the echoes return from the calcification or a range behind it. This indicates that a decrease in cross-correlation coefficients can predict the existence of a calcification. When a small calcification exists close to a layered structure, e.g. a calcification in a mammary duct and that on a gallbladder wall, the high-intensity specular echo from the layered structure severely interferes with the depiction of the calcification in a B-mode image. In this paper we thus investigate the performance of the proposed method when a layered structure exists just behind a calcification, one of the most difficult cases to detect a small calcification in a B-mode image. This section explains the detailed process of the proposed method. A. Real Data Oversampling Medical acoustic imagers utilie quadrature detectors to acquire IQ data. The detection is equivalent to the multiplication processes between a received signal and two sinusoidal waves, where the phase difference of the two sinusoidal waves is 90 degrees and their center frequency is equal to transmit center frequency. However the IQ data 175

International Journal of Chemical and Biological Engineering 3:4 010 correspond with the real and imaginary components of the received signal only at the transmit center frequency. When a broad-band signal is employed the so-called IQ data are really the oversampled real data with the sampling frequency of four times the transmit center frequency [9]. For the broad-band signal processing we convert the IQ data to the oversampled real data. m ) = ( 1) gi (, (1) m = ( 1) gq (, () = m, (3) where x and are the lateral and vertical components, respectively, of a measurement point on a B-mode image, is the oversampled real datum at P(, a pixel in a B-mode image, is the range interval, g I ( and g Q ( are respectively the IQ data at P(, and m is an integer. When the correlation of adjacent scan lines becomes the maximum value in the case that the correlation windows of the two scan lines are located at the same position, the cross-correlation between adjacent scan lines of oversampled real data is r( (4) = { ), ) +, }, where is the scan line interval. In this case the cross-correlation between adjacent scan lines of IQ data is expressed by Fig. 1 Waveform change of an ultrasound pulse originating from a calcification, causing the decrease of correlation between adjacent scan lines. r c ( = r( + j { ), +, )}. The error of the cross-correlation caused by the utiliation of IQ data increases when the correlation is calculated by a pair of scan lines with low correlation. This indicates the validity of the utiliation of the real data oversampling for the calculation of cross-correlation. B. Cross-correlation between Adjacent Scan Lines The proposed indicator of a calcification utilies the decorrelation of adjacent scan lines; however, a correlation coefficient is suppressed by not only a calcification, but also noise. When signals cut out by correlation windows have low signal-to-noise ratio (SNR), the effect of noise on the correlation coefficients is emphasied, interfering with the detection of the decrease on correlation coefficients caused by a calcification. In this study, we employ an echo intensity threshold and a modified Wiener filter to decrease the influence of noise on cross-correlation coefficients. An echo intensity threshold eliminates the signal with low SNR, and a cross-correlation coefficient with a modified Wiener filter suppresses the influence of noise on the cross-correlation coefficient. The proposed method calculates a cross-correlation r W when both the adjacent signals cut out by correlation windows are over an intensity threshold I t. lt = αni 0, (6) rw ( (7) '), ' + ls) + βni0 ' = 1 = max, l '), ' + ls) + βni 0 ' = 1 ' = 1 where α and β are positive numbers, n is the sie of correlation window width, I 0 is the average pixel intensity in a region of interest (ROI), S is the scan interval of a correlation window, 1 and are the minimum and maximum of the coordinates of a correlation window behind P(. In this study the correlation window width was 5 mm and 1 =. We examined the performance of the proposed indicator employing the nine combinations of parameters α and β, where α = 0, -3, and -6 db and β = 0, -10, and -0 db. C. Indicator of Calcifications Using Decorrelation between Scan Lines A region with significantly lower cross-correlation compared with common tissues indicates that a calcification exists in front of the region. To examine cross-correlation coefficients of common tissues except calcifications, we calculate the average μ and the standard deviation σ of the top 90% of the correlation coefficients in a ROI. The proposed indicator depicts the regions with lower correlation coefficients than μ γσ, where γ is a positive number. In this study we examined the cases of γ = 10, 7.5, and 5, where a larger value of (5) 176

International Journal of Chemical and Biological Engineering 3:4 010 γ means a severer correlation threshold. The proposed indicator calculates a correlation profile from a single B-mode image. This indicates that the proposed method involves no decrease in frame rate when a sufficient signal processing unit is employed. D. Experimental Setup Experiments were conducted using a Hitachi EUB-8500 (Hitachi, Tokyo, Japan) US device with a 7.5 MH linear array probe whose scan line interval is approximately 0.13 mm. We prepared nine calcification phantoms with three different copper wires (0., 0.1 and 0.05 mm in diameter) embedded into a 4% agar gel block. Fig. shows a B-mode image of the calcification phantom with wires 0.05 mm in diameter. Four wires of the same diameter were embedded into each phantom at 1 cm depth and 1 cm intervals, and three phantoms are prepared for each kind of phantom. A polyethylene sheet 0.1 mm thick was positioned just behind the wires. The agar gel contained 1% Tech Polymer particles, spherical polymer particles 7 μm in diameter (Sekisui Plastics Co., LTD.). We simulated in vivo conditions by placing a cutaneous tissue layer taken from a swine 1 cm thick onto the gel block. As a result, wires were positioned at cm depth. The sie of a ROI was 1 x 3.5 cm, and each ROI was marked with two stainless needles 0.4 mm in diameter located at the both side of the ROI. The center of a ROI is located at 1.75 cm depth, i.e. the median of the correlation window used for the calculation of the correlation at the center of a ROI is located at cm depth. In this study five B-mode images were obtained for each phantom. Therefore the performance of the proposed method for each kind of wire was investigated using a total of sixty wires in fifteen B-mode images. Fig. B-mode image of a calcification phantom with four wires 0.05 mm in diameter. White arrows point at wires, and a white broken line is the boundary of the ROI. Two needles 0.4 mm in diameter were set at both sides of the ROI. III. RESULTS Fig. 3 shows the cross-correlation profiles of three ROIs with the wires 0., 0.1, and 0.05 mm in diameter, where the intensity threshold parameter α and the stability parameter β are -3 and -10 db, respectively. The low correlation regions appear at the wire positions and extend along the range direction. The range ambiguity of the proposed indicator is caused by the width of the correlation window. These results imply that the correlation profile is a useful indicator of calcifications with higher sensitivity than acoustic shadowing. For the investigation of the efficiency of the proposed indicator we examined the sensitivity and the positive predictive value of a calcification detection method using the indicator. Each datum is presented as the average ± the standard deviation, where the sample sie is 15. The correlations between scan lines behind a calcification are suppressed continuously along the range direction. Thus the calcification detection method predicts the existence of a calcification when the low correlation region continues more than 0.5 times of the correlation window width along the range direction. Fig. 4 shows the distributions of the sensitivities and the positive predictive values of the calcification detection methods using nine combinations of parameters α and β, where Fig. 3 Normalied cross-correlation profiles of three ROIs with four wires (a) 0., (b) 0.1, and (c) 0.05 mm in diameter. The sie of each ROI is 1 x 3.5 cm. μ and σ are the average and the standard deviation of the top 90% of the correlation coefficients in each ROI. the correlation threshold parameter γ are 10, 7.5, and 5. The severe correlation threshold eliminates false images at the cost of the sensitivity of the method. When the correlation threshold parameter γ of 7.5 was employed, no false image appeared in the nine cases using different combinations of parameters α and β. In addition, the sensitivity of the method for a thin wire largely depends on the parameters α and β. For the solution of the two subjects, the optimiation of the parameters α and β and the improvement of the sensitivity of the proposed method, we propose a calcification detection method with a totaliing process. First, the method varies the combination of parameters α and β, where α = 0, -3, and -6 db and β = 0, -10, and -0 db. Then the method totals up all the low correlation regions appear in the nine cases of the combinations of parameters α and β. 177

International Journal of Chemical and Biological Engineering 3:4 010 Fig. 5 The sensitivity and the positive predictive value of the calcification detection method with a totaliing process. The method predicts the existence of calcifications using the totalied low correlation regions. Fig. 5 shows the sensitivities and the positive predictive values of the calcification detection method with the totaliing process. When the correlation threshold parameter γ of 7.5 was employed, the proposed calcification detection method with the totaliing process has excellent performance in detecting wires 0.05 mm in diameter with a sensitivity of 86.7 ± 15.5% and a positive predictive value of 100 ± 0%. When γ of 5 was employed the sensitivity of the proposed method was improved to 95.0 ± 10.0% at the cost of the decrease of a positive predictive value to 88.0 ± 13.6%. These results suggest the high potential of a calcification detection method employing the proposed indicator in small calcification detection. IV. CONCLUSION In this study we propose a novel indicator of a calcification using US without decrease in frame rate. A calcification detection method employing the proposed indicator detected wires 0.05 mm in diameter with a sensitivity of 86.7% and a positive predictive value of 100%. This study implies that the proposed indicator has the potential to approximate the performance of US in calcification detection to that of an X-ray imager, resulting that an US device will become a convenient, safe, and principal clinical tool for the screening of breast cancer. Fig. 4 Distributions of the sensitivities and the positive predictive values of the calcification detection methods using nine combinations of an intensity threshold parameter and a stability constant parameter. The diameters of wires are (a) 0., (b) 0.1, and (c) 0.05 mm. Three correlation thresholds μ 10σ, μ 7.5σ, and μ 5σ are examined. ACKNOWLEDGMENT This work is partly supported by the Research and Development Committee Program of the Japan Society of Ultrasonics in Medicine and the Innovative Techno-Hub for Integrated Medical Bio-imaging Project of the Special Coordination Funds for Promoting Science and Technology, from the Ministry of Education, Culture, Sports, Science and Technology (MEXT), Japan. 178

International Journal of Chemical and Biological Engineering 3:4 010 REFERENCES [1] H. Ödemir, M. K. Demir, O. Temiö, H. Genchellac, and E. Unlu, Phase inversion harmonic imaging improves assessment of renal calculi: a comparison with fundamental gray-scale sonography, J. Clin. Ultrasound., vol. 36, pp. 16-19, 008. [] K. A. B. Fowler, J. A. Locken, J. H. Duchesne, and M. R. Williamson, US for detecting renal calculi with nonenhanced CT as a reference standard, Radiology. vol., pp. 109-113, 00. [3] P. M. Lamb, N. M. Perry, S. J. Vinnicombe, and C. A. Wells, Correlation between ultrasound characteristics, mammographic findings and histological grade in patients with invasive ductal carcinoma of the breast, Clin. Radiol. vol. 55, pp. 40-44, 000. [4] D. Jacob et al., Analysis of the results of 137 subclinical breast lesions excisions. Value of ultrasonography in the early diagnosis of breast cancer, J. Gynecol. Obstet. Biol. Reprod., vol. 6, pp. 7-31, 1997. [5] V. P. Jackson, H. E. Reynolds, and D. R. Hawes, Sonography of the breast. Semin. Ultrasound CT MR, vol. 17, pp. 460-475, 1996. [6] E. Tohno, D. O. Cosgrove, and J. P. Sloane, Ultrasound diagnosis of breast diseases, Elsevier Health Sciences, Edinburg, 1994. [7] H. Taki, T. Sakamoto, M. Yamakawa, T. Shiina, and T. Sato, Calculus Detection for Medical Acoustic Imaging using Cross-correlation: Simulation Study, J Med. Ultrasonics, vol. 37, pp. 19-135, 010. [8] H. Taki, T. Sakamoto, M. Yamakawa, T. Shiina, and T. Sato, Small calculus detection for medical acoustic imaging using cross-correlation between echo signals, Proc. IEEE Int. Ultrason. Symp., pp. 398-401, 009. [9] H. Taki, K. Taki, T. Sakamoto, M. Yamakawa, T. Shiina, and T. Sato, High range resolution medical acoustic vascular imaging with frequency domain interferometry, Proc. IEEE EMBS, accepted. 179