CHAPTER 3 WIRING DANGER

Similar documents
Preface WARNING. CAUTION! Heat sink may heat up over 70 o C (158 o F), during the operation. Do not touch the heat sink.

Preface DANGER! PLEASE READ PRIOR TO INSTALLATION FOR SAFETY.

FE0 9

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3

Preface PLEASE READ PRIOR TO INSTALLATION FOR SAFETY.

Preface DANGER! PLEASE READ PRIOR TO INSTALLATION FOR SAFETY.

Preface DANGER! PLEASE READ PRIOR TO INSTALLATION FOR SAFETY.

Preface DANGER! PLEASE READ PRIOR TO INSTALLATION FOR SAFETY.

VFD-EL Series User Manual

E L (0) / FAX:+31(0)

VFD-EL Series User Manual

Preface DANGER! PLEASE READ PRIOR TO INSTALLATION FOR SAFETY.

PLEASE READ PRIOR TO INSTALLATION FOR SAFETY.

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

VFD-M Series User Manual

FREQUENCY INVERTER. Series L2500 MANUAL

A510 INVERTER. 230VClas3~ kW 1-3HP HP kW 1-425HP. 460VClas3~ 575/690VClas3~ 1-270HP INSTRUCTIONMANUAL

HSE3

CHAPTER 5 DESCRIPTION OF PARAMETER SETTINGS

ZVD AC Motor Drive User Manual

WARNING. must comply with the laws of the country where the AC drive is to be installed. Refer to Basic Wiring Diagram.

VLT MICRO Series Adjustable Frequency Drive Instruction Manual

Delta Fan and Pump Drive CFP2000 Series User Manual

Table of Contents Preface Chapter 1 Safety Precautions Chapter 2 Model Description Chapter 3 Environment and Installation...

Operation Instructions NORDAC SK 400E. Frequency Inverter. SK 400E B / SK 400E B (0.4kW / 0.7kW, 1~ 115V)

CHAPTER 8 PARAMETER SUMMARY

N3 INVERTER SERIES. Operating Manual. 230V 1Ø 0.5-3HP kW. 230V 3Ø HP kW. 460V 3Ø 1-75HP kW. Revision: 2.03.

Delta Elevator Drive ED Series.

THYFREC-VT230S 200V System 0.4 to 90kW 400V System 0.4 to 370kW INSTRUCTION MANUAL

CHAPTER 5 DESCRIPTION OF PARAMETER SETTINGS

Version number A=standard P=Cold Plate (Frame A only) T=Brake chopper (Frame A only) Input voltage 11=115VAC 21=230VAC 1φ 23=230VAC 3φ 43=400VAC

Compliance with CE Marking, UL Standard and CSA Standard

Sensorless Vector Control Compact Drive VFD-E Series User Manual

G+ Mini Transition Guide. Product Transition Guide P3 Series 2 to G+ Mini

CHAPTER AC DRIVE PARAMETERS. In This Chapter...

Thank you for purchasing FCS (Franklin Control Systems former Cerus) VFD SAFETY INSTRUCTIONS

VSD Series II Variable Speed Micro Drives (VSM II) FS1 FS5

Operating Instructions

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual

P Series. Installation, Programming Operation, & Maintenance Manual. Fan & Pump Optimized Variable Frequency Drive.

CHAPTER 8 SUMMARY OF PARAMETER SETTINGS

High Frequency Sinewave Guardian TM Filter

INSTRUCTION MANUAL (BASIC)

High Frequency SineWave Guardian TM Filter

Power connections, minimum and maximum wiring capabilities, tightening torque

3G3JX 200 V V V

OPERATING MANUAL SERIES R B F BRUSHLESS RACK SYSTEM

V7 and V74X Drives Technical Manual

This section is specifically about safety matters WARNING CAUTION WARNING

INVERTER FR-F700P INSTRUCTION MANUAL (BASIC)

F7 Drive User Manual Model: CIMR-F7U Document Number: TM.F7.01

GS1 Parameter Summary Detailed Parameter Listings...4 9

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

RSi SG Series Sensorless Vector Variable Frequency Drive

VLT 5000/6000 Series. Contents

MagneTek. GPD 503 Technical Manual

4.2.3 Main Circuit Cable Size and Tightening Torque Control Circuit Control Circuit Terminals

S11 Adjustable Speed Drive Engineering Specification

PowerFlex 400 Submittal

Phoenix DX Clean Power (18 Pulse) AC Drive

This section is specifically about safety matters

AC SPEED CONTROL EQUIPMENT. VAT2000 3ph 200V-230V System 0.4 to 45kW 3ph 380V-460V System 0.4 to 370kW INSTRUCTION MANUAL

1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control.

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

Installation & Operation Manual RSDA SERIES. ADjUSTAbLe FReqUenCy DRIveS FOR 3-PHASe AC MOTORS NEMA 4X /IP65

Contents. 1 Handling Inverters Wiring

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

INSTRUCTION MANUAL (BASIC) FR-F520J-0.4K to 15K(F) FR-F540J-0.4K to 15K(F)

INVERTER FR-A700 INSTRUCTION MANUAL (BASIC) FR-A K to 90K FR-A K to 500K

Bypass Panels FRENIC-EcoPAK. Fuji Electric Corp. of America FECA-IN-105 / Information subject to change without notice.

Fan and Pump AC Inverter

This operation manual is intended for users with basic knowledge of electricity and electric devices.

FR-F520J-0.4K to 15K (F) FR-F540J-0.4K to 15K (F)

Analog Servo Drive. Peak Current 16 A (11.3 A RMS )

VF-nC1 Adjustable Speed Drive Engineering Specification

CHAPTER MAINTENANCE AND TROUBLESHOOTING. In This Chapter... Maintenance and Inspection Troubleshooting...6 3

Manual Overview...1 2

GPD 315/V7 and V7-4X Technical Manual

Capstone Turbine Corporation Nordhoff Street Chatsworth CA USA Phone: (818) Fax: (818) Web:

FR-E K to 7.5K-EC FR-E520S-0.4K to 2.2K-EC

E3 Adjustable Speed Drive Engineering Specification

EMI Installation Guidelines

SAFETY INSTRUCTIONS. To prevent injury and property damage, follow these instructions during the installation and operation of the inverter.

Rsi S Series. Instruction Manual. Low Voltage Variable Frequency Drive Benshaw Corporation

Analog Servo Drive 20A20

Emotron VSU. AC Drive. Instruction manual. 0.4kW to 15kW / 0.5Hp to 20Hp. English

TRANSISTORIZED INVERTER FR-E560 INSTRUCTION MANUAL

NZV Series Sensorless Vector Control Inverter Operation Manual

*MG21E122* Instruction Manual VLT Automation VT Drive FC 322 MAKING MODERN LIVING POSSIBLE

Analog Servo Drive 30A20AC

FR-ABR-(H)0.4K to 22K

FR-S520E-0.1K to 3.7K-NA FR-S540E-0.4K to 3.7K-NA FR-S510WE-0.1K to 0.75K-NA

Thank you for purchasing Marathon Drive Variable Frequency Drives! SAFETY INSTRUCTIONS

This Chapter contains:

Peak Current. Continuous Current. See Part Numbering Information on last page of datasheet for additional ordering options.

Varispeed V7 INSTRUCTION MANUAL

Cat. No. I528-E1-2 USER S MANUAL SYSDRIVE 3G3JV. Compact Simplified Inverters

Cat. No. I559-E1-02 USER S MANUAL SYSDRIVE MX SERIES. Multi-function Compact Inverter

Emotron VSU. AC Drive. Instruction manual. 1.5kW to 15kW / 2Hp to 20Hp. English

Index. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6

Transcription:

CHAPTER WIRING DANGER Hazardous Voltage Before accessing the AC drive: Disconnect all power to the AC drive. Wait five minutes for DC bus capacitors discharge. Any electrical or mechanical modification to this equipment without prior written consent of Delta Electronics, Inc. will void all warranties and may result in a safety hazard in addition to voiding the UL listing. Short Circuit Withstand: The rated voltage must be equal to or less than 240V (460V model is 480Volts) and the current must be equal to or less than 5000A RMS. (the model of 51HP or above is 10000A RMS) General Wiring Information Applicable Codes VFD-V AC drives (007V2/4A, 015V2/4A, 022V2/4A, 07V2/4A, 055V2/4A, 075V2/4A, 110V4B, 110V2/4A, 150V2/4A, 185V2/4A, 220V2/4A, 00V2/4A, 70V2/4A, 450V4A) are Underwriters Laboratories, Inc. (UL) and Canadian Underwriters Laboratories (cul) listed, and therefore comply with the requirements of the National Electrical Code (NEC) and the Canadian Electrical Code (CEC). Installation intended to meet the UL and cul requirements must follow the instructions provided in Wiring Notes as a minimum standard. Follow all local codes that exceed UL and cul requirements. Refer to the technical data label affixed to the AC drive and the motor nameplate for electrical data. The "Line Fuse Specification" in Appendix B, lists the recommended fuse part number for each V-Series part number. These fuses (or equivalent) must be used on all installations where compliance with U.L. standards is a required. DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED -1

.1 Basic Wiring Diagram For wiring of the inverter, it is divided into the main circuit and the control circuit. Users could open the case cover, and could inspect the main circuit terminal and the control circuit terminal; users connect the circuit in compliance with the following wiring method. The following diagram is the standard wiring diagram for the VFD-V inverter. Wiring Diagram 1 10HP(7.5kW) and below R/L1 S/L2 T/L Fuse/NFB(None Fuse Breaker) Recommended Circuit when power supply is turned OFF by a fault output Factory Default: SINK Mode Sink Sw1 Source Please refer to wiring of SINK mode and SOURCE mode. Factory default FWD/STOP REV/STOP Multi-step 1 Multi-step 2 Multi-step Multi-step 4 Multi-step 5 Multi-step 6 Digital Signal Common * Don input voltage directly to the above signals. 5K OFF 1 2 SA ON MC 4~20mA -10~+10V Analog Signal Common DC choke (optional) Jumper +1 R/L1 S/L2 T/L E MC RB RC +24V FWD REV MI1 MI2 MI MI4 MI5 MI6 DCM Shield terminal MO1 MO2 +10V Power supply +10V 20mA AVI Master Frequency 0 to 10V 47K ACI AUI ACM B2 U/T1 V/T2 W/T E RA RB RC MRA MRC MCM AFM ACM E DFM DCM Motor IM ~ Please refer to ontrol Terminal Explanation? Factory setting: Operation Indication Multi-function Photocoupler Output 48VDC 50mA Factory default: Frequency-Achieving Indication Factory default: Driver-Ready Indication Photocoupler Common Output Terminal Multi-function Analog Output Terminal Factory default: Output Frequency 0~ 10VDC/2mA Analog Signal common Digital Frequency Output Terminal Factory default: 1:1 Duty=50% 10VDC Digital Signal Common RS-485 Serial interface 1: +EV 2: GND : SG- 4: SG+ 5:NC 6: NC Main circuit (power) terminals Control circuit terminals Shielded leads & Cable -2 DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED

Wiring Diagram 2 15HP(11kW) and above R/L1 S/L2 T/L Fuse/NFB(None Fuse Breaker) Recommended Circuit when power supply is turned OFF by a fault output Factory Default: SINK Mode Sink Sw1 Source Please refer to wiring of SINK mode and SOURCE mode. Factory default FWD/STOP REV/STOP Multi-step 1 Multi-step 2 Multi-step Multi-step 4 Multi-step 5 Multi-step 6 Digital Signal Common * Don input voltage directly to the above signals. 5K OFF 1 2 SA ON MC 4~20mA -10~+10V Analog Signal Common DC chock (optional) Jumper +1 R/L1 S/L2 T/L E MC RB RC VFDB +24V FWD REV MI1 MI2 MO1 MI MI4 MI5 MO2 MI6 DCM Shield terminal +10V Power supply +10V 20mA AVI Master Frequency 0 to 10V 47K ACI AUI ACM -(minus sign) U/T1 V/T2 W/T E RA RB RC MRA MRC MCM AFM ACM Motor IM ~ Please refer to ontrol Terminal Explanation? Factory setting: Operation Indication Multi-function Photocoupler Output 48VDC 50mA Factory default: Frequency-Achieving Indication Factory default: Driver-Ready Indication Photocoupler Common Output Terminal Multi-function Analog Output Terminal Factory default: Output Frequency 0~ 10VDC/2mA Analog Signal common E DFM Digital Frequency Output Terminal Factory default: 1:1 Duty=50% 10VDC Digital Signal Common DCM RS-485 Serial interface 1: +EV 2: GND : SG- 4: SG+ 5:NC 6: NC Main circuit (power) terminals Control circuit terminals Shielded leads & Cable DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED -

Wiring of SINK mode and SOURCE mode FWD/STOP REV/STOP Multi-step 1 Multi-step 2 Multi-step Multi-step 4 Multi-step 5 Multi-step 6 Digital Signal Common +24V FWD REV MI1 MI2 MI MI4 MI5 MI6 DCM Sink Sw1 Source FWD/STOP REV/STOP Multi-step 1 Multi-step 2 Multi-step Multi-step 4 Multi-step 5 Multi-step 6 Digital Signal Common +24V FWD REV MI1 MI2 MI MI4 MI5 MI6 DCM -4 DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED

.2 External Wiring VFD-V Series Power Supply EMI Filter R/L1 S/L2 T/L U/T1 V/T2 W/T FUSE/NFB Magnetic contactor Input AC Line Reactor +2/B1 B2 Zero-phase Reactor +1 Output AC Line Reactor DC Choke Zero-phase Reactor Braking Resistor Items Power supply Fuse/NFB (Optional) Magnetic contactor (Optional) Input AC Line Reactor (Optional) Zero-phase Reactor (Ferrite Core Common Choke) (Optional) EMI filter (Optional) Explanations Please follow the specific power supply requirement shown in APPENDIX-A. There may be inrush current during power up. Please check the chart of APPENDIX B and select the correct fuse with rated current. NFB is optional. Please do not use a Magnetic contactor as the I/O switch of the AC drive, this will reduce the operating life cycle of the AC drive. In order to improve the input power factor, reduces harmonics and protection from AC line disturbances. (Surge, switching spike, power flick, etc.) AC line reactor should be installed when the power supply capacity is 500kVA or more and exceeds 6 times of the inverter capacity, or the wiring distance within 10m. Zero phase reactors are used to reduce radio noise specify when the audio equipments installed near the inverter. Good effective for noise reduction on both the input and output sides. Attenuation quality is good in a wide range from AM band to 10Mhz. Appendix B for specifies zero phase reactors. (RF220X00A) To reduce the electromagnetic interference. Please refer to Appendix B for detail. Motor Braking Resistor (Optional) Used to reduce stopping time of the motor. Please refer to the chart on Appendix B for specific Braking Resistors. Output AC Line Reactor (Optional) Motor surge voltage amplitudes depending on the motor cable length. For long motor cable application, it is necessary installed on the inverter output side. DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED -5

. Main Circuit Terminal Explanations Terminal Symbol R/L1, S/L2, T/L Content Explanation Input terminals for business-used power supply U/T1, V/T2, W/T Output terminals for the AC motor drivers (at the side of the motor) Power-improved continuing terminals of the DC reactor; disconnect +1~+2/B1 the short-circuit piece when the device is installed Connecting terminals of the braking resistor; purchase and install +2/B1~B2 these devices according to the selection chart +2/B1~ Continuing terminals of the braking module (the VFDB series) Ground terminals, please have these terminals grounded following the third-type grounding of 20V series and the special grounding of 460V series within the electrician regulations.4 Control Terminal Explanations Terminal Symbol Explanation on the Terminal Function FWD FWD RUN-STOP command Factory Setting REV REV RUN-STOP command MI1 Multi-function input selection 1 (-wire Multi-step 1 command STOP-designated terminal) MI2 Multi-function input selection 2 Multi-step 2 command MI Multi-function input selection Multi-step command MI4 Multi-function input selection 4 Multi-step 4 command MI5 Multi-function input selection 5 Abnormal reset command MI6 Multi-function input selection 6 (TRG-designated EF terminal) DFM Digital frequency signal output 1:1 +24V Digital control signal the common end +24V 20mA DCM Digital control signal the common end RA Multi-function relay output contact (NO a) Resistive Load RB Multi-function relay output contact (NC b) 5A(N.O.)/A(N.C.) 240VAC RC Multi-function relay output contact 5A(N.O.)/A(N.C.) 24VDC MRA Multi-function relay output contact (NO a) MRC Multi-function relay output contact the common end Inductive Load 1.5A(N.O.)/0.5A(N.C.) 240VAC 1.5A(N.O.)/0.5A(N.C.) 24VDC Refer to Pr.02-11 to Pr.02-12 MO1 Multi-function output terminal 1 (photo coupler) Instruction during operation -6 DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED

Terminal Symbol Explanation on the Terminal Function Factory Setting MO2 Multi-function output terminal 2 (photo coupler) (Max 48VDC 50mA) Set up the frequency attained MO Multi-function output terminal (photo coupler) Driver ready (Max 48VDC 50mA) MCM Multi-function output terminal the common end Max 48VDC 50mA +10V Auxiliary reference power +10V 20mA AVI ACI AUI AFM ACM Analog voltage frequency command Analog current frequency command Auxiliary analog voltage frequency command Multi-function analog voltage output Analog control signal the common end VFD-V Series The greatest operation frequency corresponding to 0~+10V The greatest operation frequency corresponding to 4~20mA The greatest operation frequency corresponding to -10~+10V The greatest operation frequency corresponding to -10~10V * Analog control signal wire specification: 18 AWG (0.8 mm 2 ), cover the isolation twisted wire. DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED -7

.5 Component Explanations 1 HP to 5 HP (VFD007V2A/4A, VFD015V2A/4A, VFD022V2A/4A, VFD07V2A/4A) +1 +2 B1 - B2 U/T1 V/T2 W/T Screw Torque : 18Kgf-cm Wire Gauge : 18~10AWG R/L1 S/L2 T/L Control Terminal Torque: 8Kgf-cm (6.9 in-lbf) Wire: 22-14 AWG Power Terminal Torque: 18 kgf-cm (15.6 in-lbf) Wire Gauge: 18-10 AWG Wire Type: Stranded Copper only, 75 C -8 DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED

7.5 HP to 15 HP (VFD055V2A/4A, VFD075V2A/4A, VFD110V4B) POWER IM MOTOR Control Terminal Torque: 8Kgf-cm (6.9 in-lbf) Wire: 22-14 AWG Power Terminal Torque: 0 kgf-cm (26 in-lbf) Wire Gauge: 12-8 AWG Wire Type: Stranded Copper only, 75 C Note: If wiring of the terminal utilizes the wire with a 6AWG-diameter, it is thus necessary to use the Recongnized Ring Terminal to conduct a proper wiring. DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED -9

15HP to 0HP (VFD110V2A/4A, VFD150V2A/4A, VFD185V2A/4A, VFD220V2A/4A) R/L1 S/L2 T/L +1 +2 - POWER DC ( + ) DC ( -) IM V/T2 W/T MOTOR Control Terminal Torque: 8Kgf-cm (6.9 in-lbf) Wire: 22-14 AWG Power Terminal Torque: 0 kgf-cm (26 in-lbf) Wire Gauge: 8-2 AWG Wire Type: Stranded Copper only, 75 C NOTE: If wiring of the terminal of VFD220V2A utilizes the wire with a 1AWG-diameter, it is thus necessary to use the Recognized Ring Terminal to conduct a proper wiring. -10 DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED

POWER ALARM VFD-V Series 40 to 50 HP 20V (VFD00V2A, VFD70V2A) CHARGE R/L1 S/L2 T/L +1 +2 U/T1 V/T2 W/T Screw Torque: IM POWER 200kgf-cm (17in-lbf) MOTOR Control Terminal Torque: 8Kgf-cm (6.9 in-lbf) Wire: 22-14 AWG Power Terminal Torque: 200 kgf-cm (17.6 in-lbf) Wire Gauge: 1/0 4/0 AWG Wire Type: Stranded Copper only, 75 C DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED -11

POWER ALARM VFD-V Series 40HP to 60HP 460V (VFD00V4A, VFD70V4A, VFD450V4A) CHARGE R/L1 +1 +2 - S/L2 T/L U/T1 V/T2 2/T IM POWER MOTOR Control Terminal Torque: 8Kgf-cm (6.9 in-lbf) Wire: 22-14 AWG Power Terminal Torque: 57 kgf-cm (49.5 in-lbf) Wire Gauge: 4-2 AWG Wire Type: Stranded Copper only, 75 C -12 DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED

75-100 HP 460V (VFD550V4A, VFD750V4A) R/L1 S/L2 T/L +1 +2 U/T1 V/T2 W/T POWER Screw Torque: 200kgf-cm MOTOR Control Terminal Torque: 8Kgf-cm (6.9 in-lbf) Wire: 22-14 AWG Power Terminal Torque: 200 kgf-cm (17.6 in-lbf) Wire Gauge: 1/0 4/0 AWG Wire Type: Stranded Copper only, 75 C DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED -1

.6 Wiring Notice 1. There are corresponding ring terminals which will be included with each unit (15-0HP), and please use the proper crimping tool by KST INC. P/N: KST-HDC8A for securing the conductor. 2. When wiring up, and that the wiring route specifications are settled, please conduct the wiring following the electrician regulations.. The connection between the three-phase AC input power and the main circuit terminal R/L1, S/L2, T/L has to set up a none-fusing switch in between. The best is to series connect with an electro-magnetic contactor (MC) so as to cut off the power supply at the same time when the inverter protection function acts. (The two ends of the electro-magnetic contactor should have the R-C Varistor). 4. There is no phase-order differentiation in the input power R/L1, S/L2, T/L and users could connect with either one of use. 5. The ground terminal E is grounded with the third-type grounding method (with the grounding impedance under 100Ω). 6. The grounding wire of the inverter could not be grounded at the same time with machinery with grand current loading, like that of the electric soldering machine and of the motor with grand horsepower; they have to be grounded individually. 7. The shorter the ground wire, the better it is. 8. When several inverters are grounded at the same time, be sure not to make it into a ground circuit. Please refer to the following diagram: FWD RUN 9. If the output terminals U/T1, V/T2 and W/T of the inverter are connecting relatively to the U, V, and W terminals of the motor, the FWD indicator located on the digital control panel of the inverter will be lit, and that means the inverter is running forward, and the rotation direction of the motor will be shown as the right hand side diagram above; if the REV indicator is lit, it means that the inverter is running in reverse direction, and the rotation direction will be of the opposite direction compared with the above diagram. If users are not sure of whether the connection between output terminals U/T1, V/T2 and W/T of the inverter is of one-to-one connection with U, V, and W terminals of the motor, simply swap either two wires among the U, V, and W terminals of the motor for correction if the inverter is running forward while the motor is running at reverse direction. -14 DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED

10. Be sure of the power voltage and the greatest current possible supplied. 11. When the Digital Hand-held Programming Panel is displayed, please do not disconnect or dissemble any wiring. 12. No braking resistor is installed within the VFD-V inverter (selective purchasing item), therefore, be sure to purchase and install the braking resistor if to be used on occasions when the loading inertia is great or that it is of frequent start/stop. 1. Be sure not to connect the AC power with the terminals U/T1, V/T2 and W/T on the power-generating side of the inverter. 14. Please tightly fasten the screws of the main circuit terminals so as to prevent sparks generated due to the vibration and loosening of the screws. 15. Wiring of the main circuit and of the control circuit should be separated so as to prevent erroneous actions. If the interlock connection is needed, please make it an intersection of 90. 16. If terminals U/T1, V/T2 and W/T on the power-generating side of the inverter is in need of the noise wave-filter, it is then necessary to use the induction-type L-Varistor, but be sure not to add in the phase-carrying capacitor or the L-C- and R-C-type wave filters. 17. Please use the separating wire as much as possible during control wiring, and be sure not to expose the peeled-off separation net in front of the terminal to the external. 18. Please use the separating wire or tube as much as possible during power wiring, and ground these two ends of the separating layer or tube to the ground. 19. If the installation site of the inverter is sensitive to interferences, please have the RFI wave filters installed, and the nearer the inverter to the installation site, the better. In addition, the lower the carrier wave frequency of, the less the interferences. 20. If the electric-leakage circuit breaker is installed in the inverter, it could serve as the protection for the electric-leakage error, and as the prevention on the erroneous actions of the electric-leakage circuit breaker; please select the sensor current above 200mA with the action time of more than 0.1 second to have these actions accessible. DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED -15