W DATA SHEET Current Transformer 40 x 10, A

Similar documents
Powered by technology...driven by service CURRENT TRANSFORMERS. Multifunction Meters. Transducers & Isolators. Temperature Controllers

Current / residual current and voltage transformers. Current / residual current and voltage transformers

Measuring current transformers of the W, W series

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

MEDIUM-VOLTAGE MEASURING VOLTAGE TRANSFORMERS USER MANUAL

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

DATA SHEET Selectable AC transducer TAS-311DG

EA16, EB16, EA17, EA19

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

Summation current transformers, type KSU/SUSK

RISH Ducer E13 3 channel transducer for AC current and voltage

27/04/2015

T-Line, current transformers

QUINT-PS AC/24DC/40

Series P. Applications

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

DEIF A/S. TAS-311DG Selectable AC transducer J (UK) Installation and start up instructions

LED control gear Compact fixed output. Uconverter LCI 20 W 350/500/700 ma TEC SR TEC series

POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Measuring current transformers of the W AB(P) series

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Theta 20A / 20V. Technical Data Sheet. Special Features

Medium-voltage transfomers

Accessories. Accessories

PRODUCT FOR HIGH VOLTAGE APPLICATION. Current transformers for Gasinsulated. Instructions for installation, use and maintenance

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

QUINT-PS/ 1AC/24DC/20

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

Enhanced Quality with a Touch of Style

n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V)

COMPACT LED DRIVERS. ComfortLine Selectable Current (LEDset) ComfortLine SELECTABLE CURRENT LEDset ,

02/11/2015

LED Driver Compact fixed output

SINEAX B 811 Power Pack with additional Functions

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

TRANSFORMERS FOR GIS APPLICATIONS VOLTAGE VOLTAGE TRANSFORMERS FOR GIS APPLICATIONS

MOVING-IRON METERS EA16, EB16, EA17, EA19, EA12 TYPES

MBS AG. KBR 18 Split-core current transformer. Further information about our new split-core current transformer KBR 18: Dimensions:

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Energy Management Energy Meter Type EM110

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Theta Hz. Technical Data Sheet. Special Features

50-SDMS-01 SPECIFICATIONS FOR

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole

Content. 1. Dimensiong of CT s. 2. Error definitions. 3. General design aspects. 4. Linear cores. Certified acc. to ISO 9001/14001, SN EN 45001

EMD-FL-3V Phase Voltage Monitoring Relay INTERFACE. Data Sheet. Description

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Energy Management Energy Meter Type EM110


RING CORE CURRENT TRANSFORMERS FOR LOW VOLTAGE TYPE AOS USER MANUAL

Installation and Operating Instructions for Phase Demodulator Type _.2

Fuse Links NV/NH gg with Striker Pin Dimensions

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

1 2 3 GridVis Pulse output 2 tariffs Modbus MID M-Bus

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

Electronic Circuit Protector ESX10-T

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Use RH covers when starting with a LH feed unit or when reaching the LH board. HIGH RATING

Data Sheet. Summation Current Transformer OMEGA SUMMATION CT : SIGMA SERIES. Page 1 of 5 00 / 1213

RE17LLBM asymmetrical flashing relay s V AC - solid state output

QUINT-PS/ 3AC/24DC/10

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PVS.81

Transformers, Power Supply Units and Socket Outlets

LOW VOLTAGE CONVERTER WITH THREE POINT GALVANIC INSULATION

Zelio Control Measurement Relays

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

CONTENTS XV300K GB r doc XV300K 2/13

IMPULSE SWITCH, REMOTE SWITCH

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

Three-phase monitoring relay CM-PFS

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

I P I OUT R L. Applications. Standards. N 52.D ; Page 1/8

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

(1,5 modules per pole)

Type CP-S, CP-C & CP-A Switch mode

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

QUINT-PS/ 3AC/24DC/40

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Three-phase monitoring relays

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

Transcription:

W DATA SHEET Current Transformer 40 x 10, 250 600A W SCHRACK-INFO Current transformers for low-voltage network accuracy Single-phase current transformer Passing cable/ bus bar primary Primary current 250 800A Secondary current 5A W TECHNICAL DATA: REFERENCE STANDARDS EN60044-1 SPECIFICATIONS Rated primary current I pr : 250A, 400A, 500A, 600A, 800A Rated frequency: 50Hz Working frequency: 47-63Hz Rated continuous thermal current according to EN60044-1 (Icth) Rated short-time thermal current I th : < 60I pr Rated dynamic current Idyn : 2,5I th Instrument security factor (FS): 5 Rated secondary current I sr : 5A Rated burden: 1,5...12VA (see table) Accuracy class: 0,5-1 (see table) Max. power dissipation for switchboard thermal calculation: 11,5W at Icth The allowed max cable or busbar temp is: 125 C SIDE 1/5

RATED BURDEN Accuracy class Type: Class 0,5 Class 1 250/5A 3VA 4VA 300/5A 4VA 6VA 400/5A 6VA 8VA 500/5A 6VA 8VA 600/5A 6VA 8VA 800/5A 10VA 12VA INSULATION REQUIREMENTS Dry transformer, air insulation Highest voltage for equipment U m : Rated insulation level: Class of insulation (EN60044-1): 0,72kV r.m.s. 3kV r.m.s. 50Hz/1min B ENVIRONMENTAL CONDITIONS Non-exposed installation (EN60044-1) Reference temperature: 23 C ± 1 C Nominal temperature range: - 25 50 C Daily mean temperature: 30 C Limit temperature range for storage: - 40 85 C Relative humidity: 85% (Suitable for tropical climates) LIMITS OF CURRENTS ERROR AND PHASE DISPLACEMENT (EN60044-1) Accuracy ± Percentage current (ratio) error at ± Phase displacement at percentage of rated current shown below percentage of rated current shown below Minutes Centiradians class 5%In 20%In 100%In 120%In 5%In 20%In 100%In 120%In 5%In 20%In 100%In 120%In 0,5 1,5 0,75 0,5 0,5 90 45 30 30 2,7 1,35 0,9 0,9 1 3 1,5 1 1 180 90 60 60 5,4 2,7 1,8 1,8 The current error and phase displacement at rated frequency shall not exceed the values given in table when the secondary burden is any value from 25% to 100% of the rated burden. SIDE 2/5

HOUSING Housing material: Protection degree (EN60529): Mounting: Rail type: Weight: CONNECTIONS Primary winding: Max. tightening torque for passing primary bar fixing screws: Secondary winding: Connections label: self extinguishing polycarbonate IP20 snap-on 35mm rail, screw type for wall mounting top hat TH35-15 (EN60715) 300 grams passing cable 0,2Nm screw terminals 6mm², faston 4,8x0,8 primary winding P1(K) P2(L) secondary winding s1(k) s2(l) FIXING ON DIN RAIL EN50022 SIDE 3/5

W ATTENTION: Working time guaranteed with secondary winding open for 1 minute Current transformers should not be operated with the secondary winding open-circuited because of the potentially dangerous over-voltages and overheating which can occur (EN 60044-1/A2). To obviate this problem, it is possible to use accessory to be directly connected with the transformer secondary winding, which is able to continuously detect the terminal voltage and, if the voltage reaches the threshold value (18V) owing to a connection breakdown or disconnection of the devices, automatically closes again the circuit. When the normal working conditions are restored, it automatically disconnects. Continuously connected with the secondary winding of the transformer to protect, it doesn t affect at all the current transformer features or performances. It doesn t need any external supply (self-supplied). W DIMENSIONS: SIDE 4/5

W WIRING DIAGRAM: W ARTICLES: Current Transformer 250/5A 40X10 Current Transformer 400/5A 40X10 Current Transformer 500/5A 40X10 Current Transformer 600/5A 40X10 Current Transformer 800/5A 40X10 MG955025-A MG955040-A MG955050-A MG955060-A MG955080-A SIDE 5/5